| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.2 LAccepted-AOC 13 218 MASJID EXTEN SADAR BAZAR | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹23.8 L+₹5.6 L (30.7%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹24.2 L+₹5.9 L (32.4%)Rejected-Finance PLOT NO 17 GF PRATAP NAGAR NEW DELHI 110064 | WEST | DELHI | 110064 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹25.0 L+₹6.7 L (36.9%)Rejected-Finance 127 OLD NAGAR PALIKA BUNGLOW NO 60 NEEMUCH MP NEEMUCH MADHYA PRADESH 458441 INDIA | NEEMUCH | MADHYA PRADESH | 458441 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹25.0 L+₹6.8 L (37.3%)Rejected-Finance | L5 | Rejected-Finance Not being L1 |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
11 Nov 2024, 6:00 pmClosed
GE South Delhi Cantt-10
GE South Delhi Cantt-10
PROVN OF REWIRING OF JCOS/OR GOVT ACCN BLDG NO P-166(B COY) P-167 (C COY), P-162 (HQ COY) OF 18 GRENADIERS UNDER AGE E/M OF GE (SOUTH) DELHI CANTT-10
2024_MES_679352_1
GE/DS-91/2024-25
Open Tender
Civil Works
Item Rate
120 days
GE South Delhi Cantt
As per Tender Documents
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹74,000
6 Jan 2025
14 Oct 2024
14 Nov 2024
14 Oct 2024
11 Nov 2024
28 Oct 2024
Amount
Taking down carefully old U/S Aluminium / Copper point wiring (light, fan, socket or power point etc) complete with fittings such as switches, ceiling roses, pendants, sockets, regulators, etc and making good disturbed surfaces of walls including necessary touch up with the adjoining surface of disturbed area ie with OBD/colour wash/white wash as per existing finish complete all as specified and as directed.
M&L for point wiring with stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in but with through existing concealed PVC/ MS conduit and including replacement of unserviceable pressed steel terminal boxes of required size with top cover 3 mm thick plastic/laminated sheet of required color with screwed and cup washer with all accessories including 1.5 sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete all as specified for One light/Fan point controlled by one switch 5 Amps one way using cable (1.5 Sq mm for phase and neutral and 1.5 sqmm for earthing) and making good to disturbed surfaces of walls including necessary touch up with the adjoining surface of disturbed area i.e with OBD/colour work/white wash as per existing finishes complete all as specified and as directed. Note :- In existing conduit wiring new conduit will be provided where this is burnt/blocked/ damaged including bends/elbows/tees/ Junction boxes etc. and rates are deemed to be included in the unit rates as quoted above.
All as per item No 2 above but for One 3 pin socket outlet, 5/6 Amps on independent board complete.
All as per item No 2.01 above but on same board complete.
All as Item No 2 above, but for one socket outlet 5/15 Amps on Independent board with cables of size 2.5 Sqmm for phase and neutral and 2.5 Sqmm for earthing complete.
All as per item No 2 above, but for One light point controlled by two 2-way switches, with cable of 1.5 Sqmm complete.
S & F switch Modular type, 1 module 5/6 Amps SP one way complete all as specified and as directed.
S & F socket outlet 2-in-1, 5/6 Amps modular type 5 pin multi purpose complete all as specified and as directed.
S & F switch modular type 1M 15/16 Amps SP one way complete all as specified and as directed. Note:- One power point wiring shall be provided on one circuit for one point only.
S & F universal socket outlet 2-in-1 (multipurpose) 5pin 6/16 Amps modular type complete all as specified and as directed.
S & F ceiling rose surface Bakelite of size 65x25 mm two to three terminals complete all as specified and as directed.
S&F Electronic fan regulator, modular type 2M, complete all as specified and as directed.
S & F switch modular type 1 M 5/6 Amps SP 2 way complete all as specified and as directed.
S&F in replacement surface mounting LED Integrated Aluminium Batten luminarie Polycarbonate co-extusion tube for 20W LED light housing. Fixture should have minimum system lumen of 2000lm & minimum efficacy at system level >=95lumens/Watt, life of fixture 25K Hrs, CCT 4000-6500K with same lumens/w CRI>80, PF>0.90 THD<20% @ 240v AC and operating voltage range of 140-270V including all connections upto ceiling rose complete all as specified and as directed.
S&F in replacement LED bulk head in engineering plastic housing with clear prismatic diffuser, 10W WHITE including all accessories and connecting up with twin core flexible copper conductor cable complete all as specified and as directed.
S&F in replacement Wall mounted LED Integrated Batten 10 Watt-2 Ft White, indoor decorative PVC extruded LED batten integrated type complete all as speficied and as directed.
S&F in replacement batten of holder PVC insulated body complete all as specified and as directed.
S & F LED rechargeable Lamp of 12 Watt for fixing in batten holder/wall mounting/bulkhead point complete all as specifed and as directed.
S&F in replacement LED Building security light fitting 40 Watt including fabrication of GI bracket 25mm dia medium grade suitable for fixing of LED light fitting duly fixed with clamps, nut, bolts, & washers etc. complete all as specifed and as directed.
S&F steel body exhaust fan 450mm sweep, 230 Volts with louver and copper wound including necessary electric connection with appropriate size of PVC copper wire from ceiling rose/switch board to exhaust fan including fixing of nut-bolts of suitable size and making good the disturbed surface of wall with OBD/White wash to match with existing including taking down old exhaust fan and depositing to MES store yard complete all as specified and directed all as specified and as directed.
Supply, Installation, testing and commissioning 1200mm sweep BEE 5 star rated, Ceiling fan 35Watt Brush Less Direct Current (BLDC) Motor, Class of insulation : B, 3 Nos. Blade, 30 cm long down road, 2 Nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (CMM/W) minimum 6.85, Air delivery not less than 220 CMM, 280 RPM (tolerance as per IS:374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nuts bolts, washers, temperature rise =75 degree C (maximum), insulation resistance more than 2 mega Ohm, suitable for 230V, 50 Hz, single phase AC supply including taking down old ceiling fan and depositing to MES store yard complete all as specified and as directed .
S&F in replacement single pole and neutral metal clad sheet enclousre with 2 pin plug and socket complete with one no MCB SP 20 Amps as per site requirement of existing type cpmplete all as specified and as directed.
S&F in replacement VTPN DB triple pole and neutral 4 way for fixing 4P MCCB up to 125 Amps as incomer and MCBs as out goings with metal double door and IP 43 Protection and connecting including making good the disturbed surfaces in CM 1:3 and finished with the adjoining surface complete all as specified and as directed.
S&F in replacement MCCB 125 Amp 4 pole, 415V, 16KA complete all as specified and as directed.
S&F in replacement MCB SP 40 Amps 'B' series, breaking capacity 10 KA, 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc. complete all as specified and as directed.
S&F in replacement MCB DB SPN 12 Way double door type, (IP 43 Protection) flush mounting for MCBs complete all as specified and as directed.
S&F in replacement MCB SP 10 to 32 Amps 240 Volts, 10 KA, `B' curve, complete all as specified and as directed.
S&F in replacement MCB SPN 32Amps, 240 Volts, 10 KA, `B' curve, complete all as specified and as directed.
S&F water storage heater 25 litre capacity, 5 Star rated , vertical type, metal body, glass line, AC, Single Phase electric, 230 Volt, complete with heating element, thermostat, 3 core lead, plug top, safety valve, Non-Return Valve, temperature indicator including two nos. of PVC connection with brass nipple 15 mm x 600 mm long with ISI marked, braided with stainless steel wire , 16AMPS 30A Prcd Plug top with suitable 3 core wire for hot and cold for water connection with suitable nuts, bolts & washers including making electric connection and making good the disturbed surface including taking down old Geyser and depositing to MES store yard complete all as specified and as directed.
S&F in replacement PVC Pipe brass nipple 15 mm x 600 mm long for Hot & Cold water with brass nuts and washers, stainless steel for connection complete all as specified and as directed.
S&F in replacement 15mm bore medium grade galvanised iron pipe with all fittings fixed on wall/under floor and making connections including making good the disturbed surface to match with the existing surface complete all as specified and as directed.
S&F in replacement bib tap 15mm bore cast coper alloy CP fancy type scrwed to iron pipe and fixed complete all as specified and as directed.
S&F in replacement stopcock concealed Angle type 15mm bore of cast copper alloy CP fancy type screwed for iron pipe and fixed complete all as specified and as directed.
M&L for submain wiring in replacement PVC insulated FRLS single core with stranded copper cable of size 6 Sqmm in 2 runs and 6 Sqmm in one run for earth drawing through existing PVC concealed conduit of 25 mm dia complete all as specified and as directed. Notes:-(a) Two runs of main cable and one run of earth cable all-together shall be considered as one unit/length. (b) New conduit of suitable size with connected fittings will be laid, if there is damaged/blockage in existing conduit including making good the disturbed surfaces in CM 1:3 and finished with the adjoining surface and the rates are inclusive in quoted rates.
M&L for Earthing complete in replacement with galvanized steel earth plate 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate n.less than 1.5 m below normal ground level, connected to galvanized earth iron wire 4 mm as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints as shown in drgs and including excavation and earth work, GI pipe light grade 25mm bore of protection of GI wire from earth electrode, supply and laying charcoal dust, common salt, PCC (1:2:4) type B-1 Chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-1using 20 mm graded stone aggregate Reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia , PGI funnel and wire mesh , 20 mm dia GI Pipe light grade for watering complete all as shown in drg and connected to earth test point including testing on completion complete all as specified and as directed.
Supply ,laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strip armoured, electric power cable (heavy duty ) 1100 volt grade with stranded aluminium conductor of size 50 sqmm, 3.5 core on wall or in trenches including taking down old cable etc complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr in depth for laying cable etc and getting out in soft/loose soil complete all as specified and as directed.
M&L for sand filling under floors or in foundations including watering and consolidation etc complete all as specified and as directed.
Supply and laying bricks common burnt clay building sub class 'B' designation 75 including taking out old bricks etc complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed.
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
Supplying and laying including taking out G.I. tubing light grade of 50mm bore for encasing cables for mechanical protection , laid under plinth/ floors/ roads/ paths/ culverts or fixed on walls or concealed in walls or along the steel poles incl bends/clamps and all accessories etc complete all as specified and as directed.
Boring holes under road pavement by Bockey/ Manually in any type of soil for upto 50 mm bore size of pipe complete all as specified and as directed.
S&F Desert Cooler Steel body of 60 ltr tank capacity and 450mm fan motor size (for 4000 nominal capacity) nominal air delivery 4000 Cub Mtr/Hr with wood pad including all connections etc complete all as specified and as directed.
Note :- (i) The contract sum shall be after deducting the amount of Credit shown in Sch of Credit of this Tender. (ii) If any item of same description in nature is found to be entered as "double in BOQ" and the bidder quotes different rates against same item, then the rate quoted on lower side shall be applicable and higher rate will not be allowed to be paid in any circumstances. No claims on this account shall be entertained on a later date.
J V ENGINEERS / JAI SINGH (BID ID -3158848)
M/s Durga Traders (BID ID -3155394)
JINDAL ENTERPRISES (BID ID -3162833)
Surjit and Sons (BID ID -3156821)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .