Executive Engineer JDA Division No.1
Executive Engineer JDA Division No.1, RHC ,Jammu
Electrification of 21 No halls at North Block A1 and South Block A2 at Bahu Plaza Jammu (2nd Time)
2022_HAUDD_164692_1
JDA-I/2021-22/e-NIT/154 Dated 16.03.2022
Open Tender
Electrical Works
Item Rate
30 days
Jammu
As per SBD
3 documents required · 3 mandatory
₹500
Vice Chairman, Jammu Development Authority
₹12,480
6 Apr 2022
16 Mar 2022
31 Mar 2022
16 Mar 2022
31 Mar 2022
16 Mar 2022
90 days
Amount
Wiring for light point/fan point/exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit with modular switch,modular plate,suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed medium calss PVC conduit as required. 2 x 1.5 sq.mm +1x1.5 sq.mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed medium calss PVC conduit as required. 2 x 2.5 sq.mm +1 x 2.5 sq.mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed medium calss PVC conduit as required. 2 x 4 sq.mm +1x4 sq.mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed medium calss PVC conduit as required.. 2 x 6 sq.mm +1x6 sq.mm earth wire.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed medium calss PVC conduit as required.. 2 x 16 sq.mm +1x6 sq.mm earth wire
Supplying and fixing following size/moduler,GI box alongwith modular base & cover plate for modular switches in recess etc. as required 3 modules (100MM X 75 MM)
Supplying and fixing following size/moduler,GI box alongwith modular base & cover plate for modular switches in recess etc. as required 6 modules ( 200MM X 75 MM)
Supplying and fixing following size/moduler,GI box alongwith modular base & cover plate for modular switches in recess etc. as required 8 modules (125 MM X 75 MM)
Supplying and fixing following size/moduler,GI box alongwith modular base & cover plate for modular switches in recess etc. as required 12 modules ( 200MM X 150 MM)
Supplying and fixing following moduler switch/socket in the existing modular plate and switch box including connection but excluding modular plate 5/6 AMP Switch
Supplying and fixing following moduler switch/socket in the existing modular plate and switch box including connection but excluding modular plate 3 pin 5/6 Amp socket
Supplying and fixing following moduler switch/socket in the existing modular plate and switch box including connection but excluding modular plate 15 / 16 Amp switch
Supplying and fixing following moduler switch/socket in the existing modular plate and switch box including connection but excluding modular plate 6 pin 15 / 16 A Socket
Telephone Socket
Supply and fixing two modules stepup type electronic fan regulator on the existing modular plate switch box including connection but excluding modular plate as required.
Supply and fixing following size /module blank plate on the existing modular plate and switch box as required
Supplying and fixing following way single pole and neutal sheet MCB Distribution board 240 volt S.P.N Box double door 16 way Double Door
Supplying and fixing 5Amp to 32 Amp 240/415 volt 10 KA Curve MCB Single pole MCB 5 Amp to 32 AMP
Supplying and fixing following rating double pole 240 volt isolator in the existing MCB DB complete with connection testing and commissioning 63 Amp S.P.N
Providing laying testing and commissioning of chemical earthing maintenance free excavation of earth and back filling of good earth for installation od 3mtr long 4.2 mm dia stainless steel copper electode with chemical compound as required
Supply and fixing of G.I strip 25 mm x 3mm for earthing
Supplying and fixing PVC Batten Holder modular type complete job
Supplying and fixing Fan sheet complete job
Supplying and fixing Round Sheet complete job
Joint sheet of sorts
Industrial socket with MCB 40Amp
PVC Tape
VIKAS MAHAJAN
GLOBAL ENGINEERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .