| 1 | L1₹26.7 LAccepted-AOC ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | ₹26.7 L Quoted ₹28.2 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹29.3 L+₹1.1 L (3.74%)Rejected-Finance JAISALMER RAJASTHAN 345001 INDIA UDYAM RJ 18 0001538 | JAISALMER | RAJASTHAN | 345001 | ₹29.3 L+₹1.1 L (3.74%) | L2 | Rejected-Finance Not Lowest Bidder |
| 3 | L3₹32.9 L+₹4.7 L (16.6%)Rejected-Finance 202 NEW RAM VIHAR COLONY PINTO PARK MORAR GWALIOR 474005 | GWALIOR | GWALIOR | MP | 474005 | ₹32.9 L+₹4.7 L (16.6%) | L3 | Rejected-Finance Not Lowest Bidder |
| 4 | L4₹33.0 L+₹4.8 L (16.9%)Rejected-Finance | ₹33.0 L+₹4.8 L (16.9%) | L4 | Rejected-Finance Not Lowest Bidder |
| 5 | Rejected-Technical 77 KAILASH PURI BIKANER RAJASTHAN PIN 334001 | BIKANER | RAJASTHAN | 334001 | - | - | Rejected-Technical Not Meeting Eligibility Criteria |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
3 Sept 2022, 6:00 pmClosed
GE (AF) Jaisalmer
GE (AF) Jaisalmer
Repair/replacement of internal wiring of area-II including solar water heater, electric geyser and other E/M works at AF Stn Jaisalmer
2022_MES_543795_1
8843/GE/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Jaisalmer
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Jaisalmer
₹60,000
Yes
23 Sept 2022
6 Aug 2022
5 Sept 2022
6 Aug 2022
3 Sept 2022
20 Aug 2022
8 Aug 2022 - 13 Aug 2022
Amount
Taking down carefully existing unserviceable/perished conduit/ batten/ casing caping aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/ conduit/casing caping, switches, sockets, ceiling rose, pendent holder, lamp holders, bracket holders, light fittings, top sheet covers, fan regulators etc and making good the disturbed surfaces of wall/ceiling complete all as specified & directed.
Point wiring for one light point controlled by one way switch with 1.50 sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 Volt grade including 1.50 sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS, terminated & including suitable size module boxes for housing of modular switches, sockets, regulators including taking down old unserviceable point wiring complete all as specified & directed. Note : (i) Unit rates quoted by contractor shall be deemed to included for cutting chases in walls, ceilings and making good surfaces in cement and sand mortar (1:3) and finishing the surfaces to match with existing surfaces. (Make : Hylem /Anchor/Formica including machine screws and washer etc for fixing switches sockets etc including 1.5 sqmm copper conductor, standard (green colour earth), PVC insulated unsheathed earth wire to commen earth and connected to earth dolly as specified and directed.
All as per serial item No. 2.00 here-in-before but for one fan point controlled by one switch and regulator complete all as specified and directed.
All as per serial item No. 2.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5/6 Amp switch on same board complete all as specified and directed.
All as per serial item No. 2.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5/6 Amp switch on independent board complete all as specified and directed.
All as per serial item No. 2.00 here-in-before but for one bell/ buzzer point controlled by one bell push complete all as specified and directed.
Point wiring for one 3 Pin, 15 Amps socket outlet controlled by one 15 Amps switch on independent board with 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 volt grade including 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS, terminated & including suitable size module boxes for housing of modular switches, sockets, regulators complete all as specified and directed. Note : (i) Unit rates quoted by contractor shall be deemed to included for cutting chases in walls, ceilings and making good surfaces in cement and sand mortar (1:3) and finishing the surfaces to match with existing surfaces. (Make : Hylem/Anchor including machine screws and washer etc for fixing switches sockets etc including 4 sqmm copper conductor, standard (green colour earth), PVC insulated unsheathed earth wire to commen earth and connected to earth dolly as specified and directed.
Switch piano, flush type, Single Pole, one way, 6 Amp, 240 Volts (ISI Marked) fixed as in repair complete all as specified and directed.
Switch piano, flush type, Single Pole, one way, 15/16 Amp, 240 Volts (ISI Marked) fixed as in repair complete all as specified and directed.
Bell push, flush type, Single Pole, 5/6 Amp, 240 volt (ISI Marked) fixed as in repair complete all as specified and directed.
Bell Multi Music Type, AC supply, Single Pole, 240 volt (ISI Marked) fixed as in repair complete all as specified and directed.
Socket outlet 2 in 1, 5 pin, 15/16 Amps, flush type, 240 Volts (ISI Marked) fixed as in repair complete all as specified and directed.
Socket outlet, 2 in 1, 3 pin, 5/6 Amp, flush type, 240 Volts (ISI Marked) fixed as in repair complete all as specified and directed.
Switch piano, flush type, Single Pole, two way, 6 Amp, 240 Volts (ISI Marked) fixed as in repair complete all as specified and directed.
Ceiling rose surface bakelite with two or three terminal PVC/Polycarbonate, isolated body (ISI Marked), 240 volts in repair complete all as specified and directed.
Lamp holder, PVC / Polycarbonate type (angle/batten) with back plate suitable for batten fittings fixed as in repair complete all as specified and directed.
Stepped type electronic fan regulator, flush type and connecting up, 120 watt, 240 volt (ISI marked) fixed as in repair complete all as specified and directed.
MCB Protected Socket (Modular AC Box, Metal clad box) Two Module, Single Pole, 20 Amps, repturing capacity 10 kA and neutral enclosure in sheet steel with a two pin and earth plug and socket including taking down old unserviceable complete all as specified and directed.
Surface and wall mounted 10 watt LED bulk head fitting in engineering plastic housing with clear prismatic diffuser complete with all accessories and connecting up complete with 3 core flexible cable white of size 23/0.0076 including taking down old unserviceble LED fittings complete all as specified and directed.
Decorative ultra slim round profile LED tube light fittings of capacity 10 watt LED 6000 K, two feet, basic all purpose surface and wall mounted LED batten with extruded polycarbonate housing & integrated electronic driver including taking down old unserviceble LED fittings complete all as specified and directed.
Decorative ultra slim square profile LED tube light fittings of capacity 20 watt LED 6500 K, four feet, basic all purpose surface and wall mounted LED batten with extruded polycarbonate housing & integrated electronic driver including taking down old unserviceble LED fittings complete all as specified and directed.
Sub main wiring with 2.50 sqmm, Single Core, PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 volts grade conforming to IS 694 including 2.50 Sqmm Single Core PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 Volt grade as continuous earth wire in green colour drawn through in existing surface/recessed steel/PVC/steel rigid conduit including taking down old unserviceable submain wiring complete all as specified. Note : Two run of 2.50 sqmm cable and one run of 2.50 sqmm cable as earth wire continuity conductor shall be measured & paid as one unit.
Sub main wiring with 4.00 sqmm, Single Core, PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 volts grade conforming to IS 694 including 4.00 Sqmm Single Core PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 Volt grade as continuous earth wire in green colour drawn through in existing surface/recessed steel/PVC/steel rigid conduit including taking down old unserviceable submain wiring complete all as specified. Note : Two run of 4.00 sqmm cable and one run of 4.00 sqmm cable as earth wire continuity conductor shall be measured & paid as one unit.
Sub main wiring with 6.00 sqmm, Single Core, PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 volts grade conforming to IS 694 including 6.00 Sqmm Single Core PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 Volt grade as continuous earth wire in green colour drawn through in existing surface/recessed steel/PVC/steel rigid conduit including taking down old unserviceable submain wiring complete all as specified. Note : Two run of 6.00 sqmm cable and one run of 6.00 sqmm cable as earth wire continuity conductor shall be measured & paid as one unit.
MCCB, 4 Pole, 63 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC supply, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed.
MCCB, 4 Pole, 100 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC supply, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed.
MCCB, 4 Pole, 125 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC supply, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed.
MCB, Single Pole, 6 to 32 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 240 Volt grade, AC supply, 50 Hz and making connections using suitable size copper lugs/thimbles including complete, all as specified & directed.
MCB, SPN, 40 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 240 Volt grade, AC supply, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete all as specified & directed.
MCB, TP, 63 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 415 Volt grade, AC supply, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete all as specified & directed.
MCB, TPN, 63 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 415 Volt grade, AC supply, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete all as specified & directed.
Sheet metal enclosure powder coated single phase DB SPN 4 ways and neutral 240 Volts, AC supply, 50 Hz, with 200 Amps rated bus bar Double Door (IP-43 IK 09 with metal door) suitable for fixing of MCBs including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces including taking down old unserviceable DB complete all as specified and directed.
Sheet metal enclosure powder coated single phase DB SPN 8 ways and neutral 240 Volts, AC supply, 50 Hz, with 200 Amps rated bus bar Double Door (IP-43 IK 09 with metal door) suitable for fixing of MCBs including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces including taking down old unserviceable DB complete all as specified and directed.
Sheet metal enclosure powder coated single phase DB SPN 12 ( ways and neutral 240 Volts, AC supply, 50 Hz, with 200 Amps rated bus bar Double Door (IP-43 IK 09 with metal door) suitable for fixing of MCBs including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces including taking down old unserviceable DB complete all as specified and directed.
Sheet metal enclosure powder coated single phase DB VTPN 4 ways and neutral 415 Volts, AC supply, 50 Hz, with 200 Amps rated bus bar Double Door (IP-43 IK 09 with metal door) suitable for fixing of MCBs including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces including taking down old unserviceable DB complete all as specified and directed.
Flameproof Fluorescent luminaire, Tube light fitting, 1 X 16 watt including LED tube, flame Proof, CMRI certified recommended for gas vapor group of IIA & IIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holder, connector block, etc and all accessorie pre-wired and incuding connecting up with twin core twisted flexible copper conductor cable with suitable size including disconnected & taking down old unserviceable light complete all as specified and directed.
LED Panel 36 watt with 2ft x 2 ft slim panel 595X595mm with super bright recess mounting LED Slim ceiling light with white powder coated extruded aluminium housing and highly efficient light smoothing optics to deliver superior illumination including LED driver and fixing in recess ceiling suitable size of aluminium strip size as required for fixing of LED fitting complete with all accessories prewired fixed on ceiling and connecting up complete with 3 core flexible cable of size 23/0.0076 including taking down old unserviceable fittings complete all as specified and directed.
Single phase electronic energy meter with LCD display of rating 5-30 Amp class 1.0, 240 Volt, 50 Hz counter type display with transparent hinge including connection from SPN to meter with 6 Sqmm copper stranded conductor including earth wire including disconnecting & taking down old unserviceable meter complete all as specified and directed.
Supply, install, testing and commissioning of LT panel size 800 mm x 600 mm x 150 mm enclosures cubical weather and vermin proof totally enclosed made out of 1.60 mm thick CRCA sheet machine pressed of suitable size to operate on 3 phase 4 wire system 415 Volts, 50 Hz double door with front openable and PVC acrylic glass cover suitable size for checking of meter reading without opening door with locking arrangement incl inner shutters for mounting switch gear etc, suitable arrangement for fixing of electrical meter and SPN 40 to 63 Amp including pre wiring from Bus bar to Meter and Meter to MCB SPN (for pre wiring use 6.00 Sqmm Single core copper cable and suitable size of lugs for connecting from Busbar to meter and meter to MCB SPN) including bottom gland plate with sufficient numbers of circular cable entry holes, including disconnected and taking down old panel and prewired complete as per drawing with masonary work for fixing in wall duly powder coated with comprising of the following :- INCOMING: (i) MCCB 63 Amps 4 Pole, 415 Volt, repturing capacity 25 kA, adjustable thermal & fixed magnetic setting - 01 Nos. (ii) Phase indicating lamp LED type with HRC fuse – 1 Set of three. (iii) ON/OFF indicating lamp on incomer feeder for status of feeder - 02 Nos (iii) Aluminium bus bar 200 Amps capacity with bus bar supports, DMC/SMC insulators of CPRI approved of suitable length insulated heavy heat shrinkable sleeves etc - 04 Nos. OUTGOING (i) MCB SPN 32 Amp, 415 Volt grade, repturing capacity 10 kA - 04 Nos, (ii) Single phase electronic energy meter with LCD display of rating 5-30 Amp class 1.0, 240V 50 Hz counter type display with transparent hinge including connection from SPN to meter with 6 Sqmm copper stranded conductor including earth wire complete all as specified and directed - 04 Nos
LED Adore 15 watt base capacity B22, STAR ball Lamp lumen output 1425, color temp 6500K in repair complete all as specified and directed.
Switch flame proof rotary type with termination box in LM6, 6/16 Amps, Single pole, 250 volts grade, AC supply, 50 Hz in repair complete all as specified and directed.
LED 12 watt downlighter recess mounting made out of thermally conductive engineering plastic finished in white colour having in built driver, high transculet frosted optically diffuser, glare free light, IP-20, square/round shape and white/warm white colour (as per site requirement) having lumen output of 1800 lumens (in CDL/Cool white colour) including connecting up with twin core twisted flexible copper conductor cable with suitable size including disconnected & taking down old unserviceable light fitting complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No. 3 of SSR Part-I and connection to main switch board/Test point/ panel/ equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exceeding 50 metre, charcoal and salt in alternate layer 15cm thick all around the earth plate electrode, Mild Steel Funnel with wire mesh, 20mm bore, GI pipe medium grade, 1.50 metre long for watering and 15mm bore, GI pipe light grade, 7.50 metre long for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:2:4) type B-1, using 20mm graded stone aggregate with angle iron 40x40x5mm frame 60mm thick RCC cover with 6mm steel bars 100mm centre to centre both ways etc including dismantling & taking out old existing unserviceable earthing complete all as specified & as directed. Note : (i) PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) If earth resistance of earthing is not found satisfactory it will be redone by the contractor on his risk and cost.
LED box type integrated batten 40 watt having aluminum extruded housing in white powder coated finish with high translucent PC cover, elegant design, IP 20 protection, dimensions of the fitting shall be not less than 1200 mm (length) x 40mm (width) x 63 mm (height). Lumens out put of the fitting shall be not less than 4400 Im, CCT 5700-6500K, surge protector 4 KV, PF˃=0.95, separate detachable type electronic constant current drivers for easy replacement and maintenance, THD˂10% necessary mounting arrangements. The manufacturer of the fixture shall have in house NABL accredited Lab and must produce certificate of the same alongwith LM-79/LM-80/Test report and including connecting up with twin core twisted flexible copper conductor cable with suitable size including disconnected & taking down old unserviceable light fitting complete all as specified and directed.
LED street light of capacity 30 watt with in built driver having pressure die cast aluminum housing, IP-66 having efficiency of ≥ 100 lumens/watts, operating voltage 120-270 volts, P.F≥ 0.95, THD ˂ 10%, suitable for 30 to 40 mm O.D mounting pipe and suitable for mounting on wall/pole with necessary mounting arrangements) including connecting up with three core twisted flexible copper conductor cable with suitable size, mounting pipe/bracket, nut, bolts and accessories including disconnected & taking down old unserviceable light fitting complete all as specified and directed.
Attending complaints of no supply in light or power circuit due to burning/disconnecting of any wire i.e neutral phase or tripping of MCB or unserviceability of any item such as switch socket MCB etc, rectification of fault including any petty repair required to restore the electric supply for checking of existing electrical items for contineous electric supply including carrying out minor repairs such as changing of fuse, small pieces of wires etc. carrying out repairs such as tightening of loosen electric connections, nuts, bolts screws or switches, sockets, switch board, ceiling fans/exhaust fans etc. required to make the item functional during 0900 hours to 1800 hours by deploying electrician alongwith helper including necessary T&P complete all as specified and directed. Note :- (a) Replacement of electrical fitting/fixtures for supply & fixing shall be measured and paid for separately under respective items. (b) Repairs/faults in any one quarter/ one occupancy shall be considered as one complaint (one measuring unit) even if repair is involved in more than one light point or fitting, however supply & fixing of fitting/ fixtures replaced shall be measured & paid separetely. (c) Number of complaint may varry day to day contractor shall quote their rates accordingly. (d) In case of failure on the part of contractor for attending complaint as penalty shall be imposed and recovered in Rs. 200/- Each complaint as specified. (e) Contractor shall ensure that the deployed electrician & helper with carry functional and live mobile phone connection while on duty and will be on contact with JE incharge/ Engineer-in-Charge. (f) Contractor shall be responsible for collection of all ON line complaints and hand over the same JE E/M and to date the states ON line after attending /complete of the Job.
Servicing of Solar Water Heater including cleaning of main tank, Solar power module/ Solar Panel Reflectors including checking/ repairing leakage of inlet/ outlet pipes of Solar Water Heater complete all as specified and directed. (Make :- Solar Maxx/ Solchrome/Tata BP).
Solar Panels or collectors suitable for Solar Water Heater Capcity 500 Ltr per day including its installation with support of angle iron, welding works, nuts, bolts etc with other material required to complete the work including testing after installation including taking down old unserviceable complete all as specified and directed.
Solar evacuated tube of Solar Water Heater as per existing suitable for 330 LPD complete with washer etc including taking down old unserviceable complete all as specified and directed.
Solar Water Heating rod of capacity 3 KW including taking down old unserviceable complete all as specified and directed.
Sheet metal enclosure for DBs when MCBs to be used 2 way SPN including taking down old unserviceable complete all as specified and directed.
Unplasticised PVC (uPVC) 25mm bore pipes of pressure rating 10 Kgf/Sqcm fixed complete to walls, ceilings or in floors etc., including fittings as bends, elbow, reducer, sockets including taking down old unserviceable pipe complete all as specified and directed.
Unplasticised PVC (uPVC) Gate valve/Check valve screwed both ends with iron wheel head, screwed down high pressure ISI marked for 25mm bore pipe line including taking down old unserviceable complete all as specified and directed.
Rotational moulded polyethylene water storage tanks 1000 Litre capacity triple layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. including dismentling & taking down old unserviceable water tank capacity 1000 litre complete as specified in SSR Part-I.
Rotational moulded polyethylene water storage tanks 500 Litre capacity triple layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. including dismentling & taking down old unserviceable water tank capacity 500 litre complete as specified in SSR Part-I.
Solar Water heating tank upto capacity 300 Ltr/500 Ltr made up of stainless steel food grade type model No. SS-304-2B including taking down old unserviceable complete all as specified and directed.
Galvanized steel water tubing medium grade of 15mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors, including taking up or down old unserviceable steel water tubing and connections of 15mm bore, complete all as specified and directed.
Galvanized steel water tubing medium grade of 20mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors, including taking up or down old unserviceable steel water tubing and connections of 20mm bore, complete all as specified and directed.
Galvanized steel water tubing medium grade of 25mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors, including taking up or down old unserviceable steel water tubing and connections of 25mm bore, complete all as specified and directed.
Gun metal globe or gate valve screwed both ends with iron wheel head, screwed down high pressure ISI marked for 25mm bore pipe line including taking down old unserviceable complete all as specified and directed.
Gun metal globe or gate valve screwed both ends with iron wheel head, screwed down high pressure ISI marked for 20mm bore pipe line including taking down old unserviceable complete all as specified and directed.
Gun metal globe or gate valve screwed both ends with iron wheel head, screwed down high pressure ISI marked for 15mm bore pipe line including taking down old unserviceable complete all as specified and directed.
Comprehensive Annual maintenance of Storage type Electric, Water Heater (Geyser) of storage capacity 25/ 35/50 Ltrs comprising of the following work at different locations of any make complete all as specified and directed. (a) Inspection, taking down , opening (dismantling), brushing, cleaning of storage tank and painting internally with one coat of proprietery bituminous composition not liable to impart test or otherwise contaminate the water. (b) Examining water tightness of storage tank after cleaning. (c) Carryout operation of all stock cocks, pressure reducing valves etc to ensure free movement of the working parts. (d) Replace washers and glands of all taps and ball valves to ensure water tightness. (e) Inspect overflow/ vent pipes and remove blockage obstruction if any. (f) Check and correct earth continuity of electrical items. (g) Check maintain and refitting the thermostat and test its functioning. (h) Checking and adjustment of pressure reducing valves. (j) Checking of dead weight type high pressure release valves (PRV) by removing dead weight protection , cleaning the seat and ensuring that the vest hole is not blocked/ choked. (k) Visual examination of fusible plug to ensure its intactness. (l) Descaling of immersion type heating element and cleaning with diluted hydrochloric acid or clear pedette. (m) Replacement/ Repair of neon lamp/ indicator lamp. (n) Testing of Geyser after repairs.
Taking down of storage type electric water heater (Geyser) of storage capacity 25/35/50 Ltrs any make and type for repair tasks at different locations and refixing the same after repair complete all as specified and directed.
Safety valve/ high pressure valve (ISI marked) including taking down old unserviceable valve complete all as specified and directed. Make :- Toshiba/ Havells/ Venus/ Godrej
Thermostate (ISI marked) suitable for any make and type of Geysers including taking down old unserviceable complete all as specified and directed.
Heating element suitable for water storage heater (Geyser) of capacity 25/35 Ltrs cpacity as per existing make and model of ISI mark including making all connections including taking down old unserviceable complete all as specified and directed.
Heating element suitable for water storage heater (Geyser) of capacity 50 Ltrs cpacity as per existing make and model of ISI mark including making all connections including taking down old unserviceable complete all as specified and directed.
Steel geyser assembly (Appratus plate) suitable for water storage heater (Geyser) of capacity 25/35 Ltrs cpacity as per existing make and model of ISI mark including making all connections including taking down old unserviceable complete all as specified and directed. Make : Toshiba/ Havells/ Venus/ Godrej
Steel geyser assembly (Appratus plate) suitable for water storage heater (Geyser) of capacity 50 Ltrs cpacity as per existing make and model of ISI mark including making all connections including taking down old unserviceable complete all as specified and directed. Make : Toshiba/ Havells/ Venus/ Godrej
PVC connection pipes inlet and outlet (for hot and cold connection) with brass hexagonal adapters both side, suitable for 15mm dia pipe 450mm long fixed as repair complete all as specified and directed.
CP connection pipes inlet and outlet (for hot and cold connection) with brass hexagonal adapters both side, suitable for 15mm dia pipe 450mm long fixed as repair complete all as specified and directed.
Brass Non return valve 15/20mm bore, ISI marked fixed as repair complete all as specifie and directed.
Insulation material (Glass wool) for Geysers of any capacity fixed as in repair complete all as specified and directed.
15mm dia stop cock, cast copper alloy chromium plated, screwed down high pressure with capstoan head screwed both ends for iron pipe or union fixed as repair complete all as specified and directed.
Refixing loose Geysers of any capacity to walls by regrouting of bolts and refixing the Geysers complete with all necessary pipe connection sand making good the disturbed wall surface all as specified and directed.
Supply, installation and testing electric water heater, storage type, steel body with copper inner tank and heating element 2 KW, capacity 25 litre BEE 5 star rated complete with all assessories such as safety valve, thermostate, NRV, PVC connection pieces etc including taking down old unserviceable complete all as specified and directed.
Three pin Top plug 15 Amp, 240 volt (ISI Marked) suitable for Geyser including taking down old unserviceable complete all as specified and directed.
M/s Ramesh & Company
AUTOMATION AND SWITCHGEAR CONTROL
Manisha Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .