Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.4 CrAccepted-AOC 123 75 SARESH BAGH KANPUR 208012 UP INDIA | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208012 | ₹5.4 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹6.2 Cr+₹80.8 L (15.0%)Rejected-Finance H NO 30 SECTOR 17 PANCHKULA 2022R6473 | PANCHKULA | PANCHKULA | HARYANA | 2022 | ₹6.2 Cr+₹80.8 L (15.0%) | L2 | Rejected-Finance L2 |
| 3 | Rejected-Technical BLOCK C32 VIKAS NAGAR VIKAS NAGAR NEW DELHI NEW DELHI WEST WEST DELHI DELHI 110059 | WEST DELHI | DELHI | 110059 | - | - | Rejected-Technical affidavit regarding non blacklisting not in order as per approved DNIT |
Tender Value
₹6.0 Cr
EMD Value
₹12.1 L
Closing Date
6 Mar 2026, 1:00 pmClosed
Executive Engineer SWM MC Chd
Room No. 612 6th floor MC Building Sector 17 Chandigarh
Design Supply Installation Testing and Commissioning of 250 KLD capacity Leachate Treatment Plant at Dumping Ground Dadumajra Chandigarh including Trial Run and Operation Maintenance of 24 Months
2025_MCC_89777_3
MCC/EE/SWM/2025/29
Open Tender
Civil Works
Percentage
940 days
Chandigarh
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,000
₹12.1 L
29 May 2026
26 Feb 2026
6 Mar 2026
26 Feb 2026
6 Mar 2026
26 Feb 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Part A Design, Supply, installation, testing & commissioning of 250 KLD Leachate Treatment Plant, Design criteria, all civil, electro-mechanical works to meet the norms for discharge of outlet treated leachate into municipal Sewer line complete in all respect including Trial Run of Minimun period of 02 Months to entire satisfication of EIC | |||||
| 1.01 | SCREEN CHAMBER
Providing and constructing RCC rectangular screen chamber of required size, complete with smooth internal finish, including earthwork excavation, PCC bedding, RCC work in base, walls and slab, reinforcement, shuttering, and providing and fixing sluice gates, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. | 2 | Nos. | 58,000 | ₹1,16,000 |
| 1.02 | OIL & GREASE TRAP
Providing and constructing RCC oil and grease trap of baffled type, rectangular in cross-section, designed for effective surface area of 10 m², including excavation, PCC bed, RCC work, formwork, reinforcement, internal finishing and providing baffles, specifications and directions of the Engineer-in-Charge. | 1 | No. | 2,35,000 | ₹2,35,000 |
| 1.03 | EQUALIZATION TANK CUM MPS
Providing and constructing RCC equalization tank cum main pumping station of required capacity with hydraulic retention time of 8 hours and effective volume of 100 m³, constructed in M-30 grade concrete, rectangular in shape, including excavation, PCC bedding, RCC work in base, walls and slab, reinforcement, shuttering, smooth internal finish, and provision for installation of non-clog submersible sewage pumps, specifications and directions of the Engineer-in-Charge | 1 | No. | 29,44,000 | ₹29,44,000 |
| 1.04 | CHEMICAL REACTION SYSTEM / MIXER FOR EQUALIZATION TANK
Supplying, installing, testing and commissioning MSFRP chemical reaction tank of effective volume 4 m³ for mixing of neutralizing agent, coagulating agent and flocculating agent with effluent, including inlet point, mechanical mixing arrangement or coarse diffuser aeration system, base and structural support, outlet port and access platform, complete as per specifications and directions of the Engineer-in-Charge. | 1 | No. | 4,02,000 | ₹4,02,000 |
| 1.05 | FLOCCULATION UNIT
Providing and constructing flocculation unit of effective volume 20 m³ , rectangular in cross-section, constructed in RCC or MSFRP, including inlet arrangement and gentle mixing system for flocculation, specifications and directions of the Engineer-in-Charge. | 1 | No. | 5,73,000 | ₹5,73,000 |
| 1.06 | PRIMARY CLARIFIER
Supplying, installing, testing and commissioning MSFRP primary clarifier of effective volume 35 m³, rectangular in shape with hopper bottom, complete with tube media, baffles, tube media support structure, inlet and outlet ports and launder for uniform outlet, complete as per specifications, and directions of the Engineer-in-Charge. | 2 | Nos. | 12,91,000 | ₹25,82,000 |
| 1.07 | 7. UASB FEED TANK
Supplying and installing MSFRP/GFS UASB feed tank of effective volume 20 m³, rectangular in cross-section, including all fittings, supports and connections, complete as per specifications and directions of the Engineer-in-Charge. | 1 | No. | 8,20,000 | ₹8,20,000 |
| 1.08 | UASB REACTOR AND COMPONENTS
Designing, supplying, constructing, installing, testing and commissioning UASB reactor system of suitable calculated capacity, constructed in RCC/MSFRP/GFS, rectangular or circular in shape, including reactor, GLSS separator, biogas outlet, gas deflector, effluent inlet and collection system, sludge outlet, sludge pumps, valves and fittings, with all associated components in FRP/HDPE/PVC/SS, complete as per process design, specifications and directions of the Engineer-in-Charge. | 1 | No. | 1,05,33,000 | ₹1,05,33,000 |
| 1.09 | ANOXIC TANK
Providing and constructing anoxic tank of suitable calculated capacity, rectangular or circular in shape, constructed in RCC/MSFRP/GFS, including civil works, internal finishing and appurtenances, complete as per drawings, specifications and directions of the Engineer-in-Charge. | 1 | No. | 16,31,000 | ₹16,31,000 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 22.40 MB
BOQ_111106.xls
BOQ • 0.38 MB
corridate1.pdf
PDF • 0.15 MB
CORRIGENDUM.pdf
PDF • 0.53 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .