| 1 | L1₹22.0 LAccepted-AOC 02 PADRI SHIV NAGAR SHIV NAGAR MAHARAJGANJ UTTAR PRADESH 273303 | MAHARAJGANJ | UTTAR PRADESH | 273303 | L1 | Accepted-AOC Accepted being lowest bidder | |
| 2 | L2₹24.3 L+₹1.4 L (6.22%)Rejected-Finance | L2 | Rejected-Finance Rejected being not lowest bidder | |
| 3 | L3₹24.7 L+₹1.9 L (8.14%)Rejected-Finance | L3 | Rejected-Finance Rejected being not lowest bidder | |
| 4 | L4₹25.6 L+₹2.7 L (11.8%)Rejected-Finance HOUSE NO 206 GAIKWAD ALI NEAR DATTA CHOWK MUNDHWA PUNE 411036 | PUNE | MAHARASHTRA | 411036 | L4 | Rejected-Finance Rejected being not lowest bidder | |
| 5 | L5₹27.7 L+₹4.8 L (21.0%)Rejected-Finance NO 98 1 1C YOJANANAGAR LOHEGAON WAGOLI ROAD NEAR SIVBHA DARBAR HOTEL LOHEGAON PUNE 411047 | PUNE | PUNE | MAHARASHTRA | 411047 | L5 | Rejected-Finance Rejected being not lowest bidder |
Tender Value
₹30.3 L
EMD Value
₹60,600
Closing Date
11 Feb 2021, 6:00 pmClosed
CWE KIRKEE
Headquarters CWE Kirkee, Military Engineer Services, Range Hills Road, Kirkee, Pune-411003
SPECIAL REPAIR TO BLDG NO P 130 AT SOUTHERN COMMAND GIRLS HOSTEL IN THE AOR UNDER AGE B/R I IN GE (C) KIRKEE.
2021_MES_413045_1
CWE/KKE/TOKEN-64 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
KIRKEE
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹60,600
Yes
23 Feb 2021
15 Jan 2021
13 Feb 2021
15 Jan 2021
11 Feb 2021
30 Jan 2021
16 Jan 2021 - 22 Jan 2021
Amount
Dismantling single layer Mangalore pattern or similar tiles in roofing. complete all as specified and as directed
Dismantling Mangalore pattern, inter locking at side joints laid/ beded in lime or cement mortar complete all as specified and as directed.
Dismantling battens for tiles singles etc of any size including tiling fillets spaced exc 15 cm complete all as specified and as directed.
Dismantling timber scantling 40 Sq. cm and over in section, in any position framed work complete all as specified and as directed.
Dismantling timber scantling in fillets, rails, posts, rafters, purlins etc. under 40 Sqcm in section framed work complete all as specified and as directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet mangalore tiles pattern/colour 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws with one corrugation side lap, bent to shape complete all as specified and as directed.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F rolled MS section as in roof trusses (framed), trussed, verticle members of sheds, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc fixed with angle cleats or other connecting plates confirming to Fe 410-W quality B complete all as specified and as directed.
S & F rolled MS section as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates confirming to Fe 410-W quality B complete all as specified and as directed.
S & F MS screw bolts machine made with hexagonal or square heads at one end and screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, dia of shank 5 to 10mm and length exc 5cm and n exc 10cm complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs any thickness, including cover fillets complete all as specified and directed.
M & L of E-board 'Everest' make 600x600x4mm thick white prelaminated sett embosed reinforced designer ceiling board tiles of approved texture at all height laid on Hot dipped Galvanised iron imposed grid with 24mm wide T-section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33mm thick GS sheet and of size 24x32x3000mm and spaced at 1200mm centers securely fixed to the structural soffits by approved hangers at 1200mm maximum centers. Hangers of GI wire 4mm dia to be fixed by approved rawl plug, level and justers and screws etc. The last hanger at the end of each main runner shall not be greater than 450mm from adjacent wall. Flush fitting of 1200mm long cross tee (with double stitching) to be interlocked between main runners at 600mm center to form 1200x600mm modules cross tee longer than 600mm to be supported independently. 600x600mm modules to be formed by fitting 600mm long cross Tee centrally between the 1200mm cross tee. Tee, Perimeter wall angle shall be of 0.45mm thick GS sheet of size 19x19mm and 300mm long of white colour all as per manufacture instruction, including taking down wall/ceiling boards(fibre, pulp insulation etc) or inslutation boards any thickness incl fillets complete all as directed.
Demolition of brick work or stone masonry built in cement mortar including all quoins, arches, pillars etc and removing debries outside MD land complete all as specified and as directed.
M&L for block masonry with solid blocks of precast cement concrete class designation C-5 (using 20mm graded stone aggregate), exc 10cm in width and setting in cement mortar (1:6) complete all as specified and as directed
Material and labour for 15mm thick cemet plalster in CM 1:4 over concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Material and labour for 15mm thick cement plalster in CM 1:6 over concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M & L for providing cement concrete type B-1 (1:2:4) using 20 mm graded crushed stone aggregate as in coping/benching/bed block and the like including necessary form work complete all as specified and as directed.
M&L for two coats of exterior acrylic paint of any shade in camouflage pattern as approved by GE over a coat of self primer on newly plastered surfaces of walls including preparation of new surfaces as per manufacturer's instrucitons complete all as specified and as directed.
M & L preparing new plastered wall surfaces by applying 3mm thick wall care putty to get smooth and even surfaces as directed and applying two coats of oil bound distemper complete all as specified and as directed.
M & L for preparing new steel surfaces of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
M&L for one coats of exterior acrylic paint of any shade in camouflage pattern as approved by GE over a coat of self primer on old plastered surfaces of walls including preparation of old surfaces as per manufacturer's instruciton complete all as specified and as directed.
M & L for preparing of old plastered wall surfaces by applying 3mm thick wall care putty to get smooth and even surfaces as directed and applying two costs of oil bound distemper complete all as specified and directed.
Taking down copper/aluminium point wiring ( light, fan, socket, power ) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately ) and making good disturbed surface of walls, floors, etc complete all as specified and as directed.
M & L for point wiring complete with single core multi stranded Copper conductor FRLSH of size 1.5 sqmm PVC insulated unsheathed 1100 volt grade in and including concealed PVC casing caping/PVC conduit suitable dia with junction/ bends etc wall/roof /trusces etc including 1.5 sqmm. green PVC insulated FRLSH cable for earth continuty for the following :-
(a) One light point controlled by one, one way switch
(b) One ceiling fan/ exhaust fan point controlled by one, one way switch and regulator
(c) One 3 Pin 5 Amps Socket outlet point controlled by one way switch on independent board.
(d) One 3 Pin 5 Amps switch socket outlet point controlled by one switch on same board
All as per item No 24 above but with 2.5 sqmm cable insulated for 3 pin 15 Amp multipin socket outlet including 2.5 sqmm PVC insulated copper wire for earth continuity on independent board
S&F stepped type modular fan regulator for ceiling fans including necessary connections of capacity 120 watts 2 module,240 Volt. complete all as specified and as directed.
S&F modular switch 1 way 6 amp,1 module.complete all as specified and as directed.
S&F modular switch 1 way 16 amp,1 module complete all as specified and as directed.
S&F modular socket 6 A-2/3 pin combined 2 module complete all as specified and as directed.
S&F modular socket 6 A/16 A-2/3 pin combined 2 module complete all as specified and as directed.
S&F white cover plate modular with frame of 2 module complete all as specified and as directed.
S&F white cover plate modular with frame of 4 module complete all as specified and as directed.
S&F white cover plate modular with frame of 6 module complete all as specified and as directed.
S&F white cover plate modular with frame of 8 module complete all as specified and as directed.
S&Fmodular metal flush box 2 module complete all as specified and as directed.
S&Fmodular metal flush box 4 module complete all as specified and as directed.
S&Fmodular metal flush box 6 module complete all as specified and as directed.
S&Fmodular metal flush box 8 module complete all as specified and as directed.
S&F ceiling rose surface PVC 65 x 50 mm two/three terminals complete all as specified and as directed.
M & L for sub main wiring with two single core PVC insulated unsheathed, 1100 Volts grade, copper cable 6 sqmm stranded conductor and drawing through and including rigid PVC casing caping of suitable size with accessories such as junction boxes, bends, tees etc. including continous earth wire PVC insulated unsheathed 1100 volts grade, cable 6 sqmm copper conductor and connected to common earth dolly after taking out existing submain of any type, size, capacity complete as directed. Note :-(i) Two runs of cable and one run of earth wire & casing caping shall be measured and paid as one unit.
M & L for sub main wiring with two single core PVC insulated unsheathed, 1100 Volts grade, copper cable 4 sqmm stranded conductor and drawing through and including rigid PVC casing caping of suitable size with accessories such as junction boxes, bends, tees etc. including continous earth wire PVC insulated unsheathed 1100 volts grade, cable 4 sq mm copper conductor and connected to common earth dolly after taking out existing submain of any type, size, capacity complete as directed. Note :-(i) Two runs of cable and one run of earth wire & casing caping shall be measured and paid as one unit.
S&F MCCB distribution board,Flush on wall,TPN DB-VTPN, MCCB incomer, IP 30 protection, Double door, metal enclosure, TPN, 440 Volts, 6way VTPN all as specified and directed. Make cat part no.5077-41 of Legrand or equivalent of schneider/ ABB as approved by GE.
S&F MCB distribution board, Flush on wall as MCB incomer, IP 43 protection, Double door, metal enclosure, SPN, 230 Volts, 12 way ETPN all as specified and directed. Make cat part no.5076-12 of Legrand or equivalent of schneider or ABB as approved by GE.
S&F MCCB 4 pole415 volt ,adjustable type 200 amps with braking capacity 25 KA complete all as specified and as directed.
S&F MCB, Single Pole and neutral 40 to 63 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve. complete all as specified and as directed. Make-cat part no.4086-18 to4086-20 of Legrand or equivalent of schneider/ABB as approved by GE.
S&F MCB, Single Pole and neutral 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve. complete all as specified and as directed Make-cat part no.4086-9 to4086-17 of Legrand or equivalent of schneider/ABB as approved by GE.
S&F MCB, Single Pole 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve. complete all as specified and as directed Make-cat part no.4085-87 to4085-95 of Legrand or equivalent of schneider/ABB as approved by GE.
S&F LED type tube light fittings with LED tube, 18 W, CDL, 230 volts, 4 feet long,Warm Yellow, complete with all accessories internally pre wired and connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable with 02 Nos mounting casing box all as per Cat No BCLSB 18 NW for channel and Cat No BLRB 18W CW for tube of Bajaj or equivalent model of Philips /Wipro/Crompton Greaves as approved by GE
S&F Square shaped recess mounted LED slim Flat panel suitable for fixing in aluminium framed ceilling, 36 watt, 2'x2'size, warm yellow complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable incl dismentling taking down unsv fitting any type all as specified and directed. Make-CG, Cat Part No LCTRP-36-CDL (2x2) (STELLUX-P) or equivalent in Bajaj/Philips/HPL as approved by GE
S&F LED security light 25 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade 25/32 mm dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener incl dismentling taking down unsv fitting any type all as specified and directed. Make-CG, Cat Part No LSTS-25-CDL or equivalent in Bajaj/Philips/HPL/Havells as approved by GE
Supply and fix ceiling fan (with and including assembling the same) with existing fan hook/box, 1200 mm (48") sweep and connecitng up complete with and including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to porcelain connector block of fan suitable on working AC, SP 230 V electric supply including dismantling old unserviceable one and deposited to MES Store Yard. complete all as specified and as directed.
S&F exhaust fan, single phase, heavy duty,metal frame 300 mm sweep, 1400 RPM including fixing of mounting frame in the round hole including making suitable chase cutting on wall finishing and matching with sorroundings by means of rugged bolts, nuts and washers etc including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to the porcelain connector block of exhaust fan complete all as specified and as directed.
S&F switch socket outlet 20 amp with indicator including modular metal box flush mounted complete all as specified and as directed.
S&F Air circulator fan 450 mm or 18" including dismantling and taking out unsv one . complete all as specified and as directed. Make Bajaj/crompton/usha as approved by GE.
S&F LED focus light 10 watts complete all as specified and as directed. Make bajaj/ crompton/ HPL as approved by GE.
M&L MS fan hook made into shape as per site requirement with nut,bolt and washers as required at site complete all as specified and as directed.
Supply and lay XLPE insulated heavy duty electric cable with stranded aluminium conductor 1100 volts grade laid in trenches/floor,fixed on pole or wall completed all as directed of size 3.5 core 35 sq mm.complete all as specified and as directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying of cable and getting out in soft integrated rock. complete all as specified and as directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick.complete all as specified and as directed.
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.complete all as specified and as directed.
M&L for fine stone dust for cousioning of UG cable/ at cable trenches inside substation bulding complete all as specified and as directed. ( Note: Thickness after punning down shall be measured and paid)
S & F sub-class ‘B’ brick, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable Protection, complete all as specified and as directed.
M&L GI tube light grade laid in trenches or fixed on pole /wall including nessry fittings of bore 40 mm complete all as specified and as directed.
M & L for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 6 mtr long buried directly and vertically in ground with top edge at ground level after making bore hole of size not less than 300 mm dia and 6.0 Mtr long using suitable mechanical drilling rig (for drilling near the specified bldg), connected with galvanised steel earthing lead of 4mm dia all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with RCC precast pit cover slab 400mmx400mmx80mm with handle for lifting made out of 8mm dia MS rod, funnel, wiremesh, 15 mm dia light grade GI tubing for protection of GI wire 4mm dia, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion.
GGS Infra
CHAITRALI KAILAS TAWARE
AJINKYA VIKRAM GAIKWAD
S.R.M.K Enterprises
M/S SANDEEP H BHINGARDIVE
C J Enterprises
Shri Sant Cosntruction
DAKSH ENGINEERS AND BUILDERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .