Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.6 LAccepted-AOC M MAHESH | ₹24.6 L | L1 | Accepted-AOC Awarded |
| 2 | L2₹25.7 L+₹1.1 L (4.39%)Rejected-AOC CHENNAI | CHENNAI | CHENNAI | TAMIL NADU | ₹25.7 L+₹1.1 L (4.39%) | L2 | Rejected-AOC not Awarded |
Tender Value
₹24.0 L
EMD Value
₹24,100
Closing Date
23 Jan 2026, 3:00 pmClosed
ZONE OFFICE-3
NO.1, THATTANKULAM ROAD, MADHAVARAM, CHENNAI-60
Fabricating Supplying and installation of Puf Sheet for waiting Area of Madhavaram ERI at Kamarajar Salari in DN-27, Unit-7, Zone-3
2026_CoC_641111_1
Z.O.III.C.NO.E1/8986-A/2025
Limited
Civil Works
Works
120 days
CHENNAI
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹24,100
24 Jun 2026
9 Jan 2026
24 Jan 2026
9 Jan 2026
23 Jan 2026
9 Jan 2026
Installation of Vertical Bored cast in situ RCC piles of following diameter in all types of soils, using Standardised Concrete Mix of following grade, with sulphate resistant Cement or OPC/PPC, etc and Crushed Stone Sand and 20mm and down graded HBGS jelly coarse aggregate. The rate includes cost for placing of reinforcement cage in bore hole in correct position, cost of boring to the required depth with Bentonite solution with temprory casing of required length, conveyance of RMC to site and pouring concrete using Tremine pipes, conveyance of all materials to the site including all tools and plants, shifting the plants and equipments from one point to another, excavtion of mud pits for circulation of Bentonite soultion, closing the mud pits to original level and mud removal with initial lead and lift but including dismantling the concrete above the cut off level etc complete as directed by the departmental officers including socketing. The reinforcement cage should be welded properly for lifting. The concrete cubes to be tested as per IS 456- 2000. Acceptance criteria by clause 16.1. Frequency of testing as per 15.2.2. Testing to be conducted at both the ends at site as well as RMC plant. Pile driving depth should be decided by the departmental officers at site. The length of pile for payment shall be measured from top of shoe to the bottom of the pile cap.( Cost of Reinforcement provided for Pile and Welding charges shall be measured and Paid separately ) Grade of Concrete: M25 450 mm dia pile
Earth work excavation for foundation by Mechanical means for Isolated & Combined Footing etc in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the departmental officers.- Upto 2.40m Footing Depth. (including Refilling charges)
Galvalume Colour Sheet of size 0.47mm
3 layer PVC Readymade Underground water tank of 1000 litres capacity
Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works. - Internal water supply above ground level. For laying PVC pipes of dia 25mm
Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works. - Internal water supply above ground level. For laying PVC pipes of dia 20mm
Providing and laying, spreading and compacting graded stone aggregates to Wet Mix Macadam 250 mm thick specification including premixing the materials with water at OMC in mechnanical mix plant carriage of mixed material by tipper to site laying in uniform layers with pavers in Sub Base/ Base course on well prepared surface and compacting with vibratory roller to acheive the desired density including cost of material, labour charges, rentals for machinery, fuel and all other incidental charges etc., complete as per clause 406 of MORTH Rev-5
Supplying And Fixing Rubber Moulded Interlocking Blocks Against Available Edge Restraints 80 mm Thick of Approved Design And Pattern of Strength 40 N/Sq.m. 10 mm Iss Metal With Minimum Cement Content As Applicable To M 40 Grade Concrete As Per Is-456-2000 Manufactures By Mechanical Or Hydraulic Machine Using Vibro-Compaction Process And Laid Over 50 mm Thick Laying Course (Bedding) Crushed Stone Sand (M Sand) Well Compacted By Plate Compactor With A Joint Width of 2 mm To 5 mm Including Filling of All Joints With Crushed Stone Sand (M Sand) And Compacting The Paved Surface With Plate Compactor Two Or Three Times Until All The Unit-To-Unit Joints Are Completely Filled With Crushed Stone Sand (M Sand) And Trimming The Edges Neatly Including All Labour Charges And Plate Compactor Charges Etc. Complete(Cost Inclusive of Crushed Stone Sand (M Sand)).
Wiring with 2 x 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A FT switch with continuous earth wire connection of 1.5 sq.mm copper wire for making good of the concealed portion with suitable colour for PVC concealed light point / fan point (for electronic regulator)
Cost of supply of 20w 4 feet LED fitting with LED tube complete set (Patty and LED tube)
Supply and fixing of WT bulk head fitting with guard suitable with 7W / 9W LED bulb
Supply and fixing of 1200mm (48") AC ceiling fan complete with stepped electronic 300W regulator with 1 meter down rod on the existing clamp
I.SI.MARKED 31/2X70 SQ.MM CABLE
HDPE pipe of size 90 mmOD x 76mm ID
Laying of cable along road / street through 50mm OD, HDPE pipe (trench size 45cm width x 75 cm depth)
Supplying, erecting and Fixing precast reinforcement bench with back rest. Bench shall consist of 2 nos. L shaped bases support in natural cement color of thickness 100mm, back height 1000mm, front height 450mm, base width 620mm and 5Nos Reinforced Concrete planks in red color and size of 1500x100x50mm and 1no. reinforced concrete plank of 150x200x50mm: manufactured by using M-30 grade concrete & reinforced suitably: all parts to be joined with galvanized nuts and bolts of suitable size.
Providing and Fixing of polyurethane foam as External Wall Thermal insulation panels or Sandwich insulated panels with external 0.50mm total coated thickness pre painted galvalume sheet with micro ribbed profile, whereas internal 0.50mm total coated thickness pre painted galvanized iron sheet with micro ribbed profile and the insulation material will be chlorofluoro carbon and hydro chlorofluoro carbon free, high performance rigid polyurethane foam (PUF) conforming to IS 12436 having density not less than 40±2Kg/M3, Thermal conductivity (K-Value) 0.024 W/m.K measured at 10 degree C mean temperature along with necessary flashings such as L flashing, C flashing etc& accessories such as screws, fastners, sealants etc for fixing the panel etc., complete complying with standard specification. - 150mm thick PUF external wall panel
Supplying and filling in foundation, basement, etc with filling crushed stone dust (Quarry dust) in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Supplying, fabricating and placing in position Ribbed Tor Steel / TMT reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) Above plinth / Basement level
Providing and laying in position, standardised concrete Mix M-20 Grade using In-situ Concrete batching plant/ Ready Mix Concrete (RMC) adopting weigh batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 1012mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including Conveyance of concrete from batching plant to Work site, Electricity charges and other works & labour cost involved for concrete production, laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).
Supplying and erecting in position LIGHT DUTY STE... CYCLE STAND, PARKING GARAGE, TEMPORARY ENCLOSERS
Supply and fixing well ring for water tank (Rcc Well ring 6 feet Dia)(1 No-2500)
Plumbing work
Supply and fixing Ro Filter (50 Liter)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_767821.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.83 MB
8986-A.pdf
Tender Documents • 0.48 MB
BOQ_767821.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .