Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.8 LAccepted-AOC | 1 | Accepted-AOC Being lowest tenderer | |
| 2 | 2₹9.6 L+₹29,040 (3.14%)Rejected-AOC | 2 | Rejected-AOC 2nd | |
| 3 | 3₹9.9 L+₹65,140 (7.03%)Rejected-AOC | 3 | Rejected-AOC 3rd | |
| 4 | 4₹10.4 L+₹1.1 L (11.9%)Rejected-AOC | 4 | Rejected-AOC 4th | |
| 5 | 5₹11.6 L+₹2.4 L (25.5%)Rejected-AOC 1 OPP NAGAR NIGAM KATNI MAIN ROAD KATNI MADHYA PRADESH 483501 | KATNI | MADHYA PRADESH | 483501 | 5 | Rejected-AOC 5th |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
23 Jul 2020, 6:00 pmClosed
GE AF TUGHLAKABAD
GE AF TUGHLAKABAD SANGAM VIHAR PO NEW DELHI 110080
Repair/replacement of switch gear, changeover switch and all other connected misc accessories at Tech area under GE (AF) Tughlakabad
2020_MES_355223_1
GE/TKD/TOKEN-01/2020-21
Open Tender
Civil Works - Others
Item Rate
330 days
GE AF TUGHLAKABAD
MES contractor enlisted as Class E or above category bi having deposited Standing Security of Rs. 50000 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
8 documents required · 8 mandatory
₹500
Yes
GE AF TUGHLAKABAD
₹30,000
Yes
18 Sept 2020
23 Jun 2020
25 Jul 2020
6 Jul 2020
23 Jul 2020
6 Jul 2020
24 Jun 2020 - 6 Jul 2020
Amount
S&F in replacement MCCB 630 Amps 3 Pole breaking capacity 50 KA, 415 V, ICS=75 % of ICU Adjustable thermal and adjustable magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Cat No IHLLNFCT0630# OF Havells/Cat No 422018 of Legrand/ISLLNFCT0630# OF Standard
S&F in replacement MCCB 630 Amps 4 Pole breaking capacity 50 KA, 415 V, ICS=75 % of ICU Adjustable thermal and adjustable magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Cat No IHLLNFCF0630# OF Havells/Cat No 422023 of Legrand/ISLLNFCF0630# OF Standard
S&F in replacement MCCB 400 Amps 3 Pole breaking capacity 50 KA, 415 V, ICS=75 % of ICU Adjustable thermal and adjustable magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Cat No IHLLNFCT0400# OF Havells/Cat No 422016 of Legrand/ISLLNFCT0400# OF Standard
S&F in replacement MCCB 400 Amps 4 Pole breaking capacity 50 KA, 415 V, ICS=75 % of ICU Adjustable thermal and adjustable magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Cat No IHLLNFCF0400# OF Havells/Cat No 422021 of Legrand/ISLLNFCF0400# OF Standard
S&F in replacement MCCB 250 Amps 3 Pole breaking capacity 50 KA, 415 V, ICS=75 % of ICU Adjustable thermal and adjustable magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Cat No IHLLNFCT0250# OF Havells/Cat No 420269 of Legrand/ISLLNFCT0250# OF Standard
S&F in replacement MCCB 250 Amps 4 Pole breaking capacity 50 KA, 415 V, ICS=75 % of ICU Adjustable thermal and adjustable magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Cat No IHLLNFCF0250# OF Havells/Cat No 420279 of Legrand/ISLLNFCF0250# OF Standard
S&F in replacement MCCB 200 Amps 3 Pole breaking capacity 50 KA, 415 V, ICS=75 % of ICU Adjustable thermal and adjustable magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Cat No IHLLNFCT0200# OF Havells/Cat No 420268 of Legrand/ISLLNFCT0200# OF Standard
S&F in replacement MCCB 200 Amps 4 Pole breaking capacity 50 KA, 415 V, ICS=75 % of ICU Adjustable thermal and adjustable magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Cat No IHLLNFCF0200# OF Havells/Cat No 420278 of Legrand/ISLLNFCF0200# OF Standard
S&F in replacement MCCB 400 Amp 3 Pole breaking capacity 36 KA, 415 V, ICS=100 % of ICU Adjustable thermal and adjustable magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Cat No IHLLSECT0400# OF Havells/Cat No 422002 of Legrand/ISLLSECT0400# OF Standard
S&F in replacement MCCB 400 Amps 4 Pole breaking capacity 36 KA, 415 V, ICS=100 % of ICU Adjustable thermal and adjustable magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Cat No IHLLNSECF0400# OF Havells/Cat No 422007 of Legrand/ISLLSECF0400# OF Standard
S&F in replacement MCCB 250 Amps 3 Pole breaking capacity 36 KA, 415 V, ICS=100 % of ICU Adjustable thermal and adjustable magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Cat No IHLLSECT0250# OF Havells/Cat No 420239 of Legrand/ISLLSECT0250# OF Standard
S&F in replacement MCCB 250 Amps 4 Pole breaking capacity 36 KA, 415 V, ICS=100 % of ICU Adjustable thermal and adjustable magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Cat No IHLLNSECF0250# OF Havells/Cat No 420249 of Legrand/ISLLSECF0250# OF Standard
S&F in replacement MCCB 200 Amps 3 Pole breaking capacity 36 KA, 415 V, ICS=100 % of ICU Adjustable thermal and adjustable magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Cat No IHLLSECT0200# OF Havells/Cat No 420238 of Legrand/ISLLSECT0200# OF Standard
S&F in replacement MCCB 200 Amps 4 Pole breaking capacity 36 KA, 415 V, ICS=100 % of ICU Adjustable thermal and adjustable magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Cat No IHLLNSECF0200# OF Havells/Cat No 420248 of Legrand/ISLLSECF0200# OF Standard
S&F in replacement MCCB 250 Amps 3 Pole breaking capacity 25 KA, 415 V, ICS=75 % of ICU Adjustable thermal and fixed magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Cat No IHLANDCT0250# OF Havells/Cat No 420209 of Legrand/ISLANT0250 OF Standard
S&F in replacement MCCB 250 Amps 4 Pole breaking capacity 25 KA, 415 V, ICS=75 % of ICU Adjustable thermal and fixed magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Cat No IHLANDCF0250# OF Havells/Cat No 420219 of Legrand/ISLANF0250 OF Standard
S&F in replacement MCCB 200 Amps 3 Pole breaking capacity 25 KA, 415 V, ICS=75 % of ICU Adjustable thermal and fixed magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Cat No IHLANDCT0200# OF Havells/Cat No 420208 of Legrand/ISLANT0200 OF Standard
S&F in replacement MCCB 200 Amps 4 Pole breaking capacity 25 KA, 415 V, ICS=75 % of ICU Adjustable thermal and fixed magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Cat No IHLANDCF0200# OF Havells/Cat No 420218 of Legrand/ISLANF0200 OF Standard
S&F in replacement MCCB 125 Amps 3 Pole breaking capacity 25 KA, 415 V, ICS=75 % of ICU Adjustable thermal and fixed magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Cat No IHLASDCT0125# OF Havells/Cat No 420046 of Legrand/ISLAST0125 OF Standard
S&F in replacement MCCB 125 Amps 4 Pole breaking capacity 25 KA, 415 V, ICS=75 % of ICU Adjustable thermal and fixed magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Cat No IHLASDCF0125# OF Havells/Cat No 422056 of Legrand/ISLASF0125 OF Standard
S&F in replacement MCCB 100 Amps 3 Pole breaking capacity 25 KA, 415 V, ICS=75 % of ICU Adjustable thermal and fixed magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Cat No IHLASDCT0100# OF Havells/Cat No 420044 of Legrand/ISLAST0100 OF Standard
S&F in replacement MCCB 100 Amps 4 Pole breaking capacity 25 KA, 415 V, ICS=75 % of ICU Adjustable thermal and fixed magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Cat No IHLASDCF0100# OF Havells/Cat No 422055 of Legrand/ISLASF0100 OF Standard
S&F in replacement MCCB 63 Amps 3 Pole breaking capacity 25 KA, 415 V, ICS=75 % of ICU Adjustable thermal and fixed magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Cat No IHLAST0063# OF Havells/Cat No 420043 of Legrand/ISLAST0063 OF Standard
S&F in replacement MCCB 63 Amps 4 Pole breaking capacity 25 KA, 415 V, ICS=75 % of ICU Adjustable thermal and fixed magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Cat No IHLASF0063# OF Havells/Cat No 422053 of Legrand/ISLASF0063 OF Standard
Dismantling/taking down existing burnt unserviceable on-load changeover switch from voltage stabliser and S&F on-load changeover switch 320 A, 415 Volts, 4 Pole with fastening elements complete all as specified and directed by Engr-in-charge.
Note: The amount of Rs 43,840.00 against schedule of credit given on Tender Serial Page No 29 shall be deducted from the total amount quoted by the contractor against BOQ while deriving the contract sum for acceptance.
M/S Delhi Engineering Co.
M/s P D SHARMA & SONS
SATISH KUMAR GUPTA
Neeraj Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .