GE(U) E/M Meerut Cantt
Roorkee road Meerut cantt
REPAIR/ MAINT OF 33 KV MRS AND ALLIED WORKS UNDER AGE (E/M) ELECTRIC SUPPLY AT GE(U) E/M MEERUT CANTT
2022_MES_498709_4
8358/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Meerut
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE(U) E/M Meerut
₹40,000
Yes
19 Jul 2022
6 May 2022
30 May 2022
6 May 2022
28 May 2022
13 May 2022
90 days
Amount
M & L for Cleaning and up keeping of area of MRS by clearing away all grass vegetation, saplings, shrubs, bushes under growth roots and trees not exc 15 cm girth (measured 1 m above the ground level) and removing of rubbish to a distance 50 m away from periphery of boundary wall at a location decided by Engr-in-Charge complete all as specified and directed.
Taking out old aggregate off size up to 30 cm depth from marshalling yard , removing dirt , vegetation , loose soil etc by screening , returning filling the screened aggregate at the same place after spaying chemical for protect vegetation growth all as specified and directed.
Supply and lay Stone river bedded aggregate of 40 mm graded , filled over existing aggregate or over rammed earth for de-routing of green vegetation around the sub station complete all as specified or directed by Engr-in- Charge.
Supply and lay 20 mm size crushed stone aggregated, filled over existing aggregate or over rammed earth for de-routing of green vegetation around the sub station complete all as specified or directed by Engr-in- Charge.
Supply and filling clear dry , course Sand without stone in cable duct/as bedding of aggregate in MRS / sub station all as specified or directed by Engr-In-charge.
M & L for Taking shut down rotating type isolator of 33 KV/1600 Amp capacity for carry out repair like alignment of isolators, blades, arcing horns moving mechanism oiling greasing to isolators gear box assembly tightening renewal of nut and bolts repair to isolator complete all as directed by Engineer- in- Charge Note:- Parts/ components renewed shall be measured and paid separately under appropriate items.
Supply of metallic (brass, alloy) fixed contact set single pole including fixing screwed nuts and washers suitable for air break gang operated switch of cap 1600 amp 3 pole 33KV volts grade complete all as specified and directed.
Supply of metallic (brass, alloy) moving contact rod (blades) set single pole including fixing screwed nuts and washers suitable for air break gang operated switch of cap 1600 amp 3 pole 33KV volts grade complete all as specified and directed.
Supply of metallic (brass, alloy/steel) arcing horns set single pole including fixing screws, nuts and washers suitable for air break gang operated switch of cap 1600 amp 33KV volts grade complete all as specified and directed.
Supply & fix GOD operating handle rod with cover 33 KV grade insulation including hand glove and locking arrangement with 65mm pad lock with two keys complete all as specified and directed by Engr-in-Charge.
Supply of post insulator with GI rod post for holding fixed/moving contact assembly including fixing arrangement suitable for Air break gang operated switch 1600 Amps 33KV volts grade including taking down complete all as specified and directed.
Supply of metallic (brass, alloy) CT,PT, isolator & LA PG clamps having capacity 33000 volt suitable for painther/zebra/Dog ACSR conductor including fixing screwed nuts and washers complete all as directed by Engr-in-Charge. Note : - The contractor has to visit the site to check the existing CT,PT, isolator & LA clamp of 33 KV before purchase/modification of clamp.
Supply & Fix danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with 25 x 3mm thick MS clamps, bolts and nuts of approved size, for HT, 25 x 20 cm size including taking down complete all as specified and directed.
Supply & Fix equipment name plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letters in signal red colour and fixed with 25 x 3mm thick MS clamps, bolts and nuts of approved size 30 x 25 cm and all as directed by Engr-in-Charge including taking down complete.
S & F lighting arrester expulsion type complete with all fittings transmission class discharge capacity 65 KA suitable for 33000 V including taking down old unserviceable lighting arrester.
M&L Disc type ,insulator porcelain, vitreous, brown white or green three disc assembly, 145mm height & 225mm dia ball & socket type for tension with tension clamp for conductor working pressure 33000 volts confirming to IS-1445 including taking down old unserviceable complete all as specified and directed.
M&L pin type, porcelain, vitreous, white or green insulator (HT) 33000 volts grade including one galvanized MS spindle, two GI washer and one GI nut including taking down old unserviceable complete all as specified and directed.
Supply & Fixing breather of Power transformer of size 63 KVA,33000/443 Volts complete with silicajel complete all as specified and directed.
Supply & Fixing breather of Power transformer of size 10 MVA/5 MVA ,33/11KV complete with blue chips silicajel complete all as specified and directed.
M&L Painting of PCC/CI/ check plate cable duct cover of any size and shape with two coats of synthetic enamel paint after preparation of old painted surface colour code of paint shall be as approved by Engineer- in- Charge, complete all as specified and directed.
M & L Painting of steel structure surfaces of CT, PT, LA, SF-6 & isolator, DO etc such as columns, bracing, gantary MS channels, angle iron of any size and shape with two coats of synthetic enamel aluminium paint after preparation of old painted surface complete all as specified and directed.
M&L for preparation of old painted steel surface of any description over 10cm width or girth and applying one coat of synthetic enamel paint of approved colour of 33KV sub stn fencing fixed on compound wall complete all as specified & directed. Note for item No- 20, 21 & 22 : - The contractor has to visit the site to check the existing CT,PT, isolator, LA, transformer & capacitor bank structure for painting of 33 KV sub station.
M&L for Scrapping, cleaning, and preparation of old painted surface of installation iron/wooden door/gate and M&L for painting with two coat of synthetic enamel paint of approved colour complete all as specified and directed by Engineer in charge.
M&L for cleaning and tightning nut and bolt including replacement of unserviceable nut and bolt and spare parts ( nuts and bolt spare parts paid separetly ) applying good qualiity greasing gel of post/disc insulator/LA/CT/PT/ Isolater / breaker/ transformer incomming and out going terminal and complete moveable parts /joints location etc of 33KV switch yard complete all as specified and directed by Engr-in-Charge. ( MRS Bhagat line/Shivaji line/ RR)
Supply, installing, testing and commissioning of air break, gang operated tripal pole switch 800 Amp rating out door horizontal type (ISI marked) mechanically operated, mounting on insulators and frame work with operating mechanism worked from ground level with locking arrengement including Goodraj pattern 65mm pad lock with two keys complete suitable for HT 33 KV, 50 Hz AC supply including taking down and necessary connection including taking down old unserviceable complete all as specified and directed.
S & F Potential transformer 33 KV out door type , electromannetic , single phase, oil filled, Self cooled, having shaped poecelain bushing shaded porcelain bushing as p[er Is; 2099, suitable for operation under the service conditions with protection from sun, rain and dust , shall be oil immersed type provided with Class A insulation. prevent air & moisture from entering the tank. burdens ranging from at least 25 % to 100% of rated burden over to 100% and 190% rated voltage incase of protective cores and a voltage range of 80% to 120% (0.8PF laggeing) complete including taking down old unserviceable complete all as specified and directed.
S & F Curent transformer 33 KV out door type , electromannetic , single phase, oil filled, Self cooled,& hermetically sealed , rated continuous thermal current 120% of rated , rated short time with stand 25 KA (RMS) Acuuracy class 0.5 /5 P10, Burden(VA) 15/15 complete including old unserviceable complete all as specified and directed.
Supply & Fix RCC cable duct cover of size 770mm x310mm x 70mm thick with iron frame and lifting handle complete all as specified and directed by Engr-in-Charge.
Supply & Fix RCC cable duct cover of size 1700mm x310mm x 70mm thick with iron frame and lifting handle complete all as specified and directed by Engr-in-Charge.
M & L for Draining out transformer oil from floor mounted transformer ,CT/PT etc and dehydrating the same using centrifuging machine till its di-elctric strength reach 50 KV and fiiling the same into transformer or CT/PT cpmplete all as specified or directed by Engr-in-Charge.Note:- (i) The transformer oil shall be tested with Transformer Oil Testing Machine for di-electric strength before and after de-hydration of Tr. Oil and kept in record duly sighned by JE , contractor & Engr-in- Charge. (ii) After de-hydration the acidity test of Tr. Oil to be carried out with acidity test kit and record should be kept duly sighned by JE , contractor & Engr-in- Charge. (iii) The Contractor shall arrange his own the electric power rquired for testing/ de-hydration if required.
M&L for Topping Up of Transformer Oil with di-electric strength more than 60 KV complete all as specified or directed by Engr-in-Charge.
Scrapping, cleaning, and preparation of HT 2/3/4 pole structure (Steel tubular pole), steel fitting complete and M & L for painting by one coat of aluminium paint after preparation of the steel surfaces complete all as directed and specified.
Supply and fixing cable jointing kit termination outdoor type for HT 11KV grade cable for end termination joint complete with jointing material (Heat shrink type) and accessories suitable for XLPE armoured aluminium conductor cable and testing after jointing complete of size 50 to 95 Sqmm, 3 core cable complete all as specified and directed. Note:- The end termination joint shall be fixed with in 2 hours from fault timing, otherwise penalty for delay shall be imposed @ 1000 per hrs.
Supply and fixing cable jointing kit termination outdoor type for HT 11KV grade cable for end termination joint complete with jointing material (Heat shrink type) and accessories suitable for XLPE armoured aluminium conductor cable and testing after jointing complete of size 120 to 185 Sqmm, 3 core cable complete all as specified and directed. Note:- The end termination joint shall be fixed with in 2 hours from fault timing, otherwise penalty for delay shall be imposed @ 1000 per hrs.
Supply and fixing cable jointing kit termination outdoor type for HT 11KV grade cable for end termination joint complete with jointing material (Heat shrink type) and accessories suitable for XLPE armoured aluminium conductor cable and testing after jointing complete of size 240 to 300 Sqmm, 3 core cable complete all as specified and directed. Note:- The end termination joint shall be fixed with in 2 hours from fault timing, otherwise penalty for delay shall be imposed @ 1000 per hrs.
S&F heat shrinkable end termination cable jointing kit for XLPE (earthed) 11KV volt grade of size 120 to 185 Sqmm 3 core aluminium conductor cable indoor type complete incl taking out old jointing kit of any make and type all as specified and directed. Note:- The end termination joint shall be fixed with in 2 hours from fault timing, otherwise penalty for delay shall be imposed @ 1000 per hrs.
S&F heat shrinkable end termination cable jointing kit for XLPE (earthed) 11KV volt grade of size 240 Sqmm to 300 Sqmm 3 core aluminium conductor cable indoor type complete incl taking out old jointing kit of any make and type all as specified and directed. Note:- The end termination joint shall be fixed with in 2 hours from fault timing, otherwise penalty for delay shall be imposed @ 1000 per hrs.
S&F heat shrinkable end termination cable jointing kit for XLPE (earthed) 33 KV volt grade of size 284 to 400 Sqmm 3 core aluminium conductor cable outdoor type complete incl taking out old jointing kit of any make and type all as specified and directed. Note:- The end termination joint shall be fixed with in 2 hours from fault timing, otherwise penalty for delay shall be imposed @ 1000 per hrs.
Supply and replacing Dry Chemical type fire extinguisher 5Kgs -1 Nos , Co2 type fire Extinguisher 10 Kgs-01 Nos , gas pressure CTC fire extinguisher -01 No, Fire bukes Ms type 10 ltrs capacity - 03 nos , Fire huch with stick (Bombu)- 01 Nos , Fire padel with Stick (bombu) -01 no, Good quality Robe 150 sqmm - 30 Mtrs complete all as specified and directed.
M&L cross arms, bracing, supports, clamps, and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for holes bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including taking down old unserviceable complete all as specified and directed.. Note : (Insulators to be measured and paid for seperately)
Supply and replace 32mm x 6 mm GI strip as in earth continuity conductor fixed to wall or pole or recess or cheses or burried in ground or drawn in conduit pipe or any other indicated situation for loop earthing etc as required all as directed
Supply and fix 25mm x 4 mm GI strip as in earth continuity conductor fixed to wall or pole or recess or cheses or burried in ground or drawn in conduit pipe or any other indicated situation for loop earthing etc as required all as directed
Earthing complete with galvanized copper plate electrode 60cm X 60cm X 3.15 mm thick buried directly in ground (Earth pit not less than 2.75 Mtrs deep below ground level) with top edge of the plate not less than 1.5 Mtr below normal ground level connected to copper strip 20 x 3 mm size by means of bolts, nuts, check nuts and washer of galvanized iron or of steel, earth lead protected by 40mm dia GI pipe light grade watering pipe 20mm dia GI light grade GI wire messed funnel, alternative layer of charcoal and salt, PCC chamber, recessed for and including RCC cover including all necessary excavation and earth work, earth strips connected to HT/LT equipment testing and made testing point for the earthing, after completion all as specified of MES SSR Pt- I 2020 print, complete all as specified & directed.
M&L for providing and installation of LED Panel sign Board of size 5000mmx1000mm, with capital letters ( MAIN RECEIVING STATION 33/11 KV GRID ROORKEE ROAD GE (U) MEERUT CANTT ) / outer border/multiple colours LED bulbs with PCBs/ drivers/ surge protectors/ terminal box internal wiring pure copper FRLSH complete with Out door type , front side covered visible good quality glass with frame Rectangle box type covered protect of all climates' including MS angle iron 50x5mm thick frame work and standing leg fixed on PCC block. complete all as specified, shown in drawing marked as Sketch 'B' and as directed by Engineer in-Charge.
Supply & Fix earth pit name plate of 1.6mm thick mild steel sheet, vitreous enameld white, with writing of earth pit No, resistance of earth and date of testing, fixed on PCC block complete all as directed by Engr-in-Charge including taking down complete.
Supply & Fix Electric Shock & its treetment chart board with plastic coated and aluminium frame standared size suitable for EHT/HT Sub Stn complete all as specified and directed by Engr-in-Charge.
Supply and Fix First Aid Box with medicine complete all as directed by Engr-in-Charge.
Supply & Fix aluminium frame key board of size 600X600X120mm thick with key hook including locking arrengement with three keys pad lock complete all as directed by Engr-in-Charge.
Supply & Fix digital volt, Amp, frequency display meter and digital watch with date and ambient temprature display complete all as specified and directed.
Supply & Fixing schematic diagram 33/11KV MRS Shivaji line/Bhagat line on board with aluminium frame complete , size as per sample or as specified and directed by Engr-in-Charge.
Supply & Fix Instruction board with aluminium frame of size not less than 1.21x0.9 Mtrs including writing instruction complete all as specified and directed by Engr-in-Charge.
Supply & Fix E-in-C's standing order for protection of persons working on Electrical system board with aluminium frame of size not less than 1.21x0.9 Mtrs including writing instruction complete all as specified and directed by Engr-in-Charge.
M&L aluminium conductor steel reinforces (ACSR) suitable for painther/zebra/Dog straining properly on insulator and binding with aluminium tap/ binding with connectors, jumpers etc of any type and sizes complete all as directed by Engr-in-Charge. Note : 3% conductor shall be measured extra for sagging
Excavation in trenches in soft/loose soil n. exc. 1.5 meter wide and n. exc. 1.5 mtr depth and getting out, including trimming the sides and forming bottom surface to required levels for fixing pole/stay assembly and laying/taking out cables complete all as specified and directed.
Returning, filling including spreading, levelling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
Removing of excavated material (soil) to a distance n. exc. 50 Mtr and dispositing where directed at a level n. exc. 1.50 Mtr above the starting point complete as directed.
M & L Sand cushioning to UG cables (8cm deep before laying of cable and 15 cm deep over the cable). Note :- Punned thickness only will be considered for payment.
Supplying and laying reinforced precast concrete cable covers class EHV, Type I with peak, size 450mm x 230mm x 50mm, ISI marked complete all as specified and directed.
M&L ,XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 33000 volts grade (earthed) cable size of 300 Sqmm, 3 core including laying in trenches, fixing on wall complete all as specified and directed.
Supply and fixing cable jointing kit termination indoor type for HT 33KV grade cable for end termination jointsuitable for XLPE armoured aluminium conductor cable of 300Sqmm size, 3 core complete with jointing material (Heat shrink type) with accessories and testing after jointing complete all as specified and directed.
Supply and fixing cable jointing kit termination outdoor type for HT 33KV (Earthed) grade cable for end termination joint suitable for XLPE armoured aluminium conductor cable of 300 Sqmm size, 3 core complete with jointing material (Heat shrink type) with accessories and testing after jointing complete all as specified and directed.
Maintenance of Existing Earth pit and making Testing point, Suitable replacement of nuts and bolts provn of water line connection ring man type 15 mm GI pipe with 15mm PVC tab each pits including connection from building water tanks complete all as specified and as directed Engr-in - Charge
M&L for Scrapping, cleaning, and preparation of old painted surface of installation VCB/Contol panel / transformer/ LT panel and M&L for painting with two coat of synthetic enamel paint of approved colour complete all as specified and directed by Engineer in charge.
M& Replacement , testing , commissioning of VCB Ratted voltage 12 KV, Rated Current 630 Amps, Frequency 50-60Hz, Insulation level minimum 28 KV/75 KVpk, S/C breaking current 20/40 kA rms complete as per existing VCB same model/ Size /make and comportable to fix in existing panel complete all as specified and directed Engr-in- Charge
Shikha Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .