Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.3 LAccepted-AOC AT 381 341 SARITA APARTMENT P O KHARAGPUR KHARIDA MAIN ROAD MIDNAPORE WEST WEST BENGAL 721301 | MEDINIPUR WEST | WEST BENGAL | 721301 | L1 | Accepted-AOC Lowest bid value | |
| 2 | L2₹49.9 L+₹3.5 L (7.62%)Rejected-AOC 179 143 1 INDA NEAR SHAKTI BHAVAN KHARAGPUR 721305 | KHARAGPUR | PASCHIM MIDNAPORE | WEST BENGAL | 721305 | L2 | Rejected-AOC Higher bid value | |
| 3 | L3₹52.6 L+₹6.2 L (13.4%)Rejected-AOC | L3 | Rejected-AOC Higher bid value |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
6 Jun 2022, 6:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) KALAIKUNDA
CWE (AF) KALAIKUNDA, KALAIKUNDA AIR FIELD POST, WEST MIDNAPORE, WEST BENGAL
PROVISION OF EXTERNAL SERVICES FOR PROJECT NFS AT AF STATION KALAIKUNDA
2022_MES_516819_2
8396/KKD/24/E8
Open Tender
Civil Works
Item Rate
180 days
AF STN KALAIKUNDA
Class D category b(ii)
2 documents required · 2 mandatory
₹500
GE (AF) KALAIKUNDA
₹86,000
Yes
1 Jul 2022
18 May 2022
8 Jun 2022
19 May 2022
6 Jun 2022
25 May 2022
19 May 2022 - 21 May 2022
Amount
B/R PORTION M & L for surface dressing n exc 15 cm deep in soft/loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in soft/loose soil for foundation complete all as specified and directed.
Returning, filling in, inluding spreading, levelling, watering and well ramming in layers n. exc 25cm in hard/ dense soil complete all as specified and directed.
Removing eaxcavated soil material exc. 250m but n.exc 500m and depositing where directed complete all as specified and directed.
M&L moorum/ red bajri filling in floors or paving’s, laid in the layer n.exc 15cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M & L for broken stone or boulders hardcore of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
Material & Labour for plain cement concrete (1:4:8), type D-2, (using 40mm graded stone aggregate ) in foundations, filling, mass concrete etc complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft & raft beams, sides & soffits of foundation & plinth beams; and similar work; verticle or to batter rough finished surfaces of concrete flat complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers,columns, and stanchions Rough finished surfaces of concrete Circular on plan complete all as specified and directed.
M&L Use and Waste of form work rough finished two sides and soffits for lintels/lintel bands and roof beams etc complete all as specified and directed.
M&L Use and waste for Form work to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed.
M&L Use and waste of form work to soffits of suspended slab such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick of rough finished flat surfaces complete all as specified and directed.
M&L RCC M-25 design mix using 20 mm graded aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L RCC M-25 design mix using 20 mm graded aggregate in Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L RCC M-25 design mix using 20 mm graded aggregate in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L RCC M-25 design mix using 20 mm graded aggregate in Chajjas complete all as specified and directed.
M&L RCC M-25 design mix using 20 mm graded aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M & L for TMT bars 10 mm dia and over cut to length bend to shape required including cranking hooking ends and binding with and incl. MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
All as per item No. 18 but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
M & L for damp proof course 25 mm thick in cement concrete 1:2:4, type B0(using 12.5mm aggregate) to horizontal or vertical surfaces including necessary formwork complete all as specified and directed.
M & L for applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 cu. m. per sq. M complete all as specified and directed.
Material and labour for 100 mm thick PCC 1:3:6, type C2 using 40mm graded stone aggregate as in sub base to flooring complete all as specified and directed.
Material and labour for 25 mm thick PCC 1:2:4, type B1 using 12.5 mm graded stone aggregate as in floor complete all as specified and directed.
M & L for brick work with fly ash brick, straight curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and directed.
M/L for brick work with fly ash brick, straight curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
M & L for rendering 10mm thick cement plaster in CM(1:6) on fair faces of brick work or concrete surface finished even and smooth without using extra cement or lime complete all as specified and directed.
M & L for rendering 15 mm thick cement plaster in CM(1:4) on fair faces of brick work or concrete surface finished even and smooth without using extra cement mixed with water proofing compound complete all as specified and as directed. Note: - Water proofing compound shall be measured and paid seperately.
Supply only liquid water proofing compound complete all as specified and directed.
Material and labour for 5mm thick in CM 1:3 rendering on fair faces of brick or concrete surfaces on ceiling finished even and smooth without using extra cement complete all as specified and directed.
M & L for applying two coat of exterior acrylic emulsion paint first quality in camouflage pattern over a coat of primer including necessary preparation of old/previously untreated surfaces of wall etc complete all as specified and as directed.
Material and labour for preparation of newly plastered surfaces and applying three coats of white wash on ceilings complete all as specified and as directed.
M & L for applying three coats of white wash on new wall surface including preparation of surface plastered or unplastered complete all as specified and directed
M & L non-skid coloured ceramic tiles 7 to 8mm thick, area of each tile exc 0.11 sqm and n.exc 0.18sqm, in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15mm thick screed bed in CM 1:6, complete all as specifed and as directed.
M & L for coloured glazed ceramic tiles in vertical surface 350 x 250 x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement. as in dado including 10mm thick backing coat as in CM 1:4, complete all as specified and as directed.
S&F for steel ventilator with top hung shutter including hinges, steel peg stay complete all as specified and as directed
S & F figured glass, pin head type and glazing with oil putty in squares 4 mm thick, n exc 0.5 Sqm in each panel as in ventilatorall as specified and directed.
Preparation of new steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
S & F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and as directed.
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles & wood grain printed PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of wood grain printed PVC sheet to be fitted in the M.S frame welded/ sealed to the 5mm thick x15mm wide decorative PVC beading of 10mm x 10mm (90 degree) , & joined together with solvent cement, in the frame at site as per specification & drawing complete all as specified and as directed.
M & L for 150mm long aluminium barrel tower bolts of extruded section and fixed complete all as specified and as directed.
M & L for 150 mm extruded aluminium alloy handles, fabricated type anodized complete all as specified and as directed.
Supply and fix for butt hinges of size 100mm, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and as directed.
S&F vitreous china wash down water closet (pedestal pattern) pan, white(excluding fixing bolts, flushing cistern and flush pipe) etc. complete all as specified and as directed.
S & F plastic seat cover white closed pattern with flat bottom and cover and mild CP aluminium hinging device complete all as specified and as directed.
S & F PVC 10 ltrs capacity low level flushing cistern complete set including flush pipe complete all as specified and as directed.
S & F vitreous china wash basin, white flat back size 550x 400 mm including. brackets ,cutting for pinning in ends of brackets as fixed complete all as specified and as directed.
S & F vitreous china Urinal, Half stall type,(580 x 380 x350 mm min) white(excluding flushing cistern and flush pipe) fixed complete all as specified and as directed.
S&F Urinal spreader of PTMT any colour for fixing with 15mm dia pipe (min. weight 60gms) complete all as specified and as directed.
S & F PVC waste pipe, 32 mm dia for WHB or sink complete all as specified and as directed.
S & F CP health faucet with complete set complete all as specified and as directed.
S&F Soap dish, Vitreous China white, approximate size 160x160x90mm complete all as specified and as directed.
S & F sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with aluminium alloy brackets & guard rail 60cm long all as specified and directed.
S&F Grating doom 100 mm dia of PTMT (min. weight 25 gms) complete all as specified and as directed.
S&F for Rotational moulded polyethylene 500Ltr water storage tanks(cylindrical vertical with closed top)hoisted and fixed in position complete all as specified and as directed.
S & F Ball valves 15mm bore high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe & fixed. (min weight 15mm-142 gms) complete all as specified and as directed.
S & F 20mm dia gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
M & L 20mm bore steel tubing medium grade including all fittings fixed in walls or laying on floors complete all as specified and as directed.
M & L 15 mm steel bore tubing medium grade including all fittings fixed in walls or laying on floors complete all as specified and as directed.
S & F 15mm bib tap chromium plated with crutch or butterfly handle screwed for iron pipe complete all as specified and directed.
S&F 15mm bore Pillar taps, CP fancy type with capstan heads ,screwed down high pressure with long screwed shanks and fly nuts complete all as specified and directed.
S & F 15mm stop valve angular type cromium plated fancy type , screwed down , high pressure, with crutch or butterfly handles complete all as specified and directed.
S & F PVC connection pipe 15mm size with PTMT nuts of length 600mm complete all as specified and as directed.
M & L for 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed.
S & F plugs (waste) with rings, waste fitting brass chromium plated for wash hand basin etc. with long screwed shanks and fly nuts flange end bedded in red lead cement & other end fixed etc. for 32 mm bore of pipe complete all as specified and as directed.
S & F 110 mm dia unplasticised PVC pipes of pressure rating 10kgf/sqcm fixed complete to walls, ceilings or in floors etc, any type of pipe complete all as specified and as directed.
S & F 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S & F 110 mm dia PVC (SWR) branch piece, double, (double Y) equal or unequal complete all as specified and as directed.
S & F 110 mm dia PVC (SWR) bend any radius complete all as specified and as directed.
M & L for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement all complete all as specified and as directed.
S & F 110 mm dia PVC (SWR) vent cowl complete all as specified and as directed.
M & L for PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in padding concrete to maintain slope complete all as specified and as directed.
M &L for 10 mm thick rendering on fair faces of brick/concrete surfaces in CM 1:4 mixed with liquid water proofing compound @ 0.25% by the weight of cement or as per manufacturer's instructions complete all as specified and as directed. Note: - Supply of Liquid water proofing compound shall be measured and paid separately.
M&L for providing roof treatment complete all as specified and directed as described in the following process: - i) Applying a coat of cold applied polymeric modified bituminous primer @ 0.30 Kg/Sqm. ii) Providing APP based polymeric membrane with mineral top finish minimum weighing 3.0 Kg/Sqm and minimum 3 mm thick , reinforced with polyester non-woven fabric (weight not less than 160 gms/sqm) laid on primed surface by torch application as per the manufacturer's instructions with side and end over lap of 100mm. iii) Applying a coat of Industrial bitumen 85/25 @ 1.2 Kg/Sqm. Note: The work of water proofing treatment shall be got executed through manufacturer or authorised applicator of the manufacturer only complete all as specified and as directed.
M&L 75mm thick PCC type B-1, (1:2:4) using 20mm graded stone aggregate Finished even & smooth without using extra cement as in plinth protection including necessary joint filling by bitumen Grade B complete all as specified and as directed.
Brickwork with flyash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and as directed.
Material and labour for PCC 1:2:4, type B1 using 20mm graded stone aggregate as in coping/benching including necessary form work complete all as specified and as directed.
M&L Precast cement concrete type B1 (1:2:4) using 20 mm graded aggregate set in CM(1:4) in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and as directed.
M & L Cement concrete 1:3:6 type C-2 bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in 150 mm bore of pipe complete all as specified and as directed..
M & L for Salt Glazed stone ware drain pipes laid in trenches and jointed 150 mm bore of pipe complete all as specified and as directed.
Excavating over areas, exc 1.5m but n exc 3.0m deep & getting out in soft / loose soil all complete all as specified and as directed.
M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work; exc. 200m thick (Horizontal or sloping) Fair finished surfaces of concrete flat complete all as specified and as directed.
M&L RCC type B1 (1:2:4) using 20 mm graded aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M & L for excavation over areas, soft/loose soil n. exc. 1.5 m deep and getting out complete all as specified and as directed.
Rolling & consolidating formation surfaces in cutting by Power roller Exc 8 tonne & n exc 12 tonne complete all as specified and as directed.
M&L Soling (or sub base) 200 mm thick with broken boulders or quarried stone, interstices filled, surface formed & rolled & consolidated to required gradient & camber complete all as specified and as directed.
M&L 150mm thick (in two layers of 7.5cm thick) (compacted thickness) WBM, with Granite trap or Basalt coarse aggregates of grading 2 (63 to 40mm size) or of grading 3 (50 to 20mm size), spread, rolled & consolidated to gradient materials & camber required complete all as specified and as directed.
Preparing unsurfaced water bound macadam surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc complete all as specified and as directed.
M&L applying evenly a priming/tack coat with paving bitumen VG-10grade @ 10 Kg per 10Sqm over WBM surface complete all as specified and as direcred.
M & L for bituminous premix carpet 30mm consolidated thickness with 0.405 cum of stone chipping mixed with 21.90kg of binder, rolled and compacted to required camber and gradient with 8-10tonne power roller using paving Bitumen VG-30 spreading of premix by manually complete all as speicified and as directed.
M&L for liquid seal coat, applying evenly binder VG-30 @ 9.8kg per 10 sqm binding with 6.3mm size stone chipping @ 0.09cum per 10sqm and rolled to a uniform smooth surface complete all as specified and as directed.
M & L for Continous fly ash brick edging; with width equal to the width of the brick; laid dry on end vertically complete all as specified and as directed.
E/M PORTION M & L for concealed point wiring for One light point controlled by one switch with 1.50 sqmm (nominal area), FRLS PVC insulated, unsheathed, single core multi-stranded copper conductor cable, 1100 volts grade,ISI marked controlled by one one-way switch, drawn through and including concealed medium grade PVC conduit not less than 25 mm dia, ISI marked, with all accessories including one run of 1.5 sqmm FRLS muti stranded copper conductor (Green colour cable) as earth continuity wire connected to common earth dolly, including sunk sheet steel terminal box made out of 1.20 mm thick and not less than 60 mm in depth GI/MS/ prssed steel terminal box to be conclead in wall, duly painted with two coates of anti corrosive black bituminous paint over a coat of red oxide primer in and out sides and two coated of aluminium paint on internal surface , including laminated hylum sheet cover, min 2.8 mm thick, ISI marked of Make" Hylem" for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer complete all as specified and directed. Note : (i)Wiring to be done as per arroved colour code in IE rule.Rate includes chase cutting for concealed wiring . (ii) Rate of circuit wiring from DB box to switchboard is encluded in unit rate of wiring.
All as per item No. 94 but for One Exhaust fan point controlled by one switch complete all as specified and directed.
All as per item No. 94 but for One 5 amps on independent board complete all as specified and directed.
All as per Item No. 94 here-in-before but with FRLS grade, (ISI mark) PVC insulated and unsheathed two run multistranded copper conductor of size 2.5 Sqmm for one power point of 3 pin 15 Amps on independent board including FRLS grade (ISI mark), PVC insulated, unsheathed one run multi-stranded copper conductor of size 2.5 sqmm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed.
All as per item No.97 here -in- before but wiring with 4.0 Sq mm FRLS mutistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 4.0 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed. .
S&F Polycarbonate switch piano, flush button, single pole, one way 5 Amp , 240 volts ISI marked, complete all as specified and directed.
S&F Switch socket combination 2 in 1, 5 Amps flush type complete all as specified and directed.
S&F Switch socket combined outlet 3 pin , 5A/16A , flush type complete all as specified and directed. .
S&F ceiling rose surface bakelite 65 mm dia three terminal complete complete all as specified and directed. .
S & F double door SPN DBs 4 way of powder coated DB's suitable for MCB's fitted with bus bar,Neutral link,Earth bar and Din rail complete complete all as specified and directed. .
S & F with MCB / Isolator SPN up to 40 amps 10 KA ,C-curve including connection with suitable size aluminium / copper lugs complete all as specified and directed.
S & F with MCB SP 240 volts up to 40 Amps, 10 KA breaking capacity, 'C' curve including connection with suitable size aluminium / copper lugs complete all as specified and directed .
S&F LED 18 Watt tube light fitting (T8 type) ,single end connection type including LED retrofit tube lamp 18 W , 240 Volt, PF > 0.90, colour Temp 6500 K, System Luminious efficacy > 100Lm/W, complete with powder coated CRCA decorative box type batten suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting complete all as specified & directed. Make : Bajaj Cat No. BLRB 18W CW LED (retrofit LED tube lamp 18 Watt, Single end connection) or equivelent in Crompton / Havells as approved by GE. Note : Make of batten and LED tube lamp should be of same make.
S & F LED bulk head light of 10 W with pressure die-cast housing along with polycarbonate diffuser and LED's IP-65 protection of watt, PF>0.95 complete all as specified and directed .
Supply and fixing lamp holder, PVC/Poly carbonate type with back plate suitable for batten fittings to be fixed on PVC box complete all as specified and directed
S & F heavy duty exhaust fans AC single phase 230/240 V of size 300 mm sweep (metal body) and 900 RPM with louvre including all work for making of suitable size of hole for Exhaust fan and grouting with nut , bolts & Fastenar on the wall and make good the disturbed surface and electric connection with 1.5 Sqmm three core PVC insulated round flexible copper conductor and sheathed cable complete all as specified and directed .
S & F single pole and neutral enclosure with two pin and earth, plug and socket , suitable for single phase 240 V,complete with one single pole MCB of capacity 20 amps having `C` charactristic, breaking cap 10 KA, including industial plug top, complete all as specified and as directed.
S&F LED bulb 10 watt, B-22 , 6500 K, 100 lumen complete all as specified and as directed.
M & L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cmx 6.3 mm thick buried directly in ground ( earth pit not less than 2.25 meter deep below ground level) with the top edge of the earth plate not less than 1.5 meter below normal ground level connected to galvanized earth lead wire 4mm dia by means of bolts, nuts, check nuts and washer of galvanized iron or of steel all as shown in electrical plate No.3 of MES SSR parts-I and including excavation & earth work in any type of soil , disposal of soil , providing alternate layers of charcoal and common salt, construction of PCC earth chamber in mix 1:3:6 type c-1 with 40 mm thick RCC 1:2:4 type B-J cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8 mm dia bar, watering arrangement with funnel and wiremesh and watering pipe of 20 mm dia GI light grade and 15 mm dia light grade pipe for earth lead protection and testing on completion, complete all as specified and directed.
Supply, install, testing and commissioning of indoor type, ONAN cooled, Oil immersed step down transformer of capacity 160 KVA , 11000/433 volts, copper wound, 3 Phase ,4 wire,50 HZ, as per EEL -2 , IS 1180 : 2014 with amendment No. 1, 2 & 3 , CRGO core type, Vector group DYN-11 , copper coil built up with 'F' class insulation completed with delta on HT side and star on LT side, with 7 position OFF circuit Tap changer ( tapping range + 7.5 % in step of 2.5% each, " OFF LOAD " tape changer including link arrangement and gear , with first filling of IS 335 ISI marked filtered and dehydrated transformer oil including standard fitting / fixtures undercarriage with plain rollers, lifting lugs etc, cable box at HT/LT side fitted with suitable size and rating copper extension links for fixing cables including cable glands and neutral brought on LT side, with Buchholz relay, WTI having contact for alarm and trip, oil temperature indicator, incluiding mounting the transformer on platform and connecting earthing strips complete all as specified and directed by Engr-in-Charge. Make : ABB / VOLTAMP/ Indian Transformer and electricals Pvt Ltd Gurgaon.
Note for Item No. 113 above (i) The contractor shall submit the test certificate from manufacturer (ii) The contractor shall submit QAP (Quality assurance programme) within 15 days after placement of order for transformer testing at factory. Transformer shall be dispatch only after inspection at manufacture premises to be done by MES Auth (Rep of acceptating officer) at manufacture permisses. (iii) The contractor shall furnish origional bill certificate (Purchase voucher and test certificate) of the transformer manufacturer. (iv) The contractor shall get the approval of GE for make of the transformer before placing the order. (v) Prior to manufacturing the general arrangement drawing design details of the transformer shall be get approved from GE. (vi) Connection of WTI to VCB through multi core copper conductor control cable of suitable size (irrespective of length) is deemed to be included in the item . (vii) LT side cable box to be provided with vertical terminal adoptor and extended links of copper strip of suitable size and rating of min 250 mm in length so as to connected 180 Sqmm x 3.5 core cable . (viii) Design and size of cable box to be get approved by GE before procurement of transformer. (ix) Contractor shall purchase transformer for OEM / authorised dealer of OEM. (x) The equipment shall be tested at site in presence of rep of accepting officer
Supply, install testing and commissioning totally enclosed single unit indoor VCB panel with incoming and outgoing facility comprising of vacuum circuit breaker indoor horizondal isolation and horizondal draw out type with integral earthing facility 11 KV 3 phase 50 Hz 400 Amps 250 MVA min 18.4 KA for 3 second complete with mechanical and electrical safety interlocking arrangement, breaker should have power frequency withstand voltage of minimum 28 KV and impulse withstrand voltage min 75 KV. The VCB should conform to IS 13118 and IEC 56 or equivalent standards with motor and spring charged closing mechanism. The VCB panel should have seperate self contained, insulated compartments for bus bars containing anodised copper bus bar of not less than 800 amps, CTs and cables. The panel shall be provided with the three Nos single phase cast resin type current transformer of ratio 110 /50/5-5A of suitable VA burden accuracy class 1 and potential transformer of 11 KV /v3/110/v3 V of 100 VA burden with fuses and mounted on withdrawable trolley complete all as specified and directed. Make : ABB/CROMPTON GREAVES / SCHIENDER
Note for item No. 114 above (i) Contractor shall purchase VCB from OEM or Authorised dealer of OEM . Purchase voucher and Test certificate from OEM shall be submitted by contractor before claiming the payment/ RAR (ii) The VCB shall be installed by service engineer from the company only including making necessary arrangement for connection of cable. The new HT XLPE cable shall be connected to VCB at locations as directed by Engr -in-Charge. (iii) Contractor shall make all arrangement on site for testing of tripping mechanisam / setting of relay functionality of VCB on short circut / earth fault / over voltage / over current etc. All testing equipments required for trip test shall be arranged by contractor. Tripping test of VCB on earth fault, over current and over voltage to be carried out by contracot before completion of work to the entire satisfaction of Rep of accepting officer. Same testing arrangement by bring primary injection kit to be done by the contractor at the time of precommisioning test of SEI. Cost of the same is deemed to be included in unit rate of item. All required calabration of relay to be done by contractor and in the contractor responsibility.. (iv) Contractor shall submit general arrangement of VCB and get approval of drawing and make of VCB before placing the order for procurement. (v) VCB to be bring on site after satisfactory testing of routine and other tests at factory (OEM) permisises. (vi) All arrangement and additional alteration required at site to installed the VCB and connect by providing with extendedcopper bus of approriate rating not less than 800 Amps with existing VCB panel shall be done by contractor without any extra cost. For this contractor shall visit the site before quoting the tender. (vii) AC power supply for relay in VCB to be provided by contactor. (viii) The equipment shall be tested at site in presence of rep of accepting officer
Supply, fixing, installation, commissioning and testing Servo controlled Voltage stablizer for automatic operation of 160 KVA capacity confiriming to BIS 9815: Part 1 : 1994 reaffirmed 2009, 3 Phase, 50 HZ, Naturally oil cooled, (ONAN Cooled) Indoor type, for automatic controlling and regulating voltage comprising Auto Transformer, Buck and Boost transformer,coppoer wound transformer, servo motor, unbalanced type, auto contolled solid state control circuit (suitable for DG set also) with digital display type, Relay free smooth and silent operation with 1st fill of tramsformer oil (IS 335:1993, reaffirmed 2005), IP 42 designed for input variation between 300 V to 480 V with output voltage stabilized at 415 V with accuracy ± 2.5% and speed of correction 8 Volts per second having following specification complete all as specified. (i) Input Voltage 300 Volt - 480 Volt. (ii) Output voltage stabilized at 415 V + 1% (Adjustable). (iii) Rated frequency 50 HZ. (iv) No distortion wave form. (v) Respond time shall not to exceed 10 Milisecond. (vi) Sensitivity (+ ) 1 %. (vii) Rate of correction 8 Voilt / Second for single Phase and 20 Volt / Second for Phase to Phase. (viii) No load losses less than 0.5% and full load losses less than 2.5%. (ix) Duty cycle Continuous 24 x7. (x) Efficiency more than 95%. (xi) Type of load : 3 Phase, unbalance type. (xii) Digital Volt meter / Ampere meter). Protection : (i) Overload/ Short circuit protection. (ii) High /Low voltage cut off. (iii) By pass arrangement in case of emergency. (iv) Single Phase Preventor. (v) and Phase sequence change protection.
Note for item No. 115 above : (i) The contractor shall submit the test certificate of voltage stabilizer from manufacturer (ii) The contractor shall furnish origional bill certificate (Purchase voucher and test certificate) of the manufacturer. (iii) The contractor shall get the approval of GE for make of the servo voltage stabilizer before placing the order. (iv) Prior to manufacturing the general arrangement drawing design details of the stabilizer shall be get approved from GE. (v) Contractor shall purchase voltage stabilizer for OEM / authorised dealer of OEM. (vi) The equipment shall be tested at site in presence of rep of accepting officer
Supply, laying, connecting and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, HT electric power cables (heavy duty) 11000 Volts grade (Earth Grade) with stranded aluminium conductor of size 95 Sqmm x 3 core complete all as specified and directed . Note : All the holes / opening made in wall to bring the cable in substation to be closed properly and make good of distrub surface to be done by contractor.
Supply and fixing cable jointing kit for 11 KV grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 Sqmm complete all as specified and directed.
Supply and fixing copper strip of size 20 x 3 mm as earth continuity conductor or main earthing lead fixed on "V" type porcelain insulator ( ceramic bus bar support insulator off white colour of suitable for mounting strip of 20 mm wide x 3 min thick) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. and joints to be connected by providing brass nut bolts and washer all as specified and directed . Note : (i) Insulator to be provided on every 50 cm length of copper strip. (ii) Item includs cost of brass nut bolts and procelain insulators and insulator fixing steel screw . No additional payment will be paid to the contractor on account of this.
Supply and fixing copper strip of size 32 x 6 mm as earth continuity conductor or main earthing lead fixed on "V" type porcelain insulator ( ceramic bus bar support insulator off white colour of suitable for mounting strip of 32 mm wide x 6 min thick) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. and joints to be connected by providing brass nut bolts and washer all as specified and directed . Note : (i) Insulator to be provided on every 50 cm length of copper strip. (ii) Item includs cost of brass nut bolts and procelain insulators and insulator fixing steel screw . No additional payment will be paid to the contractor on account of this.
S&F for Test point junction box made of polycarbonate without terminal block 130x130x77 mm IP 66 halogen free and weather proof including four hexagonal anticorrosive screws for out door installation complete all as specified and directed . Make : Hensel- Cat part No. KF 0600 H
S & F Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8 mm dia 25mm long hexagonal head screws complete all as specified and as directed.
M&L earthing complete with copper earth plate electrode 600 mm x 600 mm x 3 mm thick burried directly in ground (Earth pit not less than 4 mtr deep below ground level) with top edge of the plate not less than 3.25 mtr below ground level connected to copper strip 20 x 3 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation in hard dense soil / disintergate rock, filling charcoal and salt around the plate in layers , filling the pit with agriculture soil free from stones, to be bring from out side defence land and mixed with Bentonide (3 bags of 25 Kg each ), construction of inspection pit of brick work of size 600 x 600 x 600 mm with PCC copping of 1 :2: 4 , 12.5 mm aggregate A1 with MS sheet 3 mm plate cover on frame of angle iron of size 40 x 40 x 5 mm with , wire mess, funnel, test point, 40 mm dia GI protection pipe light grade and 32 mm GI peforated pipe for watering etc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed by Engr-in-charge (Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately.
Note item No. 122: (i) Contractor shall use Fresh agriculture soil , mixed with 3 x Bags of bentonide of 25 Kg each for refilling the pit to achive the desired resistance. (ii) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection. (iii) Necessary cost of repair to plinth protection and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints, bringing argiculture soil from out side defence land and cost of 3 x Bags of bentonide deemed to be included in the item rate. (iv) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work.
M & L Sand filling in-trenches with clean dry sand unwashed including gently pruning around cables complete all as specified. Note:-Punned thickness to be measured for payment.
Material and labour for fly ash brick laid flat in trenches over sand cushioning for cable protection complete all as specified and directed.
M&L for laying 80 mm bore GI pipe, light grade with all fittings, ISI mark, Conf to IS 1239 in crossing road/path and in pole up to junction box including necessary clamping etc. complete all as specified and as directed .
M&L for laying 50 mm bore GI pipe, light grade with all fittings, ISI mark, Conf to IS 1239 in crossing road/path and in pole/wall up to junction box including necessary clamping etc. complete all as specified and as directed .
M&L for laying 40 mm bore GI pipe, light grade with all fittings, ISI mark, Conf to IS 1239 in crossing road/path and in pole/wall up to junction box including necessary clamping etc. complete all as specified and as directed . Note: Union or long screw have to provided by contractor at tapping point/ at the place where pipe line connected/inserted as required at site and directed by Engineer in Charge.
Supply,installation,testing and commissioning 3 phase and neutral , 415 volts out door type , CPRI approved, factory made free standing , floor mounting ,dust and vermin proof, cubical type LT panel fabricated from 3.15 mm thick CRCA sheet for outer shell and 2.0 mm for inner shell, with angle iron frame of 50 x 50 x 6 mm , double door , front and back openable type, double door system, hinged opening , rubber lining,locking arrangement,with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade , protection class IP-54 fully compartmentalize design with 4 nos of bus bar made of copper of ETP grade suitable for 400 Amps ( Size of copper strip should not be less than 40 x 8 mm for each phase and neutral) pre-wired with suitable size of copper strip/ copper wire with colour code for connecting out going MCCB/ MCB`s, including suitable aluminium earth strips conforming to IS with danger notice plate , necessary cable glands , cable connection with proper lugs ,PCC foundation and pedestal for fixing piller feeder box / LT Panel with PCC 1:5:10 , 15 cm thick in foundation , brick (Fly ash) / PCC block work in CM 1:6 , rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting bolts etc for panel. The plateform shall be of 450 mm height above ground level all as specified with supply and fixing the following. (A) Incoming (i) MCCB 250 Amps rating, 4 pole ,415 V, AC, 50 HZ, thermal release range 200-250 Amp with adjustable overload setting and , short circuit setting, Ics-100 % Icu , service breaking capacity 36 KA --- 01 Nos with rotatary handle. Make L&T cat Part No. CM92109OOP1OG (ii) Digital Ammeter---01 Nos with Suitable CT and wiring. (iii) Digital Voltmeter - 01 No (iv) Three indication lamp (v) Neon type for three phase. (vi) Slector switch - 2 Nos
ITEM NO. 131 CONTD.. (B) Outgoing (i) MCCB 160 Amps rating, 4 pole ,415 V, AC, 50 HZ, thermal release range 125-160 Amp with adjustable overload setting and , short circuit setting, Ics-100 % Icu , service breaking capacity 36 KA - 01 Nos with rotatary handle. Make : L&T Cat Part No. CM92108OOM1OG (ii) MCCB 100 Amps rating, 4 pole ,415 V, AC, 50 HZ, thermal release range 80-100 Amp with adjustable overload setting and , short circuit setting, Ics-100 % Icu , service breaking capacity 25 KA - 02 Nos with rotatary handle. Make : L&T Cat Part No. CM91712OOKOOG (ii) MCB 40 Amp Four Pole (FP) , ultimate breaking capacity 10 KA , C curve - 02 No (iii) MCB 25 Amp Double Pole (DP) , ultimate breaking capacity 10KA , C curve - 02 No (iv) The equipment shall be tested at site in presence of rep of accepting officer
Supply,installation,testing and commissioning 3 phase and neutral , 415 volts Indoor type , CPRI approved, factory made free standing , floor mounting ,dust and vermin proof, cubical type LT panel fabricated from 2.0 mm thick CRCA sheet for with angle iron frame of 50 x 50 x 6 mm , front and back openable type, double door system, hinged opening , rubber lining ,locking arrangement,with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-9032 shade , protection class IP-43 fully compartmentalize design with 4 nos of bus bar made of copper of ETP grade suitable for 500 Amps ( Size of copper strip should not be less than 40 x 10 mm for each phase and neutral) pre-wired with suitable size of copper strip/ copper wire with colour code for connecting out going MCCB/ MCB`s, including suitable aluminium earth strips conforming to IS with danger notice plate , necessary cable glands , cable connection with proper lugs ,PCC foundation and pedestal for fixing piller feeder box / LT Panel with PCC 1:5:10 , 15 cm thick in foundation , brick (Fly ash) / PCC block work in CM 1:6 , rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting bolts etc for panel. The plateform shall be of 300 mm height above ground level all as specified with supply and fixing the following. (A) Incoming (i) MCCB 320 Amps rating, 4 pole ,415 V, AC, 50 HZ, thermal release range 250 -320 Amp with adjustable overload setting and , short circuit setting, Ics-100 % Icu , service breaking capacity 36 KA --- 01 Nos with rotatary handle Make L&T cat Part No. CM98403OOQOOG (ii) Digital Ammeter---01 Nos with Suitable CT and wiring. (iii) Digital Voltmeter - 01 No (iv) Three indication lamp (v) Neon type for three phase. (vi) Slector switch - 2 Nos
ITEM NO. 132 CONTD.. (B) Outgoing (i) MCCB 250 Amps rating, 4 pole ,415 V, AC, 50 HZ, thermal release range 250-320 Amp with adjustable overload setting and , short circuit setting, Ics-100 % Icu , service breaking capacity 36 KA - 01 Nos with rotatary handle. Make L&T cat Part No. CM92109OOP1OG (ii) MCCB 200 Amps rating, 4 pole ,415 V, AC, 50 HZ, thermal release range 160-200 Amp with adjustable overload setting and , short circuit setting, Ics-100 % Icu , service breaking capacity 36 KA - 01 Nos with rotatary handle. Make L&T cat Part No. CM92109OON1OG (i) MCCB 160 Amps rating, 4 pole ,415 V, AC, 50 HZ, thermal release range 125-160 Amp with adjustable overload setting and , short circuit setting, Ics-100 % Icu , service breaking capacity 36 KA - 01 Nos with rotatary handle. Make L&T cat Part No. CM92108OOM1OG (ii) MCCB 100 Amps rating, 4 pole ,415 V, AC, 50 HZ, thermal release range 80-100 Amp with adjustable overload setting and , short circuit setting, Ics-100 % Icu , service breaking capacity 25 KA - 01 Nos with rotatary handle. Make : L&T cat Part No. CM91712OOKOOG (ii) MCB 40 Amp Four Pole (FP) , ultimate breaking capacity 10 KA , C curve - 01 No (iii) MCB 25 Amp Double Pole (DP) , ultimate breaking capacity 10KA , C curve - 01 No
ITEM NO. 132 CONTD.. Note:- (i) All MCCB/MCB should be of Make : L&T/ABB/Schnider. (ii) Drawing of LT panel and make of items shall be get approved from GE before ordering the panel. (iii) Cost of lugs for cable and cable gland etc also included in unit rate of panel. (iv) Cost included taking out existing cable from old panel and refixing and connecting to new panel. (v) Rotary handle to be provided for all MCCB for control and operation of MCCB. (vi) The copper extesion link from bus bar to out going MCCB / MCB`s shall not be less than 1.5 times the rated current of individual out going feeders. (vii) The equipment shall be tested at site in presence of rep of accepting officer
Supply of Rubber mat of 1 meter x 2 meter x 19 mm, Conf to IS and complete all as specified and directed.
S&F Auto transfer switch in sheet steel enclosure of 160 Amp, 415 Volt, 3 Phase, 50 HZ , Frame 2, with advance feature of priority source slection, suitable for 3 Phase and 1 Phase source, ajustable time delay, with terminal shrouds, Phase barriers and source seperator, including connecting the cables in ATS complete all as specified and directed . Make L&T , Cat Part No. CK90162BSOO or equivalent in Havells Note : The equipment shall be tested at site in presence of rep of accepting officer
S& F cable route marker made up of cast iron (Round Dia ) of 100 mm round plate, 3 mm thick fixed on MS angle iron of size 25 x 25 x 5 mm, 800 height fixed in ground over the cable route with PCC 1:2:4 complete all as specified and directed .
M&L for boring of road for laying 80/100 mm dia GI pipe medium grade complete all as specified and as directed .
M & L for fabrication of display board for earth pit nos, lacation and periodical test results for power circuit earthing, machinary earthing ,lightening conductor earthing, made of MS sheet 3.0 mm thick sheet, rectangular welding on angle iron of 25 x 25 x 4 mm of 600 mm height from ground level 30 cm including fixing in PCC 1:2:4 with 20 cm X 20 cm X 20 cm (below ground level) grade aggregate foundation to be carried out at different location technical area/domestic area . Dimention of board shall be 30 cm X 25 cm. or any other dimention not more than 0.075 sq mtr of MS Board The instruction shall be written black painted board in white letters not less than 2 " size for all type of boards complete all as specified and as directed .
M&L for PCC (1:3:6), type C-2 (using 40 mm graded stone aggregate) for foundation for pole mass concrete etc complete all as specified and as directed .
M&L for PCC (1:2:4), type B-1 (using 20 mm graded stone aggregate) for foundation for pole mass concrete etc complete all as specified and directed. (For Making PCC block for grounting/ holding GI pipe fixed / errect on tarce of bldg for mounting LA and other allied works) complete all as specified and as directed .
Supply and fixing stainless steel wire rope of minimum thickness 3 mm PVC coated for holding GI pipe of 40 mm dia to stand alone, straight vertical mounted with lightening arrester complete all specified and directed .
Supply and fixing stainless steel wire rope clamp grip for rope clamping 'U' with nut bolts washer etc all as specified and directed .
S & F Brass Copper lightening arrester 9.2 mm diameter and 915 mm in length with 5 spikes and base plate 8.5 x 8.5 cm for building protection coverage of 45 degress from the top point 1.85 m all as specified and directed by Engineer in Charge.complete all as specified and as directed .
Supply and Laying XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 10 sqmm x 2 core, laid in trenches/floor or fixed on wall/pole including providing aluminium cable lugs at end terminals complete all as specified and directed .
M&L for earthing complete with galvanised steel earth plate electrode size 600 x 600 x 6 mm thick, burried directly in ground, (Earth pit not less than 3.25 m deep below ground level) with top edge of the plate not less than 2.5 m below ground level connected to galvanised iron strip 32 x 6 mm as earthin lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion, surrounded from all sides by mixture of charcoal and common salt and electrode by means of steel and GI pipe light grade 20 mm dia bore for watering , funnel with wire mesh, construction of inspection pit of brick work of size 600 x 600 x 600 mm with PCC copping of 1 :2: 4 , 12.5 mm aggregate A1 with MS sheet 3 mm plate cover on frame of angle iron of size 40 x 40 x 5 mm complete all as specified and directed . NOTE:- 1. The unit rate includes for protection GI pipe of 40 mm and watering pipe of 20 mm bore including excavation for earth pit in any type of soil/ disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to achieve desired result as the soil resistiviy is very high. 3.The cost of GI strip of size 32 x 6 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and GI strip beyond 7.5 RM will be measured seperately. 4. All the joints in GI strip and connection with Earth Plate to be welded and in addition by providing double brass nut bolt and washer. 5. Cost of welding and nut bolts are deemed to be included in the unit rate.
Material and labour for laying of GI tube medium grade 25 mm bore ISI marked, Conf to IS 1239 with all fittings as required at site and laid in trenches incl connecting complete all as specified and directed . Note : Union or long screw have to provided by contractor at tapping point/ at the place where pipe line connected/inserted as required at site and directed by Engineer in Charge.
Material and labour for fixing of GI tube medium grade 20 mm bore ISI marked, Conf to IS 1239 with all fittings as required at site and fixed to walls and ceiling or laid in floor incl connecting complete all as specified and directed . Note Union or long screw have to provided by contractor at tapping point / at the place where pipe line connected/inserted as required at site and directed by Engineer in Charge.
Material and labour for fixing GM globe/gate valve 40 mm bore with iron wheel head, screwed both ends for iron/PPR pipes, ISI marked, conf to IS , heavy class including complete all as specified and directed . Note: Union or long screw have to provided before fixing of gate valve. Make: Zoloto/ Leader
Material and labour for fixing GM globe/gate valve 20 mm bore with iron wheel head, screwed both ends for iron/PPR pipes, ISI marked, conf to IS , heavy class including complete all as specified and directed . Note: Union or long screw have to provided before fixing of gate valve. Make: Zoloto/ Leader
M&L for cutting CI/ GI pipe for insertion of new branch / Tee etc in 100 mm bore pipe for new connection including clamps etc complete all as specified and directed.
Material and labour for fixing of CI special (Bends any type, radius an angle Tapers any type, straight, bend, increasing, decreasing or double socket etc. Tee pieces single branch, `Y' junction, double branch, cross all end flanged or all sockets or socket and spigot collars, caps and plugs complete as per site requirement up to 150 mm dia all as specified and directed .
M&L for Construction of brick massonry valve pit chamber of inner dimension 800 x 800 x 800 mm suitable for sluice valves upto 100 mm size, with PCC 1:4:8 type D-2 for foundation, brick work in cm 1:6 rendering 1:4, 15 mm plastering, coping in PCC 1:2:4 type B-1, incl necessary earth work, including MS sheet cover of thickness 3.00 mm on 40 x 40 x 6.0 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement complete all as specified and directed.
Supply, Laying, connecting and testing cable XLPE insulated, screened PVC bedded , galvanized steel strip or wire armoured,electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 150 sqmm x 3.5 core, including provide bimetallic lugs at end terminals complete all as specified and directed . NOTE:-(i) All the holes/opening made in wall to bring the cable in substation to be closed properly and make good of disturb surface to be done by contractor. (ii) Manual excavation to be done. During excavation if any damage occurred to existing cable any type/water pipe line, it will be contractor's responsibility to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service cannot be effected due to such damage . If contractor fails to repair it within 24 hrs penalty@ Rs 500 will be charged to contractor . In this GE decision will be final
STAR ENTERPRISES
SRI HARSHITA ELECTRICALS
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .