| Sl No | Description | Qty | Unit | SREE RAGAVENDRA INDUSTRIAL ENGINEERS L1 |
|---|---|---|---|---|
| 1.00 | Supply, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s), minimum two compressors (with individual seperate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condensor fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 Degree Celcius. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity <40 kWr ISEER 5.4, Capacity > 40 and <70 ISEER 5.5, Capacity > 70 ISEER 5.6 for ECSBC Building) | 16 | Nos. | 4,42,843 ₹70,85,488 Lowest |
| 2.00 | Supply, Installation, Testing and Commissioning of 8TR capacity and external static pressure VRF/VRV ceiling mounted mid high static ductable type Indoor unit equipped with washable synthetic media prefilter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration Isolators, drain pan, drain pump, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Signals. The system shall be capable to adjust air flow as per room requirement automatically. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor) High Static Ductable units (minimum 49 to 77 Pascal external static pressure) | 32 | Nos. | 1,15,307 ₹36,89,824 Lowest |
| 3.00 | Supply, Fabrication, installation and testing of 1.0mm thickness galvanised sheet steel metal ducts (FACTORY FABRICATED DUCTS) in accordance with the approved shop drawings complete with all accessories like vanes, flanges, suspension rods , anchor bolts, GI bolts & nuts, canvas connections , duct dampers & splitter dampers etc.,and as required | 3,000 | Sq.Meter | 2,031 ₹60,93,000 Lowest |
| 4.00 | Supply and Installation of 1 ½ inch PVC Drain pipe with necessary accessories
including Insulation for connection to indoor unit and its connecting to common drain point. | 650 | Meter | 314 ₹2,04,100 Lowest |
| 5.00 | Supply, Installation, testing and commissioning including vaccumization and Nitrogen testing of 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required | 200 | Meter | 700 ₹1,40,000 Lowest |
| 6.00 | Supply, Installation, testing and commissioning including vaccumization and Nitrogen testing of 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required | 200 | Meter | 1,467 ₹2,93,400 Lowest |
| 7.00 | Supply, Installation, testing and commissioning including vaccumization and Nitrogen testing of 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required | 1,100 | Meter | 1,286 ₹14,14,600 Lowest |
| 8.00 | Supply, Installation, testing and commissioning including vaccumization and Nitrogen testing of 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required | 1,100 | Meter | 2,231 ₹24,54,100 Lowest |
| 9.00 | Supply,installation of GI Trunking Tray constructed from 16G GSS, MS L angle support for Tray, covered with 16G GI sheet cover for all exposed copper refrigerant pipes. | 1,500 | Sq.Meter | 1,516 ₹22,74,000 Lowest |
| 10.00 | Supply, Installation, Testing and Commissioning of Y/T/Multi Joints in indoor units. Joints shall be of same Original Equipment Manufacturer (OEM) make as of ODUs and IDUs | 64 | nos. | 5,723 ₹3,66,272 Lowest |
Tender Value
₹1.9 Cr
EMD Value
₹3.8 L
Closing Date
20 Jun 2026, 5:00 pmClosed
Senior Manager(CMM-Works Group)
Kudankulam
Works contract for supply, installation, testing and commissioning of 256 ton capacity VRF/VRV chilled air system in documentation center for KKNPP-1 to 6.
2026_NPCIL_277826_1
NPCIL/KK-1 6/E-US/ELECTRICAL INFRA/PT/2026/54
Open Tender
Electrical Works
Works
180 days
KKNPP
Pre Qualification Details Available in tender document
3 documents required · 3 mandatory
₹0
₹3.8 L
CMM Works Group Conference Hall
9 Sept 2026
19 May 2026
22 Jun 2026
19 May 2026
20 Jun 2026
29 May 2026
19 May 2026 - 25 May 2026
26 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s), minimum two compressors (with individual seperate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condensor fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 Degree Celcius. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity <40 kWr ISEER 5.4, Capacity > 40 and <70 ISEER 5.5, Capacity > 70 ISEER 5.6 for ECSBC Building) | 16 | Nos. | - | - |
| 2 | Supply, Installation, Testing and Commissioning of 8TR capacity and external static pressure VRF/VRV ceiling mounted mid high static ductable type Indoor unit equipped with washable synthetic media prefilter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration Isolators, drain pan, drain pump, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Signals. The system shall be capable to adjust air flow as per room requirement automatically. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor) High Static Ductable units (minimum 49 to 77 Pascal external static pressure) | 32 | Nos. | - | - |
| 3 | Supply, Fabrication, installation and testing of 1.0mm thickness galvanised sheet steel metal ducts (FACTORY FABRICATED DUCTS) in accordance with the approved shop drawings complete with all accessories like vanes, flanges, suspension rods , anchor bolts, GI bolts & nuts, canvas connections , duct dampers & splitter dampers etc.,and as required | 3,000 | Sq.Meter | - | - |
| 4 | Supply and Installation of 1 ½ inch PVC Drain pipe with necessary accessories
including Insulation for connection to indoor unit and its connecting to common drain point. | 650 | Meter | - | - |
| 5 | Supply, Installation, testing and commissioning including vaccumization and Nitrogen testing of 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required | 200 | Meter | - | - |
| 6 | Supply, Installation, testing and commissioning including vaccumization and Nitrogen testing of 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required | 200 | Meter | - | - |
| 7 | Supply, Installation, testing and commissioning including vaccumization and Nitrogen testing of 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required | 1,100 | Meter | - | - |
| 8 | Supply, Installation, testing and commissioning including vaccumization and Nitrogen testing of 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required | 1,100 | Meter | - | - |
| 9 | Supply,installation of GI Trunking Tray constructed from 16G GSS, MS L angle support for Tray, covered with 16G GI sheet cover for all exposed copper refrigerant pipes. | 1,500 | Sq.Meter | - | - |
| 10 | Supply, Installation, Testing and Commissioning of Y/T/Multi Joints in indoor units. Joints shall be of same Original Equipment Manufacturer (OEM) make as of ODUs and IDUs | 64 | nos. | - | - |
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.54 MB
Tender.pdf
Tender Documents • 7.59 MB
Technical_Bid_54.xls
Other Document • 0.16 MB
BOQ_324467.xls
BOQ • 0.29 MB
Corri.pdf
PDF • 2.07 MB
Corrigendum54.pdf
PDF • 0.11 MB
Corrigendum54.pdf
PDF • 0.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .