Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹61.5 LAccepted-AOC FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹67.2 L+₹5.7 L (9.19%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹71.0 L+₹9.5 L (15.4%)Rejected-AOC 302 SIDDHIVINAYAK APPT A WING MUMBAI K K MARG JACOB CIRCLE MUMBAI CITY MAHARASHTRA 400 011 | MUMBAI | MAHARASHTRA | 400011 | L3 | Rejected-AOC REJECTED | |
| 4 | Rejected-Technical | - | Rejected-Technical No remark in WLR | |
| 5 | Rejected-Technical 214 2ND FLOOR SAMRUDDHI COMMERCIAL PREMISES CHINCHOLI BUNDER ROAD MINDSPACE MALAD WEST | - | Rejected-Technical Eligibility criteria not fulfill |
Tender Value
₹64.5 L
EMD Value
₹1.3 L
Closing Date
6 Oct 2021, 6:00 pmClosed
GE(NW) BAHDNUP
GE(NW) BAHDNUP, MUMBAI
SPECIAL REPAIRS TO BLDG NO NS 164 AND 165 AT MO(MB) GHATKOPAR UNDER GE(NW) BHANDUP
2021_MES_455808_3
8133/B
Open Tender
Civil Works
Item Rate
270 days
GHATKOPAR
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹1,000
GE(NW) BHANDUP
₹1.3 L
Yes
4 Apr 2022
11 Sept 2021
7 Oct 2021
11 Sept 2021
6 Oct 2021
18 Sept 2021
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises etc out side MD land complete all as specified and directed.
Demolition of brick work or stone boulder masonry,built in cement mortar or cement lime mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work and precast concrete articles and removal of rubbish/ demolished materials out of MD land complete all as specified and directed.
Taking down cement or cement lime plaster of any description on brick or stone wall and ceiling surface including raking out joints, hacking for key, scrubbing down with water etc and disposing off the rubbish outside MD land complete all as specified and directed.
Taking down chowkat or frame with shutter (without taking off shutter from the frames) and including grills/ guard bars not exceeding 1.5 Sqm each complete as directed
M/L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.18 sqm and n exc 0.36 sqm in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15mm thick screed bed in CM 1:6 laying floor finished complete all as specified and directed.
M&L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.06 sqm n exc 0.11 sqm in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:4 laying floor finished complete all as specified and directed.
M&L for glazed ceramic coloured tiles 300x200mmx7mm thick in vertical surfaces such as skirting/dado and risers to steps and including over 10mm thick rendering in CM 1:3 on fair faces of brick/concrete surfaces as in backing coat for tiles. etc, all as specified and directed.
M&L for 20 to 25mm machine cut mirror polished kota stone slab as in flooring laid over cement mortar screed bed jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and including over 20 mm thick screed bed in CM1:4 complete all as specified and as directed.
M&L for 20 to 25mm machine cut pre polished kota stone slab as in skirting of floor laid over cement mortar backing coat jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and including over 10 mm thick Rendering in CM1:4 complete all as specified and as directed.
M&L for pre cast cement concrete louvers jallies 25 mm type B-0 1:2:4 using 12.50 mm graded aggregate, thick including all mouldings but excluding frame all as spd and directed.
M&L for brick work with sub class B bricks straight or curved on plan exceeding 6 m mean radius built in CM 1:6 complete all as specifed and directed
M & L for rendering 10 mm thick in CM 1:6 on brick walls or concrete surfaces and finishing the surfaces even and smooth complete all as specified and directed.
M & L for rendering 5 mm thick in CM 1:3 on concrete surfaces as in ceiling and finishing the surfaces even and smooth complete all as specified and directed.
M&L for 20mm thick (12mm + 8mm) in two coats polymer modified ready mix cement based plaster on the wall surface including finishing the surfaces of top layer in the proportion as per manufacturer recommendation, for the under mentioned storeys of the existing buildings, complete all as specified and directed, Make : Easy plast form M/s wall plast or chemplast or readiplast from ultratech, Note : The thickness of plaster specified above is the minimum thickness and the quoted rates shall also be demand to included for provision of dubbing of the surfaces with the ready mix plaster and no extra payment shall be admissible on the account”.
Supply only integral water proofing compound.
Material and labour for cracks with polymer based chemical Dr fixit cracks shrink free or equivalant for cracks not exc 10mm in width as per manufacturer instruction on wall surfaces on concrete or masonry incl scaffolding etc complete all as spd.
M&L preparation of new plasterd surfaces of wall and applying two coats of Dr fixit rain coat over one coat of Dr fixit primer all as spd and directed by Engr-in-Charge
M&L for Complete removal of existing treatment with mechanical grinding machine(vacume type) on walls including washing down, rubbing down and applying two coats of rain coat over one coat of primer and all as spd and directed by Engr-in-Charge
M & L for preparation of new plastered surfaces of walls and applying Two coat of oil bound distemper including application of wall care putty for smooth finish.etc with roller over one coat of alkali resistant primer including chalk whiting complete all as specified and directed.
M&L for Complete removal of existing painted surface with mechanical grinding machine (vacume type). scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and thereafter applying with roller Two coat of oil bound distemper over one coat of primer suitable for OBD including application of wall care putty for smooth finish.etc complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed
M&L for preparation of old decorated surfaces of ceiling brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and thereafter applying Two coat of white wash complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified and directed
M&L for preparation of old decorated surfaces of wall brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and thereafter applying Two coat of white wash complete all as specified and directed.
S&F Solid PVC door frame (Chowkhat) of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube etc complete all as specified and directed.
S&F for Factory made solid PVC Moulded door shutter, 28 to 30 mm thick, with 2,4 or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing with wood free EPS complete all as specified and as directed.
S&F aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40mm and fixed tinned tacks or aluminium wire staples,and fixing of teak wooden beeding complete all as specified and as directed by the Engineer in charge.
S&F bands, steps, supports or stays for rain water, hooks (stay) heavy for large gates, hook and pintle hinges clamps, hold fasts wall ties, hooks for hanging james and similar small articles Fe-410-0 or Fe-310-0 complete all as specifed and directed.
M&L for PCC 1:2:4 Type B1 using 20 mm graded aggregate as in hold fast, coping ,cills ,steps, seismic and other similar bands, plinth course, string course, parapets, railing, bed plates, kerbs and the like including weathering,slightly rounded or chamfered angles and throating as directed.
S&F for 20mm dia curtain rods powder coated aluminium decorated with fixing brackets, stops, rollers etc complete all as specified and directed
S&F 100 mm stainless steel butt hinges,complete all as specified and directed
S&F 150mm length aluminium anodised barrel tower bolt of extruded section complete all as specified and directed
S&F 150 mm length extruded aluminium alloy handles,fabricated type, anodised complete all as specified and directed
S&F alluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast alluminium alloy and fixed of length of bolt 300 mm complete all as specified and directed.
Dismantling cast iron of any description etc complete all as specified and directed
S&F 75mm bore PVC (SWR) pipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps8mm dia with two nuts wall nails etc complete all as specifed and directed.
S&F 110mm bore PVC (SWR) pipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps8mm dia with two nuts wall nails etc complete all as specifed and directed.
S&F 75mm bore PVC (SWR) bends any radius dimnishing pieces or tapers with access doors etc, complete all as specified and as directed.
S&F 110mm bore PVC (SWR) bends any radius dimnishing pieces or tapers with access doors etc, complete all as specified and as directed.
S&F in repair PVC floor trap 75mm dia outlet, with CP grating including jointing to waste pipe, fixed in cement concrete type B1 (1:2:4) & including removing old trap complete all as specified and as directed.
S&F in repair PVC floor trap 100mm dia outlet, with CP grating including jointing to waste pipe, fixed in cement concrete type B1 (1:2:4) & including removing old trap complete all as specified and as directed.
S&F in repairs vitreous china squatting pan, white, orissa pattern pan of size 580 mm x 440 mm of standard quality with integral foot rests,and including 'P' trap or 'S' Trap complete including connection to trap and to flushing pipe, anti syphonic pipe etc., complete all as specifiedand directed.
S F in repair wash down closet pedestal pattern white and including plastic water closet seat cover as per required colour with flat bottom and cover and mild steel chromium plated or aluminium hanging device etc all as spd.
S Fin repair brass Health faucet with 1.2 mtr tube and hook complete all as spd and directed.
S&F in repairs colour wash hand basin, vitreous china white of size 550x 400mm excluding taps, waste chain and plug and porcelain stopper but including brackets,32mm waste fitting and waste pipe of 32 mm bore, brass, chromium plated for glazed ware wash basin and 15mm dia pillar taps chromium plated fancy type etc complete all as specified and directed.
Supply and fix in repair 10 ltr, PVC, valveless, syphonic action type, flushing cistern, low level/ high level including inlet, ball valve, float and handle including brackets with and including PVC flush pipe 32 mm bore, connecting to WC etc, complete all as specified and directed.
S&F in repairs CP angle cock 15mm bore fancy type chromium plated.with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs CP long nose bib tap 15mm bore fancy type with crutch or butterfly handle, screwed for iron pipe or for unions and fixed complete all as specified and directed.
S&Fin repair 15mm size PVC connection with PTMT nuts 450mm length.complete all as specified and directed.
S&F inrepair stainles steel sink with drainage board , 1 mm thick sheet of steel grade AISI 304 for kitchen or laboratory, with plug, waste pipe, washers including CI cantilever bracket, connecting union etc., overall size 915 x 460 mm with bowl size 410 mm x 330 mm x 160 mm including supply and fixing bib tap CP with long body screwed for iron pipe complete all as specified and directed. Make : Nirali, Bule star ISI marked.
S&F in repair CP Tubular towel rail with hook 20 mm dia 600mm long between flanges of fixed with and including chromium plated brass screws and wooden/plastic screws. complete all as specified and directed.
S&F Soap dish, Stainless steel fancy type approx size 160x160x90mm complete all as specified and directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 15mm complete all as specified and directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 20mm complete all as specified and directed.
S&F 15mm bore U-PVC pipes of pressure rating 10kg/cm 2 fixed complete to walls, ceiling or in floor etc. with all fittings complete all as specified and directed.
S&F 20mm bore U-PVC pipes of pressure rating 10kg/cm 2 fixed complete to walls, ceiling or in floor etc. with all fittings complete all as specified and directed.
Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms)
S&F in repair Vitreous China urinals,half stall type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to pugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for ischarge pipe. (Exclusive offixing supply pipe to flushingcistern, trap and waste pipe)
Dismantling stone slabs and tiles of any description or thickness in kitchen platform and similar work laid, bedded and pointed in cement mortar and removal of rubbish/ demolished materials out of MD land complete all as specified and directed
M&L for 18-20mm thick granite(of any type) work table rubbed and polished as in steps, jambs, pillars, windows-cill, cooking platform , jambs and the like in cement mortar (1:4) including pointing in white / coloured cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting , moulding etc over and including 10mm thick rendering / screed in CM 1:4 on fair faces of brick/concrete surfaces complete all as specified and directed.
M&L PCC 1:4:8 C-2 (using 40mm graded crushed stone aggregate) as in sub base ( 75mm thick ) finished even and fair all as specified.
M&L for chequered cement concrete tiles 25cmX25cmX22mm thick,set jointed in neat cement slurry in floors with grey cement and pigments and including over 20mm thick screed bed in CM 1:4 etc and as approved by EIC
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided and disposing off the rubbish outside MD land complete all as specified and directed.
S&F for Pre- Painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping ,drilling of screws/suitable length GI 'J' or 'L' hooks in roof complete all as specified and directed.
S&F for Pre- Painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/rigdes, fixed with self tapping ,drilling of screws/suitable length GI 'J' or 'L' hooks in roof, including necessary scaffolding etc complete all as specified and directed.
S&F for roof trusses (framed) trussed, Purlins, crane gantries, rails and fastenings and heavy brackets framing(Beam, Angle, Channel or flat section,plain plates) including distance pieces, cleats ,welding and braceing etc,Fe-410W(Gde-E-250)quality -B, including necessary scaffolding etc complete all as specified and directed.
M&L for preparation of new steel surfaces and applying two coat of synthetic enamel paint over a coat of red oxide etc complete all as specified and directed.
Dismantling of roof terracing cement / brick concrete (un-reinforced) and existing water proofing treatment of any thickness in any position and of any portion from top of roof of building, cleaning surface of roof with wire brush / mechanical brush and with water thoroughly to remove all dust / dirt and loose particles to expose base concrete roof slab and removal of rubbish / demolished material out of MD land complete all as specified.
M&L for PCC 1:2:4 Type B0 using 12.5 mm graded aggregate with 2% by weight of cement or as per manufacturer's instructions water proofing as in levelling course, haunching, coping and similar works over RCC roof surface and RCC over head tank top surface including rounded or chamferred on edges and formwork etc all as specified and directed.
Supply and Application of 5 Layer SHR Waterproofing Coating System on leaking concrete surface by thorough surface preparation followed by one absorption coat of Thermacool WP 51, nano-tech modified, UV resistant elastomeric clear coat having min. 50% solids, then overcoating with 2 Coats of Thermacool WP51+Cement mixture as waterproofing coat having +450% Elongation, Tensile Strength min. 2.2 MPa and then top-coated with 2 Coats of Thermacool 0.3 C pure acrylic based , UV resistant, non-yellowing, bio-organism resistant (anti-fungal, anti-bacterial) Solar IR Heat Reflective coating conforming to BIS STD IS 17218:2019 with Pull off Adhesion 2.8 Mpa, passes 2000 hrs accelerated durability test, suitable for all types of cementitious surfaces, white colour, matt, surface coverage 3.25 sqm/Ltr/2 coat, DFT 100-120 microns using brush, roller, airless spray gun as applicable. The product should have been tested at IIT or NABL Approved Lab and application is to be done by Thermacool approved applicator only.
M&L for Epoxy bond coat as approved by GE over exposed concrete surfaces prior to application of any type of mortar / concrete to ensure bond between old concrete & new concrete/ new mortar by brush application, complete all as specified and directed.
M&L for carry out application of Bi -polar migratory corrosion inhibitor on RCC surfaces , complete all as spd and directed .( Note: Mode of measurment superficial area of concrete will be measured.)
M&L for Anticorrosive Treatment to Reinforcement by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces complete all as specified and directed . Note :- Mode of measurement: superficial area of concrete will be measured.
M&L for casting & repairing of excessively damaged distressedRCC members (exceeding 60mm in thikness) with prebatched, prepacked, single component ready to use microconcrete as approved by GE, at any level/ height and at any lead or lift as directed including prefabricated water tight formwork, centering, scaffolding, also including mixing , laying, levelling, finishing, curing etc as per manufacturer's specifications and all other relevant works, complete all as specified and directed. (Note : Reinforcement only shall be measured and paid separately).
M&L for checking of damaged RCC surface by low impact hammer, dismantling of damaged part and removing to outside MD landbuilding up the profile of structural members using polymer modified mortar of make approved by GE , while the bonding agent is still tacking upto 20mm thickness, including levelling, profiling etc, complete all as specified and directed.
M&L for checking of damaged RCC surface by low impact hammer, dismantling of damaged part and removing to outside MD land and building up the profile of structural members using polymer modified mortar of make as approved by GE, while the bonding agent is still tacking exc 20mm but nexc 40mm thickness, including levelling, profiling etc, complete all as specified and directed.
M&L for special treatment for sunken portion of WC’s/Bath & toilet executed in following stages:- Stage 1 :- Demolition of WC including lime concrete and cement concrete coba etc and preparing the surfaces of existing sunken portion of WCs or bath etc with wire brush to remove all loose dirt. Oil grease etc including removing debris outside MD land etc. Stage 2 :- Providing 10mm thick plaster in CM 1:3 mixed with integral water proofing chemical of make as approved by GE in the proportion/quantity all as per Manufactures instructions complete. Stage 3 :- Apply Dr Fixit Primeseal prime or equivalent of STP Ltd (and allow to dry for 8 Hours) all as per manufactures instructions. Stage 4 :- Apply two coats of water proofing elastomeric coating system of Dr fixit raincoat with DFT 100 Micron or shalicry 215 of STP (The surface after painting one coats shall be allowed to dry of 6 hours before next coats) all as per manufacture instructions. Stage 5 :- Rendering 10 mm thick in CM 1:3 mixed with integral water proofing chemical Dr fixit pidicrete URP or plaster seal of STP Ltd all as per manufactures instructions. Stage 6 :- All Cl joints shall fixed with mixture or cement fine sand and plaster seal of STP Ltd or Dr Fixit pidicrete URP all as per Manufactures instruction. Stage 7 :- Making holes in wall and fixing 600 mm long 40mm dia medium grade GI spout for draining the surplus water if any. Stage 8 :- Carry out ponding test for 48 hours to ensure water tightness of repaired sunken portion water tightness of repaired sunken portion water tightness of repaired sunken portion and filling of sunken portion for cement concrete type E2 1:5:10 using 40mm graded aggregate as in lean concrete complete all as specified and directed. Note :- (a) Only plan area shall be measured and accorded for payment under this item. (b) Depth of sunken portion of WCs/Baths shall be upto 35 cm, which is to be taken into account whilw quoting the rate against the item. (c) Rate quoted by contractor shall be demand to be included for the horizontal and vertical treated surfaces of sunken portions of WC & Bath.
Taking down existing aluminium window any size without taking down its hooks and staking at store yard with due care and after repair work at site refixing of the same at same location with required screws. Complete all as specified and directed.
Taking down carefully copper/aluminum point wiring of any type such as Concealed/surface/batten/casing and capping (light fan, socket or power) complete including fitting such as switches, ceiling roses, pendants, lamp/bracket holders, sketch/bulk head fittings, regulators, sockets, board outlets etc and making good the disturbed surfaces of walls, floor, ceiling etc for rewiring and repairs etc.
M&L for point wiring for light/fan controlled by one switch with 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and including PVC concealed conduit having thickness not less than 2 mm, including 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching with the existing colour and all as specified . Note: (i) colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green) 2. Modular flush boxes/inner&outer plates measured and paid separately.
All as per srl item No 81 above but for 5 pin 5 amps socket outlet on the same board with other switch all as specified.
All as per srl item No 81 above but for 5 pin 5 amps socket outlet indenpendent board of light point all as specified.
M&L for point wiring with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLSH with and in and including PVC concealed conduit having thickness not less than 2 mm, including 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLSH as earth continuity conductor connected to common earth dolly.and including cutting chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching existing colour and all as specified . Note: (i) colour coding is to be maintained .(Ph-Red, N-Black, Half-Yellow, Earth- Green) 2. Modular flush boxes/inner&outer plates measured and paid separately.
M&L for point wiring with 4 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and in and including PVC concealed conduit having thickness not less than 2 mm , including 4 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly.and including cutting chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching existing colour and all as specified . Note: colour coding is to be maintained .(Ph-Red, N-Black, Half-Yellow, Earth- Green) 2. Modular flush boxes/inner&outer plates measured and paid separately
M&L for submain wiring in and including PVC conduit having thickness 2 mm, 25 mm dia with two run of PVC insulated, sheathed multistranded copper conductor of 10 sqmm(FRLS) and one run of PVC insulated, sheathed multistranded copper conductor 10 sqmm (green in color) for earth continuity conductor and connected to common earth dolly with thimble etc, cutting chiseling for concealed piping and making good the disturbed surface area white wash/colour wash to matching with existing colour complete all as specified and directed.. (Note: Two run of 10 sqmm plus one run 10 sqmm of earth wire will be measured as 1RM) including dismantling of existing unserviceable submain wiring all as specified and directed. Note: colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)
M&L for ceiling rose three terminals AC 240 volts 50Hz complete all as specified.
Supply and fixing modular ceiling fan regulator 120 watt 2 module AC 240 volt complete all as specified and directed.
M&L for switch modular one way 6 amps 1 module complete all as specified.
M&L for switch modular one way 16/20 amps 1 module complete all as specified.
M&L for socket modular 6Amp 2/3 pin combined 2 module complete all as specified and directed.
M&L for socket modular 6/16 Amp 2/3 pin combined 2 module complete all as specified and directed.
Supply and fix in repairs sheet metal enclosure powder painted for MCB DB SPN 8 way double door with din rail and 200 Amp bus bar complete all as specified and directed.
Supply and fix in repairs MCB SP 240 Volts 6 to 32 Amps breaking capacity 10 KA rating B Curve complete all as specified and directed.
Supply and fixing modular metal flush box 3 module complete all as specified and directed.
Supply and fixing modular metal flush box 4 module complete all as specified and directed.
Supply and fixing modular metal flush box 6 module complete all as specified and directed.
Supply and fixing modular metal flush box 8 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame 3 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame 4 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame 6 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame 8 module complete all as specified and directed.
Material and Labour for tube light fitting LED 20 watt with decorative end caps made out of CRCA sheet powder coated complete with housing with aluminium heat sink on back of leds ,power factor >0.9,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting and shall be fitted on new plastic square/round block complete all as per specified and directed. Note:1.Contractor shall produce LM79 & LM80 test reports from OEM owned NABL accredited laboratory.Contractor shall also produce certificates for power factor and surge protection from the company at no extra cost.
Material and Labour for tube light fitting LED 10 watt with decorative end caps made out of CRCA sheet powder coated complete with housing and with aluminium heat sink on back of leds,power factor >0.9,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting and shall be fitted on new plastic square/round block complete all as per specified and directed. Note:1.Contractor shall produce LM79 & LM80 test reports from OEM owned NABL accredited laboratory.Contractor shall also produce certificates for power factor and surge protection from the company at no extra cost.
Supply and fix in repairs highly efficient high power 35 W LED street light fitting with pressure die cast aluminium housing reflector and enclosed with heat resistant toughened glass IP66 protection AC 240 Volts 50 HZ refractive lens with suitable electronic drive PF > 0.9 complete including taking exiting unserviceable street light fitting.
Taking down existing ceiling fans and re-fixing the same ceiling fan including provisioning of cable from celing rose toc/ fan and spry painting of ceiling fan with two coats of synthetic enemal paint complete all as specified and directed.
Supply and fixing, install, test and commissioning of LT Feeder pillar box indoor type totally enclosed with front opening hinged doors and raised platform of suitable sizes weather dust vermin proof made out of 2 mm thick stainless steel sheet, factory made powder coated as approved colour, aluminum bus bar suitable for 3 phase 4 wire LT, AC, 50Hz, 433 volts, 300 Amps rating capacity RYBN insulated with sleeved insulation complete with multifunctional meter LED type by showing Amps, volts, frequency etc along with suitable size of CT on outgoing, indicating lamp RYB , complete internal wiring with suitable size of PVC insulated copper conductor cable, including cable glands and lugs for incoming and out going cables as per required sizes, PCC platform made out of 1:2:4 type B1 and pedestal of 30 cm height from GL with suitable nut, bolts, washers etc., all as specified and directed for suitable to accomodate the following items including supply and fix following items and all as specified and directed by dismantling exisiting unserviceable LT panel complete with LT panel made by CPRI approved manufacturer . [a] MCCB 3 pole 160 Amps with breaking capacity 16 KA adjustable type with extended terminals - 01 Nos [Incoming] [b] MCCB 3 pole 125 Amps with breaking capacity 16 KA adjustable type with extended terminals - 02 No [c] MCCB 3 pole 63 Amps with breaking capacity 16 KA adjustable type with extended terminals - 01 [d] MCCB 3 pole 40 Amps with breaking capacity 16 KA adjustable type with extended terminals - 04 Nos Note: The rate quoted deemed to include the cost of dismantling the existing serviceable energy meters and fixing in new panel board.
Supply and fixing modular motor starter 25 Amp 2 module for AC complete all as specified and directed.
Supply installation, testing and commissioning of maintenance free Chemical Earthing of Dual Pipe Technology, each of 3 Meter long with Outer Pipe Diameter of 88mm (galvanised for 80-120 micron and wall thickness 1.80mm) and Inner Pipe diameter 48mm (galvanised for 80-120 micron and wall thickness 2.60mm). There shall be terminal of size 75 x 5.20mm for connection with two holes of 14mm diameter. Earthing shall be duly filled with the highly conductive, Non Magnetic, Non Corrosive material and duly sealed at both ends with lead terminal of 75x5.2mm at top. The ELECTRODE shall be of 'make' having approval of CPRI (Central Power Research Institute), Govt of India for a minimum short circuit current of 42 KArms for 1 Second with initial pick of 88.2 KA. The FAST ELECTRODE Earth Enhancing Compound (minimum 25Kg) shall be pored on alround the electrode. The chemical compound to be used shall be as per the manufacturer's instructions of 'Electrode' and as also certified by any BIS (Bureau of Indian Standards) accredited laboratory.Electrode connected to GI earth strip 32 x 6mm by mean of bolts, nuts, check nuts and washer of stainless steel all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including PCC pit and CI cover etc GI protection pipe of suitable size including testing on completion all as specified and directed. Notes:- (i) The contractor shall procure the above materials either directly from the manufacturer(s) or their authorised dealers only and shall produce the original purchase vouchers alongwith original manufacturer's test certificates and other authenticated documents in compliance of the provisions as mentioned in the above item. Also all the requisite testing as specified above, in relevant IS and as directed by the GE shall be got done by the contractor. Cost of all the above elements shall be deemed to be included in the contractor's quoted rates. (ii) Any additional quantity of Earth Enhancing Compound in case required to obtain the desired results, the same also be provided by the contractor without any additional cost to the Govt. and quoted rates of above item shall be deemed to include the above element also. (iii) Necessary earth strip to connect equipment shall also provided by the contractor .
Supply and fix in repairs MCB SPN 240 Volts 32 Amps breaking capacity 10 KA rating complete all as specified and directed.
Supply and laying in repairs cable LT XLPE insulated and screened PVC bedded, galvanised steel strip armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade complete all as specified and directed by Engineer in charge for the following sizes including taking down existing u/s LT cable of size 70 sqmm 3.5 core complete all as specified and directed.
Deduct Credit for Demolished/ Dismantled material Rs. (-) 63,605.00 (Minus) as listed in Schedule of Credit Note: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum'
GRAND SERVICES
the bhimani group of companies
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .