Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 CrAccepted-AOC | ₹13.2 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹13.5 CrRejected-Finance 143 RAM GALI HAJINDER NAGAR II KANPUR UP PIN 208007 | KANPUR NAGAR | UTTAR PRADESH | 208007 | ₹13.5 Cr | L2 | Rejected-Finance REJECTED SINCE NOT L1 |
| 3 | L3₹14.7 CrRejected-Finance | ₹14.7 Cr | L3 | Rejected-Finance REJECTED SINCE NOT L1 |
| 4 | L4₹14.9 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹14.9 Cr | L4 | Rejected-Finance REJECTED SINCE NOT L1 |
Tender Value
₹12.3 Cr
EMD Value
₹9.4 L
Closing Date
12 May 2020, 6:00 pmClosed
HQ CE(AF) ALLAHABAD
HQ CE(AF) ALLAHABAD
WORK SERVICES FOR CONSTRUCTION OF NEW ATC BUILDING AT AF STN DARBHANGA
2019_MES_306475_1
958911/E8/3
Open Tender
Civil Works
540 days
DARBHANGA
Please referr tender documents
8 documents required · 8 mandatory
₹3,000
Yes
GE AF BHITA
₹9.4 L
Yes
3 Jun 2020
14 Dec 2019
16 May 2020
14 Dec 2019
12 May 2020
9 Mar 2020
21 Dec 2019 - 28 Dec 2019
Amount
SCHEDULE A PART I (BUILDING WORKS)
Construction of ATC building (with corridor) and Garage for Crash fire (along with main building) complete all as specified and as shown in drawings
Construction of Car parking garrage for 07 Nos cars including apron complete all as specified and as shown in drawings.
Construction of Car parking garrage for 06 Nos cars including apron complete all as specified and as shown in drawings.
Construction of Scooter shed type A for 20 scooters complete all as specified and as shown in drawings.
Construction of Semi UG Sump 100000 Ltr capacity complete all as specified and as shown in drawings.
Construction of Pump house for fire fighting complete all as specified and as shown in drawings.
Construction of Sub station building complete all as specified and as shown in drawings.
Sch A Part II (INTERNAL ELECTRIFICATION)
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION as listed in Sch ‘A’ Part II.
Sch A Part III (INTERNAL WATER SUPPLY)
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY" as listed in SCHEDULE ‘A’ PART- III .
Sch A Part IV (EXTERNAL ELECTRIFICATION)
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION as listed in Sch ‘A’ Part- IV .
Sch A Part V( EXTERNAL WATER SUPPLY)
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY, as listed in Sch ‘A’ Part-V.
Sch A Part VI (ROAD/PATH/CULVERT)
Lump sum price worked out by the contractor for ROAD/PATH/CULVERT, as listed in Sch ‘A’ Part- VI.
Sch A Part VII (AREA DRAINAGE)
Lump sum price worked out by the contractor for AREA DRAINAGE, as listed in Sch ‘A’ Part- VII.
Sch A Part VIII (SEWAGE DISPOSAL)
Lump sum price worked out by the contractor for SEWAGE DISPOSAL,as listed in Sch ‘A’ Part- VIII.
Sch A Part IX SECURITY FENCING
Lump sum price worked out by the contractor for SECURITY FENCING, as listed in Sch ‘A’ Part- IX.
Sch A Part X SITE CLEARANCE, EXCAVATION AND EARTH WORK
Lump sum price worked out by the contractor for SITE CLEARANCE, EXCAVATION AND EARTH WORK, as listed in Sch ‘A’ Part- X.
Sch A Part XI (Miscellaneous Items of B/R and E/M)
M&L for flame proof point wiring with FRLS PVC insulated, unsheathed cable with multi stranded copper conductor 2x1.5 sqmm single core 1100 Volt grade confirming to IS: 694 and including surface mounted drawn through ERW steel coduit not less than 19mm dia including conduit and conduit accessories fixed on wall /ceiling incliding 1x1.5 sqmm PVC insulated unsheathed multi stranded copper conductor FRLS single core (green colour ) as earth continuity conductor up to common earth and connected to common earth dolly for two light point /fan control by one switch. Note :- (i) Flame proof switch shall be measured and paid separately All conduit accessories such as bends, Elbows, Tee, reducers, junction box etc deemed to be included in the rate quoted.
S&F Flame proof rotory switch with termination box in LM-6 enclosed in and including aluminium body enclosure with threaded cover and toggle action switch operated by shrouded knob single pole 16 Amps, 250 V, 2P + Earth with double direct entries through way switch including 20 mm dia ERW hreaded rigid steel conduit( duly approved and tested by CMRI Dhanbad) complete all as specified & directed. Make:- Sudhir/Baliga/Shyam
S & F flourescent tube light 1X 16/20 watt flame proof type suitable for LED lamp FLP-WP made of aluminium alloy LM6, with bipin holder, connector block, LED tube etc complete with all accessories prewired & including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make:- Crompton cat No. EXTN1LT8-16/20 5700K ,Sudhir cat No. FF/OA/1271 or equivalent make of Baliga
Bringing earth form out side MD land and spreading in layers n. exc 25cm thickness including watering and rolling with 8 to 10 power roller complete all as specified and directed. Note:- The rate quoted against this item shall also be deemed to include cost of earth, excavation and transportation upto site from any lead.
M&L for Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete with LED lamp 5 watt, 230V all as specified and directed by Engr-in-Charge.
Supply and Fixing ceiling fan with down rod, fan conector/ fan hook, 1400mm sweep, minimum BEE 3 star rated 240 V AC with 3 Blade and connecting up including provn of three core PVC insulated multi strandee flexible copper conductor cable of size 1.5 sqmm copper wire form connector to fan of length not less than 0.5mtr. all as specified & directed.
Supply and fixing Exhaust fan of 300mm sweep (heavy duty), minimum BEE 3 star rated single phase 230 V AC , 900 RPM , with louvered shutters including mounting frame , nut , bolts, washers, fasteners etc with suitable size hole for exhaust fan and connecting exhaust fan to ceiling rose including provn of three core flexible copper cable of size 1.5 sqmm not less than 0.5 mtr long for connection complete all as speicified.
Supply and fixing Exhaust fan of 300mm sweep totally enclosed type (heavy duty), minimum BEE 3 star rated single phase 230 V AC, 900 RPM, with louvered shutters including mountig frame, nut, bolts, washers, fasteners etc with suitable size hole for exhaust fan and connecting exhaust fan to ceiling rose including provn of three core flexible copper cable of size 1.5 sqmm not less than 0.5 mtr long for connection complete all as specified.
S & Fix wall/surface mounted type LED light fitting complete with LED lamp of 1x20/22 watt (4 ft ), extruded, aluminium heat sink provided for efficient heat dissipation & integrated electronic driver complete with all accessories internally pre-wired and including connecing up with twin core twisted flexibe copper conductor cable. Make:- Philips Cat No-BN 550 WLED 20-6500, Havells Cat No. LHEWEBP7PLIN1W020, Wipro Cat No. LL 20-221-XXX-60-XX.
S & Fixing wall/surface mounted type LED light fitting for mirror light complete with LED lamp of 1x 9/10 (2 ft), extruded aluminium heat sink provided for efficient heat dissipation & integrated electonic driver complete with all accessories internally pre-wired and includig connecting up with twin core twisted flexible copper conductor cable. Make:- Havells Cat No.- LHEWEBP7PLIN1W010 , Philips cat No. BN 021 LED 10S - 6500 PSU GR S1 or Crompton cat No. LCTL - 9 CDL.
Supply and fixing LED street light fittings 1x20/25 watt complete fitting having pressure dia cast aluminium housing with heat resistant toughened glass & IP 65 protection including fixing arrangement comprising of suitable size dia of GI pipe 40mm dia light grade 1.5 mtr long bend at 120 fixed to wall with 2 Nos clamps made of FI 50x6 mm and necessary nut , bolts and washers complete with all accessories duly connection with three core flexible copper cable all as spcified and directed. Make:- Philips,Cat No.- BRP020 1x10 LED, Wipro Cat No - LR01- 018-XXX-WH-XX , Havells Cat No- LHETAXU7PA6J025,Bajaj Cat No.BCLST25W, CG Cat No. LSTO-25-CDL .
S & F surface mounted type LED round type down lighter 15/18 watt, 5700K, 230V, in powder coated white finish with integrated electrionic driver complete internally prewired and duly connection all as specified & directed. Make : Havels Cat No. LHEAAGP71A2W012, CG CAT NO LCDSPL-R - 18 CDL, Philips Cat No. SM 251C LED 165 - 6500 PSU WH.
S&F ceiling mounted type LED light fitting suitable for 36 watt, 230V,Size (2x2) feet, in powder coated white finish with integrated LED driver complete internally prewired and duly connection all as specified & directed. Make:- Havels Cat No. LHECDIL7PN1W036,CG CAT NO LCPL-36-CDL, Philips Cat No. RC380B LED 36S-6500G4 L60 W60 PSU OD.
Submain wiring with two runs of 2x4 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLS 1100 volts grade cable drawn through and including PVC concealed conduits heavy duty grade ISI marked 25mm dia (External) with conduit accessories and one run of single core PVC(green colour) insulated but unsheathed multi stranded copper conductor of size 1x4 Sqmm 1100 volts grade cable as earth continuity conductor complete all as specified and directed. Note: Two runs of 4 Sqmm , one run of 4 Sqmm earth conductor and one run of conduit shall be measured and paid as one metre length of unit.
Submain wiring with four runs of 6 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLS 1100 volts grade cable drawn through and including PVC concealed conduits heavy duty grade ISI marked 32mm dia (External) with conduit accessories and Two runs of 6 Sqmm single core PVC insulated but unsheathed multistranded copper conductor 1100 volts grade cable as earth continuity conductor complete all as specified and directed.. Note: Four runs of 6 Sqmm , two run of 6 Sqmm earth conductor and one run of conduit shall be measured and paid as one metre length of unit. .
S&F factory made epoxy powder coated distribution board SPN 8 way 240 Volt (SPN MCB DB) with double door (IP-43 protection) fabricated from CRCA sheet as per OEM specification and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail , earth bar and cable ties for cable management , top and bottom removable gland plates with knockouts complete all as specified and directed .
S&F factory made epoxy powder coated Distribution Board TPN 4 ways 415 volt grade (TPN MCB DB) with double door with acrylic top cover (IP-43 protection) fabricated from CRCA sheet as per OEM specification and fixed flush to wall and suitable for universal mounting and including 200Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management , top and bottom removeable gland plates with konckouts complete all as specified and directed.
S&F factory made epoxy powder coated Distribution Board VTPN 4 ways 415 volt grade (VTPN MCB DB) with double door with acrylic top cover (IP-43 protection) fabricated from CRCA sheet as per OEM specification and fixed flush to wall and suitable for universal mounting and including 200Amp copper bus bar, neutral bar,standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with Knockouts compete all as specified and directed.
S&F MCCB 125A, 4 pole, 415V volt 16KA complete all as specified and directed.
S&F MCB TPN 63A, 415V volt C curve 10KA complete all as specified and directed.
S&F MCB TP 63A, 415V volt C curve 10KA completer all as specified and directed.
S&F MCB SPN 32 Amp, 240V volt C curve 10KA complete all as specified and directed.Make - Legrand /L&T/ABB
S&F MCB SP 6- 32 Amps 240V volt C curve 10KA, complete all as specified and directed. Make - Legrand /L&T/ABB
S&F telephone socket one module with all fixing acessories complete all as specified and directed.
S&F computer socket one module with all fixing accessories complete all as specified & directed.
S&F modular type metal flush boxes 3 Module complete with modular plate & blanking plate for unused way etc for fixing of telephone socket & LAN cnnection.
Supply,laying,commissioning and testing of 100 mm dia centrifugally cast ductile iron pressure pipe with socket and spigot end class " K-9" confirming to IS : 8329:2000 (Latest version) blast furnace slag cement with portland cement properties suitable for push on joint with inside cement mortar lining, external metalic zink coating followed by finishing layer of black bitumen coating duly ISI marked complete all as specified and directed.
Supply,laying,commissioning and testing of horizontal mounting monoblock submersible pump set having suction of 100 mm dia, 5 HP capacity, coupled to submersible type electric motor suitable for three phase, 415 V, 50 Hz supply comprising of (i) Submersible pump (ii) Submersible motor (iii) riser / column pipe line as required upto 15 mtr in length (iv) Air line valve (v) Sluice valve, butter fly valve and reflux valve as required at site (vi) Flat copper conductor submersible cable of suitable capacity upto 15 Mtr length (vii) Suitable DOL/ star delta starter etc complete all as specified & directed.
S&F of DI pipes special like bends ( Any type, radius and angle) taper any type (straight,bend,increasing,decreasing or double socket etc) Tee pieces single branch "Y" junction double branch, cross, coller, caps and plug all as specified and directed
M&L for consturction of brick masonry pit chamber of following internally size 600 mm x 600 mm x 600mm with angle iron frame of sizes 40mmx40mmx6mm thick mild steel plate cover painted with two coats of sythentic enameled paint over a coat of red oxide primer after preparation of surface incl locking arrangement and necessary excavation and earth work 80mm thick PCC (1:3:6) type C1 using 20 mm graded stone aggreagate over 100 mm thick hard core using broken brick in foundation brick work in cement mortar (1:6) and 15 mm thick cement plaster in cement mortar (1:4) in internal surface of walls and outside upto 150 mm deep below ground level complete all as specified and directed at site.
M&L for consturction of brick masonry pit chamber of following internally size 900 mm x 900 mm x 900mm with angle iron frame of sizes 40mmx40mmx6mm thick mild steel plate cover painted with two coats of sythentic enameled paint over a coat of red oxide primer after preparation of surface incl locking arrangement and necessary excavation and earth work 80mm thick PCC (1:3:6) type C1 using 20 mm graded stone aggreagate over 100 mm thick hard core using broken brick in foundation brick work in cement mortar (1:6) and 15 mm thick cement plaster in cement mortar (1:4) in internal surface of walls and outside upto 150 mm deep below ground level complete all as specified and directed at site.
Material and labour for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia, PN-6 PE-80 grade conforming to IS 4984 includng necessary fittings suitable for 0.6 mpa working pressure complete all as specified and directed..
Supply and errection of steel tubular pole swaged type 410-SP 55 (LT 11.00 mtr long pole) complete confirming to IS: 2713 complete with CI base plate pole cap bolt nuts & screw with cast iron base plate, pole cap, mild steel bolt, nuts and screws complete all as specified including consisting of following works:- (a) Excavation in trenches not exceeding 1.5 mtr wide & 1.83 mtr deep for pole foundation & getting out in soft/loose soil, returning filling in the excavated of soil after fixing the pole in foundation ramming earth around in layer not exceeding 25 cm thick and disposal of surplus soil to a distance not exceeding 50 mtrs complete all as specified and directed. (b) M&L for PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) in foundation 900mmx600mm cross section and planting depth 1.5 mtr for concrete encasing the pole upto GL complete all as specified and directed. (c) M&L for providing PCC 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) for plinth block/collar above GL 500mm high and 450mm dia complete all as specified and directed. (d) M&L for painting of pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coat of aluminum paint over a coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto the height of 1.5mm above plinth block. (e) M&L for writing letter or figures (Block Roman, Italic as Indian) with thick synthetic enamel paint of apprised shade not exceeding 5 cm height including numbering of pole complete all as specified and directed. (f) Painting of coping with cement based paint all as directed. NOTE : Manufacture's test certificate will be produced before execution work. Note:- Excavation, earth work and PCC for erection of poles shall be measured and paid separately under respective item of Sch 'A' Part.
Supply and errection of steel tubular pole swaged type 410-SP 31 (LT 9.00 mtr long pole) complete confirming to IS: 2713 complete with CI base plate pole cap bolt nuts & screw with cast iron base plate, pole cap, mild steel bolt, nuts and screws complete all as specified including consisting of following works:- (a) Excavation in trenches not exceeding 1.5 mtr wide & 1.57 mtr deep for pole foundation & getting out in soft/loose soil, returning filling in the excavated of soil after fixing the pole in foundation ramming earth around in layer not exceeding 25 cm thick and disposal of surplus soil to a distance not exceeding 50 mtrs complete all as specified and directed. (b) M&L for PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) in foundation 900mmx600mm cross section and planting depth 1.5 mtr for concrete encasing the pole upto GL complete all as specified and directed. (c) M&L for providing PCC 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) for plinth block/collar above GL 500mm high and 450mm dia complete all as specified and directed. (d) M&L for painting of pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coat of aluminum paint over a coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto the height of 1.5mm above plinth block. (e) M&L for writing letter or figures (Block Roman, Italic as Indian) with thick synthetic enamel paint of apprised shade not exceeding 5 cm height including numbering of pole complete all as specified and directed. (f) Painting of coping with cement based paint all as directed. NOTE : Manufacture's test certificate will be produced before execution work. Note:- Excavation, earth work and PCC for erection of poles shall be measured and paid separately under respective item of Sch 'A' Part.
Supply and erection of non- linear resistance type lightening arrestor suitable for 3 phase 11 KV overhead line with rated voltage at 9 KV (RMS) with nominal discharge current rating with 5 KA complete with galvanised clamping arrangment, GI nuts, bolts and washer complete all as specified & directed.
Supply, installation, commissioning and testing of switch air break gang operated HT 11000 volts grade triple pole with 09 insulators, 200 amp capacity current rating complete with dropout fuse assembly with fuse carrier fuse elements mounted on insulators and steel frame mechanically operated mechanism from ground level consisting of rod 25 mm bore GI pipe, light grade of suitable length worked from ground level with locking arrangement fixed with flat iron clamp 50x6 mm and MS channel of suitable size and length for fixing GOD including bolts, nuts and washers complete all as specified and directed.
Supply and laying in trenches or passing through pipe/fixed to wall/pole and duct etc HT XLPE insulated, screened with extended semi conducting compound in combination with copper tape, inner sheath or PVC tape, galvanized flat steel strip armoured and overall PVC outer sheathed conforming to IS-7098 electric cable heavy duty with aluminium conductor 11000 volts, earth grade including jointly and testing of cross sectional area 95 sqmm x 3 core complete all as specified.
Supply and install HT 11 KV outdoor type drop out fuse assembly ISI marked CPRI tested factory assembled on a hot dip galvanised steel cross arms suitable for mounting on steel poles alongwith mounting bracket with all contacts in ETP grade copper and silver plated all terminals in brass duly plated for connection with copper or aluminium conductor with fuse tube holder having an outer layer of fiber glass and inner layer of bone liner for effective extinguishing of arc, and with outer of fuse tube having a layer of UV resistant paint easily replaceable fuse carrier tubes, the hinged mechanism made of brass duly electroplated, the spring loaded stainless steel flipper arranged toggle mechanism ensuring a wiping action during arc interuption process, with a safely latch to percent fuse carrier from droping due to vibration, rated voltage - 12 KV Rated continuous current - 100 Amps, No. of poles - 3 Nos. Rated frequency - 50 Hz, Maximum normal current of fuse base - 200 Amps, Maximum normal current of fuse holder- 100 Amps , Power frequency with stand voltage across the isolating distance - 32 KV, power frequency withstand voltage to Earth and between poles- 28 KV, lightening voltage withstand test across isolating distance - 85 KV peak, lightening voltage withstand test across phase to earth - 75 KV breaking current at 15 KV - 8 KA, mounting angle to vertical axis - 20 degree, total creep age distance 320 mm, protected creep age distance 84 mm complete alongwith two set of drop out fuse of 20 Amps current capacity complete all as specified & directed.
M&L for shifting & transportation of existing transformer step down 11 KV/0.433 KV of any capacity upto 315 KVA capacity from store yard of GE(AF) Bihta to the site of work at Darbhanga and installation, connecting up, testing and commissioning of servecable indoor/ outdoor type transformer, including carrying out minor repair such as replacing electroplated filteration of transformer oil and topping up of transformer oil ( as required to achieve desired level and die- electric strength of transformer oil), painting of transformer external surface with spray painting with two coats of synthetic enamel paint complete all as specified & directed.
Supply, installing,testing& commissioning of factory assembled Silent Diesel Engine driven generating set including suitable AMF panel, 1500 RPM of capacity 160 KW (200 KVA), 3 Phase, 4 wire, 415 Volt, 0.8 PF complete with control panel including integrated powder coated accoustic enclosure as per CPCB regulations and duly certified by agencies / labs designated by CPCB for noise and sound pollution level etc floor mounted including PCC foundation as per manufacturer's instruction complete all as specified & as directed. (A) DIESEL ENGINE (MAKE- KIRLOSKAR/ CROMPTON GREAVES/ CUMMINS/ ASHOK LEYLAND) as per IS- 10001/10002 of required capacity for driving 160 KW (200 KVA) alternator multi cylinder, vertical type, 4 stroke, water cooled, elctric start confirming to IS for continuous running capable for taking 10 % overload for one hour complete. Consisting of followings:- (i) Radiator (ii) Radiator fan with guard (iii) Flywheel with starter ring (iv) Air cleaner oil bath type (v) Vacuum Indicator (vi) Electronic Governor class IA (vii) Exhaust Silencer (viii) Fuel filter & fuel hoses (ix) FIP (fuel injection pump) (x) Fan & water (pump assembly) (xi) Lub oil filter & pump (xii) Electric starting system with battery charging alternator and axial type starter motor including adequate number of high capacity maintenance free lead acid battery, 120 AH, 12 Volts, DC as per manufacturers requirement including interconnecting cables/leads with terminals complete with starting/stopping switch, voltmeter, etc - 01 Set (xiii) Engine Safety shut down system against low lub oil pressure & high water pressure (xiv) Oil filter (xv) Engine maintenance manual with spare parts list (xvi) Suitably designed accoustic enclosure as per CPCB regulatories.
(B) ENGINE INSTRUMENT PANEL digital type indicating the following:- (i) Starting switch on/off (ii) Water temp gauge (iii) Hour meter cum RPM indicator (iv) Lub oil pressure gauge (v) Lub oil temperature gauge (vi) Battery charging meter (vii) Safety alarm against high water temp and lub oil pressure
(C) ALTERNATOR (MAKE :- KIRLOSKAR/CROMPTON/STEMFORD) shall be self excited, self regulated, brush less for 160 KW (200 KVA) continuous operation at the speed of 1500 RPM at 415 volts, 50 Hz, three phase 4 wire system with advance electronic voltage regulator to ensure high voltage accuracy with ± 1%, with class H insulation and SPDP enclosure directly coupled with engine through flexible coupling and conforming IS 13364 complete - 01 No (D) Common fabricated base frame for engine & alternator made from structural channel, jerk proof placed in & including PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) foundation including adequate number of suitable anti-vibration pads as per the recommendatio of the manufacture (NOTE - Cost of suitable size of PCC foundation and platform raised 30 CM above ground level shall deemed to be included in the unit rate quoted by the contractor) (E) Bottom mounted steel fuel tank fabricated out of 14 SWG MS sheet of capacity not less than 12 hrs continuous operation, inside canopy, with fuel level gauge, drain plug, locking arrangements, etc, with & including GI pipe connections duly laid as per engineering practice complete all as specified & directed. (F) CONTROL PANEL Control panel suitable for 160 KW (200 KVA) DG set shall be of standard type available with the DG set with the following accessories as under :- (i) Starting switch ON/OFF -01 No (ii) Water temperature gauge (iii) Hour meter cum RPM indicator (iv) Lub oil pressure gauge (v) Lub oil temperature gauge (vi) Battery charging meter
Supply installation, testing and commissioning of 11KV, 3-Phase, 50HZ, 400 Amps, 250 MVA, 13.1KA Vaccum circuit breaker, extensible indoor type with motorzed and manual spring charging facility breaking capacity 13.1 KA for 1 second, SCADA compatible, having pad lock, provision for earth switch complete wtih all necessary accessories and standard fittings (e.g Relays, CTs, PTs, Power pack, spring charging motor, trip coil, ammeter, voltmeter, indication lamps etc., all as specified, required at site and as directed, comprising of followings:- (i) 11KV, 3 Phase, 50 HZ, 400 Amps, 13.1 KA, VCB having short circuit current withstand capacity not less than 13.1 KA for 3 seconds, having manual and automatic charging mechanism, by DC/Universal motor suitable for 110 Volts/230 Volts AC/DC or as per OEMs recommendations, shunt trip coil, indication lamp, on off switch padlock, provision for earth switch padlock, provision for earth switch etc complete all as specified and directed (ii) Double core and double ratio type dry type current transformers (CTs) of ratio 100/50%+5 Amps, suitable for 11KV, 3 Phase, 50 HZ, having 15 VA burden or as per OEMs recommendation with 0.5 class accuracy for metering and %P10 accuracy for protection -01 Set of three. (iii) Dry type 11KV/110 Volts potential transformer (PTs) suitable for 11KV, 3 Phase, 50 HZ, connected to bus bar class-1 accuracy of 100 VA burden or as per OEMs recommendation complete all as specified and directed - 01 Set. (iv) LED type indiction lamps for circuit breaker open (OFF) - "GREEN", circuit breaker close (ON) "RED" circuit breaker trip "YELLOW", spring charge "BLUE" trip circuit healthy with push button and R-Y-B phase indication lamp complete all as specified - 01 set. (v) Trip supervision relay.
M&L earthing complete with GI earth plate electrode 600x600x6.00mm thick buried directly in ground vertically in pit of depth not less than 2.25 mtr below normal ground level with top edge of the earth plate not less than 1.50 mtr below normal ground level connected to galvanized iron strip 32x6mm as earthing lead by means of bolts, nuts, check nuts and washers of brass connected, including earth test point of galavanized iron/ steel of size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil incl 40mm GI tubing light grade and necessary fitting for protection of GI strip incl laying of charcoal, dust and common salt PCC (1:2:4) type CI using 20mm graded stone aggregate earth pit with 40x40x6mm MS angle iron frame RCC cover 40mm thick (1:2:4) type B-1 using 12.5mm graded stone aggregate reinforced with 8mm dia round bar@ 75mmC/C both way with MS handle 12 mm dia plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally .PGL funnel with wire mesh 20 mm dia GI pipe for watering complete all as shown on electrical plate No 3 of SSR Part-1 2009 and connected in earth incl testing complete all specified and directed.
S&F integral LED street light luminaries minimum 100 watts with high power LEDs made of pressure die cast aluminium body, extra clear flat glass protector, integral control gear, IP 66 for both optical compartment and control gear compartment, 100 W, PF › 0.95 , THD › 20%, surge protection - 4 KV, CRI › 70%. The fixture should have lumens maintenance of at least 70% at 50000 hours. The driving current for LED should be maximum 500 mA ± 10%. The luminous efficacy of fixture should be at least 90 lumens per watts including GI light grade pipe bracket of suitable shape 1.5 metre long, fixed with GI clamps and connecting cable TC 2.5 Sqmm copper from light fitting to over head line/ UG cable box complete all as specified & directed. Make:- Havells cat No. LHETAXUJPN6J100 or equivalent in Bajaj, Philips, Wipro, Crompton
S&F Junction box Factory made size 250mm x 150mmx100mm made from 16 guage steel sheet powder coated complete with 4 Nos aluminium busbar of 40 amp fixed on porecelain supports with hinged cover and locking arrangement fixed to bottom of the electric pole by means of clamp of MS flat iron 25X6 mm with bolts and nuts including one no single pole 6 Amps MCB complete all as specified directed.
Supply, installation, testing and commissioning of fire alarm main control panel microprocessor based addressable inteligent type and compatable with detector for communication to detectors and response indicators together with mimic diagram made on Auto CAD and pasted on Acrylic sheet with data logging facility and 2X16 character LCD, conforming to IS : 2189 of capacity from 99 detector and 99 modules upto 200 detectors and modules complete with PA based evacuation system and suitable for 415 volt three phase, 50 Hz having its own standby power backup supply with batteries, battery charger etc complete. The panel should also have an auto dialling facility and potential NO & NC contacts and a 80 watts PA amplifier. The panel should have a capacity of not less than 4 zones complete all as specified & directed.
Supply, installation, testing and commissioning smoke cum heat detector complying with and type certified to EN 54 adressable type, microprocessor based, programable intelligent type, multisensor detector with heat and smoke combination with base including necessary connection complete all as specified & directed
Supply, installation, testing and commissioning addressable response indicators having flashing green LED and Red LED for indication of fire and continuous monitoring including necceessay connection to pin point location of fire complete and blinking facility complete all as specified & directed
Supply and fix addressable type manual call point with break glass type compatible with main fire alarm control board microprocessor based as per IS-2189 and including chain hammer facility complete all as specified & directed
Supply, installation, testing and commissioning of fire alarm sounders / siren elctronic type horizontal single stage continuous normal operation for at least 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of +5 DB, 500 Mtr range with PA system with 6 watt speaker including necessary connection complete all as specified & directed
M&L for concealed wiring for the fire alarm system using two runs of single core FRLS PVC insulated, unsheathed stranded copper conductor cable of size 1.5 Sqmm of voltage rating upto 1100 volts one run of copper cable FRLS PVC insulated unsheathed as earth continuity conductor drawn in and including concealed medium grade MS conduit with standard accessories complete all as specified & directed
Supply, installation, commissioning and testing of split air conditioner (5 star invertor type Air- conditioner) of 1.5 TR, (4500 Kcal/Hr) Capacity complete with cordless remote control unit and built-in-air-ionizer and plasma filter for better air quality. Indoor unit Hi wall mounted type, suitable for 230 Volts, 50 Hz, Single phase AC supply and capable of performing the function as cooling, air circulating and filtering. The air conditioners shall be complete with automatic variable speed / variable tonnage air conditioners depending upon heat load to be provided with electronic thermostat as per IS 11338 of 1985. Outdoor unit of the air conditioner shall be fitted with discharge cooled type rotary / scroll compressors operating on Non - CFC refrigerators ( like R410A or equivalent) with suitably rated capacitor start electric motor equipped with overload protection and mounted on resilient mountings for quiet operations. . The casing of the indoor unit shall be made of ABS/ HIPS/GS. The control box of indoor unit shall withstand flame- retardant test to grade V-O and as per UL 94. The filter packs provided shall be washable. Remote cordless control with LCD/LED display shall be provided on indoor unit and on handset. Overall power factor of the unit shall not be less than 0.85 at operating conditions. The invertor type air conditioner shall corelate to the values as specified by the OEM and latest IS/BIS certification as mentioned in the table 2.2 of the gazette of India notification number 024(E) dated 05 Jan 2010 issued by Central Govt of India.
Supply, installation, commissioning and testing of split air conditioner (3 star invertor type Air- conditioner) of 2 TR, (6000 Kcal/Hr) Capacity complete with cordless remote control unit and built-in-air-ionizer and plasma filter for better air quality. Indoor unit Hi wall mounted type, suitable for 230 Volts, 50 Hz, Single phase AC supply and capable of performing the function as cooling, air circulating and filtering. The air conditioners shall be complete with automatic variable speed / variable tonnage air conditioners depending upon heat load to be provided with electronic thermostat as per IS 11338 of 1985. Outdoor unit of the air conditioner shall be fitted with discharge cooled type rotary / scroll compressors operating on Non - CFC refrigerators ( like R410A or equivalent) with suitably rated capacitor start electric motor equipped with overload protection and mounted on resilient mountings for quiet operations. The casing of the indoor unit shall be made of ABS/ HIPS/GS. The control box of indoor unit shall withstand flame- retardant test to grade V-O and as per UL 94. The filter packs provided shall be washable. Remote cordless control with LCD/LED display shall be provided on indoor unit and on handset. Overall power factor of the unit shall not be less than 0.85 at operating conditions. The invertor type air conditioner shall corelate to the values as specified by the OEM and latest IS/BIS certification as mentioned in the table 2.2 of the gazette of India notification number 024(E) dated 05 Jan 2010 issued by Central Govt of India.
Supply, installation, commissioning and testing of split air conditioner (4 star invertor type Air- conditioner) of 3 TR, (9000 Kcal/Hr) Capacity complete with cordless remote control unit and built-in-air-ionizer and plasma filter for better air quality. Indoor unit Hi wall mounted type, suitable for 230 Volts, 50 Hz, Single phase AC supply and capable of performing the function as cooling, air circulating and filtering. The air conditioners shall be complete with automatic variable speed / variable tonnage air conditioners depending upon heat load to be provided with electronic thermostat as per IS 11338 of 1985. Outdoor unit of the air conditioner shall be fitted with discharge cooled type rotary / scroll compressors operating on Non - CFC refrigerators ( like R410A or equivalent) with suitably rated capacitor start electric motor equipped with overload protection and mounted on resilient mountings for quiet operations. The casing of the indoor unit shall be made of ABS/ HIPS/GS. The control box of indoor unit shall withstand flame- retardant test to grade V-O and as per UL 94. The filter packs provided shall be washable. Remote cordless control with LCD/LED display shall be provided on indoor unit and on handset. Overall power factor of the unit shall not be less than 0.85 at operating conditions. The invertor type air conditioner shall corelate to the values as specified by the OEM and latest IS/BIS certification as mentioned in the table 2.2 of the gazette of India notification number 024(E) dated 05 Jan 2010 issued by Central Govt of India.
Note for item No. 1.85, 1.86 & 1.87 The installation shall include mounting/fitting indoor units at respective location. Laying refrigerant piping of upto 6 Mtr length and connecting both the units after drilling bores in the wall, putting PVC sleeve and finishing as required. The thickness of copper tubing shall not be less than 0.70 mm. Suction pipe shall be insulated with expanded polythene foam not less than 5 mm thick. Laying 15 mm drain out the condensate water being formed in the condensing unit. Leak testing of the entire system, Charging refrigerant gas in the unit and suitable electric wiring between indoor and outdoor unit upto 6 Mtr length and upto switch within 3 Mtr of location of indoor unit.
Supply, installation, testing and commissioning of water cooler electric driven (Single Phase) having approximate storage capacity of 80 Liters and nominal cooling capacity of 40 Liters per hour, body made up of non -corrosive stainless steel material, complete comprising of water storage tank of approx 80 Liters capacity made of hygienic stainless steel having lockable lid with proper rubber sealing for protection against ingress of dust, dirt and insects, thermal insulation of water tank with PUF material, Energy efficient hermetically sealed compressor working on Non-CFC, Non toxic, Non- Inflammable, environment friendly refrigerant R-32 or R-22 with suction gas cooled, Equipped with overload protector, relay and other accessories, condenser fan - noiseless propeller type with thermostat for automatically control of temperature with 15 Amps 3 pin plug top, 3 core cable and earth terminal, inlet water connection with 15 mm flexible pipe having female not on both ends with efficient float valve for control of water, water outlets with two 15 mm dia push type cocks, drainage arrangment complete all as specified and directed.
Supply and erecting and testing evaporative air cooler (desert cooler) with GI / fibre body, 230 / 250 Volts, 50 cycles, comprising of fan, pump, drip proof motor, filter pads, confirming to IS: 3315 and having 5000 cubic meter per hour cooling capacity, complete with 5 metre long 3 core cable and 5A hand shield type three pin top and marking Serial No. and date of erection complete. Notes: (a) Material of exhaust fan for inlet air :- Exhaust fan shall be complete with motor and ISI marked to IS: 2312 : 1967 with amendment No. 1,2 & 3. Cooler pump shall be ISI marked and confirming to IS: 11951 : 1987 with amendment No. 1 to 4. Exhaust fan shall be of 900 mm ( 06 pole motor) and shall have single speed. (b) Cooler: Cooler shall be suitable for operation on 230 volts +/- 10%, single phase, 50 Hz AC supply. Pump set shall confirm to IS: 11951 - 1987 with amendment No. 1 to 4. The coolers shall be complete with fan, motor, filter pads, water pump etc. Fan motor will be of 1400 RPM (4 poles) and shall have three speeds. Filter panel, front grill and top of the cooler body shall be made of 0.8 mm galvanised steel sheet. The sump tank and rest of the body shall be made of 1.2 mm thick galvanised steel sheet. The galvanised steel sheet shall be ISI marked and shall have zinc coating not less than 120 gm/Sqm and shall conform to IS: 277-2003. All internal surface including inside of the tank, fan blades, motor body, pump, pump body and frame shall be painted with water resistant paint confirming to IS: 9863-1981 with amendment No. 1.
S&F wall mounted digital display voltage stablizer 5 KVA for automatic voltage correction, single phase, naturally air cooled indoor type designed for input voltage 170V to 250V with output voltage stabilized at 230 V with accuracy of +/- 2.5% with high/low voltage cut off with facility of time delay with overload and under voltage protection complete all as specified & directed.
S&F wall mounted digital display voltage stablizer 3 KVA for automatic voltage correction, single phase, naturally air cooled indoor type designed for input voltage 170V to 250V with output voltage stabilized at 230 V with accuracy of +/- 2.5% with high/low voltage cut off with facility of time delay with overload and under voltage protection complete all as specified & directed.
S&F industrial type, SPN and earth plug socket, 250 V, 10/16 Amps with steel enclosure and one MCB SP 16 Amps complete all as specified & directed.
S&F industrial type, SPN and earth plug socket, 250 V, 20/32 Amps with steel enclosure and one MCB SP 32 Amps complete all as specified & directed.
S&F industrial type, TPN and earth plug socket, 250 V, 63 Amps with steel enclosure and one TP MCB 63 Amps complete all as specified & directed.
Submain wiring with four runs of 10 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLS 1100 volts grade cable drawn through and including PVC concealed conduits heavy duty grade ISI marked 32mm dia (External) with conduit accessories and Two runs of 10 Sqmm single core PVC insulated but unsheathed multistranded copper conductor 1100 volts grade cable as earth continuity conductor complete all as specified and directed.. Note: Four runs of 10 Sqmm , two run of 10 Sqmm earth conductor and one run of conduit shall be measured and paid as one metre length of unit. .
Supply, installation, testing and commissioning of electric motor driven fire fighting pump set horizontal end suction centrifugal type confirming to IS:12469:1988 with CI casing bronze impeller and stainless steel shaft mounted on heavy duty bearing suitable for continuous operation with range of operation 0% to 150% of rated capacity suitable for automatic operation for fire fighting complete for delivery of water at the rate of 2280 LPM and running at 2850/2900 RPM so as to maintain a minimum pressure 7.0 Kg /Sqcm at the end of delivery side of pump with pressure gauge and bypass arrangment for periodic testing of working of fire fighting pump set, squirrel cage induction motor suitable for 440 V, 3 Phase, 50 Hz complete with and including common base plate of MS channel and foundation (RCC/PCC) all as per manufacturer instruction/ design and vibration resistant complete all as specified & directed by Engr-in-charge and specified below:- (a) The pump shall be horizontally mounted, split casing, centrifugal complete for delivery of above mentioned discharge against desired mentioned head so as to ensure a minimum presure at the highest and farthest outlet at the specified flow complete with necessary connection for fixing strainers, succsion and delivery pipe, valve, NRV, pressure gauge, pressure switch including bypass arrangement for periodic testing of the working of the pump set as well as testing of automation with required length and size of medium class GI pipe and control valves for proper completion of work. The pump shall be capable of giving 150% of rated discharge at head not less than 65% of rated head. The pump shall be provided with mechanical seals. The impeller shall be enclosed type and accurately balanced dynamically. The pump casing shall be of cast iron, impeller shall be of bronze and shaft shall be of stainless steel.
(b) Sqirrel cage, TEFC induction motor suitable for 415V, 3 phase having IP 55 protection and class 'B' insulation for the above pump and flexible coupling with the pump. The motor shall be rated for continuous duty and shall have HP rating necessary to driven the pump at 150% of its rated discharge at 65% of rated head. (c) Common base plate of fabricated mild steel channel or cast iron type. (d) Suitable cement concrete pump foundation and vibration clamping arrangemet as required with foundation bolts, anti vibrant pads, washer etc. (e) pressure switch for automatic operation including necessary wiring upto control panel.
Supply, installation, testing and commissioning of fire pump diesel engine driven fire fighting pump set horizontal end suction centrifugal type confirming to IS:12469:1988 with CI casing bronze impeller and stainless steel shaft mounted on heavy duty bearing suitable for contineous operation with range of operation 0% to 150% of rated capacity suitable for automatic operation for fire fighting complete for delivery of water at the rate of 2280 LPM and running at 2850/2900 RPM so as to maintain a minimum pressure 7.0 Kg /Sqcm at the end of delivery side of pump with pressure gauge and bypass arrangment for periodic testing of working of fire fighting pump set, squirrel cage induction motor suitable for 440 V, 3 Phase, 50 Hz complete with and including common base plate of MS channel and foundation (RCC/PCC) all as per manufacturer instruction/ design and vibration resistant complete all as specified & directed by Engr-in-charge and specified below:- (a) The pump shall be horizontally mounted, split casing, centrifugal complete for delivery of above mentioned discharge against desired mentioned head so as to ensure a minimum presure at the highest and farthest outlet at the specified flow complete with necessary connection for fixing strainers, succsion and delivery pipe, valve, NRV, pressure gauge, pressure switch including bypass arrangement for periodic testing of the working of the pump set as well as testing of automation with required length and size of medium class GI pipe and control valves for proper completion of work. The pump shall be capable of giving 150% of rated discharge at head not less than 65% of rated head. The pump shall be provided with mechanical seals. The impeller shall be enclosed type and accurately balanced dynamically. The pump casing shall be of cast iron, impeller shall be of bronze and shaft shall be of stainless steel.
(b) Sqirrel cage, TEFC induction motor suitable for 415V, 3 phase having IP 55 protection and class 'B' insulation for the above pump and flexible coupling with the pump. The motor shall be rated for continuous duty and shall have HP rating necessary to driven the pump at 150% of its rated discharge at 65% of rated head. (c) Common base plate of fabricated mild steel channel or cast iron type. (d) Suitable cement concrete pump foundation and vibration clamping arrangemet as required with foundation bolts, anti vibrant pads, washer etc. (e) pressure switch for automatic operation including necessary wiring upto control panel.
Supply,install,test and comissioning of electric motor driven jockey pump set horizontal end suction centrifugal type confirming to IS: 12469: 1988 with CI casing, bronze impeller and stainless steel shaft mounted on heavy duty bearing suitable for automatic operation with non over loading power characteristics for frequent start / stop operation of fire fighting complete for delivery of water at the rate of 180 LPM and running at 2850/2900 RPM so as to maintain the pressure 3.5 Kg/ Sqcm with pressure gauge, squirrel cage induction motor suitable for 440 V, 3 phase, 50 Hz complete with and including all accessories and common base plate of MS channel and foundation (RCC/PCC) all as per manufacture instruction/design and vibration resistant complete all as directed by Engineer-in-charge.
Supply and laying cutting to required length, jointing, testing and commissioning MS Electric resistance welded plain end pipe of size 150mm nominal bore (External 3 layers coating with polyethylene) with heavy duty manufactured as per IS 1239, 1990 alongwith all fittings/specials such as bends, tees, collars, reducers etc including jointing with pipes and laid in trenches
Supply and laying cutting to required length, jointing, testing and commissioning MS Electric resistance welded plain end pipe of size 100mm nominal bore (External 3 layers coating with polyethylene) with heavy duty manufactured as per IS 1239, 1990 alongwith all fittings/specials such as bends, tees, collars, reducers etc including jointing with pipes and laid in trenches
Supply, install test and commissioning of 150 mm dia cast iron sluice valve or butter fly valve of class PN-1.6, both ends flanged with iron wheel head and stainless steel spindle, long body type, jointed and tested complete all as specified and directed .
Supply, install test and commissioning of 100 mm dia cast iron sluice valve or butter fly valve of class PN-1.6, both ends flanged with iron wheel head and stainless steel spindle, long body type, jointed and tested complete all as specified and directed .
Supply, install, test and commissioning of 150 mm dia cast iron non return valve (NRV), both ends flanged, jointed and tested complete all as specified and directed.
Supply, install, test and commissioning of 100 mm dia cast iron non return valve (NRV), both ends flanged, jointed and tested complete all as specified and directed.
Supply and fix strainer for suction pipe of 150 mm dia complete all as specified and directed
Supply and fix air release valve with all accessories for fire fighting pumps and fire fighting system as required complete and all as directed.
Supply, install, test and commissioning of weather proof standard hose cabinet outdoor type suitable for accommodating singleheaded hydrant valve made of not less than 16 SWG MS Sheet having central opening glazed door (4mm thick clear glass) including necessary locking arrangement with handle for housing two Nos, 15 meter long fire hose pipes, branch pipe and hydrant valve as required including painting (one coat of primer and two coats of fire red colour). The cabinet shall be mounted on suitable raised brick masonry platform or on MS Angle iron frame as directed by Engineer-in-Charge. The words "FIRE" to be painted on the box complete all as specified and directed. Make : Getech/Minimax/Newage.
Supply, install, test and commissioning of weather proof standard hose cabinet outdoor type suitable for accommodating singleheaded hydrant valve made of not less than 16 SWG MS Sheet having central opening glazed door (4mm thick clear glass) including necessary locking arrangement with handle for housing two Nos, 15 meter long fire hose pipes, branch pipe and hydrant valve as required including painting (one coat of primer and two coats of fire red colour). The cabinet shall be mounted on suitable raised brick masonry platform or on MS Angle iron frame as directed by Engineer-in-Charge. The words "FIRE" to be painted on the box complete all as specified and directed.
Supply, install, testing and commissioning of single headed Yard Hydrant/Landing valve with 63mm female coupling stantaneous outlet ISI marked IS:5290 including cost of MS flanges washer and provision of 80 mm dia MS pipe for tee, cutting, welding etc., at all in any height complete all as directed .
Supply, install, test and commissioning of 63/20 mm dia branch nozzle of gunmetal ISI marked IS:903 with all material complete all as specified & directed.
Supply, install, test and commissioning of hose reel drum with RRL hose pipe 15m long and 63mm gun metal male female coupling complete at all height and all as specified & directed.
Supply, install, test and commissioning of hose reel drum with RRL hose pipe 30m long and 63mm gun metal male female coupling at all height complete all as specified & directed.
Supply, installation, testing and commissioning of fire briged inlet connection including sluice valve and providing cutting, welding, elbows, tees, flanges, nuts, bolts & making connection for fire briged system as per IS:336 all as specified & directed.
Supply, Installation, testing and commissioning of fire brigade drawout complete all as specified & directed.
Supplying and fix Pressure guage of range 0-10 Kg. Including all required accessories and all as specified and directed.
Supply and fixing universal/differential type pressure switch of required calibration for Automatic operation of fire fightig system complete with all accessories.
M&Lfor construction of brick masonry valve pit chamber of internal size 900mm X 900mm X 750 mm with angle iron frame of size 40mm X 40mm X 6 mm thick mild steel plate cover painted with two coats of synthetic enameled paint over a coat of red oxide primer after preparation of surface including locking arrangement and necessary excavation and earth work, 80 mm thick PCC (1:3:6) type C-1 using 20 mm graded stone aggregate over 100 mm thick hard core using broken brick in foundation, brick work in cement mortar (1:6) and 15 mm thick cement plaster in CM(1:4) in internal surface of walls and outside upto 150 mm deep below ground level complete all as specified & directed at site.
Supply, installation, testing and commissioning of Microprocessor based programmable type Main Control Panel fabricated form 2mm CRCA sheet powder coated with necessary microprocessor bassed programable type inteligent solid state ON/OFF relay, contractor, automatic phase sequence corrector, single phase preventor and switchgear of suitable rating installed in pump house for fire fighting pumps (main pump, jockey pump, standby pump) complete and all as directed by Engineer-in-Charge with details given below :- (i) 300 Amp copper bus-bar suitable for 3 phase and neutral fixed on porcelain insulator-01 set, ammeter with CT, auto/manual switch necessary interlocking arrangement, control wiring all wiring and earthing from panel to motor single phase preventors one for each pumps internal wiring 32 TPN MCB for battery charging name plate engraved complete all as directed by Engineer-in-Charge. (ii) Microprocessor based programmable type solid state intelligent relay for automatic ON/OFF operation of fire fighting pumps as per logic of standard fire fighting procedure/practice and as per relavent latest IS and as approved by GE including suitable rating of heavy duty contactors, suitable transducers, sensors, control wiring etc., complete and all as specified and directed. (iii) MCCB (incomer) 200amp, adjustable type, FP, 25KA (ics=100% ocu) - 01 No Make: Legrand/ABB/Siemens. (iv) Star-delta starter of suitable rating for main fire fighting pump, standby pump and jocky pump with all required accessories complete. (v) MCCBs (outgoing) of suitable rating for main fire fighting pump, Jocky pump and standby pump with breaking capacity not less than 25KA (ics=100% icu).
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recessed or chases or burried in ground or drawn in counduit pipe or fixed to pole or any other indicated situation for loop earthing etc., as required 4mm dia GI wire (For connecting electrical equipments to earth grid) complete all as specified and directed.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recessed or chases or burried in ground or drawn in conduit pipe or fixed to pole or any other indicated situation for loop earthing etc as required 32x6 GI Strip (For connecting electrical equipments to earth grid) complete all as specified and directed.
S&F Air vessel fabricated from MS Shell 12mm suitable for a working pressure of 10 Kg/Sqcm complete with mounting pedestal dished ends 10mm of 35mm dia and 1.50mtr height complete with 1 No 25mm dia gate valve, 1 No pressure gauge, 1 No 25 mm dia gun metal and other accessories as required complete all as specified.
Supply, installation, testing and commissioning of fire extinguisher CO2 type ISI marked of 4.5 Kg complete all as specified and directed.Make:- Minimax/G Tech/ Cease Fire.
Supply, installaion, testing and commissioning of fire extinguisher ABC powder type of ISI marked 6.0 Kg complete all as specified and directed. MAKE:- Minimax /G Tech /Cease Fire.
S&F Air termination single pointed copper rod 12mm dia 300mm long single pointed at top end mounted on suitable length GI pipe with two Nos of MS clamps of suitable size and connecting up with aluminium strip complete with clamps and all accessories all as specified and directed.
M&L of aluminium strip 25x3.15 mm with saddles and fixing screw for roof conductor and down conductor above ground fixed to roof by means of stand of hold fast placed on PCC block and fixed to wall/parapet on insulated saddle complete all as specified and directed. Note: Aluminium strip on the roof conductors shall not be directly fixed/touching on the roof surfaces.
M&L for test point terminal block made of gun metal/phosphorus bonze size 75x75x25mm drilled and screwed including 03 Nos 8mm long hex. Head screw complete.
M&L of GI strip 32x6mm burried in 150mm below normal ground level including connecting up with earth electodes plate of earthing on both ends with GI nuts, bolts and washers in addition to welding and also included excavation earth work and returning filling in levelling compacting etc complete all as specified and directed.
M&L for GI pipe light grade 40mm bore for earth conductor protection fixed under road/floor along wall etc. complete all as specified and directed.
M&L for 40 mm thick insulated PVC wall lining consisting of 2 mm thick wood grain printed PVC sheet duly fitted into the wall all as specified & directed..
M&L for 5 mm thick PVC sheet fillet of width 35 mm for wall panelling including fixing on to wall to make PVC frame all as specified & directed..
Provn of cubical work station of size 6 feet x 2.25 feet X 4.25 feet for 04 officer made out of prelaminated boards as per specifications & TP. (a) Prelaminated board both side (MDF) 19 mm size 8feet x 4feet - 01 No. (b) Prelaminated board both side (MDF) 18 mm size 8feet x 4feet - 02 No. (c) Prelaminated board both side (MDF) 8 mm size 8feet x 4feet - 02 No. (d) Handle for Drawer / CB -08 Nos (e) Lock for Drawer / CB -08 Nos (f) 2 feet LED tube light complete - 02 Nos (g) Tape roll -01 No. (h) Screw Black - 01 Packet (j) Screw SS full thread 25 mm -02 Pkts (k) Screw SS full thread 19 mm -02 Pkts (l) Screw SS full thread 35 mm -02 Pkts (m) Fevicol SH -01 Kg (n) Wheels -08 Nos (o) Solution -01 Kg (p) Nails 3 inch -03 Kg (q) Nails 4 inch -02 Kg (r) Channel for drawer 18 inch -04 Nos (s) 15 Amp switch socket combination -2 Nos (t) 5 Amp switch socket combination -2 Nos (u) 5 amp switch for tube light -02 Nos (v) PVC copper cable 1.5 Sqmm -90 RM (w) PVC copper cable 2.5 Sqmm -90 RM (x) Insulation tape 10 M -01 Roll (y) Piano hinges 2feet X 4 inch -04 Nos (z) Casing and caping 1.5 inch X 2 M -04 Nos
Construction of Brick masonary, septic tank of 100 user capacity all as specified and shown on drawings including earth work in any type of soil 100 mm bore cast Iron inlet and outlet pipes upto 3 mtr from outer face of wall, including CI Tee, sluice valve chamber, RCC slab and precast RCC manhole covers, reinforcement and CI vent pipes etc complete all as specified and as per drawing.
Construction of soak well 2.4m dia and 4.5m effective depth including earth work in any type of soil foundation concrete in PCC honey comb brick work solid brick work in cement mortar, RCC slab and precast manhole covers including reinforcement, with brick bats filling complete all as specified and shown on drg.
Constr of steel gate 5.00m wide with RCC pillars including excavation in any type of soil, RCC 1:2:4 type B-1 in foundation & two coats of synthetic enamel paint over a coat of red oxide primer on all steel surfaces and fabrication complete all as specified and shown on drg.
M.S CONSTRUCTIONS
M/s M.S. Electric Co.
SOOD ASSOCIATES PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid