Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
Refer Docs
Closing Date
20 Dec 2026, 5:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
BINDEY KUMAR
DIRECTOR
SHEIKHPURA PATNA
BINDEY KUMAR
DIRECTOR
Group A: Critical Care Medicine Echo Cardiography Machine Digital Portable X- Ray/ Mobile DR Electrosurgical Unit
144197
NIT No.28/2026-2027/Bio-Medical Eqpt/IGIMS/Store/A
Open Tender
GENERAL
Sheikhpura
• Status of Bidder:
? Manufacturer or Authorized Agent of the Manufacturer
? Whether Public Undertaking, Public Ltd., Private Ltd. Company or Proprietary Firm/partnership firm
(Please attach Notary certified MANUFACTURER?S AUTHORISATION FORM as per FORMAT placed at Annexure ? III)
• Power of Attorney as per Annexure - V in favour of person to sign, submit and negotiate the bid.
• Certificate towards market standing of minimum 05 years in the area of supply, installation, commissioning and maintenance of IT Equipment?s.
• Certificate for sole ownership / partnership
• Statement of financial standing from bankers
• Statements of turnover per year for last three successive years duly certified by the Chartered Accountants.
• Notary certified User List (List of Govt./Semi Govt., Reputed Pvt. Hospital) where quoted model of the items has been supplied and installed.
• Notary certified Supply order copy (Minimum 3nos. or more) issued by Govt. /Semi Govt. /Reputed Pvt. Institutions/organization for the quoted items.
• Notary certified Performance certificate of the same supplied machine (of quoted make and Model) issued by Head of the dept. or Institution after a minimum period of six months of installation
• Prerequisite (if any) for installation of the Machine, if any, to be provided by the Institute.
• Whether rates quoted are inclusive of all taxes or not.
• Whether rates are quoted as per format mentioned in the Bidding Document or not.
• Affidavit to the effect that the bidder is not blacklisted by any Govt. agency or has no pending case either Civil or Criminal against them.
• Affidavit, to the effect that the bidder is not supplying the quoted item(s) to any other Govt. /Semi Govt. Organizations / Institutions / Hospitals at the rate lower than the rate quoted against this tender.
• Bid Security amount deposited is enclosed or not. If yes, please mention the details.
• Original Technical Catalogue of the quoted model.
• Certificate, to the effect that bidder will maintain the quoted item(s) during Warranty period of three years as mentioned against each item including all spares, accessories, consumables etc., (Please mention the name of the item / items with price, which are not supplied by the bidder free of cost with frequency of replacement)
• Certificate, to the effect that bidder has quoted its rate for Comprehensive Annual Maintenance Contract inclusive of labour, spares, consumables, accessories etc. on per year basis for a further period of seven years after expiry of warranty period of three years in the price bid.
(Please mention the name of the item / items with price, which are not supplied by the bidder free of cost with frequency of replacement during Comprehensive Annual Maintenance Contract period in the price bid)
• Acceptance of all terms / conditions towards after sales / services as mentioned in the bidding document. (Clause No- 13 of ?Instruction to Bidder ?& clause no- 3, 4 and 5 of Condition of contract.)
• Compliance Statement with relation to the technical specification as mentioned in the bidding document duly supported by the original catalogue. The bidder must quote specification in the compliance column.
• Compliance Statement with relation to the terms & conditions as mentioned in the document.
• PAN and copies of Income Tax Returns for the last three years.
• Duly attested copy of GST registration certificate.
• Should have OEM authorization against this tender.
GENERAL
ITEM RATE
L1
1
21 documents required · 21 mandatory
₹2,500
Processing Fee: 1180
Conference Hall (Ground Floor, New Administrative Building), IGIMS, Patna
25 Nov 2026
25 Nov 2026
28 Dec 2026
25 Nov 2026
20 Dec 2026
25 Nov 2026
27 Nov 2026
180 days
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 28/2026-2027/Bio Medical Equipt /IGIMS/Store
A.: To be filled by the bidder and submitted along with the Technical Bid.
Sl. No. Terms & Conditions as per Bidding Document Page No. Remarks
1 Status of Bidder:
· Manufacturer or Authorized Agent of the Manufacturer
· Whether Public Undertaking, Public Ltd., Private Ltd. Company or Proprietary Firm/partnership firm
(Please attach Notary certified MANUFACTURER’S AUTHORISATION FORM as per FORMAT placed at Annexure – III)
2 Power of Attorney as per Annexure - V in favour of person to sign, submit and negotiate the bid.
3 Certificate towards market standing of minimum 05 years in the area of supply and or maintenance of bio-medical equipments.
4 Certificate for sole ownership / partnership
5 Statement of financial standing from bankers
6 Statements of turnover per year for last three successive years duly certified by the Chartered Accountants.
7 Notary certified User List (List of Govt.
/Semi Govt., Reputed Pvt. Hospital) where quoted model of the items has been supplied and installed.
8 Notary certified Supply order copy (Minimum 3nos. or more) issued by Govt./Semi Govt.//Reputed Pvt. Institutions/organization for the quoted items. ( same model)
9 Notary certified Performance certificate of the same supplied machine (of quoted make and Model) issued by Head of the deptt. or Institution after a minimum period of six months of installation
10 Prerequisite (if any) for installation of the Machine, if any, to be provided by the Institute.
11 Whether rates quoted are inclusive of all taxes or not.
12 Whether rates are quoted as per format mentioned in the Bidding Document or not.
13 Affidavit to the effect that the bidder is not
blacklisted by any Govt. agency or have no pending case either Civil or Criminal against them.
14 Affidavit, to the effect that the bidder is not supplying the quoted item(s) to any other Govt. / Pvt. Organizations / Institutions / Hospitals at the rate lower than the rate quoted against this tender.
15 Quality Assurance Certificate like ISI, ISO-9002, IP/BP, CE, FDA (US) or any other (please specify)
16 Bid Security amount deposited is enclosed or not. If yes, please mention the details.
17 Original Technical Catalogue of the quoted model
18 Certificate, to the effect that bidder will maintain the quoted item(s) during Warranty period of three years including all spares, accessories, consumables etc.,
(Please mention the name of the item / items with price, which are not supplied by the bidder free of cost with frequency of replacement)
19 Certificate, to the effect that bidder has quoted its rate for Comprehensive Annual Maintenance Contract inclusive of labour, spares, consumables, accessories etc. on per year basis for a further period of seven years after expiry of warranty period of three years in the price bid.
(Please mention the name of the item / items with price, which are not supplied by the bidder free of cost with frequency of replacement during Comprehensive Annual Maintenance Contract period in the price bid)
20 Acceptance of all terms / conditions towards after sales / services as mentioned in the bidding document.( Clause No- 13 of “ Instruction to Bidder “ & clause no- 3, 4 and 5 of Condition of contract.)
21 Compliance Statement with relation to the technical specification as mentioned in the bidding document duly supported by the original catalogue. The bidder must quote specification in the compliance column Mere writing” Complied shall not be accepted.
22 Compliance Statement with relation to the terms & conditions as mentioned in the document.
23 PAN and copies of Income Tax Returns for the last three years.
24 Duly attested copy of GST registration certificate.
B: To be filled by the Bidder and submitted along with Price Bid
Sl. No. Terms & Conditions as per Bidding Document Page No. Remarks
1 Item wise price for the item(s) as mentioned in the Bidding Document and as per format attached as Annexure – I(a) or I (b)
2 Rate for Comprehensive Annual Maintenance Contract as per terms & conditions mentioned in the Bidding Document and as per format attached as Annexure - II
Note: If the above-tender details are not mentioned and required documents are not attached at appropriate places, the offer of the bidder(s) shall be summarily rejected. Hence, bidder(s) are advised to go through the bidding document carefully and tender be prepared with all the required documents to avoid rejection of offer.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 28/2026-2027/Bio Medical Equipt /IGIMS/Store
ELIGIBILITY CRITERIA Mentioned Page no.
1 Manufacturers or their authorized dealers/Indian subsidiaries/direct importers having a place of business in any of the States of India are eligible to participate in this tender.
2 The bidder and manufacturer of the equipment offered should be in the business of the supply and installation of same / similar equipment for the last five calendar years.
3 (a) The manufacturer should have completed at least 05( Five ) nos. installations of the quoted items in Govt. /Pvt. Institutions /Hospitals in India. The installations mentioned by the manufacturer in their offer must be functional and performance certificate for the same issued by the user concerned also be attached with the offer.
(b) The bids quoted as the authorized representative of the manufacturer meeting the above criteria 02 (a) should have also supplied and installed at least 03( Three) nos. installations of the quoted items in Govt. /Pvt. Institutions/ Hospitals in India in last five years from the last date of submission of tender. The installations mentioned by the authorized representative in their offer must be functional and performance certificate for the same issued by the user concerned also be attached with the offer.
4 The Bidder should be public undertaking /Autonomous Body /Public Ltd./Pvt. Ltd. Company or proprietary firm /Partnership Firm and should be in medical equipment business since last five years in India. The Bidders having manufacturing facility in their name in India for the majority of the items offered by them shall be given preference.
5 The Bidder (manufacturer or their authorized agent) should have had average annual financial turnover of Rs. 50 Lakh during the last three years ending s 31st March 2026.
6 Bidders who have the capability to attend repairs of these equipment within the time mentioned in this bidding document and who are willing to provide stand by equipment or replace the faulty equipment if the repair/down time extends beyond 72 hours from the time of reporting of the fault within the next 48 hours (total down time should not exceed 5 days in one instance). The bidders who have the capability to ensure the uptime mentioned in this document (Documentary proof shall be submitted on the after sales facilities and expertise of the bidder.)
7 Bidders are not offering the equipment of a firm /company that has
been blacklisted by Indira Gandhi Institute of Medical Sciences – Patna or blacklisted/debarred by any other State / Central Government's organization.
Note: Notwithstanding anything stated above, the Institute reserves the right to assess the Bidder’s capability and capacity to perform the contract satisfactorily before deciding on award of contract, should circumstances warrant such an assessment in the overall interest of the purchaser.
The Institute reserves the right to ask for a free demonstration of the quoted equipment at a pre determined place acceptable to the purchaser of technical acceptability as per the tender specification, before the opening of the price tender.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 28/2026-2027/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 1180
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- Group A
1: ECHOCARDIOGRAPHY MACHINE
TECHNICAL SPECIFICATION FOR ECHOCARDIOGRAPHY
The high-end machine is defined as the one which has all the latest modalities of Cardiac Echocardiography capabilities defined by the leading International Echocardiography societies. This quoted model for the echocardiography Machine must be latest and Top End / Top of the Line for the said category / specifications.
1. A complete dedicated digital Echocardiography, Radiology unit for wide range of premium performance whole application imaging in adults & paediatrics.
2. Wheel based Mobile Trolley mounted system with user friendly Ergonomics, adjustable Height, and sideways easymanoeuvrability
3. Built in workstation / data ‘management system for digital acquisition, storage and review of complete cardiac ultrasound studies including static and dynamic clips in easymanoeuvrability DICOM format, read / write zoom.
4. Studies can be reviewed, and output should be stored to CD / DVD /USB
5. The machine must have sharp and high-quality image reproduction with heavy duty performance:
Operating Features and Characteristics
6. Display Resolution: Full High Definition 192
7. Minimum Display Size: 21” or better LCD / LED /OLED
8. Operating & Display Modes:
2D-CDI –Doppler Mode
2D Tissue /Mode
Anatomical M-Mode
Spectral Doppler
Doppler (PW &CW)
Duplex and Triplex Doppler
m) CW Doppler Steerable
PW / HPRF Doppler
Intima Media Thickness (IMT)
Tissue Harmonic imaging
Myocardial 20 – Strain Imaging / Tissue Tracking (Tissue Doppler based / Speckle Tracking based)
Stress Echo Mode (Physical and Pharmacological)
Transoesophageal Echo
Vascular Calculations /IMT
Tissue Synchronization Imaging Mode
Tissue Velocity Imaging Mode / CRT Evaluation Tool / Tissue Dop imaging mode
2D Angio Flow / Power Doppler imaging
Color Flow / Color Doppler imaging
Cardiac Measurements
Strain elastography
STIC feature should be there
Automated tool software should be there to calculate FLC.
Machine should be enabled with rendering mode for realistic volume imaging display
Multi slice imaging should be there.
Contrast imagingshould be available.
On Board Review Display Formats:
9. Live and Stored Display Format: Full size and split screen
10.Post Processing of images and Biometry of Stored images
11.Review Image Format: For still and cine, simultaneous capability B+PW, B+ CFM / COI{TVI/ TDI)+PW, CW, B+ or triplex mode, B+ color split screen display
12. 13.3” touch screen
13. Alphanumeric keyboard with built-intrackball
14. Direct access to system functions through dedicated keys
15. Indicator lights identify activated keys
16. Audio volume control with bidirectional / stereo speakers and footswitch
17. User selectable image magnification control
18. Adjustable transmit focusing control
19. Time Gain Compensation controls (6 or more)
20. Total and / or Lateral Gain Compensation controls (6 or more)
Caliper / Measurements:
21.6 to 8 calipers for measurement per screen trace length measurements for distance, angle, distance depth from skin line, area, circumferences, compound / volume, slope, time, heart rate and acceleration
22. Artificial Intelligence / Auto Measurements for 2D (Diameters, Areas and M-Mode Based / Volumatic Ejection Fraction (EF) Calculations) & 4D and Doppler Spectrum Recognition should be available.
23. 2D Cardiac, Peripheral, Paediatric, Adult Cephalic, Carotids, Peripheral Venous, Vascular, and Transoesophageal with all required software for measurements
Machine to be quoted with maximum available frame rate
24. 2000 f / sec or more in B-Mode and / or 400 f / sec in Doppler mode
25. Minimum Cine Memory for 2,000 frames or 500 Mb or better
Image Viewing Depth:
26. 20- 400 mm or more
Imaging Modes / Techniques:
27. Tissue harmonic Imaging, Tissue Doppler Imaging, Color Angio, Tissue Velocity Imaging Tissue Imaging (Display real time Doppler shift information from moving tissue to better visualize and quantity myocardial function)
28. Capability to display time difference in myocardial motion in color for CRT (Cardiac Resynchronization Therapy)
29. Quantitative Strain Rate Imaging (Doppler & Speckle Tracking Rate): An advanced quantitative technique of Tissue Doppler Velocity of at least two chambers or more
30. Strain Rate (A measure of the contractile motion of Myocardium)
31. Contrast Harmonic Imaging capability
32. Vascular imaging software for carotids with IMT measurement
Stress Echo Mode (Physical and Pharmacological):
33. Integrated multistage stress echo system for advance and flexible stress echo Acquisition and measurement for LV B-Mode imaging
34. Quantitative analysis for contrast during stress examinations used with TDI / TVI protocols
System Requirement:
35.Storage Device: Built-in USB / CD /DVD Drive
36. Dynamic Range: Minimum 300Db or more
37. Communication Software: System Should conform to DICOM 3 communication Software for Image Storage, Print, Query / Retrieve, Network Communication
38. Permanent Licensed DICOM 3 Communication Software must be installable on External Individual Computer
39. 4 active transducers connectors for trans-Thoracic, Transoesophageal Probes and one for CW pencil probe
40. Should be light weight, capable of multiple centre frequencies on transmit for 2D, ColorDoppler PW, CW (Steerable) imaging and to performharmonics
41. Operating Requirement: AC 220 V & 50 HZ
42. Online pure shinewave UPS (Recommended by manufacturer) for at least 30 mins or better operational backup time for complete unit including Printer
43.Networking DICOM Enabled: System must be compatible with Picture Archiving & Communication System (PACS) / Hospital Information System (HIS)/ Radiology Information System (RIS) (The Procuring Agency and End-user todecide)
44. Export Formats: PDF/ JPEG, BMP/ MPEG, AVI/ Window Media, DICOM, RAW DICOM
45. The system must have provision to attach External Monitor via USB or VGA/ HDMI/DVI
*Complete with standard accessories
Linear Probe multi frequency to cover frequency of 6.0 – 13.0MHz
Multi frequency phased array sector probe to cover 2.0 – 4.0 MHz
Multi frequency Linear transducer with frequency of 3.0-9.0 MHz
Multi frequency convex transducer with frequency of 2.0-4.0 MHz
Multi frequency TVS transducer with frequency of 3.0-9.0 MHz
Operational & service manual.
2: Digital Portable X-Ray / Mobile DR
SPECIFICATION for Digital Portable X-Ray / Mobile DR
DIGITAL MOBILE X-RAY UNIT
Battery Driven, compact, easily transportable digital radiography system with Wireless flat panel detector mobile and inbuilt DAP meter suitable for bedside X-Rays, Intensive care unit and operation theatre use.
It must include the following:
A. The Generator:
1 It should be microprocessor controlled high frequency with output 40 KW or more.
2 KV range: 40 KV to 125 KV or more.
3 Tube current: 300 mA or more.
4 It should have an electronic timer with shortest exposure time – 1 ms or less.
5 It should have a digital display of mAs and KV.
1 Output should match the output of the generator.
2 It must be a rotating anode type with 2700 rpm or more.
3 Dual Focal spot size of X-Ray tube of 0.3 mm and 1mm.
4 Anode heat storage capacity should be 140 KHU or more.
5 Multi leaf collimator should be supplied with the system.
6 It should have an integrated DAP meter. The DAP meter reading should be visible on the software console with each image.
15. Flat Panel detector:
1 The flat panel detector made up of amorphous silicon with CsI scintillator size at least 17”x17”, wireless.
2 The detector pixel matrix should be 3,408 (h) x 2,800 (v) or more with DQE at least 70%. At 0 lp/mm
3 Pixel size should be 150 um or less.
4 The machine should have provision for detector storage compartment with charging facility .
5 The image processing time after exposure should not be more than 5 sec.
6 Weight of the detector shouldn’t be less than 3.5Kg
7 The wireless detector must have a lithium ion battery that allows more than 600 thorax exposures per recharge.
1 The machine should be able to run on mains as well as on battery supply. The system should allow at least 150 thorax exposures per battery recharge.
2 The unit should have separate batteries for driving the unit and generator.
3. Thebattery should be able to be charged from a normal 15A, 220-240V single phase socket in less than 4 hours, should be capable of generating at least 100 exposures.
E. Inbuilt Console:
1 The machine should have an integrated/ inbuilt console with a TFT touch screen with size at least 19 inches or more .
2 The console should be able to view the image, and provide post processing features, using touch screen.
3 The post processing features should include zoom, contrast and brightness adjustment etc.
4 It should have storage memory of at least 3000 images.
5 The software console should be able to control exposure parameters, generator setting, image processing patient data entry, study selection, printing and Dicom send.
Separate consoles are not acceptable.
F. Other Features:
1 The unit must have an effective braking system for parking, transport and emergency braking. The tube stand must be fully counter balanced with rotation in all directions.
2. The unit should have manual over ride and manual drive system incase of fail of battery power to atleast park in a safe postion.
3 It must have a telescopic/articulated arm for maximum positioning flexibility in any patient position. The angles in various planes to be specified by the manufacturer. The cables should preferably be concealed in the arm system.
4 The facility for exposures with remote control/ detachable exposure switch should be possible.
5 Detachable exposure switch should be supplied with a chord of at least 5 meters.
6 A grid of 6:1 ratio with size 17”x17” should be supplied.
7 The system should have European CE (Full Quality assurance, MDD 93/42/EEC) and USA FDA approval/CDSCO/BIS .
8 The system offered should have AERB Type approval / NOC for installation and use in India
G. Connectivity:
The machine should be fully network ready and it should be possible to transfer images and patient data from and to hospital network using LAN connectivity or wireless LAN.
H. Power Line Connection:
The unit should be able to operate on single phase power supply with plug in facility to any standard wall outlet with automatic adaptation to line voltage 200 to 240 volts, 15 Amp plug.
15. INDEPENDENT WORK STATION FOR POST PROCESSING
1 Post-processing Workstation with a high resolution monitor should be provided with the System. The GUI and post processing must be identical to the inbuilt console
2 The workstation should have a graphics card built in and support all common DICOM functions.
3 The monitor should have minimum 2.0 Mega Pixel resolution and have capability of portrait and landscape arrangements.
4 The processor should be of Dual Core Technology or better.
5 RAM should be of minimum 2GB.
6 The HDD should be of minimum 2x500 GB or better with RAID 5 configuration or better.
7 The workstation should have a DVD writer(inbuilt/external) for burning images.
8 The workstation software should support the following:
a) Patient list with capability to query/ search based on various criterion such as name, id number, date of examination etc.
b) Features such as DICOM Viewing, Windowing, Zoom, Pan, Magnify, Annotate, Mark, Measure, Reporting.
9 Connectivity to DICOM printers with multi format to be provided.
10 The workstation should have to connect to external storage devices and DICOM Servers, and the responsibility to connect to the any existing dicom servers /PACS/any other available Dry imager lies with the bidder/OEM.
11 This work station should be able to access study data stored in the inbuilt console with our manual sending/QR.
12 Dry Imager with 500 dpi resolution or more with 2 universal trays to print films.
J. Guarantee / Warranty: the whole unit including x-ray tube, detector all other accessories, batteries and consumables required to run this unit should be guaranteed for five years.
K. C.M.C: After expiry of guarantee/ warranty, CMC should be for five years which includes x-ray tube, detector all other accessories, batteries and consumables (Films) required to run this unit.
L. Retrofitted or refurbished units are not acceptable.
3: Electrosurgical Unit
Technical Specification: -
1. System should be US FDA / European CE Certificated
2. Price should be quoted in Indian currency
3. Make and Model should be mentioned
4. Advance micro controller based isolated Electrosurgical Generator having both Monopolar and Bipolar outputs designed for all surgical procedures.
5. Smart generator should be able to monitor changes in tissue impedance continuously and adjusts power.
6. Monopolar outputs should have three cutting modes: -
a. Low Cut for delicate tissue or Laparoscopic cases having maximum power of 300 W.
b. Pure cut for clean, precise cut in general surgery having maximum power of 300 W.
c. Blend mode for cutting with homeostasis having maximum power of 200 W. All cut modes should be able to adjust output power depending on tissue density by less than 15% or 5W, whichever is greater.
7. It should have three Coag Modes with maximum power of 120 W QTY UOM
a. Desiccate mode for low voltage contact coagulation suitable for Laparoscopic and delicate tissue work.
b. Fulgurate mode for efficient non-contact coagulation in most applications.
c. Spray mode should have randomized spray effect of varying amplitude and frequency for coagulating large tissue areas with minimum depth of necrosis.
8. It should have three bipolar modes with maximum power of 70 W to 80 W
a. Precise mode to have fine control of desiccation in delicate tissue.
b. Standard mode for applications at low voltage to prevent sparking.
c. Macro mode for applications on tissue with high resistance.
9. It should have patient plate monitoring facility and should give audiovisual alarm and deactivate output if contact between patient and patient plate is not proper to eliminate the risk of patient burns.
10. The unit should have two Mono polar outputs and one bipolar output.
11. It should have membrane touch power settings, LED display.
12. The unit should have individual digital display of power for Bipolar cut and coag, Monopolar cut and Monopolar Coag.
13. The unit should have temperature sensing cooling fan, which should operate automatically to protect generator from thermal damage.
14. It should have feature to check in problem diagnostics.
15. The unit should be software upgradeable.
16. Unit should have feature to save surgery wise programme
19. The unit should not have RF Leakage current more than 150 mA.
20. It should be Compact and light weight, weighing less than 10 Kg.
21. It should have safety standard of UL, CUL, IEC 601-2-2.
23. Should be supplied with an Equipment cart or Trolley for easy transport in operation theatres.
24. Online UPS to supplied with 30 minutes back-up.
25. Accessories
a. Monopolar Footswitch-1no.
b. Bipolar footswitch-1no.
c. Reusable Hand switching Pencil- 2nos. Electrode set- 2nos
d. Reusable Patient Plate -02 nos.
e. Bipolar Forceps non-stick – length 18 cm to 20cm, tip size 1.5mm to 2mm- blunt- 5 no.
f. Bipolar Forceps Cord-2nos
g. Universal Adapter-1no.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 28/2026-2027/Bio Medical Equipt/IGIMS/Store
NAME OF WORK:- A
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 1180
LOCATED WITHIN INDIA.
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
EMAIL ID OF AGENCY
Scheduled Brief description of goods Make: Model: Country of origin Qty./Nos. Ex-factory/ Ex-warehouse/ Ex-Showroom/ off-the shelf (a) Excise duty (If any) % and value. (b) GST (If any) % and value (c) Pcaking and forwarding charge (d) Inland transportation, isurancer for a period inculing 3 months delivery, loading/unloading and incidental cost till consignee site. (e) Incidental services (Including installation and commissioning, supervision, demonstration and training) at the consignee site. (f) Unit Price( at consingee site basis (g) a+b+c+d+e+f Total unit price (at consignee site) Basis Rs. 4x5 (g)
TOTAL AMOUNT IN FIGURE
TOTAL AMOUNT IN WORDS
Note: Bidders are requested to submit price bid in above format otherwise the bid submitted will be regected.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 28/ 2026-2027/Bio Medical Equipt/IGIMS/Store
NAME OF WORK:- A
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 1180
COMPREHINSIVE ANNUAL MAINTENANCE CONTRACT PRICES SCHEDULE
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
S. No. Item Description 1st Yr. 2nd Yr. 3rd Yr. 4th Yr. 5th Yr. 6th Yr. 7th Yr. Total Comprehensive annual maintenance contract over a period of seven years after expiry of warranty period of three years from the date of successful installation. (a+b+c+d+e+f+g)
a b c d e f g h i
1 Name of the equipment Make: Model: Qty:
2 Name of the equipment Make: Model: Qty:
3 Name of the equipment Make: Model: Qty:
4 Name of the equipment Make: Model: Qty:
5 Name of the equipment Make: Model: Qty:
6 Name of the equipment Make: Model: Qty:
7 Name of the equipment Make: Model: Qty:
8 Name of the equipment Make: Model: Qty:
9 Name of the equipment Make: Model: Qty:
10 Name of the equipment Make: Model: Qty:
11 Name of the equipment Make: Model: Qty:
12 Name of the equipment Make: Model: Qty:
13 Name of the equipment Make: Model: Qty:
14 Name of the equipment Make: Model: Qty:
15 Name of the equipment Make: Model: Qty:
16 Name of the equipment Make: Model: Qty:
17 Name of the equipment Make: Model: Qty:
18 Name of the equipment Make: Model: Qty:
19 Name of the equipment Make: Model: Qty:
20 Name of the equipment Make: Model: Qty:
Scope of contrct (details as mentioned in the clause No. - 13 of "Instruction to Bidder" & Clauses No. 3,4 and 5 of Condition of Condition of Contract".)
a) The rate of Comprehensive Annual Maintenace Contract as mentioned above shoul cover the Complete system.
Complete System should include the basic unit and allied supporting components like UPS, stabilizer Computer System,
Printer, De-ionizer, dehumififer etc to be supplied by the bidder along with basic unit.
b) Preventifve maintenance visit: Four Maintenance visits at ragular interval for usual mintenance & supervision failing which
25% of the contract amount per visit would be deducted as penalty.
c) Break down maintenance visit: As & when requrd
d) Response Time: Within 48 Hours.
e) Uptime Guarantee: 95% of 365 days
f) The above-mentioned charges should includes labour charges for maifntenance and breakdown visits per year, spares,
accessories and all type of consumables requird for the maintenaed charges: it should be clearly mentiond with frequency of
replacement and with rate. The validity of rate of suchf items should also be mentioned vclearly. What will be the rate of
such item must be mentioned.
g) Payment of Comprehensive Annual Maintenance Contract would be made on half yearly basis after completion of work and
satisfctory working report . In no case, advance payment is to be considerd.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Bidding 28.pdf
NIT • 1.00 MB
Tender Notice (Website).pdf
NIT • 0.55 MB
TechnicalSheet.xls
NIT • 0.09 MB
PriceBid.xls
NIT • 0.17 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .