Tender Value
₹50.7 L
EMD Value
₹1.0 L
Closing Date
11 Sept 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
Capital (Works)
Above/Below/Par
POWER
15 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. As detailed in Para 10.2 of Tender Form (Second sheet) of Part 1 of attached GCC-2022.
FOR ALL TYPE FIRM AND ALL VALUE OT TENDER: The contractor should have valid Electrical contractor license issued by Govt. and submit along with tender document.
Experience in similar nature of work:- The tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender. As detailed in Para 10.1 of Tender Form ( Second sheet) of Part 1 of attached GCC-2022.
Defination of Similar Work :- Any electrical work related to HT/LT installation.
23 conditions · 6 needing a document upload
Tender document and all the uploaded supporting documents must be digitally signed by the authorized signatory for tender, in token of their acceptance.
DOCUMENT REQUIRED FOR Sole ProprietorshipFirm : All documents in terms of Para 10 of theTender Form (Second Sheet) of GCC APRIL-2022with including correction slip upto date.
DOCUMENT REQUIRED FOR HUF : (I) A copy ofnotarized affidavit on Stamp Paper declaring thathe who is submitting the tender on behalf of HUFis in the position of 'Karta' of Hindu UndividedFamily (HUF) and he has the authority, powerand consent given by other members to act onbehalf of HUF. (II) All other documents in termsof Para 10 of the Tender Form (Second Sheet) ofGCC APRIL-2022 with including correction slipupto date
DOCUMENT REQUIRED FOR Partnership Firm: Alldocuments as mentioned in para 18 of the TenderForm (Second Sheet)of GCC APRIL-2022 withincluding correction slip upto date
DOCUMENT REQUIRED FOR Company registeredunder Companies Act2013 : (i) The copies ofMOA (Memorandum of Association) / AOA(Articles of Association) of the company. (ii) Acopy of Certificate of Incorporation (iii) A copy ofAuthorization/Power of Attorney issued by theCompany (backed by the resolution of Board ofDirectors) in favour of the individual to sign thetender on behalf of the company and createliability against the company. (iv) All otherdocuments in terms Para 10 of the Tender Form(Second Sheet) of GCC APRIL- 2022 with allcorrection slip
DOCUMENT REQUIRED FOR LLP (Limited LiabilityPartnership): (i) A copy of LLP Agreement (ii) Acopy of Certificate of Incorporation (iii) A copy ofPower of Attorney/Authorization issued by theLLP in favour of the individual to sign the tenderon behalf of the LLP and create liability againstthe LLP. (iv) An undertaking by all partners of theLLP that they are not blacklisted or debarred byRailways or any other Ministry / Department ofthe Govt. of India from participation in tenders /contracts as on the date of submission of bids,either in their individual capacity or in anyfirm/LLP or JV in which they were / arepartners/members. Concealment / wronginformation in regard to above shall make thecontract liable for determination under Clause 62of the Standard General Conditions of Contract.(v) All other documents in terms of Para 10 ofthe Tender Form (Second Sheet)of GCC APRIL-2022 with including correction slip upto date
DOCUMENT REQUIRED FOR Registered Society &Registered Trust :(i) A copy of Certificate ofRegistration (ii) A copy of Memorandum ofAssociation of Society/Trust Deed (iii) A copy ofPower of Attorney in favour of the individual tosign the tender documents and create liability No No Allowed(Mandatory) against the Society/Trust. (iv) A copy of Rules &Regulations of the Society (v) All otherdocuments in terms of Para 10 of the TenderForm (Second Sheet)of GCC APRIL-2022 withincluding correction slip upto date
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Jaipur- Electrical work in connection with provision of 3 nos. storey above newly constructed OPD Pharmacy and cafeteria with one floor of left wing of central hospital
EL-JP-18-2026-27~NWR
EL-JP-18-2026-27
Open
Works - General
12 Months
Jaipur, Rajasthan
₹0
₹1.0 L
20 Aug 2026
20 Aug 2026
28 Aug 2026
103 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 50,71,246.38 | ||
| — | 540.00 | — | — | ||
| Supply of material and wiring of LP/TP/FP/Ex.Fan point with 1.5sqmm PVC single core multi-stranded copper wire insulated concealed in stone/brick masonry wall in19/20 mm PVC conduit with 1.5sqmm PVC wire insulated copper for earth wire 1-way/2-way switch 5/6A as required and good quality ceiling rose including connection (MODULAR) as per spec | — | — | — | 2,00,836.8 | |
| — | 440.00 | — | — | ||
| Supply and fixing 5/6A plug 5-pin 230V with switch, board and wiring with 2.5sqmm PVC CU cable as per spec. | — | — | — | 84,383.2 | |
| — | 130.00 | — | — | ||
| Supply and fixing 15/16A power socket with switch on flush type sheet metal box and connection as per spec | — | — | — | 24,801.4 | |
| — | 40.00 | — | — | ||
| Supply and fixing of Metal Clad Plug Socket 20A single phase with 32A MCB including fixing and sheet metal enclosure box with one 20A plug top (Ray roll type) to be supplied with board as per spec. | — | — | — | 30,986.4 | |
| — | 80.00 | — | — | ||
| Supply and fixing ceiling of fan regulator electronic type 5-step as per spec | — | — | — | 25,383.2 | |
| — | 60.00 | — | — | ||
| Supply and fixing 12 module plate for fixing of switches and sheet metal box of good quality concealed fixing of MS/PVC | — | — | — | 15,282 | |
| — | 70.00 | — | — | ||
| Supply and fixing 8 module plate for fixing of switches and sheet metal box of good quality concealed fixing of MS/PVC | — | — | — | 16,187.5 | |
| — | 70.00 | — | — | ||
| Supply and fixing 6 module plate for fixing of switches and sheet metal box of good quality concealed fixing of MS/PVC | — | — | — | 11,526.2 | |
| — | 70.00 | — | — | ||
| Supply and fixing 4 module plate for fixing of switches and sheet metal box of good quality concealed fixing of MS/PVC | — | — | — | 9,055.2 | |
| — | 2420.00 | — | — | ||
| Wiring of sub-main with 2x2.5 sqmm PVC insulated, single core, multi-stranded copper wire in PVC conduit concealed and 1.5sqmm PVC insulated, single core, multi-stranded copper wire for earth wire as per spec | — | — | — | 1,75,982.4 | |
| — | 1000.00 | — | — | ||
| Wiring of sub-main with 2x4 sqmm PVC insulated, single core, multi-stranded copper wire in PVC conduit concealed and 1.5sqmm PVC insulated, single core, multi-stranded copper wire for earth wire as per spec | — | — | — | 1,33,920 | |
| — | 300.00 | — | — | ||
| Wiring of sub-main with 2x6 sqmm PVC insulated, single core, multi-stranded copper wire in PVC conduit concealed and 2.5sqmm PVC insulated, single core, multi-stranded copper wire for earth wire as per spec | — | — | — | 40,419 | |
| — | 30.00 | — | — | ||
| Wiring of shed LP/TP in covered shed with 1.5sqmm copper wire PVC insulated & multi-stranded in PVC conduit, ISI mark 1.5mm thick, size 19/20mm dia and 1.5sqmm PVC insulated multi stranded copper earth wire with ceiling rose fixed with saddles or tied properly and junction box as per spec. | — | — | — | 6,057.6 | |
| — | 200.00 | — | — | ||
| Fixing of LED light fitting with PVC insulated, multi-stranded copper wire for connection as per site requirement as per spec | — | — | — | 14,986 | |
| — | 80.00 | — | — | ||
| Fixing of ceiling fan with clamp, hooks and down rod as per requirement and connection as per spec | — | — | — | 18,246.4 | |
| — | 10.00 | — | — | ||
| Supply & fixing of 7W LED Tilt able Mirror light in Aluminium body with glass cover in sand gray finish in 6000k, Approx dimension 320x78x28mm, catalogue no. LLT 004 (make Ledlum, Bajaj, Wipro or equivalent) as per spec. | — | — | — | 8,968 | |
| — | 10.00 | — | — | ||
| Supply and providing LED foot light in square SS body complete with 1 No. 1W Yellow LED and step down transformer as per spec | — | — | — | 10,538.6 | |
| — | 10.00 | — | — | ||
| Supply and fixing of 2W, 12V LED wall lamp with flexible pipe & an off switch on base which is made of stainless steel and head made of brass with stainless steel finish complete with driver as per spec | — | — | — | 13,055.2 | |
| — | 80.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED sleek-surface mounted round down light 18 watt etc. | — | — | — | 1,92,676.8 | |
| — | 30.00 | — | — | ||
| Supply, fixing and connecting modular type exhaust fan 225/250mm as per spec | — | — | — | 24,992.1 | |
| — | 2.00 | — | — | ||
| Transportation, installation, testing and commissioning of water cooler including with water connection angle valve as per spec | — | — | — | 5,638.9 | |
| — | 1.00 | — | — | ||
| Dismantling & Re-installation of Existing 5.5 TR Air-Conditioning Plant Outdoor unit along with all Accessories. Before dismantling store refrigerant in compressor and at Re-installation as per railway requirement. | — | — | — | 38,500 | |
| — | 1.00 | — | — | ||
| Dismantling, Transportation and re-installation of some PV modules of 50kw solar roof top system, including supply of DC wire , connector , cable Tie, Trench & wire and all other accessories. | — | — | — | 48,500 | |
| — | 1.00 | — | — | ||
| Dismantling, Transportation and re-installation of Solar Water Heater Plant 1000/500 LPD | — | — | — | 18,000 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing & commissioning of 11KV 250 KVA outdoor type CSS consisting of 2 LBS and 1 VCB at side (630Amps. 20KA) 250 KVA dry type transformer and 400 Amps ACB at LT side as per spec. | — | — | — | 22,83,436.25 | |
| — | 1.00 | — | — | ||
| Supply fixing testing and commissioning of RMU single extensible RMU consisting of 2 Nos. 630A Load break switches and 1 No. 630A TEE off with SF6 circuit breaker and with O/C + E/F relay type VIP35 with SF6 gas pressures indicator 11kV, 21kA 3-way RMU type ring master as per spec | — | — | — | 3,05,502.8 | |
| — | 2.00 | — | — | ||
| S&F of LT distribution Panel of 2x400Amp MCCB incoming and 2 Nos 200Amp, 2Nos 100Amp MCCB outgoing with energy meter. including Copper bus bar and connections as per spec. | — | — | — | 1,86,701.4 | |
| — | 13.00 | — | — | ||
| Supply and Providing Copper Plate Earthing 4meter deep, copper plate size 600x600x3mm as per spec. | — | — | — | 76,631.1 | |
| — | 170.00 | — | — | ||
| Supply and fixing of Copper Earth Flat strip size 25x3mm as per spec | — | — | — | 47,649.3 | |
| — | 20.00 | — | — | ||
| Supply and Providing GI Pipe Earthing of 4meter length as per spec | — | — | — | 38,552 | |
| — | 13.00 | — | — | ||
| Supply, fixing, testing and commissioning of RCBO 63A, Four pole, 30mA with Earth leakage, overload and short circuit protection as per spec | — | — | — | 44,979.35 | |
| — | 13.00 | — | — | ||
| Supply, fixing, testing and commissioning of Distribution Board double door, 3-phase and neutral with incoming 63A 4-pole MCB and outgoing 12Nos. MCB 6-32A single pole as per spec. | — | — | — | 68,266.12 | |
| — | 3.00 | — | — | ||
| Supply, fixing, testing and commissioning of RCBO 25A, double pole, 30mA with Earth leakage, overload and short circuit protection as per spec | — | — | — | 6,950.85 | |
| — | 2.00 | — | — | ||
| Supply, fixing, testing and connecting of Distribution Board with incoming 32A, single phase, DP MCB and outgoing 8Nos. single pole MCB 6-16A as per spec | — | — | — | 5,988.26 | |
| — | 3.00 | — | — | ||
| Supply, fixing, testing and commissioning of fabricated Feeder Pillar distribution box made of MS sheet 1.6mm thick size 600x300x600mm with suitable MS stand Copper bus bar of 200A capacity and 2x63A MCB 4 pole as per spec | — | — | — | 14,065.53 | |
| — | 10.00 | — | — | ||
| Supply fixing and commissioning of HT XLPE heat shrinkable type cable end box indoor type size 50 to 185 sqmm as per spec | — | — | — | 48,772.2 | |
| — | 200.00 | — | — | ||
| Laying testing commissioning of 11/33kv HT XLPE cable in air ground /in trench spun pipe with transportation from main depot to required site as per spec. | — | — | — | 19,628 | |
| — | 2100.00 | — | — | ||
| Laying of LT/HT Cable IN AIR / Pipe/ Wall/tray as per spec | — | — | — | 46,515 | |
| — | 200.00 | — | — | ||
| Supply & laying of HDPE Pipe 25 mm ISI marked for electrical work along it with accessories as required T -bent ,clamps, elbow etc. in recess including cutting the wall, and making good the same as per spec. | — | — | — | 13,266 | |
| — | 900.00 | — | — | ||
| Supply and laying of HDPE pipe conforming to IS 4984:1995, 75/80mm dia wall thickness 3 mm PN-4 under the road/air. The work invloves laying of HDPE pipe. | — | — | — | 96,561 | |
| — | 300.00 | — | — | ||
| Digging and filling of trench size 0.4x1.2 mtr as per spec (trench work may be on kuchha/pucca and land and all type of soil as per site requirement and without protective layer of brick) surface of trench shall be made good in all respect and satisfaction of site engineer | — | — | — | 13,275 | |
| — | 300.00 | — | — | ||
| Horizontal Directional Drilling (HDD)/Boring and trenchless cabling. Supply, transportation and insertion of self lubricated HDPE pipe and laying of cables in boring under the track /road /ground/ masonary building by using self lubricated HDPE pipe of 120mm outer dia and 103.5mm inner dia in the bore and laying of cables in the bore under the track/road/ground/masonary building. The depth of horizontal boring should be minimum 1 mtr from rail flange/road level/ground, as per site requirement. | — | — | — | 3,86,901 | |
| — | 4.00 | — | — | ||
| "Supply, installation, testing & commissioning of VTPN type metal double door type 8 way DB with having 01 No. 250 Amp., 4 pole MCCB, 36 KA as incomer & 8 Nos. TP MCB, 10 KA 'C' curves, 40-63 Amp. Cap. as utgoing having suitable IP-54, IK-09 protection" | — | — | — | 1,79,534.64 | |
| — | 20.00 | — | — | ||
| Supply, laying and commissioning of IS mark FRLS unsheathed insulated multistrand sing core copper conductor cable in existing metal conduit pipe, its accessories, metal box recessed in wall etc of size 10sqmm | — | — | — | 1,661.8 | |
| — | 30.00 | — | — | ||
| Supply and Fixing of PVC conduit pipe size 25mm dia thickness 1.6mm ISI marked concealed in wall as per spec | — | — | — | 719.4 | |
| — | 4.00 | — | — | ||
| Supply of material and wiring of LP/TP/FP/Ex.Fan point with 1.5sqmm PVC single core multi-stranded copper wire insulated concealed in stone/brick masonry wall in19/20 mm PVC conduit with 1.5sqmm PVC wire insulated copper for earth wire 1-way switch 5/6A and good quality three plate ceiling rose including connection as per spec | — | — | — | 1,453.48 | |
| — | 2.00 | — | — | ||
| Supply and fixing of 5/6A 5/6-pin socket with switch on existing MS board as per spec | — | — | — | 52.98 | |
| — | 2.00 | — | — | ||
| Supply and fixing of 15/16A 6-pin power socket with switch on new MS board as per spec | — | — | — | 125.34 | |
| — | 2.00 | — | — | ||
| Supply and fixing of MS board in recessed size 175x100x50mm as per spec | — | — | — | 108.78 | |
| — | 30.00 | — | — | ||
| Supply, erection, fixing and commissioning of auxiliary cable tray 300mm size made of MS angle 35x35x5mm and MS flat 35x5mm as per spec | — | — | — | 11,184.3 | |
| — | 40.00 | — | — | ||
| Laying of LT cable size 3.5/4x16sqmm to 3.5/4x240sqmm as per spec | — | — | — | 3,841.6 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC April 2022
ATTACHMENT
Advance Correction Slip No 1 to 12
ATTACHMENT
ESTD-18-2026-27.pdf
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27_04_22.pdf
ATTACHMENT
AdvanceCorrectionSlipsNo1to12GCC-2022.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].