| 3 | L3₹1.8 LRejected-AOC GSTIN: 01AFBPR2044B1ZBBHAGWATI NAGAR JAMMU | ₹1.8 L | L3 | Rejected-AOC NOT THE LOWEST BIDDER |
| Sl No | Description | Qty | Unit | M/S K S ENGG WORKS L2 | BEE AAR ENTERPRISES L3 | M/S TRIKUTA ELECTRICAL & MECHANICAL WORKS L1 |
|---|---|---|---|---|---|---|
| 1.01 | Transportation charges for shifting of worn-out components of the VT pump of 900 VM-2 ,60 Cusecs, discharge,32.30 mtr Head VT pump of pumping Unit No 06 for repairs to the workshop by way of loading in mechanical transport from Tawi pump house and unloading the same at the workshop with the help of E.O.T crane and manual labour. Repairs to 1st shaft enclosing tube of VT pump by way of checking of face-to-face alignment and eccentricity developed in the enclosing tube at different off-sets with the help of dial gauge on lathe machine. Removing of eccentricity developed after welding /patching at the cracked portion with suitable M.S. welding electrodes and also welding of the cracked stiffeners of the flanges of the enclosing tubes. Repairs to 1st shaft and 2nd line shafts of VT pump by way of rebuilding of worn-out seat portion of bearing of the Shafts. Rebuilding 1st & 2nd line shaft by way of extracting worn out sleeve of the shaft and turning shaft to remove unevenness in surface. Turning, finishing, and polishing to required size. Checking of eccentricity developed at the different off-sets of the shaft during operation and removing the eccentricity developed by means of press bench. The tolerance limit be kept within the prescribed limit of +0.03 mm. Repairs to one number guide spider by way of welding of damaged/worn out seat portion of guide spider with suitable C.I. electrodes and finishing the welded portion as required making the surface even. Extraction of broken/damaged bolts by drilling and rethreading the drilled holes for fitment of counter sunk bolts. P/F of rubber pads with counter sunk bolts in all the three arms of guide spiders. Repair to stuffing box of VT Pump by way of extraction of broken/damaged bolts of cover plate by drilling and rethreading the drilled holes for fitting cover plate of rubber bearing. Providing and fitting new gland plate and Cover plate fabricated out of CI material (APS) along with new bolts and washer .providing and fitting 02 nos new studs with nuts for fitting gland bush of stuffing box .Repair to damaged portion of suction bell of pump by way of removing of all the old/ damaged welding from the surface of the entire four No. cross arms and inner portion of suction bell’s body with the help of gas cutter. Rebuilding of the badly damaged inner surface portion of the body and all the cross arms with suitable hard facing electrodes by welding longitudinally and circumferentially for rebuilding and filling of pitting and cavitation’s caused during operations. Finishing of the welded portions with grinder in such a way that the original angle/ profile and the thickness of the body and the cross arms is not disturbed. Drilling of four No. holes with threading as required for fitment of cover plate of rubber bearing. The job further involves back carriage of the repaired components of VT Pump i.e. shaft enclosing tubes, SS line shaft and Muff coupling, guide spider etc. to the site of Tawi pump house by way of loading in mechanical transport at workshop and unloading at site of Tawi pump house, Jammu with the help of manual labour. The job involves replacement of thrust pad of other 02 Nos. guide spider- (06 Nos). Assembling and lowering of extracted VT pump and column assembly it involves complete wiping ,cleaning repaired parts, lowering of complete bowl assembly , column assembly in proper sequence by fitting of column pipes and fitting further, lowering fitting of shaft enclosing tube along with line shaft one by one to discharge head and Tee joint aligning & fitting with rising main of 36” dia. P/F of consumables items during lowering of the VT pump like line shaft rubber bearing 7 Nos.( Provided by the Deptt.) bottom rubber bearing 1No., HT column bolts with nuts 120 x20 mm (reputed make) 18Nos., HT shaft enclosing tube bolts with nut 110x16 mm 22 Nos. HT bolts with nuts 110x25 mm (reputed make) 16 Nos., HT bolts 65x16mm 15 Nos. , HT bolts 45x16 mm 12 Nos., HT Allen key bolts 40x12 mm 15 Nos., spring washers-16mm 30- nos., spring washers 12mm 24 Nos., fire fly sheet 1/32” 6 kg, fire fly sheet 1/16” 7.5 kg., rubber insertion sheet 1/18” 12 kg, gland packing ¾” 2kg, hacksaw blade double edge 6 Nos., HT bitumen tape roll, emery cloth 7 mtr and dhoti cloth. Grease -05 kg and servo system 46-15 litre for topping of motor (servo system46 provided by Deptt.) Fitting of pump and motor half coupling, checking alignment of pump and motor using dial gauge, making all the electrical connection, tightening bolts, providing of gasket, electrical thimbles and then testing on full load. Skilled person shall be provided by the firm for extraction /fitting /assembling of parts during lowering of VT pump. Complete job includes cost of materials and labour charges. | 1 | Job | 1,74,200 ₹1.7 L | 1,75,600 ₹1.8 L | 1,72,500 ₹1.7 L |
Tender Value
Refer Docs
EMD Value
₹3,573
Closing Date
6 Mar 2026, 1:00 pmClosed
executive engineer mech. division rtic jammu
Office of Executive engineer mech. division rtic jammu
Periodic maintenance of 900 VM-2, 60 Cusecs, discharge, 32.30 mtr Head VT pump of pumping Unit No 06 Installed at Tawi Pump House Jammu.
2026_IFC_304534_1
ENIT 48 OF 2025-26 dated 25.02.2026
Open Tender
Electrical and Maintenance Works
21 days
Executive engineer mech. division rtic jammu
Please refer Tender documents.
8 documents required · 8 mandatory
₹200
Yes
Ex Engineer mech. division Rtic Jammu
₹3,573
Yes
Executive engineer mech. division rtic jammu
2 Apr 2026
25 Feb 2026
7 Mar 2026
25 Feb 2026
6 Mar 2026
27 Feb 2026
26 Feb 2026
Transportation charges for shifting of worn-out components of the VT pump of 900 VM-2 ,60 Cusecs, discharge,32.30 mtr Head VT pump of pumping Unit No 06 for repairs to the workshop by way of loading in mechanical transport from Tawi pump house and unloading the same at the workshop with the help of E.O.T crane and manual labour. Repairs to 1st shaft enclosing tube of VT pump by way of checking of face-to-face alignment and eccentricity developed in the enclosing tube at different off-sets with the help of dial gauge on lathe machine. Removing of eccentricity developed after welding /patching at the cracked portion with suitable M.S. welding electrodes and also welding of the cracked stiffeners of the flanges of the enclosing tubes. Repairs to 1st shaft and 2nd line shafts of VT pump by way of rebuilding of worn-out seat portion of bearing of the Shafts. Rebuilding 1st & 2nd line shaft by way of extracting worn out sleeve of the shaft and turning shaft to remove unevenness in surface. Turning, finishing, and polishing to required size. Checking of eccentricity developed at the different off-sets of the shaft during operation and removing the eccentricity developed by means of press bench. The tolerance limit be kept within the prescribed limit of +0.03 mm. Repairs to one number guide spider by way of welding of damaged/worn out seat portion of guide spider with suitable C.I. electrodes and finishing the welded portion as required making the surface even. Extraction of broken/damaged bolts by drilling and rethreading the drilled holes for fitment of counter sunk bolts. P/F of rubber pads with counter sunk bolts in all the three arms of guide spiders. Repair to stuffing box of VT Pump by way of extraction of broken/damaged bolts of cover plate by drilling and rethreading the drilled holes for fitting cover plate of rubber bearing. Providing and fitting new gland plate and Cover plate fabricated out of CI material (APS) along with new bolts and washer .providing and fitting 02 nos new studs with nuts for fitting gland bush of stuffing box .Repair to damaged portion of suction bell of pump by way of removing of all the old/ damaged welding from the surface of the entire four No. cross arms and inner portion of suction bell’s body with the help of gas cutter. Rebuilding of the badly damaged inner surface portion of the body and all the cross arms with suitable hard facing electrodes by welding longitudinally and circumferentially for rebuilding and filling of pitting and cavitation’s caused during operations. Finishing of the welded portions with grinder in such a way that the original angle/ profile and the thickness of the body and the cross arms is not disturbed. Drilling of four No. holes with threading as required for fitment of cover plate of rubber bearing. The job further involves back carriage of the repaired components of VT Pump i.e. shaft enclosing tubes, SS line shaft and Muff coupling, guide spider etc. to the site of Tawi pump house by way of loading in mechanical transport at workshop and unloading at site of Tawi pump house, Jammu with the help of manual labour. The job involves replacement of thrust pad of other 02 Nos. guide spider- (06 Nos). Assembling and lowering of extracted VT pump and column assembly it involves complete wiping ,cleaning repaired parts, lowering of complete bowl assembly , column assembly in proper sequence by fitting of column pipes and fitting further, lowering fitting of shaft enclosing tube along with line shaft one by one to discharge head and Tee joint aligning & fitting with rising main of 36” dia. P/F of consumables items during lowering of the VT pump like line shaft rubber bearing 7 Nos.( Provided by the Deptt.) bottom rubber bearing 1No., HT column bolts with nuts 120 x20 mm (reputed make) 18Nos., HT shaft enclosing tube bolts with nut 110x16 mm 22 Nos. HT bolts with nuts 110x25 mm (reputed make) 16 Nos., HT bolts 65x16mm 15 Nos. , HT bolts 45x16 mm 12 Nos., HT Allen key bolts 40x12 mm 15 Nos., spring washers-16mm 30- nos., spring washers 12mm 24 Nos., fire fly sheet 1/32” 6 kg, fire fly sheet 1/16” 7.5 kg., rubber insertion sheet 1/18” 12 kg, gland packing ¾” 2kg, hacksaw blade double edge 6 Nos., HT bitumen tape roll, emery cloth 7 mtr and dhoti cloth. Grease -05 kg and servo system 46-15 litre for topping of motor (servo system46 provided by Deptt.) Fitting of pump and motor half coupling, checking alignment of pump and motor using dial gauge, making all the electrical connection, tightening bolts, providing of gasket, electrical thimbles and then testing on full load. Skilled person shall be provided by the firm for extraction /fitting /assembling of parts during lowering of VT pump. Complete job includes cost of materials and labour charges.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.22 MB
2.pdf
Tender Documents • 0.37 MB
BOQ_989184.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid