Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.5 LAccepted-AOC NAYA BASS MAHAMANDIR JODHPUR RAJASTHAN 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L1 | Accepted-AOC Accepted as L1 | |
| 2 | L2₹28.5 L+₹1.0 L (3.75%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹29.2 L+₹1.7 L (6.34%)Rejected-Finance JAISALMER | BARMER | RAJASTHAN | 344001 | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹30.5 L+₹3.1 L (11.2%)Rejected-Finance 141 SHANTI NAGAR MODEL TOWN MODEL TOWN PANIPAT HARYANA 132103 | PANIPAT | HARYANA | 132103 | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹31.7 L+₹4.3 L (15.6%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
1 Jun 2020, 6:00 pmClosed
GE (A) JAISALMER
GE (A) JAISALMER
REPAIR AND MAINT OF GI CI DI PIPE LINE ZONE I INCLUDING CLEANING OF OVERHEAD TANKS UG SUMPS MISC WORK UNDER THE JURISDICTION OF GE (A) JAISALMER
2020_MES_340177_1
8902/E8
Open Tender
Civil Works
Item Rate
180 days
GE (A) JAISALMER
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (A) JAISALMER
₹60,000
Yes
29 Aug 2020
22 Apr 2020
3 Jun 2020
22 Apr 2020
1 Jun 2020
9 May 2020
Amount
Taking up or down carefully steel water tubing and connection from any place including cleaning for refixing or to be issued as Sch of Credit of following sizes:-
(a) 20 mm bore.
(b) 25 mm bore.
(c) 40 mm bore.
(d) 50 mm bore.
(e) 80 mm bore.
(f) 100 mm bore.
Refixing of old steel water tubing and connections in new or old position (wall/floor/ceilling/trecheh etc) of following sizes:-
(a) 20 mm bore.
(b) 25 mm bore.
(c) 40 mm bore.
(d) 50 mm bore.
(e) 80 mm bore.
(f) 100 mm bore.
Supply and fix complete to walls / ceilings or laid in floors/trenches steel water tubing galvanised medium grade with all fittings of following sizes:-
(a) 20 mm bore.
(b) 25 mm bore.
(c) 40 mm bore.
(d) 50 mm bore.
(e) 80 mm bore.
(f) 100 mm bore.
M & L for cutting existing GI tubing for alteration or additions of sizes including screwing existing GI tubing for tapping & making new connections etc of following sizes complete all as specified & directed by Engr-in-Charge.
(a) 20 mm bore.
(b) 25 mm bore.
(c) 40 mm bore.
(d) 50 mm bore.
(e) 80 mm bore.
(f) 100 mm bore.
S&F in repairs gun metel,globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for the follwing sizes with ISI marked and as per IS 14846 all as specified and directed by the Engineer-in-Charge.
(a) 20 mm bore.
(b) 25 mm bore.
(c) 40 mm bore.
(d) 50 mm bore.
(e) 80 mm bore.
(f) 100 mm bore.
S & F in repairs butterfly valve, high pressure with crutch or butterfly handle for iron pipe or for unions of follwing sizes complete all as specified.Make: Audco/SIR
(a) 80 mm bore.
(b) 100 mm bore.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out in any type of soil
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out soft / disintegrated rock.
Returning, filling in, including spreading, leveling watering and well ramming in layers of soil not exceeding 25cm.
Returning, filling in, including spreading, leveling watering and well ramming in layers of rock not exceeding 25cm.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point of soil.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point of rock.
M & L for Burning of lead joint in position (old lead will be contractors property for which credit will be given separately) for the pipes of following sizes:-
(a) 80 mm bore.
(b) 100 mm bore.
(c) 150 mm bore.
(d) 200 mm bore.
(e) 250 mm bore.
(f) 300 mm bore.
(g) 350 mm bore.
(h) 400 mm bore.
M &L for run lead joint to spigot and socketed end pipes specials of following sizes:-
(a) 80 mm bore.
(b) 100 mm bore.
(c) 150 mm bore.
(d) 200 mm bore.
(e) 250 mm bore.
(f) 300 mm bore.
(g) 350 mm bore.
(h) 400 mm bore.
S&F in replacement mechanical/Detachable/Victaulic joints(class 10) with nut bolts washers rubber gaskets etc suitable for CI/DI pipes of following sizes:-
(a) 80/100 mm bore.
(b) 150/200 mm bore.
(c) 250/300 mm bore.
(d) 350/400 mm bore.
Taking down old u/s Sluice valve of any size
Supply and fix Sluice valve PN-1.6 with gun metal spindle and wedge nut ISI maked (IS-14846:2000) complete with iron wheel of following sizes:- Note:- Rate includes neccesary arrangements and cutting the pipe of required dimension with attachments for fitting the sluice valve.
(a) 80 mm bore.
(b) 100 mm bore.
(c) 150 mm bore.
(d) 200 mm bore.
(e) 250 mm bore.
(f) 300 mm bore.
(g) 350 mm bore.
(h) 400 mm bore.
M & L for taking out sluice valves refacing , regrinding and refixing alongwith rubber gasket complete of following sizes :-
(a) 80 mm bore.
(b) 100 mm bore.
(c) 150 mm bore.
(d) 200 mm bore.
(e) 250 mm bore.
(f) 300 mm bore.
(g) 350 mm bore.
M & L for taking out stainless steel spindle out of sluice valve and refixing it with new one with neccessay attachments to fit the existing valve complete for the following sizes :-
(a) 80 mm bore.
(b) 100 mm bore.
(c) 150 mm bore.
(d) 200 mm bore.
(e) 250 mm bore.
(f) 300 mm bore.
(g) 350 mm bore.
Taking up carefully from trenches/walls/pillar CI/DI water mains incl all fittings with spigot and socket ends and lead joints incl burning out lead joint/rubber gaskets/lead wool/tyton joint for the following sizes:-
(a) 80 mm bore.
(b) 100 mm bore.
(c) 150 mm bore.
(d) 200 mm bore.
(e) 250 mm bore.
(f) 300 mm bore.
(g) 350 mm bore.
(h) 400 mm bore.
Relaying, realigning the DI/CI pipe line with spigot and socket ends (in any length) on wall/pillars with necessary fitments (tyton joint/rubber gasket,etc) for complete assembly of following sizes complete in all respect all as specified & directed by Engineer-in-charge.
(a) 80 mm bore.
(b) 100 mm bore.
(c) 150 mm bore.
(d) 200 mm bore.
(e) 250 mm bore.
(f) 300 mm bore.
(g) 350 mm bore.
(h) 400 mm bore.
Supplying, fixing and testing of CI/DI pipe fitting for spigot socketed pipes such as bends (any type, radius and angle), tapers any type (straight, bend, increasing/ decreasing or double socket etc). Tee pieces, single branch, “Y” junction, double branch, cross (all sockets or socket and spigot), collars, caps and plugs, for pipe upto 400mm bore all as specified & directed by Engineer-in-charge. Note:- Rate of cutting existing pipe for insertion of the fitting is included in the quoted rate.
M&L for PCC (1:3:6) type C-2, using 40 mm graded stone aggregate as in foundation concrete, mass concrete etc.
Construction of valve chamber of size 120 x 120 x 120 cm (internal dimensions) with the following specifications :-
(i) 15cm thick PCC 1:4:8 type D-2 (using stone aggregate) as in foundation concrete.
(ii) PCC solid block masonry 200mm thick using grade C-5 block in CM 1:6
(iii) Rendering 15mm thick in CM 1:4 finished even and fair.
(iv) PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in coping.
(v) 3mm thick MS sheet cover alongwith MS angle iron frame 40 x 40x6 mm duly embedded in coping concrete with necessary locking arrangement.
(vi) Painting MS sheet cover and frame with two coats of synthetic enamel paint over a coat of red oxide primer.
(NOTE : Excavation and earthwork shall be measured and paid seperately under respective items of Sch 'A')
S & F in repairs foot valve cast iron assembly of following sizes:-
(a) 50 mm bore.
(b) 65 mm bore.
(c) 80 mm bore.
(d) 100 mm bore.
(e) 150 mm bore.
Supply and fix in replacement cast iron non return (reflux) valve both flanged ends in swing type design as per IS 5312 Part-1, PN-1.0, of following sizes:-
(a) 80 mm bore.
(b) 100 mm bore.
(c) 150 mm bore.
(d) 200 mm bore.
M&L for cleaning of pump house/sub station,surrounding area by surface excavation upto 10 cm depth incl removing shrubs,grass,miniplants and other unwanted materials and levelling complete in soft/loose soil all as specified and directed.
Earthing complete with copper plate 60×60cm ×3.15mm thick electrode and 25×3mm copper strip as earthing lead, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level,connected by means of brazing at bolts, nuts, check nuts and washers of copper all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed by Engr-In-Charge.
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate & salt up to ground levl connected to galvanized iron strip 25 x 3 mm as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection and testing on completion complete all as specified and directed. (NOTE:-GI earth strip and protection pipe beyond 7.5m will be measured and paid separately)
M&L for main earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit /pipe or fixed to pole or any other indicated situation for loop earthing etc of galvanised strip 25x3 mm.
Supply and laying in replacement ductile iron pipe with internal cement mortar lining and external zink pipes with class of pipe K-9 of following sizes:-
(a) 80 mm bore.
(b) 100 mm bore.
(c) 150 mm bore.
(d) 200 mm bore.
(e) 250 mm bore.
(f) 350 mm bore.
(g) 400 mm bore.
M & L for cutting of branches of tree of various length to keep a clear pump houses and depositioning the cut branches upto 50 mtr from pump house.
Labour only for attending water supply complaints and rectifying the faults viz no water, water leakage, air lock, low pressure, over flow etc upto entire satisfaction of Engn-in-Charge including all necessary patty items like rubber gasket,grease, screws, GI tees, bends, elbow etc and tool required. Note:- Group of three complaints (max) at one location will be consider as one job. Complaint slip will printed and supplied by Contractor in prescribed format as specified by Engr-in-charge.
M&L for rectifying leakage of CI/DI pipe line including excavation in any type of strata as per site requirement and making arrangement for dewatering by using electric/diesel pump/manual additional labour by caulking with pig lead/ lead wool/ tyton joint complete all as directed for following sizes:-
(a) 80 mm bore.
(b) 100 mm bore.
(c) 150 mm bore.
(d) 200 mm bore.
(e) 250 mm bore.
(f) 300 mm bore.
(g) 350 mm bore.
(h) 400 mm bore.
M&L for rectifying leakage of GI pipe line including excavation in any type of strata as per site requirement and making arrangement for dewatering by using electric/diesel pump/manual additional labour,taking out existing joint/holes/cracks and making new joint including all GI fittings such as sockets/elbow/tee/bend/union,etc complete all as directed for following sizes:-
(a) 20 mm bore.
(b) 25 mm bore.
(c) 40 mm bore.
(d) 50 mm bore.
(e) 80 mm bore.
(f) 100 mm bore.
Supply, fixing and testing, cast iron air release valve with two air outlet and fixing in existing CI/ DI water supply mains complete including necessary cutting/ drilling inserting tee, nuts, bolts etc including taking out old air release valve complete of follwing sizes all as specified & directed by Engineer-in-charge.
M&L in repairs for fixing MS leakage clamps 150 mm in width made out of 6 mm thick MS Sheet in shape and size duly drilled 2 holes in each side with necessary rubber insertion sheet of required size and MS bolt,nuts & washers incl. excavation/earth work in any type of strata and dewatering of line water for prevention of water leakage from pipeline all as specified and directed suitable for following sizes of CI/DI pipelines:-
(a) 80 mm bore.
(b) 100 mm bore.
(c) 150 mm bore.
(d) 200 mm bore.
(e) 250 mm bore.
(f) 300 mm bore.
(g) 350 mm bore.
(h) 400 mm bore.
M&L dewatering, cleaning of OH reseviors (by professional agency like Narmada water tank cleaners or equivalent) with high pressure jet to remove all mosses, algae and dirt and removal of dirty water along with sludge machines/industrial vacum cleaners and disposal of the same to a safe distance including scrubing of internal surface by steel wire brush, removing the dirt completely using industrial vaccum cleaners and sterilizing the complete internal surface of the tank by using ISI mark Gd I bleaching powder including repair to vent pipes and providing wire mesh and clamps (to stop ingress of pigeons) complete and marking the date of cleaning by using synthetic enamel paint in white colour over black background and letters of height 40 mm height and 30 mm width complete all as directed including one coat of white wash on the internal surface complete all as specified and directed by Engineer-in-charge. Note: If the work is not done upto satisfaction level of concerned JE/AGE (E/M), the work will be redone upto required level without any extra cost. Neccessary tools and safety gears to be arranged by contractor without any extra cost. Labours safety shall be contractors responsiblity.
(a) 20000 Gallons
(b) 50000 Gallons
© 100000 Gallons
M&L dewatering, cleaning of UG sumps (by professional agency like Narmada water tank cleaners or equivalent) with high pressure jet to remove all mosses, algae and dirt and removal of dirty water along with sludge machines/industrial vacum cleaners and disposal of the same to a safe distance including scrubing of internal surface by steel wire brush, removing the dirt completely using industrial vaccum cleaners and sterilizing the complete internal surface of the tank by using ISI mark Gd I bleaching powder including repair to vent pipes and providing wire mesh and clamps (to stop ingress of pigeons) complete and marking the date of cleaning by using synthetic enamel paint in white colour over black background and letters of height 40 mm height and 30 mm width complete all as directed including one coat of white wash on the internal surface complete all as specified and directed by Engineer-in-charge. Note: If the work is not done upto satisfaction level of concerned JE/AGE (E/M), the work will be redone upto required level without any extra cost. Neccessary tools and safety gears to be arranged by contractor without any extra cost. Labours safety shall be contractors responsiblity.
(a) 25000 Gallons
(b) 50000 Gallons
© 100000 Gallons
(d) 200000 Gallons
( e) 450000 Gallons
(f) 700000 Gallons
(g) Static Water Tank 50,000 glns round type
M&L applying one coat of anticorrosive bituminiuos paint on existing paint over ladder of overhead tanks of any capacity upto 20 mtrs staging including preparation of surfaces.
Repairing of ladders/part of ladder in OH Tanks with the help of Arc/Gas welding,cutting , beding etc and two coats of anti corrosivce bitumious paint over a coat of anti corrosive primer complete all as specified & directed by Engineer-in-charge.
Taking down old u/s ultra sonic sensor of any size
Taking down old u/s LED diaplay of any size
Taking down old u/s PVC 2 core cable of any size
S & F ultrasonic level transmitter IP 67, 8 meter range 2 wire with sensor material PVDF, aluminium housing PU painted, top mounting including bracket complete with panel comprising of SMPS NHP 24 DC, 3 Amps and MCB SPN and anything else required for making level sensor operational and provision for fixing 4 digit 7 segment LED display complete testing/calibration for indiacting water level inside OHT(any capacity)/UG sump(any capacity) etc complete all as specified and directed by Engineer-in-Charge. SBEM(ultramate 136-ULT) or equivalent in Endress&Houser, Banner. Note: - Labours safety shall be contractors responsiblity including protective gears for OHR.
S & F 4 digit 7 segment LED display suitable for 230V AC complete fixing in panel for display of water level complete all as specified and directed by Engineer-In-Charge. Make: Selec(PIC101A) or equivalent in L&T, Siemens,TC(C&S).
S& F 2 core 1.5 Sqmm copper conductor complete fixing /saddling/ laying in ground and connecting to level transmitter(OHT/UG sump) at any height complete all as specified and directed by Engr-In-Charge. Make: polycab, Havells, finolex
M&L for preparation/cleaning of old painted steel surfaces of any description such as suction line, delivery line, priming line or not less than 100 mm dia pipe any other pipe line/ channel plates complete with scrapping out old painted surface and after that marking of flow direction along with painting complete all as directed by EIC.
Laying, jointing and testing of cast iron pipes with spigot and socket ends centrifugally cast, class 'LA' suitable for tyton/rubber joint in any length laid in trenches/pillar etc of following sizes complete all as specified & directed by Engineer-in-charge. Note:- Items will be provided under Sch'B' by the department. The cost of transportation of pipe to the required site is included in the rate itself.
(a) 400 mm bore
(b) 350 mm bore
© 250 mm bore
(d) 100 mm bore.
M & L for testing of water sample at authorised government laboratory for biological fitness of water on monthly basis including glass bottle for collection of sample.Note: Sample of water to be collected from wherever directed by Engr-In-Charge will be responsibility of contractor.(Water sample includes area such as Dabla Main P/H and ASC P/H))Note: Collection of sample from all the places at a time will be considered as one job each time
JAI ENGINEERING COMPANY
M/s Shri Inder Construction Company
Chanda Construction Co.
M/s Shree Construction Company
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .