Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹26.0 L+₹1.2 L (4.85%)Rejected-Finance ROOM NO D 297 PART III GANESH MURTI NAGAR CUFF PARADE ROAD COLABA MUMBAI 400005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance NOT REASONABLE | |
| 3 | L3₹31.8 L+₹7.0 L (28.3%)Rejected-Finance B 101 SURAJ TOWER MIRA BHAYANDER ROAD OPP SAI PETROL PUMP MIRA ROAD EAST THANE 401107 | MIRA ROAD EAST | THANE | MAHARASHTRA | 401107 | L3 | Rejected-Finance NOT REASONABLE | |
| 4 | L4₹36.4 L+₹11.6 L (46.8%)Rejected-Finance | L4 | Rejected-Finance NOT REASONABLE | |
| 5 | L5₹41.3 L+₹16.5 L (66.7%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L5 | Rejected-Finance NOT REASONABLE |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
15 Jul 2024, 6:00 pmClosed
Saurabh Gupta, EE
GE (W) Colaba, Mumbai
REPAIR AND REPLACEMENT OF FIRE HYDRANTS SYSTEM INCLUDING MS PIPES, FIRE HOSE REEL BOX AND ACCSSORIES AND REPAIR AND MAINT OF DG SETS INCLUDING OTHER CONNECTED ITEMS UNDER GE (WEST), MUMBAI
2024_MES_662060_1
8901/E8
Open Tender
Civil Works
Item Rate
180 days
GE (W) Colaba
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (W) Colaba, Mumbai
₹80,000
Yes
2 Sept 2024
25 Jun 2024
17 Jul 2024
25 Jun 2024
15 Jul 2024
8 Jul 2024
Amount
S&F in repairs detectors complying with and type certified to EN - 45 Addressable type multisensor detector with heat and smoke combination Photoelectric /Optical with base with self built inteligence as per IS: 11360. all as specified and directed
S&F 20 mm dia Gun Metal globe valve crutch or butterfly handle screwed both ends all as specified and directed
Supply, Installation, Testing & Commissioning in repairs of Double door Hose box with painting with necessary fittings as per specification. Details: Fire Hose Cabinets shall be fabricated from 18 gauge MS Sheet with locking arrangement of size of hose cabinet shall be 800 X 600 X 250mm, with 4mm thick glass door, the painting of the hose cabinet shall be as described earlier. Each hose cabinet shall accommodete Hydrant valve. Two nos of 15 metre long hose pipes canvas & One no. of branch pipe with nozzle 63/25. The Fire Hose cabinet will have the legend "FIRE HOSE" painted prominently in the graphic style including taking down existing box all as specified and as directed .
S&F in repairs Butterfly Valve, 80 mm size, both ends flayed with high tensile brass spindle, cast iron body, as per IS-14826 & ISI Marked, including all joints with rubber or fibre board, nuts, bolts, washers all as specified and directed
S&F in repairs Butterfly Valve, 100mm size, both ends flayed with high tensile brass spindle, cast iron body, as per IS-14826 & ISI Marked, including all joints with rubber or fibre board, nuts, bolts, washers all as specified and directed
S&F Sprinkler glass bulb type (Standard response) as per IS:15106/TAC guidelines 68 degree temperature rating pendent type all as specified and directed
Supply, fixing and testing of 1.5 Sqmm x 6 Core Copper Armoured Cable duly saddled in walls, cable glands all as specified and directed
S&F in repairs rubber hose pipe 20mm dia, plain 2 ply rayon braided high pressure all as specified and directed.
S&F in repairs hose reel drums suitable for rubber hose pipe 20mm dia, .
S&F in repairs Factory fabricated MS fire cabinet box as per given design made out flat CRCA of appropriate size and thickness all as directed including two coat of powder coated approved colour synthetic enamel paint over a coat of red oxide primer & fixed on wall with necessary nuts/bolts or welding to existing MS pipe by supporting angle all as specified & directed.
S&F in repairs MS plate in short pieces of appropriate size & thickness required as per site requirement to existing fire cabinet box by means of welding including two coats of synthetic enamel paint (approved colour) over a coat or red oxide primer all as specified & directed.
S&F in repairs canvas fire hose 63mm dia bore 15 metre long confirming to IS Having male/female SS coupling both end all as specified and directed
S&F in repairs SS Nozzle 25 mm bore suitable for 63mm dia canvas pipe all as specified and directed
S&F in repairs fire hydrant stand post including single outlet fire hydrant of 63 mm dia all as specified and directed.
S&F Automatic air release valve 100 mm dia suitable for domestic water including all connecting materials all as specified and directed
M&L in repairs MS front door of size not exc 1.5 m x 1.5m x 2 mm thick including welding locking arrangement including providing pad lock 50mm all as specified and as directed.
M&L for preparation of old painted surface of CI/MS pipe 80/100/150mm dia and applying two coats of synthetic enamel paint (Red colour) including a coat or red oxide primer all as specified and directed.
Servicing of hose reel drums by applying greasing, oiling and making free rotation to hose drum all as specified and directed.
Removing old paint by paint removers and cleaning with scrappers, any number of coats, steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamelled paint over a coat of red oxide primer on fire fighting cubical box fitted inside bldg on each floor. fire chamber cover all as specified and directed
S&F in repairs MS pipes 100mm dia conforming to IS 1239 (Part-I) medium grade with both ends flanged and drilled with standard MS fittings including 02 coats of synthetic enamel paint over one coat of red oxide primer in any length and fixed on walls all as specified and directed in high rise buildings Note : MS flanges including welding to MS pipes and all flanged joints shall be measured and paid separately under respective item of Sch ‘A’
S&F in repairs MS pipes 150mm dia conforming to IS 1239 (Part-I) medium grade with both ends flanged and drilled with standard MS fittings including 02 coats of synthetic enamel paint over one coat of red oxide primer in any length and fixed on walls all as specified and directed in high rise buildings Note : MS flanges including welding to MS pipes and all flanged joints shall be measured and paid separately under respective item of Sch ‘A’
M&L in repairs MS flanges duly drilled including welding work to MS pipes, nuts, bolts, washer all as specified and directed
S&F in repairs SS fire hydrant single acting valve of size 80x63mm all as spcified and directed.
Repair, maintenance, overhauing, testing of Diesel driven Gen set by replacing unserviceable minor spare parts such as gaskets, nuts, bolts, washers and spring including oiling, greasing and Servicing head machining, open and colsing spare part of DG set by replacement of connected fast moving spare parts all as specified and directed of the capacities DG Set 160 KVA Make -Crompton Greaves, Ser No- 1308062206352 (Main Pump house)
All as per item No 24 above but of capacity DG Set 125 KVA Make- Crompton Greaves, (Pump House No 8)
All as per item No 24 above but of capacity DG Set 125 KVA Make - Kirloskar Koel (Assaye Bldg PH )
All as per item No 24 above but of capacity DG Set 100 KVA Make - Greaves, Ser No 130804140555 & 1308042205600 ( Agastya & Menka PH )
All as per item No 24 above but of capacity DG Set 63 KVA Make - Kirloskar, Ser No-H 469470 (MT Area)
All as per item No 24 above but of capacity DG Set 50 KVA Make -Greaves Ser No- 1308041507977 (Brahmaputra )
All as per item No 24 above but of capacity DG Set 40 KVA Make - Kirloskar Koel, Ser No- DS3S119CP156128 & 11340438 (Assaye & Gun House)
All as per item No 24 above but of capacity DG Set 25 KVA Make - Kirloskar, Ser No- 2A0038860 & 2A0043010 (SS NO 4 & Tilottama PH)
All as per item No 24 above but of capacity DG Set Kirloskar 10 KVA Kirloskar AFI Bldg
Diesel Engine fire fighting pump 100 HP Kirloskar Brahmaputra -02 and Augusta - 02 Notes for item No 24 to 33 :- (a) Cost of minor spare parts such as gaskets, nuts, bolts, washers and spring shall deemed to be included in the rate quoted by the tenderer. (b) Lathe work required also deemed to be included in the rate quoted against these items. (c) Spare parts such as fast moving item shall be measured and paid separately under relevant items of this schedule as "Supply only" Items. (d) Repair/ maintenance, servicing and overhaulling shall be carried out through authorized dealer / distributor of manufacturer's of DG Sets.
Repair/maintenance of existing AMF control panel of DG set by replacing the connected items such as leads, copper wire, thimble, Analogue Ammeter, Analogue voltmeter, frequancy meter along with other minor parts required for carrying out maintenance all as directed by Engineer in Charge. Note- Ammeter, Voltmeter and frequancy meter shall be measured and paid separately as supply only items below and labour element involve for replacing the same shall deemed to be included in the rate quoted against these item.
Supply only Analogue Ammeter Class 1, 5 A, 3 phase.of L&T Cat Part No. WDS301FEV00 or equivalent model from make Siemens.
Supply only Analogue Voltmeter Class 1, 3 Ph. of L&T Cat Part No. WDS01FCA00 model from make Siemens.
Supply only Frequancy meter single phase, Class 0.20 of: L&T Cat Part No. WDS121FCF00
Repair/ over hauling of self starter assembly of any type/make/ model including replacement of bearing bushing, washer, bendix pinion, carbon bush as required for proper functioning of the DG set 100 to 160 KVA all as specified and directed
All as per item No 38 above but DG set 40 to 63 KVA
All as per item No 38 above but DG set 10 to 30 KVA Note: (a) Make & SM No of DG Sets shall be as specified against item No 1 here-in-before. (b) Repair works shall be carried out by authorised agent / dealer of DG Sets.
Disconnecting the Exhaust Pipe Line with mufler of DG set from Exhaust Manifold of the Engine and removing the Unserviceable Asbestos Rope from the Exhaust Pipe, Cleaning the Exhaust Pipe and cutting the mufler removing all Carbon Particles Inside including wrapping of existing asbestos rope all as directed by Engr-in-charge for the capacities of DG Sets DG set 100 to 160 KVA
All as per item No 41 above but DG set 40 to 63 KVA
All as per item No 41 above but DG set 10 to 30 KVA
Dismantaling Radiator assembly from DG set Engine from inside and out side , Cleaning and Washing the Radiators & fins by Compressed Air with Chemical Water, removing all dust, etc. from the Radiator and Filling Coolant, re-assemble the same in Original Position with new gaskets, radiator connecting hoses and clamps complete all as directed by Engr-in-charge, for the following capacities DG Sets DG set 100 to 160 KVA Note:- (i) Coolant shall be measured and paid seperatly under relevnt items of these schudule. (ii) Asbestos rope shall be measured and paid separately under relevant items of these schedule. (iii) Repair works shall be carried out by authorised agent / dealer of DG Sets. (iv) Make & SM No of DG Sets shall be as spesified against item No 24 to 33 here-in-before.
All as per item No 44 above but DG set 40 to 63 KVA
All as per item No 44 above but DG set 10 to 30 KVA
Disconnecting the fuel tank including Inlet/Outlet Connections of the DG sets DG set 100 to 160 KVA and cleaning the tank properly and removing all dusts, mud, etc. and refixing the fuel tank and Inlet/Outlet Pipe connections in orginal position all as directed by Engr-in-charge.
All as per item No 47 above but DG set 40 to 63 KVA
All as per item No 47 above but DG set 10 to 30 KVA
M&L for scraping of old painted surfaces from DG sets and preparation of old painted surfaces for repainting complete body of DG set including alternator, with one coat of superior quality synthetic enamel paints of colour as per existing for engine, alternator, base frame by spray painting including writing SM/MES NO all as directed by Enginner -in- charge for DG set of capacities DG set 100 to 160 KVA
All as per item No 50 above but DG set 40 to 63 KVA
All as per item No 53 above but DG set 10 to 30 KVA 0
M&L for Rewinding of starter armature complete for capacities of DG sets DG set 100 to 160 KVA With super enamelled copper winding wire including taking out old unserviceable winding all as directed by Engr-in-charge.
All as per item No 53 above but DG set 40 to 63 KVA
All as per item No 53 above but DG set 10 to 30 KVA Note: (a) Make & SM No of DG Set shall be as specified against item No 24 to 33 here-in-before. (b) Repair/ maintenance & servicing shall be carried out through authorized representative of manufacturer's of DG Sets.
Repair / over hauling of automatic/manual, Governor assembly of any make/type/model complete including calibration and replacement of spare parts as required to make the governor 100 % trouble free complete all as directed by Engr-in-Charge of the DG set 100 to 160 KVA
All as per item No 56 above but DG set 40 to 63 KVA
All as per item No 56 above but DG set 10 to 30 KVA Note: (a) Make & SM No of DG Set shall be as specified against item No 24 to 33 here-in-before. (b) Cost of spare parts shall deemed to be included in the rate quoted by the tender.
Repair/ over hauling, servicing of dynamo assembly of 12 volt of any make/type and including rewinding of armature and field coil including replacement of bearing/bushing, carbon bush etc all as required to make dynamo 100% serviceable all as directed by Engineer-in-Charge.
Repair/ over hauling, servicing of alternator for battery charger of 12 Volt Battery of any make / type / rewinding of armature and field coil including replacement of bearing / bushing etc and make the alternator 100% serviceable all as directed by Engineer-in-Charge.
S&F in repair Indicator lamp (AC/DC) LED type for as per existing fitting
S&F in repairs Current transformer coil range 300/5 A ,15 VA/Cl-1
Repair/ servicing of alternator of any make/type/model including grinding/polishing of slip rings assembly cleaning and re-tensioning of carbon bush holder including replacement of carbon bush for the alternators of DG Sets, DG set 100 to 160 KVA
All as per item No 64 above but DG set 40 to 63 KVA
All as per item No 64 above but DG set 10 to 30 KVA, Note: (a) Make & SM No of DG Set shall be as specified against item No 24 to 33 here-in-before. (b) Cost of spare shall demand to be included in the rate quoted by the tender
Repair/ servicing of FIP ( fuel injection pump) of any make/type/model including grinding/polishing including all ring washer and connected accessories of DG Sets : DG set 100 to 160 KVA
All as per item No 67 above but DG set 40 to 63 KVA
All as per item No 67 above but DG set 10 to 30 KVA, Note: (a) Make & SM No of DG Set shall be as specified against item No 24 to 33 here-in-before. (b) Cost of spare shall demand to be included in the rate quoted by the tender
Taking out defective automatic voltage regulator (AVR) of DG set (alternator side) and supply and fix new automatic voltage regulator (AVR) including necessary connection, testing and cable work all as directed by Engr-in-charge for the DG Set of capacity DG set 100 to 160 KVA
All as per item No 70 above but DG set 40 to 63 KVA
All as per item No 70 above but DG set 10 to 30 KVA, Note: (a) Make & SM No of DG Set shall be as specified against item No 24 to 33 here-in-before.
S&F in repairs timer for AMF Panel suitable for 10 to 160 KVA
S&F in repairs AMF Controller for AMF Panel suitable for 10 to 160 KVA
S&F in repairs Conntector for AMF Panel suitable for 10 to 160 KVA
Repair, maintenance, Major overhauling, testing of Diesel driven Gen set by replacing unserviceable Major spare parts following spare part etc including oiling, greasing and Servicing head machining, open and colsing spare part of DG set by replacement of connected fast moving spare parts complete 10 to 160 KVA all as specified and directed.
Supply only Piston Assembly for DG set 63 to 160 KVA as specified against item No 24 to 33 here-in-before.
All as per item No 77 above but Piston Ring set.
All as per item No 77 above but Linner Assembly.
All as per item No 77 above but Gasket set.
All as per item No 77 above but 'O' ring kit/Liner O ring.
All as per item No 77 above but Head gasket.
All as per item No 77 above but Main bearing.
All as per item No 77 above but C R Bearing.
All as per item No 77 above but Front oil seal.
All as per item No 77 above but Rear oil seal.
All as per item No 77 above but Valve (inlet/Exhaust).
All as per item No 77 above but Valve seal
All as per item No 77 above but Valve guide.
All as per item No 77 above but Valve steam seal.
All as per item No 77 above but Can bush.
All as per item No 77 above but Connecting Rod bush.
All as per item No 77 above but Thrust washer.
All as per item No 77 above but Hose pipe Kit
All as per item No 77 above but Hose clamp set
All as per item No 77 above but Flexible pipe set
All as per item No 77 above but high pressure pipe set.
All as per item No 77 above but Leak off pipe.
All as per item No 77 above but Oil filter set.
All as per item No 77 above but Diesel filter set.
All as per item No 77 above but Air filter set.
All as per item No 77 above but Oil pressure gauge.
All as per item No 77 above but Oil temperature gauge.
All as per item No 77 above but Fan belt.
All as per item No 77 above but Flexible pipe set
All as per item No 77 above but High pressure pipe set.
All as per item No 77 above but Leak Off pipe.
All as per item No 77 above but Oil filter set for 10 to 50 KVA
All as per item No 77 above but Diesel filter Set for 10 to 50 KVA
All as per item No 77 above but Air filter set for 10 to 50 KVA
All as per item No 77 above but Fan belt.
All as per item No 77 above but Belt tensioner.
All as per item No 77 above but Lube oil pump.
All as per item No 77 above but Exhaust blow.
All as per item No 77 above but Stop solenoid.
All as per item No 77 above butCopper washer set.
Supply and filling Engine Oil (20 W 40)
Supply and filling Coolent
M&L for line voltage monitor relay (LVM ) suitable for 10 to 160 KVA DG set
Supply and fixing sealed Lead - Acid battery 12 Volts 120 Ah suitable DG Set with connected wiring all as specified and directed.Make- Exide
Supply and fixing sealed Lead - Acid battery 12 Volts 150 Ah suitable DG Set with connected wiring all as specified and directed.Make- Exide
Supply, lay in trenches, floors, fix on wall/pole, passing through pipes LT UG cable, 1100 volts grade, PVC/ XLPE insulated, with multistranded aluminium conductors, armoured with galvanised steel wire or tape, gland, lugs of size 95 Sq.mm 3.5 core , confirming to IS specifications :-
Excavation in trenches not exc 1.5mtr. In depth and not exc 1.5mtr in width and getting out in soft/ loose soil for laying of cable all as specified and directed.
Returning, fillling in trenches, spreading, levelling, watering and well ramming in layers not exc 25cm thick all as specified and directed.
Removing excavated material/ surplus soil and depositing where directed at a distence not exc 50 m at a level not exc 1.5 m from starting point all as specified and directed.
Supply lay/spread in trenches, river sand, clean, including spreading, levelling, punning for laying /cushioning of cables all as specified and directed.
Supply lay in trenches fly ash bricks, old size sub class “B” disignation for cable protection all as specified and directed.
S&F onload change over 200 Amps 415 Volts, 50 HZ complete with sheet metal enclosure all as specified and directed.
S&F GI tubing 50 mm dia light grade under road, on pole floor and on wall for cable protection all as specified and directed.
M&L electrical earthing complete with GI plate Electrode of size 60 Cm X 60 Cm X 6.3 mm thick burried directly in ground vertically at a depth not less than 2.25 mtr. below normal ground level, with top edge of earth plate at a depth not less than 1.5 m below normal ground level , connected to GI earth strip 32mm x 6mm earth lead by means of bolts, nuts and washers of galvanised iron, earth lead strip protected by means of 32 mm bore dia light grade GI pipe up to switch board/ panel board, all as specified and shown in MES schedule Electrical Plate No:-3 of SSR Part I, including excavation and earth work in any type of soil , PCC 1 : 2 : 4 type B1 in chambe , RCC 1:2:4 type C1 40 mm thick cover slab with 6 mm dia MS bars at 100 mm centre to centre both ways, with 6 mm dia MS hook, Charcoal dust, salt, funnel for watering complete and testing the earth resistence and writing on the chamber by paint all as specified and as directed.
S&F in repairs 32x6mm galvanised iron strip with saddles and fixing screws, etc. for roof conductors and down conductors above ground all as specified and directed by Engr-in-Charge.
GANGAJAL
Saviour Security Systems
Shetty Construction Co
Shree Ayyappa Engineering
cooltech engineering services
Bidder Name
cooltech engineering services
Shetty Construction Co
Shree Ayyappa Engineering
Saviour Security Systems
GANGAJAL
Minal Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .