Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical 01 PREMPURA MAHESHWAR DISTRICT KHARGONE MADHYA PRADESH | Accepted-Technical Qualified |
Tender Value
₹4.3 L
EMD Value
₹8,606
Closing Date
10 Mar 2026, 5:30 pmClosed
Executive Engineer PHED Dewas
Executive Engineer PHED Dewas
Water Supply works at Jawahar Navoday Vidhyalay Chandrakeshar Dam Kantafoad District Dewas including cost of all material and labour complete with testing of all work
2026_PHED_484909_1
46/2025-26
Open Tender
Civil Works - Water Works
Percentage
30 days
DEWAS
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
₹8,606
Yes
24 Mar 2026
24 Feb 2026
12 Mar 2026
24 Feb 2026
10 Mar 2026
24 Feb 2026
Water Supply works at Navoday Vidhyalay Chandra keshar Dam Kantafoad District Dewas including cost of all material and labour complete with testing of all work
Supplying & Installation of Five star BEE rating ISI Marked required capacity of Three phase, 50 Hz, 415V, Open well Submersible pump, with Control Panel Starter with Dry Run Protection, single phase preventer, connections, etc. as required as per specifications but excluding pipe and connection cable..10 HP Head Mt. 147-64 Discharge LPM 60-270 PHE USOR I.No.11.3.8 /P.No. 165
Providing laying and jointing of following galvanized Iron (MS) Pipes with specials (such as bends, elbows, tees etc) class light, medium & heavy including testing of joints, cost of pipes, specials and jointing materials all complete.Pipes and sockets conforming to IS-1239/2011 Part II. 50 mm dia (Rate = 463-32 = 431) PHE USOR I.No. 3.1.6 - 3.2.6 /P.No. 47-48
Providing, laying, Jointing & field testing of PE pipes made from 100% virgin material (Earlier know as hight Density Polyethylene pipes, PE 100) conforming to IS 4984/ 14151/ 12786/ 13488 with necessary jointing material like mechanical connector or jointing pipes by heating the ends of pipes with the help of Teflon coated electric mirror/ heater to the required temperature and then mechanically pressing the ends together against each other, to form a monolithic & leak proof joint by thermosetting process. It may be required to be done with Jacks/ Hydraulic Jacks/ But fusion machine. (50mm & above fusion jointed & below 50mm mechanical jointed) 90 mm dia PE100 PN 10 PHE USOR I.No. 2.1.5 /P.No. 32
Dismantling of Cement Concrete Pavement by mechanical means using pneumatic tools i.e. concrete cutter and concrete braker cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately. (use of cement concrete cutter before breaking the concrete road is mandatory for this item). PHE USOR I.No. 15.19/P.No. 259
Earth work in excavation for foundation, trenches for pipes/ cables, drains or in well excavation etc. by mechanical means/ manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. Ordinary rock or soft rock with or without blasting PHE USOR 15.6.3 /P.No. 257
Earth work in excavation for foundation, trenches for pipes/ cables, drains or in well excavation etc. by mechanical means/ manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. All kinds of soil. PHE USOR I.No. 15.6.1/P.No. 257
Filling available excavated earth in trenches, lead up to 50m and lift upto 1.5m in all kind of soil excluding watering and ramming. PHE USOR I.No. 15.12/P.No. 258
Providing butt fusion welded joint/ jointing by heating to the ends with the help of Teflon coated electric mirror/heater ends together etc . by thermosetting process to PE-100 pipe and specials. (6kg, 8kg, 10kg)(50mm & above fusion jointed & below 50mm mechanical jointed) including 90 mm dia PHE USOR I.No. 2.7.3 /P.No. 34
Providing & fixing of following Cast iron double flanged sluice valves as per I.S.:14846-2000 fitted with cast iron cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete. 80 mm dia PN 1.6 PHE USOR I.No. 8.62.3 /P.No. 136
Providing & fixing following cast iron double flanged single door reflux (non return) valves including jointing & testing with cost of jointing material such as bolts, nuts and rubber insertion all complete as per IS :5312 (Part I) 80 mm dia PHE USOR I.No. 8.65(a).3 /P.No. 139
Providing & fixing following cast iron single acting air valves, large orifice with screwed end as per IS : 14845-2000 including jointing & testing with cost of jointing material and rubber insertion all complete as per PN- 1.0 25 mm dia PHE USOR I.No. 8.71.1 /P.No. 142
Construction of Brick masonry valve chamber with 20 cm thick wall in 1:6 C.M. with 12mm thick 1:4 Cement Plaster and base course 10 cm. thick in M- 15. Inside Dimensions 110x80x100cm M-20 RCC chamber cover size 130x120cmx10cm including cost of materials, labour, finished with floating coat of neat cement etc. complete. PHE USOR I.No. 15.66 /P.No. 265
Providing, Supplying and fixing of Electro Fusion Fittings in accordance with BS EN 12201: Part-3 suitable for drinking water with in black/blue colour manufactured from compounded PE80/ PE100 virgin polymer and compatible with PE80/PE100 pipes, in pressure rated SDR11 with min PN 12.5 rated for water application. The cost such as testing, inspection charges, transportation up to site, transit insurance, loading, unloading, stacking etc. all complete. Electro Fusion Coupler 90 mm PHE USOR I.No. 2.14.1.8 /P.No. 39
Providing, Supplying and fixing of Electro Fusion Fittings in accordance with BS EN 12201: Part-3 suitable for drinking water with in black/blue colour manufactured from compounded PE80/ PE100 virgin polymer and compatible with PE80/PE100 pipes, in pressure rated SDR11 with min PN 12.5 rated for water application. The cost such as testing, inspection charges, transportation up to site, transit insurance, loading, unloading, stacking etc. all complete. Electro Fusion Equal Tee 90 mm PHE USOR 2.14.2.8 /P.No. 40
Providing, Supplying and fixing of Electro Fusion Fittings in accordance with BS EN 12201: Part-3 suitable for drinking water with in black/ blue colour manufactured from compounded PE80/ PE100 virgin polymer and compatible with PE80/PE100 pipes, in pressure rated SDR11 with min PN 12.5 rated for water application. The cost such as testing, inspection charges, transportation up to site, transit insurance, loading, unloading, stacking etc. all complete. Electro Fusion Elbow 90 mm PHE USOR I.No. 2.14.3.8 /P.No. 40
Providing, Supplying and fixing of Electro Fusion Fittings in accordance with BS EN 12201: Part-3 suitable for drinking water with in black/ blue colour manufactured from compounded PE80/ PE100 virgin polymer and compatible with PE80/PE100 pipes, in pressure rated SDR11 with min PN 12.5 rated for water application. The cost such as testing, inspection charges, transportation up to site, transit insurance, loading, unloading, stacking etc. all complete. Electro Fusion End Cap 90 mm PHE USOR I.No.2.14.5.8 /P.No. 41
Providing, Supplying and fixing of Electro Fusion Fittings in accordance with BS EN 12201: Part-3 suitable for drinking water with in black /blue colour manufactured from compounded PE80/ PE100 virgin polymer and compatible with PE80/PE100 pipes, in pressure rated SDR11 with min PN 12.5 rated for water application. The cost such as testing, inspection charges, transportation up to site, transit insurance, loading, unloading, stacking etc. all complete. Spigot Long Neck pipe End (stub end ) for electrofusion joint 90 mm PHE USOR I.No. 2.14.6.3 /P.No. 41
Providing, Supplying and fixing of Electro Fusion Fittings in accordance with BS EN 12201: Part-3 suitable for drinking water with in black/ blue colour manufactured from compounded PE80/PE100 virgin polymer and compatible with PE80/PE100 pipes, in pressure rated SDR11 with min PN 12.5 rated for water application. The cost such as testing, inspection charges, transportation up to site, transit insurance, loading, unloading, stacking etc. all complete. Spigot Long Neck pipe End (stub end ) for electrofusion joint 110 mm PHE USOR I.No. 2.14.6.4 /P.No. 41
Provision for Jointing of TW to Rising Main with cost of Material/ specials such as GI Union / CI Flange, GI Reducer UPVC MTA FTA etc. as per requirement of site i/c cost of labour etc. complete as per approved specification and as directed by Engineer in charge. PHE USOR I.No. 14.22/P.No. 240
Providing and laying mechanically mixed cement concrete with crushed stone aggregate excluding centering and shuttering (with 40mm nominal size graded stone aggregate). 1:3:6 (M-10) PHE USOR I.No. 15.30.1.3 /P.No. 260
Providing and laying mechanically mixed cement concrete with crushed stone aggregate excluding centering and shuttering (with 40mm nominal size graded stone aggregate). 1:2:4 (M-15) PHE USOR I.No. 15.30.1.4 /P.No. 260
Supply & erection of readymade mini pump house (control panel box) GI sheet of 18 gauge of size 90cmx90cm x60cm with 40x40x5mm angle Iron frame to fix it 200mm below ground level with hold fasts grouted in PHE USOR I.No. 14.21 /P.No. 239
L.T. Line 3 PHASE 5 WIRE ON PCC 8M LONG USING 1100 Volts Grade A.B. Cable 3 X 25+1*16+1*35 Sq.mm XLPE with maximum span of 50 meters including all labour charge complete Schedule Ref.D-2.1of MPPKVVCL SOR 2022-23
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 5.30 MB
46JawaharNavodayVidhyalayNIT.pdf
Tender Documents • 5.29 MB
BOQ_570041.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .