Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC 1ST FLOOR RAGHUNATH MARKET NEAR TELEPHONE EXCHANGE PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | ₹1.3 Cr | L1 | Accepted-AOC EMD recovered from RA Bills |
| 2 | L2₹1.6 Cr+₹34.7 L (27.0%)Rejected-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | ₹1.6 Cr+₹34.7 L (27.0%) | L2 | Rejected-Finance Not quoted lowest price. |
Tender Value
₹1.8 Cr
EMD Value
₹3.6 L
Closing Date
22 Feb 2022, 5:30 pmClosed
Jt. GM (EE)
Jt. GM (EE), AAI, Amritsar International Airport.
Annual operation and maintenance contract of E and M installations in Ancillary Building and AAI Residential colony at SGRDJ International Airport, Amritsar (for 02 years).
2022_AAI_103723_1
AAI/ASR/Engg-E/E-14/2021-22
Open Tender
Electrical Works
Works
730 days
Amritsar Airport
As per Tender Document
18 documents required · 18 mandatory
₹1,180
₹3.6 L
13 Aug 2022
2 Feb 2022
24 Feb 2022
2 Feb 2022
22 Feb 2022
2 Feb 2022
2 Feb 2022 - 8 Feb 2022
Amount
Preventive / breakdown maintenance, repair and operation of Electrical & Mechanical installations in AAI Residential Colony, Cargo Complex, CWC Building, MT Section, AAI Colony Street lights, Park lights, Community hall, Approach Road & Cargo Road lights, Old Power House, Transmitter, CISF ladies Barrack etc. and also operation of fresh water and sewerage pumps including repair & maintenance of above facilities , attending to complaints/ faults/ breakdowns and taking recification action, ensuring serviceablility / satisfactory working condition of the system, maintenance of records / documentation etc. as per the detailed specifications, terms and conditions covered under this contract on all days including Sunday and holidays through out contract period.
Digging, dismantling of cable for finding out the fault in LT underground Cable and after repairing laying of the same direct in ground including putting new sand and using old bricks and making good the same.
Maintenance of Ceiling Fans upto 1400 mm sweep Overhauling , Oiling and greasing of fan, bush, replacement, quarter pins, wire with 1.5 sq.mm copper wire & other minor repairs i/c pasting of the sticker clearing mentioning date of maintenance complete as required.
Maintenance of Exhaust Fans upto 450 mm Overhauling , Oiling and greasing of exhaust fan, bush, replacement, quarter pins, wire with 1.5 sq.mm copper wire & other minor repairs i/c pasting of the sticker clearing mentioning date of maintenance complete as required.
Rewinding of Ceiling fan motor upto 1400 mm sweep with suitable copper winding wire as reqd complete in all respect i/c pasting of the sticker clearing mentioning date of rewinding. (Dismantle copper wire shall be kept by the contractor need not to be returned & rewound motor will have minimum waranty period of 06 (Six) months).
Rewinding of Exhaust fan motor upto 450 mm sweep, desert coolers motor with suitable copper winding wire as reqd complete in all respect i/c pasting of the sticker clearing mentioning date of rewinding . (Dismantle copper wire shall be kept by the contractor need not to be returned & rewound motor will have minimum waranty period of 06 (Six) months).
Rewinding of wall mount fan motor upto 650 mm sweep, with suitable copper winding wire as reqd complete in all respect i/c pasting of the sticker clearing mentioning date of rewinding . (Dismantle copper wire shall be kept by the contractor need not to be returned & rewound motor will have minimum waranty period of 06 (Six) months).
Upto 450 mm
Between 450 mm to 650 mm
Overhauling of desert coolers i/c replacement of wood wool, manifold pipes, oiling greasing of fan motor, pump motor, painting etc as required complete in all respect.
Lifting / lowering of followings, sumbmersible pump motor / sewerage pump motor i/c dismantling, checking, re-installation after repairs etc as required complete in all respect.
5/7.5 HP submersible pump motor set
10/12.5 HP submersible pump motor set
Rewinding of followings,submersible pump motor / sewerage submersible pump motor / monoblock pump motor with suitable size of copper winding, Replacement of bush, bearing, seal and other worn out spares i/c testing commissioning etc. as required complete in all respect. (Dismantle copper winding shall be property of the contractor).
0.5 /1/3 HP motor of submersible/ monoblock pump motor
5/7.5/ HP motor of submersible/ monoblock pump motor
10/12.5 HP motor of submersible/ monoblock pump motor
Repairing / Overhauling of pumps sewerage submersible / monoblock etc. i/c replacement of worn out spares like defective bush, impellers, seals and any other associated parts etc. as required complete in all respect.
0.5/1/3 HP pump of submersible
5/ 7.5 HP motor of monoblock pump
10/ 12.5 HP motor of monoblock pump
Preventive / breakdown maintenance, repair and operation of Electrical & Mechanical installations in AAI / BCAS Builiding , fresh water and sewerage pumps including repair & maintenance of above facilities, attending to complaints/ faults/ breakdowns and taking recification action, ensuring serviceablility / satisfactory working condition of the system, maintenance of records / documentation etc. as per the detailed specifications, terms and conditions covered under this contract on all days including Sunday and holidays complete as required.
Annual Comprehensive Maintenance Contract of 01 No. 20 KVA ONLINE UPS (MAKE EMERSON) including preventive & breakdown maintenance through OEM attending to complaints/ faults/ breakdowns and taking recification action, ensuring serviceablility / satisfactory working condition of UPS, maintenance of records / documentation etc. complete as required & as specified on all working days complete as required.
Annual maintenance contract of Electronic Weighing Scales for routine, preventive and breakdown maintenance on monthly basis including all spares except load cells as per manufacturers standards/ AAI Guidelines of the following capacities and accquary class complete as required and as per direction of Engineer-in-charge (For a period of 24 Months).
Capacity 1000 Kg, accuracy class-II, Make LEOTRONIC (For 1st Year)
Capacity 5000 Kg, Lazy Pallet Dolly (For 1st Year)
Capacity 1000 Kg, accuracy class-II, Make LEOTRONIC (For 2nd Year)
Capacity 5000 Kg, Lazy Pallet Dolly (For 2nd Year)
Govt. Fee for stamping
Capacity 1000 Kg, accuracy class-II, Make LEOTRONIC (For 1st Year)
Capacity 5000 Kg, Lazy Pallet Dolly (1 no.) (For 1st Year)
Capacity 1000 Kg, accuracy class-II, Make LEOTRONIC (For 2nd Year)
Capacity 5000 Kg, Lazy Pallet Dolly (1 no.) (For 2nd Year)
Supply of Load Cells, as and when required.
Capacity 1000 Kg, accuracy class-II, Make LEOTRONIC
Capacity 5000 Kg, Lazy Pallet Dolly
Providing & fixing of AC single phase static energy meter of accuracy class 1.0, rating 5-30 amp, 240 V, 50 Hz in Polycarbonate body with LCD type display and pilfer proof meter box with sealing screw provision complete as required as per AAI approved make.
Providing & fixing of AC 3 phase static energy meter of accuracy class 1.0, 3 X 240 V, 50 Hz with backlit LCD type display of rating 10-60 amp (measures and displays KWh only) with transparent hinge type box complete as required as per AAI approved make.
Replacement of defective pressure guage strainer and charging with salt including servicing of water treatment plant of BCAS building complete as required.
Supply of following lamps of different sizes complete as required.
36w/40w Flourscent Tube Light
28W T-5 tube light lamp
Supply of following Wattages, Cap types, Compact Flourocent Lamp suitable to operate on 240 volt, 50 Hz single phase AC supply complete as required.
CFL 15W ordinary holder type
CFL 18W 2 Pin
Supply of following size of Lamp holders complete as required.
Holder button /angle /padent
Supply of following type of MCBs, RCCBs & Isolators suitable for 220V, 50Hz AC supply complete as required.
MCB 40A C Series TPN
MCB 63A C Series TPN
MCB 40A C Series DP
MCB 10A C Series SP
MCB 25A C Series SP
MCB 32A C Series SP
MCB 40A C Series SP
FP 40A RCCB, 100mA
FP 63A RCCB, 100mA
RCCB 40Amp Double pole, 100mA
Supply of Capacitor/Condenser for Ceiling fan/Exhaust fan, tube light & Vapour Lamps suitable for 240 volt and 50Hz A.C. Supply complete as required.
Supply of Starter for 36 watt Fluorescent Tube Light of approved make complete as required.
Supply of Ding Dong Bell of approved colour, make, suitable for supply voltage 230V, 50 Hz single phase AC supply complete as required.
Suppy of following type of Ceiling Fans, Exhaust Fans & Wall fans of different sizes complete as required.
Ceiling Fan (1200mm)
Exhaust Fan (300mm) heavy duty Metalic body
Wall Mounted Fan (400mm)
Ventilation Fan Plastic body (250mm)
Supply of 100W Mini Fan Regulator (Electronic step type) suitable for supply voltage 230V, 50 Hz single phase AC supply complete as required.
Supply of drivers suitable for the following type of LED Street Light luminiaries complete in all respect as required at site.
120watt (Make:Havells,Model:Endura cityliner Neo N)
70 watt (Make Instapower, Model Middy Zenith)
30watt (Make Instapower, Model Micro Zenith)
110 watt (Make philips, model
150 watt (Make philips, model
Supply of following Wattages, Cap types, Led bulb suitable to operate on 240 volt, 50 Hz single phase AC supply complete as required.
LED 15W ordinary holder type
LED 15W Screw type holder
Supply of Capacitor/Condenser for running/starting of motor/pump, suitable for 240 volt and 50Hz A.C. Supply complete as required.
100/120 microfarad
Supply of following sizes PVC insulated & PVC round sheathed copper conductor (flexible) industrial cable, 1100V confirming to IS: 694 (01 coil = 100 meter) complete as required.
3 x 1.5 Sqmm
3 x 2.5 Sqmm
3 x 4 Sqmm
Supply of following sizes (Nominal Cross sectional area based on CR value as per IS) PVC insulated, Stranded, Copper conductor, FRLS, House hold wiring cable of approved make and different colour (1 coil = 90 meters).
1.5 Sqmm, Single core
2.5 Sqmm, Single core
4.0 Sqmm, Single core
Supply of following rating Plug Tops complete as required.
Plug Top - 5 Amp.
Plug Top - 15 Amp.
Supply of PVC casing caping of size 25mm x 12mm complete as required.
Supply of following Piano type Switches & Sockets complete as required.
Supply of 5/6Amp Piano Type Switch
Supply of 15/16Amp Piano Type Switch
Supply of 5/6Amp Piano Type Socket
Supply of 15/16Amp Piano Type Socket
Switch/socket combined 15Amp
Supply of following Modular type Switches & Sockets complete as required.
Supply of 10Amp Modular Type Switch
Supply of 20Amp Modular Type Switch
Supply of 10Amp Modular Type Socket
Supply of 20/10 Amp Modular Type Socket
Supply of LED batten 20 watt with mounting accessories as per AAI approved make.
Supply of XLPE insulated & PVC sheathed Aluminium conductor aurmoured Cable of grade 1.1 KV confirming to IS:7098(part-1)/ IS:1554(part-1) with up to date amendments of following sizes as per AAI approved make:
4x10 SQMM
3.5x25 SQMM
3.5x50 SQMM
3.5x95 SQMM
Supply of desert cooler pump (ISI Marked).
Complete item of CPWD schedule of rates electrical 2018 (Rates shall be quoted it multiples eg. 0.99 or 1.01% below/above. (Including Labour Cess & excluding GST @ 12%).
Manish Electricals
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .