Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹28.1 L+₹2.3 L (8.79%)Rejected-AOC SHOP NO 82 6 TRANSPORT NAGAR NARWAL JAMMU 180004 | JAMMU | JAMMU | J K | 180004 | L2 | Rejected-AOC SECOND LOWEST BIDDER | |
| 3 | L3₹28.5 L+₹2.7 L (10.5%)Rejected-AOC | L3 | Rejected-AOC THIRD LOWEST BIDDER | |
| 4 | L4₹29.0 L+₹3.2 L (12.3%)Rejected-AOC C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L4 | Rejected-AOC FOURTH LOWEST BIDDER | |
| 5 | L5₹29.3 L+₹3.5 L (13.7%)Rejected-AOC | L5 | Rejected-AOC FIFTH LOWEST BIDDER |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
16 Dec 2022, 6:00 pmClosed
GE NAGROTA
GE NAGROTA
Repair and Replacement of LT underground cable , LT OH line LT Panels and other Misc repair at 213 Transit Camp and Repair and maintenance of Motors Voltage stablizer with connected items at Nagrota under GE Nagrota
2022_MES_563722_1
GEN-45/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE NAGROTA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NAGROTA
₹80,000
Yes
10 Mar 2023
17 Nov 2022
19 Dec 2022
17 Nov 2022
16 Dec 2022
3 Dec 2022
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for electric poles, Stay foundation and under ground electric power cables and getting out in sof/loose soil .
Returning, filling including spreading, levelling, watering and ramming in layers not exceeding 25cm in hard dense soil.
Removing excavated surplus hard dense soil to a distance not exceeding 50M and depositing where directed at a level not exceeding 1.5M above the starting point.
Supply,laying and spreading in layers dry clean river sand for cable cushioning with a layer of sand 8 Cm depth before laying & 15 cm depth after laying the cable punned down to a depth of 10 cm above the top of the cable.
Supply & lay burnt bricks sub class 'B' in trenches for cable protection complete all as specified and directed by Engineer-in-Charge..
M & L for Laying connecting and testing of 1100 volts grade LT XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured, heavy duty eletric power cable with aluminium conductor of size and type complete all as specified and directed including dismantling and taking down existing old LT cable of any size and type from pole/duct/trench/floor/wall/pipe etc with cable end boxes, glands, bricks etc with necessary disconnection work and keep in safe custody for the following size of cables Note:- (i) Excavation and earth work, sand cushioning, bricks & cable protection pipe will be measured & paid under appropriate items of Schedule 'A' Cable of size 2 core 10 Sq mm
Cable of size 4 core 10 Sq mm
Cable of size 4 core 16 Sq mm
Cable of size 4 core 25 Sq mm
Cable of size 3.5 core 35 Sq mm
Cable of size 3.5 core 50 Sq mm
Cable of size 3.5 core 70 Sq mm
Cable of size 3.5 core 95 Sq mm
Cable of size 3.5 core 120 Sq mm
S&F heat shrinkable Straight though jointing kit 1.1 KV LT 4core XLPE cable cross sectional area 70 to 150 sqmm
S&F heat shrinkable outdoor termination cable jointing kit 1.1 KV LT 4core XLPE cable cross sectional area 25 to 50 sqmm
All as per ser here in above but cross sectional area 70 to 150 0sqmm
Supply & Fix Service cable /wire 1100 V flat twin core aluminium stranded conductor of size 6 Sqmm complete all as specified and directed.
Supply & Fix Service cable /wire 1100 V flat twin core aluminium stranded conductor of size 10 Sqmm complete all as specified and directed.
Material and labour for 80 mm dia light grade GI tubing with all fittings for cable protection laid in trenches, fixed on wall/pole with necessary fixing arrangements including dismantling the old pipe.
Material and labour for 50 mm dia light grade GI tubing with all fittings for cable protection laid in trenches, fixed on wall/pole with necessary fixing arrangements including dismantling the old pipe.
Material and labour for 40 mm dia light grade GI tubing with all fittings for cable protection laid in trenches, fixed on wall/pole with necessary fixing arrangements including dismantling the old pipe.
Material & Labour for cross arms, bracings, supports, clamps and back plate fabricated from structural steel sections including nuts, bolts,washers,welding,bending,drilling of holes for bolts in any shape or size as indicated and applying two coats of aluminium paint over a coat of red oxide primer including dismantling of existing mild steel cross arm with clamps from LT poles of any height, place and position.
Supply and fix and draw ACSR Weasel/Squirrelconductor of size 06 strands of aluminium of 2.59/2.11 mm dia and 1 strand of steel of 2.59/2.11 mm dia on LT poles, bringing the sag within limit fixing on Insulator/Cross arms by means of necessary binding with 16 SWG aluminium binding wire and providing alkathin pipe of approved quality for jumpers, reconnecting the service connections after removing the carbon material including taking down ACSR conductor of any size & type from LT poles at any height position and place complete all as specified and directed by Engr-in-Charge.
Supply and fix LT Pin type insulator, porcelain, vitreous, white, brown or green insulator including one galvanised iron mild steel spindle two galvanised iron washers and one galvanised iron nuts, 100 mm height, 65 mm dia for conductor 1100 volts grade including dismantling of existing LT pin type insulator from HT poles of any height, place, and position.
Supply and fix LT shackle type insulators, vitreous, porcelain brown, white or green insulators for working pressure of 1100 volts grade of 90 mm dia, 75mm height including galavnised mild steel strips 31 x 3 mm size and 12 mm dia bolts, nuts, and washers on existing cross arms including dismantling of existing LT shackle type insulator from LT poles of any height place and position.
Material & Labour for stay asembly comprising of stay bow (4000 x 14mm), stay rod 215 cm long and 20 mm dia with nuts, stay plate 300 x 300 x 6 mm thick and 2 nos of thimble complete as shown in electric plate no 1 of SSR part-1 connected to loop type insulator, including dismantling old unserviceable stay assembly complete including loop insulator wire etc from LT poles NOTE :- Earth work excavation, concrete and loop type insulator shall be measured and paid separetely under relevent items of Sch 'A'.
Supply and fix LT loop type insulators, vitreous, porcelain brown, white or green insulators for working pressure of 1100 volts grade of large size with over all dimensions 90 x 140 mm clearance of hole 25.50 mm including dismantling of existing LT loop type insulator from LT poles of any height place and position.
S&F Galvanised stay wire stranded of size 7/4 mm including necessary binding, strengthening complete all as directed
Material and labour for cement concrete 1:4:8 type D2 using 40mm graded crushed trap stone aggregate for foundation of poles/stays.
Material and labour for PCC (1:2:4) type B-2, using 40 mm graded crushed stone aggregate for making good the road cutting all as directed by Engr in Charge.
Material and labour for PCC (1:3:6) type B-2, using 40 mm graded crushed stone aggregate for making good the road cutting all as directed by Engr in Charge.
Material and labour for lightning arrester expulsion type high tension complete with all fittings transmission class discharge capacity 65 kilo amps suitable for 11 KV including necessary connections with Over head lines & earthing fixed on 2/4 pole structure, including dismantling the old unserviceable one.
Material and labour for switch Air break gang operated Triple pole, mechanically operated mounted on insulator & steel frame with operating mechanisum worked from ground level for current rating upto 200 Amps 11000 Volts all with male & female contacts, post insulator 15 Nos, operating rod, handle etc and renewal of jumpers with heavy duty alkathine pipe cable connections including dismantling of old unserviceable switches vertical/horizontal mounted, including insulator & operating mechanisum for repair/replacement of broken/worn out components and insulators etc complete.
Material and labour for drop out fuse assembly expulsion type single pole for 11 KV, 100 amps capacity complete consisting of galvanised steel base plate fuse carrying brackets channels with post insulator, fuse carrier fiber glass tube with fuse eliment complete including dismantling the old unserviceable one.
Repair, maintenance & overhauling of existing 11 KV A.B GOD switch of any type & size including cleaning of insulator,replacing male & female contacts (where as required),greasing & oiling to operating mechanisum,setting of contacts,renewals of connections etc all for smooth fuctioning of A.B GOD switch complete all as directed by Engineer- in- charge
Restringing of existing LT over head line of ACSR conductor after opening of binding wire from insulator & bringing the sag within limit rebinding the same with insulator with 16 SWG aluminium wire all including renewal of jumpers with providing alkathin pipe of approved quality of jumpers, reconnecting the service connection after removing the carban material complete all as directed by Engineer in Charge.
Material and labour for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25M deep below natural ground level ) with top edge of plate not less than 1.5M below normal ground level, surrounded from all sides alternate packed layer of char coal dust and comman salt and electrode connected with galvanised iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR part I including necessary earth work in type strata, foundation of pit and wall using PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate 40 mm thick pit cover slab using RCC 1:2:4 type B0 using 12.50 mm graded crushed stone aggregate with 6 mm dia MS bar @ 100 mm C/C both ways GI medium grade 20 mm dia pipe for watering including funnel with wire mesh and 15 mm bore GI light grade pipe for earth lead wire protection up tp 7.5 mtr complete all as directed including testing complete on completion.
-Ditto- all as per sl item No. 30above but using 32x6 mm GI earth strip as a earth lead & 40 mm dia light grade GI protection pipe complete all as specified & directed Note for item No.30 & 31 (i) GI wire/strip or protection pipe 15mm/40mm dia upto 7.5 RM included the quoted rate. (ii) The qty above the 7.5 RM shall be measured & paid separetely
M&L for earth continuity conductor or main earthing lead 4 mm dia GI or steel wire fixed to wall on batten or recessed or buried in ground or drawn in conduit/pipe all as required at site.
Supply & fixing for GI strip 32x6mm on wall/batten or recessed or buried in ground all as directed by Engineer-in-Charge.
Feeder piller box out door type ‘factory made’ made out from 16 SWG MS sheet supported with legs of 45cm long made of iron angle 25x25x4mm thick of size 75cm x60cm x45 cm with 04 Nos aluminium bus bar of 400 Amps mounted on porcelain insulator duly drilled hole for cable connection including front and rear side opening with locking arrangement provn for incoming and outgoing cables with glands including painting with two coat of smoke grey synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 30 cm above ground level with suitable foundation, rendering 15 mm in CM 1:6 and two coats of cement base paint and the rates shall be inclusive in the quoted rate.
Supply & Fixing in replacement MCCB 4 pole 160 amps 50Hz 415 volts adjustable type with reputing cap 36KA
Supply & Fixing in replacement MCCB 4 pole 250 amps 50Hz 415 volts adjustable type with reputing cap 36KA
Supply & Fixing in replacement MCCB 4 pole 400 amps 50Hz 415 volts adjustable type with reputing cap 25KA
Supply & Fixing in replacement MCCB 3 pole 125 amps 50Hz 415 volts adjustable type with reputing cap 25KA
Supply & Fixing in replacement MCCB 3 pole 160 amps 50Hz 415 volts adjustable type with reputing cap 25KA
Supply & Fixing in replacement MCCB 3 pole 200 amps 50Hz 415 volts adjustable type with reputing cap 36KA
Supply & Fixing in replacement MCCB 3 pole 250 amps 50Hz 415 volts adjustable type with reputing cap 36KA complete all as specified and directed.
S & F in repair MCB TPN 32 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified and directed.
S & F in repair MCB TPN 63 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified and directed.
S & F in repair MCB SPN 32 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified and directed.
S & F in repair MCB SPN 40 to 63 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified and directed.
Supply and fixing in replacement indicator lamp set (RYB) complete
M & L for preparation of old painted steel surface by cleaning, removing rust, grease and apply one coat of synthetic enamel paint of approved shade (Spray painting outside/inside surface) of the feeder pillar box / LT Panels Outdoor / Indoor type of approximate size 900 x 600 x 500 mm complete with prior permission of Engineer in Charge. Base frame with Black enamel paint (Rate quoted shall deem to be included of Numbering of Panel/ Feeder pillar) complete all as specified.and directed by Engineer charge
M & L for Bakelite strip connector, 4 way, 100 Amp cap including electrically connections including taking down old item complete all as specified.
Taking down existing junction box and 'S & F junction box made from FRP sheet 2.00 mm thick readymade of size 400mm x 300mm x 200mm fixed to pole/Wall with MS clamp 25 x 5 mm and suitable size of nut, bolts and washers complete all as specified.
S & F in repair aluminium bus bar of required size, shape, length and making drilling for fixing in LT panel /feeder pillar/change over switch etc including necessary addition / alteration to existing panel with welding cutting to steel structure and providing new steel itemsand taking down old item complete all as specified.
M & L for servicing of feeder pillar box/ LT Cubical Panel , after dismantling the incoming and outgoing connections from MCCB/ Bus bar and replacing the old burnt/ overheated unserviceable lugs, terminals, nuts, bolts, washers supporting insulators etc and checking the serviceability of MCB / MCCB, earth continuity conductor and strip etc complete all as specified. Note: (i) Spare parts such as terminals, lugs, nut bolts, insulators etc will be measured and paid under respective item in the schedule, (ii) Labour for fixing charges of the spare parts deemed to be included in the rate quoted for the items.
Supply only aluminium lugs of any type / shape of capacity 150 Sqmm
Supply only aluminium lugs of any type / shape of capacity 120 Sqmm
Supply only aluminium lugs of any type / shape of capacity 95 Sqmm
Supply only aluminium lugs of any type / shape of capacity 70 Sqmm
Supply only aluminium lugs of any type / shape of capacity 50 Sqmm
Supply only aluminium lugs of any type / shape of capacity 35 Sqmm
Supply only aluminium lugs of any type / shape of capacity 25 Sqmm
Supply only aluminium lugs of any type / shape of capacity 16 Sqmm
Supply only GI Nuts, bolts, screws, washers of required sizes
Supply only bus bar Insulators Epoxy type as required at site min size 45mm x 50 mm dia
S&F Extension link four set for MCCB of cap 125/160 Amp. Make: Legrand / Havells / Standard / IndoAsian
S&F Extension four link set for MCCB of cap 250 Amp. Make: Legrand / Havells / Standard / IndoAsian
S&F Extension four link set for MCCB of cap 400 / 630 Amp. Make: Legrand / Havells / Standard / IndoAsian
S&F current Transformer of rating from 100/5 to 400/5 CT ratio in existing panel complete all as specified. Make : AE / Kappa
Taking down rusted portion of sheet of feeder pillar boxes, damaged hinges etc and supply and fix new hinges heavy duty type, MS sheet patch work by cutting, welding and fabricating at site as required not exceeding 0.5 Sqm , painting with two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified.
S&F locking arrangement with aldrop bolt set complete of size 225 mm to existing feeder pillar box by welding including taking down old worn out locking arrangement complete all as specified.
S&F Stainless Steel Double Compression Cable Glands, Size: up to 20mm
all as per item above but of size 25 - 40 mm
all as per above but of size 50 - 80 mm
Disconnecting the electrical connection for taking out unserviceable centrifugel pump any size from the foundation including other accessories carrying to workshop for repair complete all as specified and directed. Note: Spare part measured and paid under relivent items.The cost of transportation to workshop is deemed to be included in the quoted rate.
(a) Replacement of implers of existing size as directed by Engr-in-Charge
(b) Replacement of gland bush including gland packing of existing sizeas directed by Engr-in-Charge
(d) Replacement of center guide of existing size as directed by Engr-in-Charge
(e) Replacement of pump shaft of existing sizeas directed by Engr-in-Charge
(f) Replacement of neck ring any size as directed by Engr-in-Charge
Remetaling, grinding, polishing and balancing of shaft for induction motor of capacity 5 to 15 HP. Note: (i) The rate for replacement of bushes, shaft sleeves etc required for making the shaft functional shall be included in the quoted rate).
All as per item above but of cap 20 to 30 HP
All as per item above but of cap 40 to 60 HP
All as per item above but of cap 75 to 125 HP
Supply and fixing in replacement of ball bearing of induction motor/pump of cap 5 to 15 HP as per existing size complete all as specified and directed
Supply and fixing in replacement of ball bearing of induction motor/pump of cap 20 to 30 HPas per existing size complete all as specified and directed
Supply and fixing in replacement of ball bearing of induction motor/pump of cap 40 to 60 HP as per existing size complete all as specified and directed
Supply and fixing in replacement of ball bearing of induction motor/pump of cap 75 to 125 HP as per existing size complete all as specified and directed
Supply and fixing in replacement of star coupling suitable for connecting centrifugal motor and pump of capacity upto 75 complete all as specified and directed.
Supply and fixing in replacement of Tyre coupling suitable for connecting centrifugal motor and pump of capacity upto 75 HP complete all as specified and directed.
Supply and fixing in replacement of Tyre coupling suitable for connecting centrifugal motor and pump of capacity 125 HP complete all as specified and directed.
Material and labour for rewinding of centrifugal motor of any description, dismantling and strip opening of the motor, removing the old existing burnt windings, cleaning the slots and rewinding of the electric motor of 3 phase, 415 Volts, 50 Hz AC supply with existing gauge copper wire (Make: ALAS/FINOLEX) including insulating material such as illumines paper, etherized paper, cotton waste, glass sleeves insulating varnish etc, refixing on existing platform and connected all the electric connections and mechanical connections and testing the complete pumping set up to the entire satisfaction of the Engr-in-Charge for Upto 10HP capacity complete all as specified and directed.
All as per item above but capacity 15 HP .to 20 HP
All as per item above but capacity 25HP to 30 HP
All as per item above but capacity 35 HP to 40 HP
All as per item above but capacity 50 HP to 60 HP
All as per item above but capacity 60 HP to 75 HP
All as per item above but capacity 125 HP.
Disconnecting the electrical connection for taking out unserviceable submersible pump set any size from the bore well including column pipe and other accessories carrying to workshop for repair complete all as specified and directed. Note: Spare part measured and paid under relivent items.The cost of transportation to workshop is deemed to be included in the quoted rate.
M & L for Lowering the servicable submersible pump set any size after repair shifted to in its orignal location joint with column pipe and other accessories connecting to all electrical connection testing and commissioning the same complete all as specified and directed.Note: The cost of transportation from workshop is deemed to be included in the quoted rate.
M & L for Replacement the defactive part of submersible pump sets are as under:- (a) Thrust plate of submersible motor 5 HP to 20 HP
(b) Thrust plate of submersible motor 25 HP to 40 HP
(c) Thrust bearing of submersible motor 5 HP to 20 HP
(d) Thrust bearing of submersible motor 25 HP to 40 HP
(e) Gun metal bushes for submersible motor 5 HP to 20 HP
(f) Gun metal bushes for submersible motor 25 HP to 40 HP
(g) Remetaling,grinding,polishing and balancing of shaft for submersible motor 5 HP to 20 HP
(h) Remetaling,grinding,polishing and balancing of shaft for submersible motor 25 HP to 40 HP
(i) Coupling arrangement with key of submersible motor of cap 5 HP to 20 HP
(j) Coupling arrangement with key of submersible motor of cap 25 HP to 40 HP
(k) Stainless steel shaft of submersible pump of cap 5 HP to 20 HP
(l) Stainless steel shaft of submersible pump of cap 25 HP to 40 HP
(m) Impellers for submersible pump set 5 HP to 20 HP
(n) Impellers for submersible pump set 25 HP to 40 HP
(o) Bowl bush for submersible pump set 5 HP to 20 HP
(p) Bowl bush for submersible pump set 25 HP to 40 HP
(q) Neck ring for submersible pump set 5 HP to 20HP
(r) Neck ring for submersible pump set 25 HP to 40HP
M & L for removing the burnt winding wire of the submirsable motor cleaning the slots for rewinding, and rewinding the motor with super enamelled copper winding wire superior quality as per exisitng gauge and size, varnishing, drying, replacement of bearings and assembling the motor of Cap up to 12.5 HP complete all as specified and directed.
M & L for removing the burnt winding wire of the submirsable motor cleaning the slots for rewinding, and rewinding the motor with super enamelled copper winding wire superior quality as per exisitng gauge and size, varnishing, drying, replacement of bearings and assembling the motor of Cap up to 15 HP to 40 HP complete all as specified and directed.
M & L in replacement of sand guard assembely of 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of sand guard assembely of 12.5 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of water filling plug of 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of water filling plug of 12.5 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of bush housing set including bush of 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of bush housing set including bush of12. 5 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of upper housing set of 40HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of upper housing set of 12.5 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of lower housing set of 40HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of lower housing set of 12.5 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of mechanical seal of 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of mechanical seal of 12.5HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of seal guide sleeve of 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of seal guide sleeve of 12.5 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of startor assembly along with winding wire of 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of startor assembly along with winding wire of 12.5 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of roter assembly of 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of roter assembly of 12.5 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of cable connector sleeve and spring guide plate of 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of cable connector sleeve and spring guide plate of 12.5 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of tie rod/tie bolt of 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of tie rod/tie bolt of 12.5 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of diaphragm along with diaphargm spring of 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of diaphragm along with diaphargm spring of 12.5 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of doom nut and "O" ring of 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of doom nut and "O" ring of 12.5 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
Disconnecting the electrical connection for taking out unserviceable VT Motor any size from the foundation of bore well and other accessories carrying to workshop for repair,after repair VT Motor shifted to the existing bore well and re installation in orignal position including all electrical connection testing and commissioning complete all as specified and directed. Note: Spare part measured and paid under relivent items.
M & L for removing the burnt winding wire of the VT motor, cleaning the slots for rewinding, and rewinding the motor with super enamelled copper winding wire superior quality as per exisitng gauge and size, varnishing, drying, of Cap 30 to 40 HP complete all as specified and directed.
M & L for Lowering the VT pump any size after repair shifted to in its orignal location joint with column pipe,motor and other accessories connecting to all electrical connection testing and commissioning the same complete all as specified and directed.Note: The cost of transportation from workshop is deemed to be included in the quoted rate.
M & L for Replacement the defactive part of VT pump sets are as under up to 40 HP Submercival Motor :- (a) Gun metal impeller
(b) Neck Ring
(c) gland plate
(d) Studs
(e) Stainless steel line shaft 3 metre long
(f) Top shaft 1.5 metre long
(g) Guide spider 6"
(h) Guide spider bush
(j) Stainless steel sleeve
(k) Shaft coupler
(l) Stuffing box
(m) Thrust bearing
(n) B Kulf bush
Opening and checking and repair of fully automatic solid state (CB-4SA) fault analyzer cum control system with (a) Low voltage cut off 350 Volt AC (b) High Voltage Cut off 450 Volt AC (c) Pick up volt 360 Volt AC (d) Cut off time- Fraction of time (e) Unbalanced volt cut off- a deference of 35 Volt to 45 Volt between any two phase with 3 phase over load protection (Make: Guardian) once in a month to make it functional at all the times for smooth operation of pumping set installed at various location of water supply installations. Note : Minor parts of the system will be replaced during checking and the cost of the same is deemed to be included in the quoted rate.
Disconnecting and transport to workshop and complete conection after disconnecting of voltaze stablizer, opening for repair automatic voltage stabilizer for automatic operation air natural/oil cooled servo controlled type input voltage 260-440V and output voltage 420 V capacity 25 to 30 KVA complete all as specified and as specified and as directed (Note :- (i) Cost of transportation of voltage stabilizer to workshop and back after repair complete is deemed to be included in the quoted rate. (ii) Replacement of the parts if any found worn out/defective shall be measured and paid for separately.
All as per srl item above but of Capacity 50 KVA to 75 KVA complete all as specified and directed.
All as per srl item above but of Capacity 160 KVA to 200 KVA complete all as specified and directed.
All as per srl item above but of Capacity 400 KVA complete all as specified and directed.
Supply and fixing in replacement of dimmer coil with super enameled copper winding wire of existing make and size complete in all respect including varnishing tapping and insulating material to get same capacity of 25 to 30 KVA complete all as specified and directed.
All as per srl item above but of Capacity 50 KVA to 75 KVA complete all as specified and directed.
All as per srl item above but of Capacity 160 to 200 KVA complete all as specified and directed.
All as per srl item above but of Capacity 400 KVA complete all as specified and directed.
Dismantling of primary and secondary coils carefully taking out winding wire preparing for rewinding with super enameled copper winding wire of appropriate guage with allied insulating material varnish the winding with air drying insulating varnish heat treatment etc of 50 KVA to 75 KVA complete.
All as per srl item above but of Capacity 80 KVA to 150 KVA complete all as specified and directed.
All as per srl item above but of Capacity 160 to 200 KVA complete all as specified and directed.
All as per srl item above but of Capacity 400 KVA complete all as specified and directed.
Supply and fixing in replacement of electronic circuit plate complete with DC transformers complete all as per Upto 150 KVA and shape (PCB cold) complete all as specified and directed.
Dismantling of old servo motor and supply and fix new servo motor of upto 150 KVA Voltaze Stablizer and shape along with all connected accessories and cap complete all as specified and directed.
Dismantling of old carbon bush with carbon holder incl S & F new carbon bush with carbon holder of upto 150 KVA Voltaze Stablizer size and shape complete
Supply and fixing in replacement of brass studs fixed for upto 150 KVA Voltaze Stablizer input and output of stabilizer with brass nuts along with all necessary connection complete all as specified for any capacity of Voltage Stablizer
Supply heating and filling of transformer oil EHV grade having dielectric strength not less than 40 KV (Rms) with a 4 mm gap with high viscosity in transformer as per IS-335 of 1983 all as specified and directed.
Supply and fixing in replacement, of power contractors 3 phase, 3 pole, 415 Volts, 50 Hz suitable for operation of a load of capacity of 70 Amps.
Supply and fixing in replacement, of power contractors 3 phase, 3 pole, 415 Volts, 50 Hz suitable for operation of a load of capacity of 110 Amps.
Supply and fixing in replacement, of power contractors 3 phase, 3 pole, 415 Volts, 50 Hz suitable for operation of a load of capacity of 185 Amps.
Taking down of manually operated oil immersed star delta starter of any capacity from its existing position, removing the transformer oil in a suitable container for reuse, replace the old unserviceable fixed and moving contract, over load coils, no volt coil complete and refixing the starter assembly in its existing position connecting the complete system and making the starter functional complete all as specified and directed.
Dismantling of reduction gear flocculators/pre sedimentation tank type V 400 ratio 1:60 Make Radicon with replacement of V belts, gear oil repair to gears and shaft with greasing of the flocculator, alingnment complete all as specified and directed
M&L for making good and smooth postion of floculators track and wheel,dismantilg the wheel and repair and greasing complete ,check the whole track and replace broken and unallined part of track complete for smooth functioning of flocculators complete all as specified and directed
M&L for redevelopement of air compressor of adequate capacity (not less than 250 cfm) till the avilability of sand free clear water, subject to minimum 24 Hrs of operation of air compresssor. (rate shall include lowering, Unlowering of submersible pump, transportation of necessary T&P, filling, jointing and drainage of adequate size of air compressor as specified and directed.)
Supply and fixing in replacement of submersible cable un armored PVC insulated & sheathed copper conductor cable 1100 Volts grade of size 35 Sqmm 3 core complete all as specified and directed.
Supply and fixing in replacement of MCCB 400 Amps 4 pole 415 Volts 36 KA with adjustable thermal and adjustable magnetic settings fixed in repair as per existing at site and all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of MCCB 250 Amps 3 pole 415 Volts 36 KA with adjustable thermal and adjustable magnetic settings fixed in repair as per existing at site and all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of MCCB 200 Amps 3 pole 415 Volts 36 KA with adjustable thermal and adjustable magnetic settings fixed in repair as per existing at site and all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of MCCB 100 Amps 3 pole 415 Volts 16 KA fixed type as per existing at site and all as specified and directed by Engr-in-Charge
Supply and fixing in replacement of volt meter with CT as per existing size complete all as specified and directed.
Supply and fixing in replacement of Amp meter with CT as per existing size complete all as specified and directed.
Supply and fixing in replacement of indicator lamp assembly complete LED type suitable for the existing system supply voltage for the existing system supply voltage 230V / 440 V AC including taking down old lamp assembly
Repair and Maintenance of ACB 800 Amps and replacement of any defected part of ACB and reinstalltion in panel complete all testing as per directed by Engr -in -charge Note :All spare parts used for repair rate are include in above schedule Job -1
Balbir Enterprises
SHSS ASSOCIATES
MAMTA ENTERPRISES
M/S RAJ ENGINEERS
Bidder Name
MAMTA ENTERPRISES
M/S RAJ ENGINEERS
Kalsi Engineers and contractors
Balbir Enterprises
SHSS ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .