Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Rejected-Technical | Rejected-Technical All Pre Qualifying conditions not Fulfilled |
Tender Value
Refer Docs
EMD Value
₹46,900
Closing Date
30 Nov 2023, 1:00 pmClosed
S.E, EUCC-V, LESA, Cis-gomti,Lucknow
Room No.61, LESA Bhawan, Near Residency park, Kaiserbagh, Lucknow
As per tender Specification
2023_MVVNL_862562_2
36/EUCC-V/LESA/2023-24
Open Tender
Electrical Works
60 days
Sports Authority Of India Limited Kanpur Road, LKO
As per tender Specification
2 documents required · 2 mandatory
₹3,540
A/c. No. 10101985364, IFSC CODE No.SBIN0003347,SBI
₹46,900
14 Dec 2023
23 Nov 2023
30 Nov 2023
23 Nov 2023
30 Nov 2023
23 Nov 2023
Amount
Dragging, loading, carriage and unloading of following store materials with proper stacking from ESC Daliganj to JE dumps store and from JE dump store to work site within municipal area.
33 KV VCB 800 Amp. 750 MVA
33 KV Control Pannel single circuit Transformer
33 KV Lightening Arrester 400 Amp.
33 KV Bus Isolator
33KV Current Transformer 200/100/1
33 KV Cable jointing kit (3x300mm2) outdoor
11 KV Incoming VCB 600/300/5A, 350 MVA
11 KV Out going VCB 200/100/5A, 350 MVA
11 KV VCB Bus coupler, 350 MVA
Battery charger 24 Volt
Battery set 24 Volt
ACSR Panther Conductor for Bus Bar
11 KV 3x300mm2 XLPE Cable
11 KV 3x300mm2 Outdoor Termination Kit
11 KV 3x300mm2 Indoor Termination Kit
11 KV 3x120mm2 XLPE Cable
11 KV 3x120mm2 Outdoor Termination Kit
11 KV 3x120mm2 Indoor Termination Kit
11 KV 3x120mm2 Straight though
ST pole 11 mtr long
M.S.channel 100x50 sq mm
M.S.Angle 65x65x6 sq mm
11 kv pin insulator
11 kv pin with nut
M S Earthing Rod 20x2500 mm
1x240 LT XLPE Cable
MS Channel 125x65mm 3.5m long 4 Nos Pieces [email protected] Kg. Mtr. With wastage
MS Angle 75x75x6, 2.6M 2 Nos Total [email protected] Kg./M with wastage
MS Angle 50x50x6 mm
Rail 105 Lb
MS Round of 32 mm dia for laying of main earthmat in switch yard & for panel earthing bridge [email protected] Kg./M
Earthing of substation Switchyard.
Earthing of substation Switchyard complete by round bar 32 mm dia exavation of earth for laying of earth mat 750mm deep and proper leveling after laying of earth mat Complete as per specification and connecation of all switchyard equipment by GI Flat 50x6 mm (The contractor shall arrange all the material except MS Round Bar 32 MM)
Cutting ,fabrication and driving of earth electrode of size 32x3000 mm
Cutting shaping, laying and welding of riser strip size 50x6mm G.I strip of size 50x6 mm in between earth mat and equipments /structure/body of T/F for earthing (two nos Riser for each structure equipment individually )
Earthing of Indoor Equipment by making of 2 Nos. Quard of round bar 32 mm dia as per norms.
Fabrication & Erection of cable stand made of two nos MS channel 100x50x3 mtr. Long jointed to each other by means of 05 nos MS strip 50x6 mm of size 150 mm Long each by welding at equal distance interval as per norms and grouting in block of 300x300x700 completely providing two nos cable clamp also.(All materials will provide by contractor except MS channel).
Painting of all structures equipment.
Construction of Power T/F plinth suitable for 33/11KV 05 MVA power T/F of size 4x3x1.3 having 0.4 mtr height above ground level. The work includes excavation of foundation base concreting in cc ratio 1:6 M as 12 1st class brick work in ratio 1:4 with coarse sand ,foundation cc in ratio 1:4:8 using M.S bar of 12 mm dia for reinforcement the work includes laying of 2 nos rail pieces 4 mtr long as per drawing/practice the plinth shall be finished in all respect. (only rail piece and M.S angle provided by the department)
Construction of masonry type plinth for 33KV VCB of size 1.6x1.6x1 M brick, sand, cement and stone grit including grouting of 4 Nos foundation Bolts for erection of 33KV VCB.
Isolator Structure-Fabrication of Isolator structure minimum 3.5 mtr overall height and 2.5 mtr above ground level as per RESSPO drawing, with help of M.S channel 125x65 mm two pieces of M.S channel joined to each other by M.S flat 50x6 mm, diagonally at the interval of 0.5 mtr and top & bottom of the structure. Grouting of Isolator structure in CC (cement ,coarse sand and stone grit of 20 mm gauge) including supply of necessary T&P and painting os structure complete.(only M.S channel and angle provided by the deptt)
Lightning Arrestor/ CT structure/ PT structure : - Fabrication of lightning arrestor/CT structure/ PT structure as per RESSPO drawing with the help of 2 nos M.S channel 125x65 mm minimum 3.5 mtr long grouting 1 mtr deep from ground level in cc in ratio 1:4:8. complete in all respect. (M.S channel and angle provided by the deptt)
Erection of structures, grouting and Plinthing of all structures equipment.
Mounting of accessories/equipment on fabricated structure complete work with making proper alignment and tightening the work includes fabrication work if required for proper operation of equipment .
33 KV VCB
33 KV lightning Arrestors
Bus/Line Isolator
Fabrication & Erection of Neutral Stand structure with foundation (M.S channel and angle provided by the deptt)
Erection and commissioning of 05 MVA T/F mounting of radiator conservator tank exposure vent etc. Filling of T/F oil in radiator conservator tank with complete work as per RESPO Norms.
Jumpering complete T/F bay with ACSR panther Cond. and required clamp with nut & Bolts from 33KV existing bus bar & 33KV cable to T/F (with copper L piece) complete work.(01 no. T/F bay)
Laying of Double circuit 11 KV 3x300 sq mm XLPE cable in normal soil by digging of suitable size of trench as per site condition cable should be covered by bricks and sand.
Laying of Double circuit 11 KV 3x300 sq mm XLPE cable in Existing trech.
Hoisting, jumpering, clamping of 11KV 3x300 sq mm XLPE cable on cable stand/panel with proper taping with the help of empire tape. PVC tape and connectors.
Hoisting, jumpering, clamping of 11KV 3x120 sq mm XLPE cable on 11 KV Outgoing Panel with proper taping with the help of empire tape. PVC tape and connectors.
Construction of Control cable trench of size 150 mm wide 300 mm deep with brick work along with provision trench cover M.S strip at the interval of 0.30 M and M.S angle at both the edge of the trench.
Construction and fixing of trench cover0.5 M wide 0.75 mm thick with cement, coarse sand & stone grit in ratio 1:2:4 for covering of cable trench150 mm wide with provision of M.S Angle and MS Bar as per RESPO Norms
Supply & Laying of copper control cable of following sizes its proper dressing ,ferruling and connection with the system.
Copper Control Cable 2x2.5 Sq. mm.
Copper Control Cable 4x2.5 Sq. mm.
Copper Control Cable 6x2.5 Sq. mm.
Pipe boring type earthing minimum 20 mtr deep from ground level or upto water level with B class G.I. pipe 2 " dia. Connection of equipment with earthing by GI strip 50x6 mm included in the job as per specification/norms for power transformer, VCB, CT/LA and other. (All materials will be Provided by contractor)
Supply and installation of fire extinguisher Co2 type 4.5 Kg at suitable place as per RESPO Norms
Shifting of old 33 KV control panels, Battery Set etc. for Installation of new Panels.
Dragging of following panels from unloading place upto control room and placement erection and grouting, commissioning & testing of the same as per RESPO Norms
33 kV T/F Control panel S/C
11 KV Incoming VCB 600/300/5A
11 KV Out going VCB 200/100/5A
Bus Coupler 350 MVA
Supply of Rubber mat 2x1.5 Mtr.
Erection of 24 V batteries set with charger including stand (stand shall be provided by contractor) & initial charging complete set.
Construction of Toe wall around the outdoor Switchyard of the S/S of size 0.75x0.25 Mt.At Base and 0.25 Mt. At top as per RESSPO Norms by lst class bricks in the ratio 1:6, Base concreting of the wall to be done in ratio1:6:12 and plaster 12 mm thick in ratio 1:4.
Fabrication of switchyard fencing with wiremesh 10 SWG (37mmx50mm) as per drawing along with Fabrication of one number gate made of MS Angle, MS Channel, MS Flat together with locking arrangement, its Installation including the cost of civil material, angle 50x50x6mm, Channel Etc .
11 KV LINE WORK
Laying of Double CKT 11 KV 3x120 sq mm XLPE cable in digging of trench 800 mm deep, 650 mm wide its boxing with brick,sand,stone slab after laying of cable filling and proper levelling& ramming. The ferruling of cable also include in this work
Laying of D/C 11 KV 3x120 sq mm XLPE cable in by HDD method as per Norms. The ferruling of cable also include in this work
Laying of D/C 11 KV 3x120 sq mm XLPE cable in by HDD method in GI Pipe as per Norms. The ferruling of cable also include in this work
Fabrication, erection, grouting, plinthing & painting of double pole for 11 KV cable exposure on ST. Pole 11 Mtr long with fixing of necessary clamp channel ,angle 11 KV Pin & pin insulator making double ckt 3 phase 3 wire bus bar for separate cable with single core cable including electrode earthing , danger boared,barbed wire complete in all repect as per RESPO Norms .
Hoisting of 11 KV 3x120 sq mm sizes of 11 KV single cable on existing/erected double pole including GI pipe 3 mtr long 4'' dia including jumpering,dressing of cable with required all necessary clamps and nut, bolts.
Digging of Pit in kachcha/Pakka land in 1.2 mtr deep 3 mtr long and 2 mtr wide for 11 KV ST/TH 3x120 sq mm and boxing with brick sand and stone slab as per norms.
B.N. ENTERPRISES
Sidhi Enterprises
Saraswati Electricals & Contractors
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid