| 1 | L1₹34.3 LAccepted-AOC 67 RAMPURA GANDHI NAGAR JAMMU 180 004 J K | JAMMU | JAMMU | JAMMU AND KASHMIR | 180004 | L1 | Accepted-AOC Being the lowest and reasonable bidder | |
| 2 | L2₹34.8 L+₹27,486 (0.80%)Rejected-AOC 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L2 | Rejected-AOC Being the other than lowest bidder | |
| 3 | L3₹35.9 L+₹1.4 L (4.08%)Rejected-AOC | L3 | Rejected-AOC Being the other than lowest bidder | |
| 4 | L4₹35.9 L+₹1.4 L (4.14%)Rejected-AOC C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L4 | Rejected-AOC Being the other than lowest bidder | |
| 5 | L5₹37.2 L+₹2.7 L (7.81%)Rejected-AOC | L5 | Rejected-AOC Being the other than lowest bidder |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
3 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE Nagrota
HQ CWE Nagrota Co 56 APO
SPL REPAIR/REPLACEMENT OF BER EM PLANT WITH CONNECTED WORK AT 213 TRANSIT CAMP UNDER GE NAGROTA
2023_MES_600072_1
CWE/NGT-17/2023-24
Open Tender
Civil Works
Item Rate
182 days
Transit Camp
As per NIT and tender documents
8 documents required · 8 mandatory
₹500
Yes
GE Nagrota
₹78,000
Yes
21 Jul 2023
1 Jun 2023
10 Jul 2023
1 Jun 2023
3 Jul 2023
15 Jun 2023
1 Jun 2023 - 8 Jun 2023
Amount
Supply, installation, Testing, Commissioning of Oil Cooled, Copper wound, Step down "BIS marked & BEE star labelled " transformer of capacity 100 KVA plinth mounted outdoor type with latest feature complete with standard fitted HT 11 KV 3 phase, LT 433 V 3, phase 4 wire,50 C/S oil immerse, naturally cooled externally cooling tube delta connection on primary HT 11 KV side and star connection on secondary LT 433V with tapping at +/-2.5 %to +/-5 % & +/- 7.5 % on HV side and to be changed by means of hand operated off load tap changing gear including first filling of new transformer oil of dilectric strength not less than 55 KV with all fitting and accessories such as LT box with cable gland, HT box with cable gland, Silica gel, breather, Oil level indicator gauge, drain out valve (oil tank),exhaust vent, air release valve, temp gauge, cast iron wheel etc comply with EEL 2 IS 1180 2014 with amendment 1,2,3 & 4 having total losses @ 50% load 1430W & total losses @ 100% load 4100W. Following items/ Accessories included in this rate therefore No any extra cost will be paid for this items complete all as specified and directed by Engineer-in-charge. (i) Name, rating & diagram plate (ii) Off circuit tap changing switch (iii) Earthling terminals (iv) Lifting lugs (v Oil drain valve with plug (vi) Oil filter valve with plug (vii) Conservator with oil filling hole (viii) Thermometer pocket (ix) Air release plug (x) Silicagel breather (xi) Removable inspection opening (xii) Explosion vent (xiii) Chain link fencing of size 4.5m X 4.5m consisting of angle iron of size 65 x 65 x 6mm of height 2.1 mtr entrance gate and 40mm stone aggregate all around the transformer plinth all as directed . (xiv) Transformer platform as per manufacturer design.
Supply, installation, Testing, Commissioning of Oil Cooled, Copper wound, Step down "BIS marked & BEE star labelled " transformer of capacity 160 KVA plinth mounted outdoor type with latest feature complete with standard fitted HT 11 KV 3 phase, LT 433 V 3, phase 4 wire,50 C/S oil immerse, naturally cooled externally cooling tube delta connection on primary HT 11 KV side and star connection on secondary LT 433V with tapping at +/-2.5 %to +/-5 % & +/- 7.5 % on HV side and to be changed by means of hand operated off load tap changing gear including first filling of new transformer oil of dilectric strength not less than 55 KV with all fitting and accessories such as LT box with cable gland, HT box with cable gland, Silica gel, breather, Oil level indicator gauge, drain out valve (oil tank),exhaust vent, air release valve, temp gauge, cast iron wheel etc comply with EEL 2 IS 1180 2014 with amendment 1,2,3 & 4 having total losses @ 50% load 1430W & total losses @ 100% load 4100W. Following items/ Accessories included in this rate therefore No any extra cost will be paid for this items complete all as specified and directed by Engineer-in-charge. (i) Name, rating & diagram plate (ii) Off circuit tap changing switch (iii) Earthling terminals (iv) Lifting lugs (v) Oil drain valve with plug (vi) Oil filter valve with plug (vii) Conservator with oil filling hole (viii) Thermometer pocket (ix) Air release plug (x) Silicagel breather (xi) Removable inspection opening (xii) Explosion vent (xiii) Chain link fencing of size 4.5m X 4.5m consisting of angle iron of size 65 x 65 x 6mm of height 2.1 mtr entrance gate and 40mm stone aggregate all around the transformer plinth all as directed . (xiv) Transformer platform as per manufacturer design.
Supply, laying, testing and commissioning aluminium conductor, XLPE insulated,PVC inner sheathed, GI strip or wire armoured and overall PVC sheathed ,heavy duty 11000 volts (E) grade in trenches/on surface of wall/ in GI pipe including dressing and clamping the cable with MS Zinc Passivated clamps and fixing suitable thimbles/lugs including cable glands of suitable size etc of cross-sectional area 95 Sqmm 3 core complete all as specified and directed .
S&F cable jointing kit for 11 KV (earthed) cable for outdoor termination heat shrink type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable for sizes 50-95 Sqmm all as specified and directed by Engr-in-Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3.5 core XLPE, armoured, Al conductor cable of size 70-95 Sqmm complete all as specified and directed by Engr-in-charge. .
Supply, laying, jointing and testing and commissioning aluminium conductor, XLPE insulated,PVC inner sheathed, GI strip or wire armoured and overall PVC sheathed ,heavy duty 1100 volts grade in trenches/on surface of wall/ in GI pipe including dressing and clamping the cable with MS Zinc Passivated clamps and fixing suitable thimbles/lugs including cable glands of suitable size etc of cross-sectional area 95 Sqmm 3.5 core complete all as specified and directed .
Supply, laying, jointing and testing and commissioning aluminium conductor, XLPE insulated,PVC inner sheathed, GI strip or wire armoured and overall PVC sheathed ,heavy duty 1100 volts grade in trenches/on surface of wall/ in GI pipe including dressing and clamping the cable with MS Zinc Passivated clamps and fixing suitable thimbles/lugs including cable glands of suitable size etc of cross-sectional area 70 Sqmm 3.5 core complete all as specified and directed .
Switch air break gang operated (Swing out expulsion ruse insulators), tripple pole mechnical operated from ground level mounted on insulator and steel frame (12 insulators type) out door type suitable for vertical installation single break provided with locking arrangement consisting of MS channel HT post top insulator with drop out fuses operating rod 20mm dia GI medium grade pipe worked from ground levelconfirming of IS 1818 of 1972 and contineous current rating upto 200 amp and volt 11 KV complete fixed "as in repairs" including taking down old one all as specified.
Supply, fixing and erection truly in vertical position steel tubular swaged poles complete with cast iron base plate, finaial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.00m long) including painting with two coats of synthetic enamelled, and making alternate white & black strips each 30cm wide upto 1.5 m above from coping complete all as specified and directed.
Cross arm, bracings, supports, clamps and chequered steel back plates, angle iron equal size or any size fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size for cover for cable duct any size and holding of two pole strucures, GOD, street light GI bracket, junction boxes and fabrication of anti climbing devices, other works etc as indicated or directed and duly painted with synthetic enamel aluminium/smooke grey paint over a coat of primer fixed "as in repairs" complete all as specified and directed .
Aluminium conductor, steel reinforced of any size on HT/LT Poles including straining,binding with insulators with Al/copper binding wire with insulators as in OH conductors, providing PVC Sleeves for jumper fixed "as in repairs" complete all as specified and directed .
Lightning arrestor non liner resistor type comply with IS 3070 Part -I 1985 for alternating current system multple spark gap suitable for voltage grade 11000 volt discharge cap 65 KA complete with all fittings and all as specified.
Excavation in trenches in any type of soil not exc 1.5 mtr in depth and 1.5 mtr wide and getting out any type of soil complete for laying of cables.
Returning and filling in including spreading, leveling , watering and well ramming in layers not exceeding 25 cm thick excavated earth complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 mtr and depositing at a leval not exceeding 1.5 mtrs above the starting point complete all as specified and directed.
Sand cushioning to under ground cable laid in trenches for laying of HT/LT UG cables 8 cm wide before laying the cable and 15 cm after laying and punned down to a depth of 10 cm as per MES SSR Part-I (2509) all as specified and directed. Note: Punned thickness shall be measured and paid to the contractor.
M&L for well burned bricks , laid flat ( old size) sub class B designation 75 for cable protection complete all as specifed and directed.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type-2, flat,size 450x180x40mm all as specified and directed.
Supply & fixing is position cable path indicator made out of MS duly embosing the words " LT /HT cable" fixed on MS angle iron , at a distance of every 20 mitres & painting the indicators with 2 coats of synthetic enamel paint (Brown colour) over a coat of red oxide primer complete all as specified and as directed .
Supply and fixing to GI tubing 100 mm Dia light grade under roads/on wall/on pole as cable protection pipe all as specified and directed by Engr-in-Charge.
Supply and fixing to GI tubing 50 mm Dia light grade under roads/on wall/on pole as cable protection pipe all as specified and directed by Engr-in-Charge.
M&L for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level surrounded on all sides by 150 mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to galvanized earth lead wire 4mm (8SWG) by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 40mm dia medium grade GI pipe for earth strip protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point /LT Panel as specified and testing on completion for desired result complete all as specified and directed by Engr-in-charge.
M&L for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level surrounded on all sides by 150 mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to galvanized earth strip 32x6 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit all as shown in electrical plate No 5 of MES SSR Part-I (2009) as specified including provision of 15 mm dia medium grade GI pipe for earth strip protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point /LT Panel as specified and testing on completion for desired result complete all as specified and directed by Engr-in-charge.
GI strip of size 32 x 6 mm for earth continuity conductor or main earthing lead fixed to wall buried in gound fixed alongwith poles complete all as specified.
PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete in foundation of pole etc complete all as specified
Supply, installation, commissioning & testing of Silent diesel engine driven generating set complete with acoustic enclosure, antivibration pads with 75db noise level at 1 mtr distance from DG set and control system for 62.5 KVA output at NTP, AC 415 volts, 50 C/S, 3 phase 4 wire directly coupled complete with self starting system including accessories equipment control panel etc as detailed below:- (a) Alternator:- Alternator 62.5 KVA output at 0.80 PF lag 50 Hz, AC 3 phase, 4 wire 415 volts.The alternator shall be self excited ,self regulated,screen procted ,mountain on rigid frame MS sheet channel base frame of IS B364:IS 4722,BS5000,IEC:34 and brush-less type shall be suitable for tropical climate and IP23 protection with Class 'H' insulation and temperature rise limited to class 'H' insulation limit and permissible overload of 10% for one hour in 12 hours of operation all as specified and directed. (b) Diesel Engine :- Diesel engine of Adequate BHP , water cooled and electric start suitable to drive above alternator independently, coupled directly through flexible coupling, multi cylinder , 1500 RPM industrial type as per BS-649 or IS-1601 with governor suitable to regulate speed of DG set from No load to full load complete with fuel tank of cap as per manufactrer recommendations, fuel lines, exhaust pipe extended upto and outside building duly insulated with asbestos rope and with support and silencer muffles etc for continuous operation and standard accessories, sump, pre heaters, Fuel tank of capacity for 12 hours running of DG set with stop cock, drain plug and necessary fuel pipe, manufactured out of 2mm thick MS sheet, etc all as specified and directed.
Supply and fix Self Priming Non clogging Motor driven dewatering Pumping Set comprissing of 5 HP capacity three phase induction motor Energy efficient IE2 , 1450 RPM, pump having maximum Head 10 mtr, discharge 18 Ltr per second, 415 V on a common base plateforme mounting having 80 x 80 mm suction and delivery with moving arrgement complete. Note : Following items/ Accessories included in this rate therefore No any extra cost will be paid for this items complete all as specified and directed by Engineer-in-charge. (i) impeller : should be cast iron/stainless steel/bronze (ii) Delivery casing : cast iron (iii) shaft : carbon steel/stainless steel (iv) sealing : Gland packed/ Mechanical Seal (v) Motor body : cast iron (vi) class of insulation : F class (Motor coupled only) (vii) Degree of protection :IP 55
Supply and fix Non clogging Pumping Set comprissing of 6 HP capacity, 1500 RPM, pump having maximum Head 20 mtr, discharge 3.5 Ltr per second air cooled coupeled through flexible coupling with Diesel Engine on a common base plateforme mounting with Pump having 80 x 80 mm suction and delivery with moving arrgement all as specified and directed by Engr-in-Charge.Note : Following items/ Accessories included in this rate therefore No any extra cost will be paid for this items complete all as specified and directed by Engineer-in-charge. (i) impeller : should be cast iron/stainless steel/bronze (ii) Delivery casing : cast iron (iii) shaft : carbon steel/stainless steel (iv) sealing : Gland packed/ Mechanical Seal (vi) class of insulation : F class (vii) Degree of protection :IP 55
Supply, installation, commissioning of Deep Freezer single phase 240 volt, 50 Hz, Metal top up electric driven, single phase having capacity up to 320 Ltr all as directed by Engr-in-charge.
Supply, installation and commissioning of Refrigerator Double door partially stainless steel, electric driven, single phase having capacity up to 195 Ltr, BEE 5 Star rated all as directed by Engr-in-charge.
Supply and Install automatic copper wound voltage stabilizer for low and high voltage correction equipped with electronic transistorised relay suitable for connection on single phase 50 HZ AC supply, designed for input voltage of 90 to 290 V and output voltage stablized at 215 to 240 V of Capacity 2 KVA complete with digital voltmeter and ammeter with time delay relay of 2-3 Minute complete all as specified and Directeby Engr in charge.
Note:- Schedule of credit Rs. 16,385.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents.
MOHAN LAL AND SONS
Kalsi Engineers and contractors
MAMTA ENTERPRISES
PROACH ASSOCIATES BUILDERS & ENGINEERS
Jiwan Singh
SHSS ASSOCIATES
M/S RAJ ENGINEERS
RAVI KUMAR
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .