Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 LAccepted-AOC | L1 | Accepted-AOC L1 |
Tender Value
₹4.2 L
EMD Value
₹8,900
Closing Date
31 Jan 2024, 10:45 amClosed
Ex. Engineer(Elect.)/CNZ
C-Block, Defence Colony, New Delhi 110024
Rewiring and Improvement of E.I and Fans at JE(W) Office and Store Near MCD School Sangam Vihar in ward no. 169.under central zone..
2024_SDMC_183521_1
EE(Elect.)/CNZ/2023-24/61-04
Open Tender
Electrical Works
Item Rate
30 days
ward no.169
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹8,900
2 Jul 2025
30 Jan 2024
31 Jan 2024
30 Jan 2024
31 Jan 2024
30 Jan 2024
Amount
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(a)2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 3x2.5
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.(a) 3 x 4 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required b) 25 mm
Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc. as required (a) 5/6 A switch
Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc. as required (a) 3 pin 5/6 A socket outlet
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. A). 4 Module (125mmX75mm)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. A). 6 Module (200mmX75mm)
Supplying and fixing suitable size GI box with modular plateand cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 5/6 &15/16A modular switch, connections etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc.as required.(a) Up to 450 mm sweep
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) B)8 way, Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) Single pole
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required
P/F 6 SWG dia GI wire on surface or in recess for loop earthing as reqd.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) Metre 39
Providing & laying in position cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size in fondation of pump,DG set etc. including form work etc as required.
Supplying and fixing following rating ,double pole,24o volt,isolator in the existing MCB DB complete with connections ,testing and commissioning etc. as required.(a) a) 63 amps
S/I/T/C of LED Tube Type luminiare 20 Watt rating complete with polycarbonate housing Batten integrated electronic driver prewired with high efficient LEDs with the following: (a) Total System Wattage 20 Watt +/- 5%. (b) Luminous Efficieny lumens/watt >= 95 (c ) Power Factor>= 0.95
S/I/T/C Surface mounting CRCA housing 36 watt LED luminiare with acrylic cover Diffuser with following following specifications including fixing on existing wall/surface with connection as reqd. (a) Total System Wattage 36 Watt +/- 5%. (b) Luminous Efficieny >= 95 (c ) Power Factor>= 0.95
SITC of single phase monoblock pumpset complete with all accessories workable of 240 Volts 50 Hz AC supply (a) 1 HP (0.75 KW) single phase pumpset head from 12-30 metre suction and delivery 25X25 mm.
Supply of XLPE insulated and PVC sheathed Al. conductor armoured cable 1.1 KV grade confirming to IS 7098 as required. (a) 2 x6 sqmm
S/I/T/C of 60 watt LED Flood Light luminaire fitted with lens made of pressure die cast aluminium housing & toughened glass cover complete with the following specifications as required with IP 66 protection .(a) Total System Wattage 60 Watt +/- 5%. (b) Luminous Efficieny >=100 (c ) Power Factor>= 0.95 (d) Protection Class- IP-66
P & F of Hot Press Sheet Moulded Compound (SMC),fire retardant (Temp. resistanceup to 200 C),IP-55 weather proof pole box of inner dimension 200 mmx160 mmx98 mm (NS) complete with suitable arrangement for fixing of 2 nos.of 6 to 32 amp single pole MCB & 63 A Double pole( MCB/isolator excluded) with neutral link duly shorting on DIN channel with 2 nos.of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc. as required.
Supply and fixing of full stainless steel body self contained drinking water cooler with cooling capacity 150 ltr per hr, storage capacity 150 ltr & suitable for 230 V supply as reqd.
Supply & Installation of Reverse Osmosis (RO) water purifier of capacity 50 Ltr/hr complete as required.
S/I/T/ C of 4 KVA Voltage stabilizer having input voltage 150V - 270V and output voltage of 195 V -245 V .
Supply of 10'' (250 mm )sweep, 1250 rpm exhaust fan Fresh air Typecomplete with shutter, blades etc as required.
Supply of 1200 mm sweep 50 watt energy saver ISI mark BEE 5 star rating A.C ceiling fans suitable for 230 volt, 50 hertz AC supply without regulator with blades down-rod etc complete as required.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .