Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.0 LAccepted-Finance | L1 | Accepted-Finance LOWEST | |
| 2 | L2₹22.8 L+₹1.8 L (8.42%)Accepted-Finance | L2 | Accepted-Finance NOT LOWEST | |
| 3 | L3₹24.9 L+₹3.8 L (18.2%)Accepted-Finance | L3 | Accepted-Finance NOT LOWEST | |
| 4 | L4₹26.4 L+₹5.4 L (25.7%)Accepted-Finance | L4 | Accepted-Finance NOT LOWEST |
Tender Value
₹25.1 L
EMD Value
₹50,100
Closing Date
20 Dec 2021, 3:00 pmClosed
CHIEF CONSTRUCTION ENGINEER R AND D SM
CHIEF CONSTRUCTION ENGINEER R AND D SM MAHANAGAR PALIKA MARG CIVIL LINES P B NO 86 NAGPUR 440 001
PROVISION OF TWO NOS BOREWELL AT CDEF, DRDE, BORKHEDI SITE, NAGPUR
2021_DRDO_659859_1
80349 CCE SM BOREWELL BRKD
Limited
Civil Works
Item Rate
120 days
NAGPUR
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
CHIEF CONSTRUCTION ENGINEER R AND D SM
₹50,100
Yes
18 Jan 2022
4 Dec 2021
21 Dec 2021
4 Dec 2021
20 Dec 2021
13 Dec 2021
6 Dec 2021 - 9 Dec 2021
Amount
Boring / drilling bore well of 300mm dia for casing / strainer pipe, by suitable method prescribed in IS:2800 (part I), including collecting samples from different strata, preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per for the job, all complete as per direction of Engineer-in - charge, beyond 90 meter & upto 150 meter depth below ground level. All types of soil and as per direction by Engineer-in-Charge
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2mm) mild steel threaded and socketed / plain bevel ended pipe (type A) of 200 mm nominal size dia, conforming to IS:8110, of reputed and approved make, having wall thickness not less than 5.40mm, including painted with outside surface with two coats of anticorrosive bituminous paint of approved brand and manufacture, including hire & labour charges, fittings and accessories, all complete, for all depths, as per direction of Engineer-in-charge. Make : Tata / Jindal.
Providing and fixing M.S. clamp of 200 mm dia to the top of casing / housing pipe of borewell as per IS:2800 (part-I), including necessary bolts & nuts of required size completed.
Providing and fixing 200mm dia threaded mild steel cap or spot welded plate to the top of bore well housing / casing pipe, removable as per requirement, all complete for borewell.
Providing and fixing Bail plug / bottom plug of 200 mm dia to the bottom of pipe assembly of tubewell as per IS : 2800 (part-I)
Supply, installation, testing and commissioning of vertical Submersible Pump set 24 stage, 12.5 HP, 3 Phase, 4 wire, 430/440 Volts, 50 Hz, having Head 223 mtr, LPH 5000 the pump set shall be comprised with S.S. impeller, SS shaft, CI casing, complete with mounting brackets etc., including star delta starter of 12.5 HP submersible pump sets, requisite length submersible copper conductor cable of size 3 x 4 Sqmm, nylon rope of required size and length for anchoring of submersible pump sets etc complete all as specified and directed by Engineer - in-charge. Make : KSB / Crompton / Kirloskar / Grandfoss
Supply and laying G.I. pipes heavy grade 65mm dia with G.I. fittings for (column pipe) with all accessories etc complete. Make : TATA / Jindal.
Supply and Laying of 50mm GI Pipe with medium grade with necessary GI fittings including trenching, refilling and removal of surplus soil of any type with all accessories etc. complete. Make : TATA / Jindal.
Supply, Fixing & Testing of Cast Iron sluice valve (SV) having CI wheel, SS spindle and necessary check nuts, bolts washers, rubber insertion sheet etc complete all as specified and directed for following sizes. Make : Kirloskar / Audco / Zoloto
Supply, Fixing & Testing of Cast Iron Non Return Valve (NRV) of size 50mm with all connected material etc. Complete all as specified and directed. Make : Kirloskar / Audco / Zoloto
Supply, laying and testing of 3.5C x 50 sqmm 1.1KV grade XLPE insulated armoured aluminium conductor under ground cable, in built up cable trench/ already laid RCC hume pipe or on cable tray with all installation materials. When the cable is to be laid in ground, the same shall be laid at a depth of 750mm below ground level including excavation and refilling of earth after cables are laid, providing protection with sand and bricks at sides and top and cable route markers at every 15mtr. interval and also at the turnings. The cable shall conform to IS 7098
Earthing with GI earthing plate 600mm x 600mm x 6mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement, watering pipe of 2.7 mtr long funnel and wire mesh etc., with charcoal / coal and salt as required) alongwith all connected civil works etc complete all as specified and directed.
Providing and fixing 32mm x 6mm GI strip on surface or in recess for connection etc as required.
Providing and fixing 8 SWG dia GI wire on surface or in recess for loop earthing as required.
Construction of valve chamber of size 0.75 x 0.75 x 0.75 mtrs including necessary civil works, brick work, plastering, loacking arrangement with fabricated MS sheet 2mm thick as cover plate etc complete all as specified and directed by Engineer-in-Charge.
Conducting geological survey in the respective area for identification of borewell locations including the borewell report conducting test at site. The geological survey can be get done by Geological survey of India or any other approved agency by the dept.
SRI SAI BALAJI AGENCY
SHRAYA ASSOCIATES
Vaibhav Laxmi Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .