Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.0 LAccepted-AOC 86 CHAK16 QAZIPURA TANDA RAMPUR UTTAR PRADESH 244925 | RAMPUR | UTTAR PRADESH | 244925 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹40.0 L+₹38,444.75 (0.97%)Rejected-Finance | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹44.3 L+₹4.7 L (11.8%)Rejected-Finance A 303 SHREE KRISHNA COMPLEX CO OP HSG SOC LTD WESTERN EXPRESS HIGHWAY OPP NATIONAL PARK BORIVALI E MUMBAI 400066 | MUMBAI SUBURBAN | MAHARASHTRA | 400066 | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹44.9 L+₹5.3 L (13.3%)Rejected-Finance 46 HUSENI LAKDA BAZAAR 242 BELLASIS ROAD MUMBAI 400008 | MUMBAI | MAHARASHTRA | 400008 | L4 | Rejected-Finance Being not lowest | |
| 5 | L5₹48.2 L+₹8.6 L (21.7%)Rejected-Finance B 13 ROOM NO 2 2 SHIVA PALM BEACH SOCIETY SECTOR4 NERUL WEST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L5 | Rejected-Finance Being not lowest |
| Sl No | Description | Qty | Unit | Anil Industrial Corporation L5 | Nilesh Construction L3 | Unitech Enterprises L4 | N F ENTERPRISES L1 | RUPESH CONSTRUCTION CO L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling mangalore patteren or similar tiles in roofing including portions bedded in cement mortar, complete all as specified and directed. | 450 | Sqm | 22 ₹9,900 | 11 ₹4,950 | 15 ₹6,750 | 50 ₹22,500 | 10 ₹4,500 Lowest |
| 2.00 | Dismantling roof battens of any description and in any position, complete all as specified and directed. | 450 | Sqm | 22 ₹9,900 | 20 ₹9,000 | 18 ₹8,100 | 10 ₹4,500 Lowest | 10 ₹4,500 Lowest |
| 3.00 | Dismantling of timber scantling in fillets, rails, posts, rafters, purlins, etc. under 40 sqcm section in any position, complete all as specified and directed. | 300 | RM | 22 ₹6,600 | 13 ₹3,900 | 15 ₹4,500 | 100 ₹30,000 | 10 ₹3,000 Lowest |
| 4.00 | Dismantling of timber scantling 40 sqcm and over in section in any position unframed work, complete all as specified and directed. | 6 | Cum | 1,111 ₹6,666 | 120 ₹720 | 350 ₹2,100 | 100 ₹600 Lowest | 500 ₹3,000 |
| 5.00 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engr-in-Charge. | 450 | Sqm | 589 ₹2,65,050 | 626 ₹2,81,700 | 660 ₹2,97,000 | 580 ₹2,61,000 Lowest | 600 ₹2,70,000 |
| 6.00 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, eaves, etc. fixed with self tapping screws, complete all as specified and directed by Engr-in-Charge. | 45 | Sqm | 567 ₹25,515 | 599 ₹26,955 | 650 ₹29,250 | 600 ₹27,000 | 550 ₹24,750 Lowest |
| 7.00 | S&F joist, channel, angle or tee section fixed indpendently, without connecting plates confirming to Fe 410-W (Gde- E-250) quality- A including welding, nuts and bolts, complete all as specified and directed. | 4,500 | Kg | 99 ₹4,45,500 | 97 ₹4,36,500 | 92 ₹4,14,000 | 88 ₹3,96,000 Lowest | 90 ₹4,05,000 |
| 8.00 | M&L Hard drawn steel wire fabric cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm dia supplied and fixed in reinforcement but not exc 4 kg per sqm for fixing and for bracing or otherwise holding firmly in position so that the placing and ramming of concrete will not displace it. The rates includes for straightening, raking or circular cutting and waste. Rates also include for straightening where reinforcement is supplied in rolls/coil, complete all as specified and directed. | 100 | Kg | 88 ₹8,800 | 116 ₹11,600 | 100 ₹10,000 | 85 ₹8,500 | 70 ₹7,000 Lowest |
| 9.00 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. | 9.85 | Qtl | 123 ₹1,211.55 | 110 ₹1,083.5 | 250 ₹2,462.5 | 10 ₹98.5 Lowest | 100 ₹985 |
| 10.00 | Supplied and fixing of framed work such as grills, gratings etc with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, windows, balcony in ground floor, framed balusters, walk ways, railings, framework of watertanks and similar work conforming to FE 290 Gde -E-165, complete all as specified and directed. | 985.2 | Kg | 99 ₹97,534.8 | 98 ₹96,549.6 | 95 ₹93,594 | 88 ₹86,697.6 Lowest | 90 ₹88,668 |
Tender Value
₹48.5 L
EMD Value
₹97,080
Closing Date
21 Jul 2025, 6:00 pmClosed
Kameshwar Prasad, IDSE, EE
GE(West), Colaba, Mumbai - 400 005
Special repairs to structural member, joinery, flooring and other B/R and E/M work of bldg No 11A, 12, 12A and garages of Bldg No 11, 12, 13H under GE (West) Colaba, Mumbai
2025_MES_716202_1
8985/E5
Open Tender
Civil Works
Item Rate
180 days
GE(West), Colaba
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (W) Colaba, Mumbai
₹97,080
Yes
5 Sept 2025
23 Jun 2025
23 Jul 2025
23 Jun 2025
21 Jul 2025
7 Jul 2025
Amount
Dismantling mangalore patteren or similar tiles in roofing including portions bedded in cement mortar, complete all as specified and directed.
Dismantling roof battens of any description and in any position, complete all as specified and directed.
Dismantling of timber scantling in fillets, rails, posts, rafters, purlins, etc. under 40 sqcm section in any position, complete all as specified and directed.
Dismantling of timber scantling 40 sqcm and over in section in any position unframed work, complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engr-in-Charge.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, eaves, etc. fixed with self tapping screws, complete all as specified and directed by Engr-in-Charge.
S&F joist, channel, angle or tee section fixed indpendently, without connecting plates confirming to Fe 410-W (Gde- E-250) quality- A including welding, nuts and bolts, complete all as specified and directed.
M&L Hard drawn steel wire fabric cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm dia supplied and fixed in reinforcement but not exc 4 kg per sqm for fixing and for bracing or otherwise holding firmly in position so that the placing and ramming of concrete will not displace it. The rates includes for straightening, raking or circular cutting and waste. Rates also include for straightening where reinforcement is supplied in rolls/coil, complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed.
Supplied and fixing of framed work such as grills, gratings etc with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, windows, balcony in ground floor, framed balusters, walk ways, railings, framework of watertanks and similar work conforming to FE 290 Gde -E-165, complete all as specified and directed.
M&L Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height, complete all as specified and directed.
M&L Mild steel TMT bars 6mm to 8mm dia and over in stirrups, spaces and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
Providing and fixing special water tight centering and shuttering including bolting, strutting, propping etc. so as to withstand a pressure of 0.1 Mpa including removal of form from all locations including beams, columns, slabs, walls, foundations, footings, landings, stairs, balconies etc., complete all as specified and as directed.
M & L for RCC 1:2:4 type B-1, (20mm graded aggregate ) grade work as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies,canopies, deck slabs and inshelves and the like, complete all as specified and directed.
Demolition of reinforced cement concrete not exc 15 cm thickness in above floors, removing debris from outside MoD land, complete all as specified and directed.
Material and labour in repair to replace old decayed timber (including piecing, scarifying, etc of old and new timber if required) second class hard wood clean sawn in scantlings timber framed and fixed in any position and description including scafoldings of any hieght, complete all as specified and directed.
Demolition of cement concrete in ground floor n.exc 15cm thickness (below or above ground level) and removing the demolished material and debris out side MoD land, complete all as specified and directed.
M&L 75mm PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in plinth protection, flooring/subbase including necessary shuttering, complete all as specified and directed.
Rebuilding the section of damaged RCC elements to its original size or as per consultants recommandations in thicknesses of 40-100 mm by providing and casting with microconcrete of grade M-40 and above including providing and fixing of watertight foam faced finish shuttering of minimun 18 mm thick. with supporting framework,all lead lift, mixing, placing, deshuttering, levelling the surface by grinding off cementitious slurry or construction joint differences if any to satisfaction of engg. incharge, curing etc. complete.(Rate including- cube test to be conducted for every 5 M.T. workdone.6 no's of sample required per test). Ensure the quality of water by testing water as per IS 456 and document the same. Ensure temperature at time of mixing should be between 25 to 40 degree celcius by electronic temperature gauge, complete all as specified and directed.
M & L for old loose spalled concrete should be chiseled from roof ceiling with the help of scrapers chisele & hammer after that cleaning of rust from mild steel rod applying cement slurry spray 3.00 kg per sqm by paint brush over cleaned surface for 8-10mm Thick ready mix plaster in for ceiling on brick wall or concrete surfaces including making groove of appropriate size and finished even & smooth witjhout using extra cement including two coats OBD over one coat interior primer coat, complete all as specified and directed.
M & L for filling cracks by cutting 'V' groove cracks of internal or external plaster of walls, ceilings/chajjas all along the crack upto 10 mm and remove the loose plaster/concrete by suitable tools, filling cracks with crack paste compound and apply the second coat after 10-12 hrs of application of first coat and for external application must be coated with paint including necessary scafolding of any hieght, complete all as specifed and direcetd.
M&L for cleaning all loose laitance on the wall and concrete substrate and applying one coat of epoxy bonding agent of SBR latex on exposed concrete surface to ensure bond between old concrete & new concrete by brush application including scafolding at any height, complete all as specified and directed.
M&L for Plastering 20mm thick avg Polymer modified mortar (ready mix pack) in two coat 15mm base coat and 5mm finishing coat with and including curing as per manufacturer's instruction, complete all as specified and as directed.
Clean existing reinforcement with wire brush/ rotary wire brush to make surface free from rust scales, loose material, dirt etc. complete and providing, applying two coats of alkaline rust converting primer confirming to ASTMB- 117, on the existing rebars and allowing it to react with rust for 6 hrs and form a corrosion resistant, insoluble and adherent protective layer, including cleaning the reinforcement, wirebrushing to remove loose rust spalls, with time interval of 1hour between the coats, complete all as specified and as directed.
Providing and application full and unbroken coating of anticorrosive protective zinc rich epoxy coating on expose reinforcement in two coats with time interval of minimum 1 hours between each coat including mixing of both componants by weight as per mfg specifications, brush application, curing to form a anticorrosive protective coating with high mechanical strength to cementitious repair works, etc, complete all as specified and directed.
Supply only integral waterproofing compound, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
M&L for HD Polished digital coloured ceramic tiles 9 mm thick (Square/rectangular) area of each tile exc 0.36 sqm but not exceeding 0.72 sqm in floors etc. set and jointed in neat cement slurry laid over 15 mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
M&L HD Polished digital coloured ceramic tiles 9 mm thick (Square/ rectangular) area of each tile exc 0.36 sqm but not exc 0.72 sqm in dado, skriting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of the tiles laid over 10 mm thick CM 1:4 (backing coat), complete all as specified and directed.
M&L Anti skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.06 sqm but not exc 0.11sqm in floors etc. set and jointed in neat cement slurry laid over 15 mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
M&L for Glazed coloured rectified digital polished ceramic tiles 600x300x8 mm thick in vertical surfaces (including designed borders) such as skirting and dados, set and jointed in neat cement slurry and pointed in coloured cement to match the shades of the tiles laid over rendering 10 mm thick in CM 1:4, complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, & brushing neat cement slurry with 3kg of cement per sqm etc., complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25 mm thick over cement screed bese laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to mirror finish inluding Screed bed or bedding layer of mortar 15 mm thick in (1:6) for laying floor finishes, complete all as specified and directed.
Ditto all as per above Item No 33 above but in riser of steps, skirting, dado and pillar laid over cement screed and jointed over rendering 10 mm thick on fair faces of brick work in CM (1:4), complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons, dados etc laid, bedded and pointed in any mortar and removal of rubbish off the site, complete all as specified and directed.
Material and labour Granite (of any type and colur) 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing laid in floors/Jambs/WHB conters and all other similar works in approved design over 20mm thick screed bed in cement mortar 1:4, complete all as specified and directed.
Dismantling of ceiling board (Plup insulation or insulation etc) or insulation board any thickness including cover fillet and grid frame work, complete all as specified and directed.
M&L for GI powder coated frame work for seamless ceiling 600x600mm grid size comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15mm each and web of 45 mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55 mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre, complete all as specified and directed.
M&L for 6mm thick exposed metal frame ceiling with calcium silicate board of siliceous and calcareous materials reinforced with cellulose fibre for fixing in 600 X 600 mm grids, complete all as specified and directed. Note:- Frame work for ceiling shall be measured and paid separately.)
S&F in repair POP false ceiling consisting of frame work made with 50 mm Sq MS tube of 18 G thickness as main runner at 600 mm c/c both ways suspended/supported with MS flats 25x4 from existing RCC slab including providing and fixing expended metal of size 5.25 mm x 1.25 mm thickness welded to main runners and applying POP (calcium silicate semihydrate variety) to the expended metal of thickness not less than 10 mm finished smooth to line and level including necessary supports scaffolding etc as required and also including applying a coat of red oxide zinc chrome primer over the MS frame work and two coat OBD apply on celling and suspended portion, complete all as specified and directed
Extra over above items no. 40 for any sunk or raised moulding, complete all as specified and directed.
M&L in repairs for 8/10 mm thick PVC ceiling or wall panelling (any colour) with aluminium frame work for receiving ceiling board / wall panelling including all necessary accessories for fixing at various levels, complete all as specified and directed.
S & F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening all complete as per requirement and direction of Engineer-In-Charge.
Providing and fixing Powder coated aluminium (minimum thickness of powdercoating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making, provision for fixing of fittings whereverrequired including the cost of EPDM rubber/ neoprene gasket required with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-In-Charge. Note : (i) Glass panes will be measured & paid separately. (ii)The quoted rate shall be inclusive of cost of rubber beading and glazing clips,hionges,handle. However it will be not be weighed and not paid separately. (iii) All other minor details including cost of locking arrangement shall be included in the quoted rate.
Taking down cement plaster of any description from brick wall surfaces etc including racking out joints and hacking for key, scrubbing down with water etc, complete all as specified and directed.
Material and labour for 15 mm thick cement plaster in CM (1:6) on brick work/ RCC wall and finish the surface fair and even without using extra cement, complete all as specified and directed.
M&L Rendering 15mm thick in cement mortar 1:4 using intergral water proofing compound on fair faces of brick work to be finished even and smooth with out using extra cement, complete all as specified and directed. Note: Integral liquid water proofing compound to be used in per bag of cement shall be as per manufacturers instructions and paid separately under respective items.
Material & Labour for two coats of oil bound distamper over 1 mm thick wall care putty on new plastered surfaces including preparation of surface, complete all as specified and directed.
Material & Labour for two coats of oil bound distamper over 1 mm thick wall care putty on old plastered surfaces including preparation of surface, complete all as specified and directed.
Providing & applying anti algal water-based Elastomeric exterior wall finish on newly plastered surfaces including surface preparation, applying suitable wall Prime seal primer 8-10 Sqm per ltr coverage area and application of two coats (base coat 4.2 -4.7 & top coat 6-6.5 sqm per ltr coverage area) & of paint by roller etc, complete all as specified and directed. Note : Height of Bldg up to fourth floor.
Providing & applying anti algal water-based Elastomeric exterior wall finish on old plastered surfaces including surface preparation, applying suitable wall Prime seal primer 8-10 Sqm per ltr coverage area and application of two coats (base coat 4.2 -4.7 & top coat 6-6.5 sqm per ltr coverage area ) & of paint by roller etc. , complete all as specified and directed. Note : Height of Bldg Up to fourth floor.
Material and labour for preparation of new surface painted wood or wood based surfaces, of any description, not otherwise described over 10cm width or girth and apply two coats of synthetic enamel paint over one coat of primer, complete all as specified and directed.
Material and labour for preparation of old painted wood or wood based surfaces, of any description, not otherwise described over 10 cm width or girth and apply one coat of synthetic enamel paint, complete all as specified and directed.
M&L for two coats of synthetic enamel painting on new steel surfaces including preparation of surface and one coat of red oxide zinc chrom primer on surfaces of any description over 10cm in width or girth, not otherwise described, complete all as specified and directed.
M&L for two coats of synthetic enamel painting over a coat of red oxide primer including preperation of steel surface of any description n.exc 10 cm width or girth, complete all as specified and directed.
M&L for one coat of synthetic enamel painting on old steel surfaces including preparation of surface of any description, over 10cm in width or girth, not otherwise described, complete all as specified and directed.
Taking down Chowkhats and shutters of windows/ventilators with wire mesh / glass and MS grills of any size including all fittings and fixtures, complete all as specified and directed.
Taking down chowkhats or frames exc 1.50 sqm but n exc 4 sqm each with shutters (without taking off shutters from the frame), complete all as specified and directed.
Taking down chowkhat with shutter not exc 1.50 sqm each (without taking off shutters from the frames), complete all as specified and directed
Supply & fix for 2nd class hard wood plain solid straight chowkhat and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joint, complete all as specified and directed.
Supply & fix 35 mm thick 2nd hard wood rail and style plain framed panelled shutters(any panel) with lock rail and panel of 9mm thick B.W.P commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS 1003 (Part-I) kiln seasoned and chemically pressure treated, complete all as specified and directed.
Supplied and fix to shutter of 2nd class hard wood 35mm thick Glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc(without sash bars) edges of framing plain, chamfered or rounded, fittted with cut and mitred beads for securing gauge,etc sizes of member of shutter as specified SSR part-I Section 8 clause 8.24 (a), complete all as specified and directed.
Supply & fix 35mm thick flush shutter, solid core construction, with block board core and plywood face panel, commercial type on both sides, complete all as specified and directed.
S&F factory made single extruded WPC (Wood Polymer Composite) solid door Frames/Chowkhat comprising of 62mm X32mm size applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold unserviceable fast/lugs/SS dash fasteners of required dia and length all as specified and as directed by Engr-in-Charge.
Supplying and fixing factory made single extruded WPC (Wood Polymer Composite) solid door Frames/Chowkhat comprising of 100 MM X 50 MM size applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length all as specified and as directed by Engr-In-Charge.
Supplying and fixing factory made single extruded WPC (Wood Polymer Composite) solid door Frames/Chowkhat comprising of 125 MM X 65 MM size applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length, complete all as specified and directed.
S & F factory made 28-30 mm thick single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size, modulus of elasticity 850 N/mm” and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and as directed by Engr-in-Charge.
S & F Sheet glass ordinary 5.5 mm thick not exc 0.50 Sqm in each panes and glazing with oil putty etc, complete all as specified and directed.
S & F in repairs sheet glass ordinary 3 mm thick not exc 0.50 Sqm in each panes and glazing with oil putty, wooden beads, etc, complete all as specified and directed.
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed.
S&F in repairs stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed.
S&F in floor door stopper of aluminium alloy body and tongue, length of leg 140 mm, anodised, with hard drawn steel spring and fubber foot , fixed, complete all as specified and directed.
S&F Extruded aluminium alloy handles (ISI marked) 150 mm, fabricated type, anodized, complete all as specified and directed.
S&F Extruded aluminium alloy barrel tower bolts (ISI marked), with bright bolt and fixed of size 200 mm for doors, complete all as specified and directed.
S&F Aluminium anodised, barrel tower bolts (ISI marked) of extruded section and fixed of 150 mm size, complete all as specified and directed.
S&F Butt hinges (ISI marked) of size 100 mm, medium weight, stainless steel min 3 mm thick for doors, complete of design all as directed by Engr-in-Charge.
S&F in repairs Stainless Steel drapery road (1 mm thick stainless steel section outer dia 25 mm with bracket, ring & fancy side holders, complete all as directed by Engr-in-Charge.
Demolition of brick masonary built in cement mortar all as specified.
M & L Brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in cm (1:6), complete all as specified and directed.
Taking up or down 15mm dia steel tubing and connections, including cleaning for refixing or removal to store, complete all as specified and directed.
S&F 15mm dia tubes, 'medium grade' galvanised, with all fitting and fixed complete incl cutting chasing pinning and making good to walls and ceilings or laid in floors, complete all as specified and directed.
Refixing old 15mm dia steel tubing and connections in new or old position (Walls, ceiling, floors, etc.), complete all as specified and directed.
Taking up or down 20mm dia steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed, complete all as specified and directed.
S&F 20mm dia tubes, 'medium grade' galvanised, with all fitting and fixed complete incl cutting chasing pinning and making good to walls and ceilings or laid in floors, complete all as specified and directed.
Refixing old 20mm dia steel tubing and connections in new or old position (Walls, ceiling, floors, etc.), complete all as specified and directed.
Supply and fixing in repairs 500 ltr rotational moulded PVC tank 3 layer in position at any location on top of the building including removing existing tank disconnecting all incoming and out going connections, provision of new fittings including with float valve suitable up to 20mm bore GI pipe all as per existing requirements, including taking down old tank any type, complete all as specified and directed.
Taking down rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., removal to Store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and directed.
S&F PVC (SWR), 110mm bore, single socketed in any length with rubber ring joints, fixed to walls with MS clamps made out of flat iron of size 25mm x 3mm including nuts bolts etc, complete all as specified and directed.
S&F 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls etc with MS clamps made out of flat iron of size 25mm x 3mm including nuts bolts etc, complete all as specified and directed.
S&f 110mm dia PVC (SWR) bends any radius, complete all as specified and directed.
S&F 75 mm dia PVC (SWR) bends any radius, complete all as specified and directed.
S&F 110 mm PVC (SWR) junction single, (Single T) equal or unequal, complete all as specified and directed.
S&F 75 mm PVC (SWR) junction single, (Single T) equal or unequal, complete all as specified and directed.
S&F 110 mm PVC (SWR) junction single, (Single Y) equal or unequal, complete all as specified and directed.
S&F 75 mm PVC (SWR) junction single, (Single Y) equal or unequal, complete all as specified and directed.
M&L PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement, complete all as specified and directed.
S&F in PVC (SWR) floor trap 75 mm, plain with CP grating including joining and solvent cement, complete all as specified and directed.
S&F in repairs tubular towel rail brass chromium plated , 20mm dia, 60cm long between flanges, complete all as specified and directed.
Material & Labour in repair for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangemet for Stainless Steel grade 304 decorative designer railings, staircase, covers, sitting place, shed etc. (design and pattern as approved) made out, complete all as directed by Engineer-in-Charge.
S & F 12 mm thk toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required, complete all as specified and directed.
Supply and fixing Sun control film, 50 micron non reflective type, sticked to glass as per manufacturers instructions, complete all as specified and directed.
S&F in repair SS 202 Stain finish Handle D type, 25mm dia 600mm long for glass shutter, complete all as specified and directed.
S&F in repair bottom/top patch fitting for pivot, complete all as specified and directed.
S&F in repair bottom lock patch fitting, complete all as specified and directed.
S&F Aluminium (Die cast) body, door closer, hydraulically regulated, designation No. 3, unversal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 kg, complete all as specifed and directed.
S & F in repairs of SS 304 Grade metal letters of height 200mm with PU paint to match the logo colors, mirror polish finish, anti rust and including necesssary arrangements to fixing in walls, using scaffolding at any height, complete all as specified and directed.
S & F in repair of 3 mm thick panel of any type, pattern and shape Aluminium Composite Panel (ACP), aluminium thickness of 0.5mm, Front side finish of aluminum roll coated with Plain / coloured / wooden texture PE / PVDF, Core material of Non-toxic polyethylene, Macromolecular lamination film, Rear side of Aluminum coated with primer and including frame work using of Fasteners, including concealed screws, nuts, bolts and other items required for connecting aluminium to aluminium / steel / wooden / ply board, Blind rivets all fixing anchors, brackets and similar attachments used in the erections, shall be of aluminium, non-magnetic stainless steel, zinc coated steel, for fixing in both internal / external wall cladding complete weather proofing sealant of a polyurethane elastic joint / structural silicone sealant / pre-formed gaskets to the Horizontal & Vertical Joints in the Aluminium cladding / facade as per manufacturer's instructions complete all as specified and directed. Note : 1. The unit rate quoted is deemed to be inclusive of all necessary fixing acceserries mentioned in the description of work and scaffolding works at any height for installation. 2. For payment purpose panels areas will be measured on one side only.
M&L for two coats of smooth interior acrylic emulsion with texture finish having VOC less than 50 grams per ltr complying LEEDS criteria @1 ltrs(unndiluted) /10 sq mtrs diluted with water in 2:1 ratio applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI.Allow 6-8 hrs to dry the surface in both the coats of paint as per manufacturer instructions, complete all as specified and directed.
S&F in repairs 15 mm dia brass CP fancy wall mixer with L Bend (incl provision of O/H shower & hand shower) for mixing hot and cold water screwed down for iron pipe, complete all as specified and directed.
S&F in repairs 15 mm dia brass CP centre hole basin mixer for mixing hot and cold water screwed down for iron pipe, complete all as specified and directed.
S&F in repairs 15 mm bore gun metal gate valve cast copper alloy, screwed down high pressure with wheel head, screwed both ends with crutch or butterfly handle for iron pipes, complete all as specified and directed.
S&F in repairs Vitreous China Wash hand basin, white, oval shape, size 580 mm x 450 mm size, SLS-WHT-0611F, excluding taps, chain & plug & porcelain stopper but incl brackets, 40/32 mm dia PVC waste pipe, PVC connection, chromium plate coupling 32 mm dia, approved pedestal SLS-WHT-1510 & cutting for and pinning ends of brackets or erecting stand, complete all as specified and directed.
S&F two piece EWC water closet Single Piece EWC 655x345x750 mm including Cistern, PP Soft close seat cover and hinge, fitting accesorries, Accesories set and cistern fittings, fixed with waste coupling and waste pipe, complete all as specified and directed.
S&F in repairs Vitreous China half stall urinals, white complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, magnum urinal spreader, pointing around urinal back in cement; flush pipe, grating and union for discharge pipe, complete all as specified and directed.
S&F 50mm dia low density polyethylene (LDPE) pipes of pressure rating 6 kgf/sqcm fixed complete to walls, ceiling or in floors etc including cutting, chasing, pinning and making floor good with existing one, complete all as specified and directed.
S&F in repairs PVC valve less syphonic action type flushing cistern low level white, dual flush, ISI marked (IS:7231) with PVC inlet ball valve, float and handle, 10 ltrs capacity and connection to pipes including PVC connection and 32mm dia PVC long bend for squat pattern etc, set with concrete and making good to floor including taking down existing, complete all as specified and directed.
S&F in repairs Soap dish approximate size 160x 160x90mm, complete all as specified & directed.
S&F in repair 15mm bore, chromium plated bib taps cast copper alloy with crutch or butterfly handle screwed down for iron pipe, complete all as specified and directed.
S&F in repairs fancy type chromium plated 15mm bore stop valve/angle cock cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and directed.
S&F in repair Brass chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union alongwith arm 225mm and flange, complete all as specified and directed.
Taking down carefully copper/aluminum point wiring light/fan/sockets out let/power point complete (fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc. are to be measured separately) and/or drawing out from existing conduit/batten and making good disturbed surface of walls/floors/ceiling, complete all as specified and directed.
Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated, unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, concealed on wall/ceiling with accessories and incuding provision of 1.50 Sqmm single core PVC insulated, unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box/metal flush box with suitable modular or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139 (pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new 3 mm thick plastic laminated sheet top cover for housing the switches, socket outlets, fan regulators etc. with brass screws and brass washers and making good the disturbed surfaces as per existing for one light fan point controlled by one switch. Note :- Switch, socket and fan regulators to be measured and paid for separately.
Description all as per Srl item No.123 here in before but for socket outlet point 5 Amp on same board.
Description all as per Srl item No. 123 here in before but for socket outlet point 5 Amp on Independent board.
Description all as per serial item No. 123 above but with 4 sqmm cable for 3 pin 15 Amps switch socket outlet (Power point).
S&F Modular switch 1 way 6 A module 230/250 volt, AC supply, ISI Marked, with white cover plate with frame, complete all as specified and directed.
S&F Modular switch 1 way 16 A module 230/250 volt, AC supply, ISI Marked, with white cover plate with frame, complete all as specified and directed.
S&F Modular sockets 6A 2/3 pin combined 2 module 230/250 Volts, 50 Hz, AC supply, ISI Marked, with cover plate, complete all as specified and directed.
S&F modular sockets 6A/16A, 2/3 pin combined 2 module 230/250 Volts, 50 Hz , AC supply, ISI Marked, with white cover plate with frame, complete all as specified and directed.
S&F in repairs Modular type AC Box, 4 Module with Socket and 25 Amp SP mini MCB in plastic box enclosure along with cover plate and top, complete all as specified and directed.
S&F Modular Fan step/ electronic regulator, 120W - 2 module A module 230/250 volt, AC supply, ISI Marked, with cover plate, complete all as specified and directed.
S&F in repairs ceiling rose surface bakelite 65x50mm, 3 terminal, complete all as specified and directed.
S & F LED light fitting 1x9W/1X10W luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
Supply and Fix 20 watt LED, 6500 K, in repair, 4 feet long fixed including on pvc square for mounting the fittings and electrically connecting with three single core 23/0.0076. PVC insulated multi strandard copper flexible cable from ceiling rose to light fitting (connector block of lamp fitting) and one for earthing, complete all as specified and directed.
S & F Exhaust fan 230 volts, 250mm, metal heavy duty with wooden frame including making all electric connection complete all as specified and as directed including cutting of hole on wall and makng good disturbed surface of wall and outer wooden box for fan fix on wall, complete all as specified and directed.
M & L refixing of ceiling fan (old fan) and servicing complete connecting up including fan provision of cable from ceiling rose or connector and fan Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. with taking down fan, sealing cable end, dismantling romoving and hanging fan and blades and making fuctionable i .e change capacitor, condenser, fan rod 3 to 5 RM of GI pipe, winding, servicing, complete all as specified and directed.
S&F Ceiling fan complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor, BLDC making all electric connection. huck and suitable size rod for hanging ceiling fan, complete all as specified and directed.
S&F Slim designed LED recessed square 2X 2, 40 watt Warm/ white type flat panel PDC aluminium housing and PMMA diffuser including taking down old unserviceable one, complete all as specified and directed.
S&F MCB Distribution board, 240 volts single pole and neutral, single door, sheet steel, enclosure, powder coated with 100 Amps rated busbar with neutral link, 8 ways, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection, including taking down, complete all as specified and directed.
S&F in repairs MCB DP, 240 Volts, 40 Amps, 10 KA rupturing capacity 'C' series, complete all as specified and directed.
S&F in repairs MCB, single pole 240 volts 6 to 32 Amps capacity fixed in DB's, complete all as specified and directed.
S&F in repairs MCCB DB TPN 4 way vertical sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, single door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting, complete all as specified and directed. Note : MCB SP/TPN shall be measured and paid seperately under appropriate items of this schedule. Note : Copper thimble shall be used for connection of cable.
S&F in repairs MCCB TPN, 240 Volts, 63 to 100 Amps, 10 KA rupturing capacity 415 Volts, complete all as specified and directed.
Material & Labour for sub main wiring, with two run of 10 sqmm stranded copper conductor PVC unseathed FRLSH wire along with 10 sqmm green colour wire as earth contuinity conductor connected to common earth dolly including PVC FR heavy duty conduite of adequate size (not less than 32 mm dia) for housing the wires for from Pannel / Main DB to house SPN DB including taking down old Unsv submain with all associated fixtures complete all as specified & as directed by Engr-In-Charge. Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. Note: Mode of measurement two runs of 10 sqmm cable and one run of 10 sqmm cable with PVC conduite shall be measured as one RM.
M & L Sub main wiring with two run single core 4 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100V including 20mm dia Cassing capping ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 4 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion inculding taking down old wiring etc, complete all as specified and directed. Note: (i) Two runs of 4 sqmm and one run of 4 sqmm cable and one run of PVC conduit shall be measured as one RM.
M & L Sub main wiring with two run single core 1.50 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100V including 20mm dia Casssing cappiing ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 1.50 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion inculding taking down old wiring etc, complete all as specified and directed. Note: (i) Two runs of 1.50 sqmm and one run of 1.50 sqmm cable and one run of PVC conduit shall be measured as one RM.
Supply and laying in trenches, floors, fix on wall/pole, passing through pipes etc., LT UG cable, 1100 volts grade, PVC/ XLPE insulated, with multistranded aluminium conductors, armoured with galvanised steel wire or tape, gland, lugs with PVC 32mm with fixing wall saddling fittings etc, of size 16 Sqmm 4core , confirming to IS specifications, complete all as specified and directed.
Supply, laying connecting and testing XLPE insulated, PVC sheathed, armoured LT electric power UG cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade, cross sectional area 6 Sqmm, 2 core laid through duct/ pipe / in trench etc with PVC 32mm with fixing wall saddling fittings etc. including excavation, Refilling, removing, sand and brick as requirement cable glands & lugs, complete all as specified and directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 60 cm X 60 cm X 6 mm buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4mm dia by means of bolts, check nuts and washers, galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:2:4) type B-1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm c/c both ways and one handle for lifting made out of 8 mm dia TMT bar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I.
RUPESH CONSTRUCTION CO (BID ID -3358635)
Nilesh Construction (BID ID -3365319)
Unitech Enterprises (BID ID -3365726)
Anil Industrial Corporation (BID ID -3350184)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .