| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹44.3 L+₹9.9 L (28.6%)Rejected-Finance 117 BHAISAHIYA TOLA GANESHGANJ MIRZAPUR UTTAR PRADESH 231001 | MIRZAPUR | MIRZAPUR | UTTAR PRADESH | 231001 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹59.5 L+₹25.0 L (72.7%)Rejected-Finance VIVEKANANDA PALLY UPPER BAGDOGRA PO PS BAGDOGRA DARJEELING WEST BENGAL 734 014 | DARJEELING | WEST BENGAL | 734014 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹60.3 L+₹25.9 L (75.1%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹75.5 L+₹41.1 L (119.2%)Rejected-Finance 1 A BASEMENT 30 31 RAJA HOUSE NEHRU PALACE NEW DELHI 110 019 | SOUTH EAST | DELHI | 110019 | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹48.0 L
EMD Value
₹95,940
Closing Date
23 May 2024, 6:00 pmClosed
HQ CWE Prayagraj
HQ CWE New Cantt Prayagraj
PROVISION OF OH LT LINE TO UG CABLE ALONG PROMINENT RDS AND SPECIAL REPAIR/REPLACEMENT OF LT CABLE AND PANELS NEAR SUB AREA OFFRS MESS AT NEW CANTT UNDER GE (WEST) PRAYAGRAJ.
2024_MES_651138_1
81853/W/E8
Open Tender
Civil Works
Item Rate
180 days
Prayagraj
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (West) Prayagraj
₹95,940
Yes
31 Aug 2024
25 Apr 2024
30 May 2024
26 Apr 2024
23 May 2024
9 May 2024
Amount
Supply, laying (in replacement) & testing of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified and directed.
Supply, laying (in replacement) & testing of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and directed.
Supply, laying (in replacement) & testing of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified and directed.
Supply, laying (in replacement) & testing of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed.
Supply, laying (in replacement) & testing of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and directed.
Supply, laying (in replacement) & testing of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core complete all as specified and directed.
Supply, laying & testing of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified and directed.
Supply, laying & testing of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and directed.
Supply, laying & testing of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified and directed.
Supply, laying & testing of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed.
Supply, laying & testing of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and directed.
Supply, laying & testing of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core complete all as specified and directed.
Supply, laying & testing of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed.
Excavation in trenches in soft/ loose soil n.exc 1.5 m wide and n.exc. 1.5 mtr deep for laying UG Cable and getting out Cable complete all as specified and directed.
Returning filling in with the soil obtained from item above here-in-before includiing spreading , leveling and well ramming in layers n.exc 25 cm thick complete all as specified and directed.
Removal of surplus excavated soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc.1.5 mtr above starting point complete all as specified and directed
Supply and laying sub class 'B' brick old size laid flat in trenches across the length for protection of cable as cable cover complete all as specified and directed .
M&L for sand cushioning in trenches for protection of under ground cable provided in layers of sand as 8 cm before laying the cable and 15 cm deep after laying cable complete all as specified and directed.
M&L for boring under road horizontely of size 50/80 mm bore of GI pipe for passing of cable in road in hard/soft/ loose soil complete all as specified and directed.
M&L (in replacement) for GI tubing 'light grade' with all necessary fittings laid in trenches/under road crossing/fixed on pole/wall/under floor including suitable mild steel FI clamps of required size complete for following sizes :-
50 mm bore.
80 mm bore.
Supply, fixing connecting to electrical system & testing of Busbar panel board ,cubical type for out door use, made out of 3.15 mm thick CRCA sheet factory made, totally enclosed of size not less that 900x600x500mm and supported with 4 Nos MS Angle legs , duly painted with two coats of powder coated paint over one coat of red oxide primer effectively PVC gasket and sealed mounted on PCC blocks double door type with locking arragnedment with handle at front and back with openable at front & back both side with required hinges heavy duty, compartemtalised suitably including provision for tapping incoming & outgoing electric connections with suitable size of aluminium lugs glands and comprising of the following accessories :- (i) High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of 300 Amps rating (RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve-1 Set. (ii) Grouting of panel including earth work as required PCC (1:3:6) type D-2 using 20 mm gradeded stone & plastering with (1:4 ) cement sand etc complete. (iii) MCCB 4, pole 35 KA with adjustable thermal setting, 415V, 100 Amp - 01 No. Make of MCCB : L&T, Havells, Schneider.
Supply, installation, testing and commissioning in replacement of outdoor type cubical panel board, doule door suitable for 3 phase, 4 wire, 415V, 50 Hz and CPRI approved manufacturer factory fabricated with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade provided with suitable gaskit to make it dust and varmin proof and general constructions conforming to IS : 8623/93. The LT panel shall be front and back openable and duly compartmentalized for each control gears.The panel should have suitable size of aluminium Bus -bar three phase 4 wire system having current carrying capacity 600 Amps of the incomer MCCB. The panel should have the following incoming and out going controlls duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engineer -in-charge. (PCC platform of suitable size for mounting the LT Panel is deemed to be included in the quoted rate of main Panel).
(i) Microprocessor based MCCB 4, pole 35 KA with adjustable thermal setting, 415V, 400 Amp - 02 Nos. (Incomming) (ii) MCCB 4, pole 35 KA with adjustable thermal setting, 415V, 320 Amp - 02 Nos (Outgoing). (iii) NCCB 4, Pole 26 KA with adjustable thermal setting 415V, 100 Amp -02 Nos. (iv) Change over switch 400A -01 No. (v) Digital Volt meter 0-500 volts - 01 No. (vi) Ammeter 0-500 amps with suitable size of Cts - 01 No. (vii) All connections to be done through suitable size PVC insulated copper cables (viii) LED RYB indicator - 01 Set Make of MCCB : L&T, Havells, Sneider,
Supply, installation, testing and commissioning in replacement of outdoor type cubical panel board, doule door suitable for 3 phase, 4 wire, 415V, 50 Hz and CPRI approved manufacturer factory fabricated with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade provided with suitable gaskit to make it dust and varmin proof and general constructions conforming to IS : 8623/93. The LT panel shall be front and back openable and duly compartmentalized for each control gears.The panel should have suitable size of aluminium Bus -bar three phase 4 wire system having current carrying capacity 400 Amps of the incomer MCCB. The panel should have the following incoming and out going controlls duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engineer -in-charge. (PCC platform of suitable size for mounting the LT Panel is deemed to be included in the quoted rate of Bldg Panel).
(i) Microprocessor based MCCB 4, pole 35 KA with adjustable thermal setting, 415V, 320 Amp - 01 No. (incomming) (ii) MCCB 4, pole 25 KA with adjustable thermal setting, 415V, 250 Amp - 02 Nos. (ii) MCCB 4, pole 35 KA with adjustable thermal setting, 415V, 200 Amp - 02 Nos. (iii) MCCB 4, pole 25 KA with adjustable thermal setting, 415V, 100 Amp - 02 Nos. (iv) Digital Volt meter 0-500 volts - 01 No. (v) Ammeter 0-400 amps with suitable size of Cts - 01 No. (vi) All connections to be done through suitable size PVC insulated copper cables (vii) LED RYB indicator - 01 Set Make of MCCB : L&T, Havells, Sneider,
Supply, installation, testing and commissioning in replacement of outdoor type cubical panel board, doule door suitable for 3 phase, 4 wire, 415V, 50 Hz and CPRI approved manufacturer factory fabricated with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade provided with suitable gaskit to make it dust and varmin proof and general constructions conforming to IS : 8623/93. The LT panel shall be front and back openable and duly compartmentalized for each control gears.The panel should have suitable size of aluminium Bus -bar three phase 4 wire system having current carrying capacity 400 Amps of the incomer MCCB. The panel should have the following incoming and out going controlls duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engineer -in-charge. (PCC platform of suitable size for mounting the LT Panel is deemed to be included in the quoted rate of Bldg Panel)
(i) Microprocessor based MCCB 4, pole 35 KA with adjustable thermal setting, 415V, 250 Amp - 01 No. (incomming) (ii) MCCB 4, pole 25 KA with adjustable thermal setting, 415V, 63 Amp - 05 Nos. (iii) Digital Volt meter 0-500 volts - 01 No. (iv) Ammeter 0-500 amps with suitable size of Cts - 01 No. (v) All connections to be done through suitable size PVC insulated copper cables (vi) LED RYB indicator - 01 Set Make of MCCB : L&T, Havells, Sneider,
Supply, installation, testing and commissioning in replacement of outdoor type cubical panel board, doule door suitable for 3 phase, 4 wire, 415V, 50 Hz and CPRI approved manufacturer factory fabricated with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade provided with suitable gaskit to make it dust and varmin proof and general constructions conforming to IS : 8623/93. The LT panel shall be front and back openable and duly compartmentalized for each control gears.The panel should have suitable size of aluminium Bus -bar three phase 4 wire system having current carrying capacity 600 Amps of the incomer MCCB. The panel should have the following incoming and out going controlls duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engineer -in-charge. (PCC platform of suitable size for mounting the LT Panel is deemed to be included in the quoted rate of main Panel)
(i) Microprocessor based MCCB 4, pole 35 KA with adjustable thermal setting, 415V, 630 Amp - 01 No. (ii) MCCB 4, pole 35 KA with adjustable thermal setting, 415V, 250 Amp - 04 Nos. (iii) Digital Volt meter 0-500 volts - 01 No. (iv) Ammeter 0-500 amps with suitable size of Cts - 01 No. (v) All connections to be done through suitable size PVC insulated copper cables (vi) LED RYB indicator - 01 Set Make of MCCB : L&T, Havells, Sneider,
Supply, installation, testing and commissioning in replacement of outdoor type cubical panel board, doule door suitable for 3 phase, 4 wire, 415V, 50 Hz and CPRI approved manufacturer factory fabricated with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade provided with suitable gaskit to make it dust and varmin proof and general constructions conforming to IS : 8623/93. The LT panel shall be front and back openable and duly compartmentalized for each control gears.The panel should have suitable size of aluminium Bus -bar three phase 4 wire system having current carrying capacity 400 Amps of the incomer MCCB. The panel should have the following incoming and out going controlls duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engineer -in-charge. (PCC platform of suitable size for mounting the LT Panel is deemed to be included in the quoted rate of Bldg Panel)
(i) Microprocessor based MCCB 4, pole 35 KA with adjustable thermal setting, 415V, 250 Amp - 01 No. (incomming) (ii) MCCB 4, pole 25 KA with adjustable thermal setting, 415V, 100 Amp - 04 Nos. (iii) MCCB 4, pole 25 KA with adjustable thermal setting, 415V, 63 Amp - 01 No. (iv) Digital Volt meter 0-500 volts - 01 No. (v) Ammeter 0-500 amps with suitable size of Cts - 01 No. (vi) All connections to be done through suitable size PVC insulated copper cables (vii) LED RYB indicator - 01 Set Make of MCCB : L&T, Havells, Sneider,
M&L for earthing of galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI strip 32x6mm as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of GI strip protected by 40 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation and earth work & connecting the earthing to an earthing test point complete all as specified & directed by Engineer-in-Charge.
S&F VTPN 8 way DPX³ with double door type As per IEC 61439-3, Suitable for Surface Mounting, With 250/200 A with Busbar for each phase, With 2 Neutral bar, 2 Earth bar and Cable ties for Cable management, Fully insulated busbar & shrouded Neutral bars, Improved Pan assembly for ease of installation, Prefitted masking sheet, incl provn of MCCB of capacity 250/200 AMP as incomer fixed in the DB Reversible Door for IP 43 & IP 54 DB's, MCB's as outgoing [IP 4 -IK 09 with metal door complete all as specified and directed. Make:L&T /Legrand /ABB/Havells ,
S&F for MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA for main DB complete all as specified and directed.
S&F for MCCB 4 Pole, 415 V, Adjustable type,200 Amps with breaking capacity 36 KA for main DB complete all as specified and directed.
Dismantling of ACSR or AAC and any type conductors from over head line complete all as specified and directed by Engineer-in-Charge.
Dismantling insulators any type, any size or any position complete all as specified and directed by Engineer-in-Charge.
Dismantling stay assembly complete all as specified and directed by Engineer-in-Charge.
prabhawati shanti automobiles
GANAPATI TRADING
Titco Electricals
MONA GENERATOR SEVICES PVT. LTD.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .