Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.7 LAccepted-Finance 216 UGF RAM VIHAR ANAND VIHAR DELHI 110092 | SHAHDARA | DELHI | 110092 | L1 | Accepted-Finance Being lowest | |
| 2 | L2₹28.1 L+₹42,673 (1.54%)Accepted-Finance | L2 | Accepted-Finance Not being lowest | |
| 3 | L3₹30.4 L+₹2.7 L (9.60%)Accepted-Finance | L3 | Accepted-Finance Not being lowest | |
| 4 | L4₹33.2 L+₹5.5 L (19.9%)Accepted-Finance PLOT NO 10 9 OM VIHAR PHASE 1 A UTTAM NAGAR NEW DELHI 110059 | WEST DELHI | DELHI | 110059 | L4 | Accepted-Finance Not being lowest | |
| 5 | L5₹34.7 L+₹7.0 L (25.2%)Accepted-Finance RZ D 29A GALI NO 05 SYNDICATE ENCLAVE NEAR DABRI MORE NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L5 | Accepted-Finance Not being lowest |
| Sl No | Description | Qty | Unit | a.k constructions L9 | M/S ANIL KUMAR L7 | V M CONSTRUCTION L1 | imran construction company L8 | M/S VERMA BUILDER L3 | SHREE RAM BUILD TECH L5 | M/S MANINDER CONSTRUCTION CO. L6 | Lamba Enterprises L4 | M/S Sunil Steel Works L10 | DEEP BUILDER L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for chipping out spilled and loose concrete cover and derusting steel reinforement of concrete column, beam, slab, chajjas, parapets and the like as directed upto 25 to 35mm thick roughening and cleaning concrete surface with steel wire brushes, washed with water and allowed to dry including derusting steel wire reinforecement, providing fabric MS wire mesh 75 x 75 x 2mm as reinforcement to concrete surface applying adhesive/admixture over steel mesh and providing 25mm average thickness guiniting mix using one part of OPC 53 grade and two part of gaggar sand mixed with adhesive/admixture @ pressure of 2.5 to 3.00kg/Sqcm by guiniting machine and surface finished even and fair including necessary padding, shuttering/scaffolding, formwork (guniting work to be carried out upto 10 metre height) complete as directed at site.
Note :- (a) After placing the additional reinforecement all concrete surfaces shall be throughly scrubbed with wire brushes, washed with water and allow to dry, apply chemistic polycretes admixture @ 2.25 kg by weight of cement all as per manufacturers instruction.
(b) when polymix concreting in taking condition, guiniting is done with polycrete admixture @ 2% by weight of cement all as per manufacturers instructions (polycrete admixture shall be procured from chemical adhesive Pvt Ltd Co or their authorised dealer).
(c) Cost of the above aspect shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account.
Note rate quoted up to G+8 bldg including scaffolding | 60 | Sqm | 400 ₹24,000 | 299 ₹17,940 Lowest | 1,200 ₹72,000 | 500 ₹30,000 | 1,500 ₹90,000 | 800 ₹48,000 | 700 ₹42,000 | 1,451 ₹87,060 | 900 ₹54,000 | 360 ₹21,600 |
| 2.00 | Taking down rain water pipes (CI, AC, PVC etc) set in any cement mortor of any diameter incl bends Note rate quoted up to G+8 bldg including scaffolding. | 820 | RM | 10 ₹8,200 | 1.99 ₹1,631.8 Lowest | 12 ₹9,840 | 20 ₹16,400 | 50 ₹41,000 | 10 ₹8,200 | 10 ₹8,200 | 5 ₹4,100 | 10 ₹8,200 | 5 ₹4,100 |
| 3.00 | S/F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 110mm bore complete. Note rate quoted up to G+8 bldg including scaffolding. | 400 | RM | 190 ₹76,000 | 199 ₹79,600 | 160 ₹64,000 | 300 ₹1,20,000 | 300 ₹1,20,000 | 185 ₹74,000 | 300 ₹1,20,000 | 175 ₹70,000 | 165 ₹66,000 | 100 ₹40,000 Lowest |
| 4.00 | S/F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 75 mm bore complete. Note rate quoted up to G+8 bldg including scaffolding. | 400 | RM | 140 ₹56,000 | 199 ₹79,600 | 150 ₹60,000 | 250 ₹1,00,000 | 250 ₹1,00,000 | 120 ₹48,000 | 200 ₹80,000 | 185 ₹74,000 | 155 ₹62,000 | 100 ₹40,000 Lowest |
| 5.00 | S & F 100 mm bore cast iron (sand cast) soil, waste, vent pipe in any length with or without ears with cement joint fixed to walls, complete all as specified & directed. Note rate quoted up to G+8 bldg including scaffolding. | 10 | RM | 150 ₹1,500 Lowest | 799 ₹7,990 | 900 ₹9,000 | 900 ₹9,000 | 800 ₹8,000 | 800 ₹8,000 | 300 ₹3,000 | 450 ₹4,500 | 600 ₹6,000 | 200 ₹2,000 |
| 6.00 | S & F 75 mm bore cast iron (sand cast) soil, waste, vent pipe in any length with or without ears with cement joint fixed to walls, complete all as specified & directed. Note rate quoted up to G+8 bldg including scaffolding. | 10 | RM | 100 ₹1,000 Lowest | 799 ₹7,990 | 850 ₹8,500 | 700 ₹7,000 | 700 ₹7,000 | 750 ₹7,500 | 300 ₹3,000 | 450 ₹4,500 | 500 ₹5,000 | 200 ₹2,000 |
| 7.00 | S&F in repairs PVC (SWR) bends of any radius ( 110mm bore) including jointing with solvent cement complete all as specified. | 10 | Each | 60 ₹600 | 169 ₹1,690 | 110 ₹1,100 | 350 ₹3,500 | 150 ₹1,500 | 140 ₹1,400 | 800 ₹8,000 | 120 ₹1,200 | 70 ₹700 | 50 ₹500 Lowest |
| 8.00 | S&F in repairs PVC (SWR) bends of any radius ( 75mm bore) including jointing with solvent cement complete all as specified. | 10 | Each | 45 ₹450 Lowest | 169 ₹1,690 | 100 ₹1,000 | 300 ₹3,000 | 120 ₹1,200 | 135 ₹1,350 | 800 ₹8,000 | 120 ₹1,200 | 60 ₹600 | 50 ₹500 |
| 9.00 | S&F in repairs PVC (SWR) vent cowl of 110 mm bore. | 10 | Each | 90 ₹900 | 109 ₹1,090 | 105 ₹1,050 | 350 ₹3,500 | 400 ₹4,000 | 110 ₹1,100 | 100 ₹1,000 | 120 ₹1,200 | 100 ₹1,000 | 50 ₹500 Lowest |
| 10.00 | S & F in repair 1000 ltr capacity three layer white colour rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including dismantling old water tank all as specified in SSR Part I I. | 5 | Each | 7,000 ₹35,000 | 5,999 ₹29,995 | 6,000 ₹30,000 | 6,500 ₹32,500 | 9,000 ₹45,000 | 6,200 ₹31,000 | 8,000 ₹40,000 | 5,400 ₹27,000 | 5,500 ₹27,500 | 2,500 ₹12,500 Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
13 Aug 2026, 6:00 pmClosed
LT COL MANISH E WASNIK
GE (CENTRAL) DELHI CANTT-10
8826/TOKEN-47/2026-27
2026_MES_779091_1
GE/TOKEN-47/2026-27
Open Tender
Civil Works
Item Rate
180 days
GE (CENTRAL) DELHI CANTT-10
AS PER NIT
9 documents required · 9 mandatory
₹500
Yes
GE (CENTRAL) DELHI CANTT-10
₹80,000
Yes
21 Aug 2026
16 Jul 2026
15 Aug 2026
16 Jul 2026
13 Aug 2026
30 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for chipping out spilled and loose concrete cover and derusting steel reinforement of concrete column, beam, slab, chajjas, parapets and the like as directed upto 25 to 35mm thick roughening and cleaning concrete surface with steel wire brushes, washed with water and allowed to dry including derusting steel wire reinforecement, providing fabric MS wire mesh 75 x 75 x 2mm as reinforcement to concrete surface applying adhesive/admixture over steel mesh and providing 25mm average thickness guiniting mix using one part of OPC 53 grade and two part of gaggar sand mixed with adhesive/admixture @ pressure of 2.5 to 3.00kg/Sqcm by guiniting machine and surface finished even and fair including necessary padding, shuttering/scaffolding, formwork (guniting work to be carried out upto 10 metre height) complete as directed at site.
Note :- (a) After placing the additional reinforecement all concrete surfaces shall be throughly scrubbed with wire brushes, washed with water and allow to dry, apply chemistic polycretes admixture @ 2.25 kg by weight of cement all as per manufacturers instruction.
(b) when polymix concreting in taking condition, guiniting is done with polycrete admixture @ 2% by weight of cement all as per manufacturers instructions (polycrete admixture shall be procured from chemical adhesive Pvt Ltd Co or their authorised dealer).
(c) Cost of the above aspect shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account.
Note rate quoted up to G+8 bldg including scaffolding | 60 | Sqm | - | - |
| 2 | Taking down rain water pipes (CI, AC, PVC etc) set in any cement mortor of any diameter incl bends Note rate quoted up to G+8 bldg including scaffolding. | 820 | RM | - | - |
| 3 | S/F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 110mm bore complete. Note rate quoted up to G+8 bldg including scaffolding. | 400 | RM | - | - |
| 4 | S/F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 75 mm bore complete. Note rate quoted up to G+8 bldg including scaffolding. | 400 | RM | - | - |
| 5 | S & F 100 mm bore cast iron (sand cast) soil, waste, vent pipe in any length with or without ears with cement joint fixed to walls, complete all as specified & directed. Note rate quoted up to G+8 bldg including scaffolding. | 10 | RM | - | - |
| 6 | S & F 75 mm bore cast iron (sand cast) soil, waste, vent pipe in any length with or without ears with cement joint fixed to walls, complete all as specified & directed. Note rate quoted up to G+8 bldg including scaffolding. | 10 | RM | - | - |
| 7 | S&F in repairs PVC (SWR) bends of any radius ( 110mm bore) including jointing with solvent cement complete all as specified. | 10 | Each | - | - |
| 8 | S&F in repairs PVC (SWR) bends of any radius ( 75mm bore) including jointing with solvent cement complete all as specified. | 10 | Each | - | - |
| 9 | S&F in repairs PVC (SWR) vent cowl of 110 mm bore. | 10 | Each | - | - |
| 10 | S & F in repair 1000 ltr capacity three layer white colour rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including dismantling old water tank all as specified in SSR Part I I. | 5 | Each | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
BOQ_872619.xls
BOQ • 0.31 MB
tenderpage.pdf
Tender Documents • 0.98 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .