Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-AOC JODHPUR ROAD UTARLAI BARMER RAJ 344035 | BARMER | RAJASTHAN | 344035 | ₹9.7 L | L1 | Accepted-AOC ADMITTED |
| 2 | L2₹9.7 L+₹3,829 (0.40%)Accepted-AOC | ₹9.7 L+₹3,829 (0.40%) | L2 | Accepted-AOC ADMITTED |
| 3 | L3₹9.7 L+₹7,916 (0.82%)Accepted-AOC VILL JASSAI DISTRICT BARMER RAJ 344001 | JASSAI | BARMER | RAJASTHAN | 344001 | ₹9.7 L+₹7,916 (0.82%) | L3 | Accepted-AOC ADMITTED |
| 4 | L4₹9.8 L+₹17,007 (1.76%)Accepted-AOC CB 1 MAHAVEER NAGAR BARMER 344001 RAJ | BARMER | RAJASTHAN | 344001 | ₹9.8 L+₹17,007 (1.76%) | L4 | Accepted-AOC ADMITTED |
| 5 | L5₹10.3 L+₹67,833 (7.02%)Accepted-AOC | ₹10.3 L+₹67,833 (7.02%) | L5 | Accepted-AOC ADMITTED |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
25 Jan 2021, 6:00 pmClosed
GE(A) Barmer
Military Engineer Services, Garrison Engineer Army, Jalipa Mil stn, post box No. 53, Barmer-344001
REPAIR MAINTENANCE OF STREET SECURITY PERIMETER LIGHT SOLAR LIGHT OF ZONE A JASSAI UNDER GE ARMY BARMER
2021_MES_409361_1
GE(A)/BMR-59 OF 2020-21
Open Tender
Miscellaneous Works
Item Rate
270 days
GE(A) Barmer
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE ARMY BARMER
₹20,000
Yes
1 Apr 2021
4 Jan 2021
28 Jan 2021
4 Jan 2021
25 Jan 2021
11 Jan 2021
Amount
Disconnecting and taking down old unserviceable LED street light/high mast fitting of 100 watt street light fittings with brackets fixed on HT/LT poles, repairing after cleaning and replacing the un-serviceable parts like surge protector, LED driver , clamps etc and reinstallation / reconnecting after replacing wires / jumpers as required for proper functioning of street light fittings complete all as specified and as directed . Note : - Spare parts like surge protector, LED driver shall be measured and paid for as "Supply only" here-in-after.
All as per Item No. 1.00 above but LED street light of 90 watt.
All as per Item No. 1.00 above but LED street light of 60 watt.
All as per Item No. 1.00 above but LED street light of 45/48 watt.
All as per Item No. 1.00 above but LED street light of 25/30 watt.
Supply only electric driver for 25/ 30 watt LED fitting. Match with existing fitting, Model & Make
Supply only electric driver for 45 watt LED fitting. Match with existing fitting, Model & Make
Supply only electric driver for 60 watt LED fitting. Match with existing fitting, Model & Make
Supply only electric driver for 90 watt LED fitting. Match with existing fitting, Model & Make
Supply only electric driver for 100 watt LED fitting. Match with existing fitting, Model & Make
Supply only electric driver for 150 watt LED fitting. Match with existing fitting, Model & Make
Supply only surge voltage protector for 25/30 watt LED light fitting.
Supply only surge voltage protector for 45 watt LED light fitting. Match with existing fitting, Model & Make
Supply only surge voltage protector for 90 watt LED light fitting. Match with existing fitting, Model & Make
S&F in replacement of rigid PVC,LT line spacers for two line over head conductor, complete all as specified and as directed.
S&F in replacement of rigid PVC,LT line spacers for four line over head conductor, complete all as specified and as directed.
S& F in replacement of electric driver for 10/25/30 watt LED post top lantern/ bollard light fitting complete all as specified and as directed.
S&F in replacement of Decorative gate light made up of high grade unbreakable polycarbonate material suitable up to 20W LED lamp with B22 base including 15W LED lamp complete all as specified and directed. Make :- Havells Cat Part No LHFOGAE1T11F015 or techno commercially equivalent model of make Bajaj/Philips/CG
S&F in replacement bollard light fitting IP65 rated inverted pyramid tripod type LED 10W bollard with soft 360° light distribution along with connected items and mounting arrangement including connecting & testing complete all as specified and directed . Make : CG Cat Part No. LBLSN-10-CDL or Techno commercially equivalent model of make Bajaj/Philips/ Havells
S&F in replacement of post top 25W LED coral ( OPAL), IP 65 ,energy saving, environmental friendly, long life, aesthetically designed with symmetrical light distribution, warm white spun aluminium landscape luminaire with high power LED's as light source including connecting, testing and taking down unserviceable light fitting complete all as specified and as directed. Make : Havells Cat Part No.RUBYPT25WLED757PSYMTOPC or techno commercially equivalent model of make Philips / CG
Opening of un serviceable integrated solar street light of12/16/24W and removing the Li - ion battery and replace same with suitable capacity with minimum back up of 24 hrs complete all specified and as directed .
S&F in repair street light brackets made out of 40mm bore light grade GI tubing, bent to shape of length 1.50 metre fixed with suitable size of clamps, nuts, bolts etc all as required at site, complete all as specified and as directed.. Note : The rate quoted inclusive of cost of clamps, nut bolts etc as required.
Dismantling/disconnecting existing rusted/worn out MS clamps of any size and shape fixed on poles/street light brackets etc including nuts, bolts, washers etc complete all as specified and as directed.
Fabrication, supply and fixing MS clamps made out of MS flat iron 40x6mm thick, bent to shape for fixing of street light bracket on PCC poles complete with bolts, nuts, washers etc including painting of two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed..
Supply and errect steel tubular swaged poles type 410 SP-32 (8.5 metres long) complete with cast iron base plate and finial taper plug, bolts, nuts & screws complete all as specified and directed. Note: - (i) Excavation and earthwork,PCC shall be measured and paid separately in relevant item here in after . (ii) Painting with two coats of black bituminous paint throughout internally and externally upto plating depth and the remaining external complete pole portion shall be painted with silver colour in two coats over a red oxide primer and A1 graded radium strip of 100mm width in three colour red, yellow, and green fix around the pole with 100mm gap in each strip at a distance of 1.1 mtr high from the ground level deemed to be included in quoted rates.
Dismantling and removing damaged pole of any description including necessary excavation and earth work, demolition of PCC etc complete all as specified and as directed.
S&F in replacement of FRP pole mounting box weather proof BSES type of size 200mm x 140mm x 95mm hinge type with connector 4 way mounted inside complete all as specified and as directed.
M&L cement concrete 1:4:8 type D-2 by using 40mm graded crushed stone aggregate as in foundation filling and mass concrete,complete all as specified and as directed.
M&L cement concrete 1:3:6 type C-1 by using 20mm graded crushed stone aggregate as in copping including necessary form work complete all as specified and as directed.
Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5 mtr in depth for foundation of pole, taking out cable / pipe line etc and not exceeding 10 Sqm on plan and getting out in soft / loose soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5mtr wide and exceeding 1.5 mtr but not exceeding 3.00 mtr in depth for foundation of pole, taking out cable / pipe line etc and not exceeding 10 Sqm on plan and getting out in soft / loose soil complete all as specified and as directed.
Removing excavated materials( soils) to a distance not exceeding 50m depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in soils complete all as specified and directed.
Supply and spreading clean dry sand ( Tibba sand) in trenches for cushioning to PVC cable and punning to provide required cover to UG cable complete all as specified and directed . Note :- Punned thickness shall be measured for the purpose of payment.
Supply & Lay in trenches, fixing or passing through pole, fixed to wall / pole of 6 Sqmm 2.0 core XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty LT under ground cable 1100 volts grade with stranded aluminium conductor including providing lugs as required and connection, testing including taking down old cable complete all as specified and as directed.
Taking down 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and not less than 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified and as directed.
Supply & laying 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and not less than 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified and as directed.
Laying only 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and not less than 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified and as directed.
S&F in replacement of 2 core 4 Sqmm ,1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and over all PVC sheathed as in service connection complete all as specified and as directed.
Supply, fix ,connecting and testing of energy efficient, pressure die cast housing with heat resistant toughened glass and individual high power LEDs with secondary optics and IP-66 protection of street light luminaries 60 watt , impact resistance, fixed on pole including taking down unserviceable light fitting complete all as specified and as directed . Make : CG Cat Part No.LSTP-60-CDL or techno commercially equivalent model of make Bajaj/Philips/Havells
Supply, fix ,connecting and testing of energy efficient, pressure die cast housing with heat resistant toughened glass and individual high power LEDs with secondary optics and IP-66 protection of street light luminaries 45 watt , impact resistance, fixed on pole including taking down unserviceable light fitting complete all as specified and as directed . Make : CG Cat Part No.LSTS-45-CDL-M or techno commercially equivalent model of make Bajaj/Philips/Havells
Supply, Fix ,connecting and testing of LED flood light with innovative thermal management and in multiple optics and equipped with IP66 protection, ideal for stadium lighting and Highmast applications fixed on pole including taking down unserviceable light fitting complete all as specified and as directed. Make : CG Cat Part No. LFLN-120-CDL/60 or Techno commercially equivalent model of make Havells/Philips/Bajaj
S&F in replacement of automatic street light switch using NATURE SWITCH for automatic switching of street lights bases on LUX level of nature light . The sensor (nature switch) along with suitable power contactor, MCB and support terminals should be enclosed in pole / wall mounted enclosure made of rust proof, electric shock proof, termite proof and FR grade special moulding compound( SMC junction box of Syntex make) conforming to IP-54, for Single phase 12KW Model No.SWADEEP -02 EC 12K W1P including taking down unserviceableswitch complete all as specified and as directed.
Dismantling of old broken earth pit chamber and Renewing the earthing chamber pit of size 450X450X300mm ( external) & 250X250X250mm ( Internal) with PCC 1:3:6 type C-1by using 20 mm graded crushed stone aggregate and 40 mm thick RCC precast cover slab of 1:2:4 type B-1by using 20mm graded stone aggregat,e reinforced with 8mm TMT bars @ 100 mm C/C on both sides and replacing broken water/earth lead pipe, funal etc complete all as pecified and as directed .
Recharging of earthing pit using kalmi sora (Potashium permagnet), charcoal, salt, magnesium phasphet water and or using other chemical for obtaining the earth resistance within permissible limit and testing of earthing resistance of existing earth pits with different type of earth megger as to suit by disconnecting earth continuity conductor from test terminal block/panel, recording the results in triplicate duly signed by Contractor & MES rep and reconnecting the earth continuity conductor complete. Note : Earth maggers shall be arranged by Contractor at his own arrangement.
M&L for painting of earthing pit cover with two coats of black bituminious paint and making pit No. with synthetic enamel paint, complete all as specified and as directed .
Eearthing complete with galvanized steel earth plate electrode 60cm X 60cm X 6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized M.S. earth wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron mild steel all as shown in Electrical Plate No. 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 20mm dia light grade pipe and watering pipe shall be 15mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal / salt, funnel etc including taking down old earthing complete all as specified and as directed. Note: - (i) The concrete pit shall be PCC 1:3:6 type C-1, 40mm thick pre-cast cover slab of RCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate, reinforced with 8mm TMT bars @ 10 cm c/c on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in Electrical Plate No. 3 of MES SSR Part-I, (ii) Item includes the cost of GI pipe 15mm bore upto 7.50m for protection of earth wire/strip, (iii) Item includes the cost of earth lead wire/strip up to7.50m & (iv) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate quoted.
S& F in repairs to any type of light into Lithium base energy efficient integrated solar street light 12 watt in FRP body encases solar PV panel 25/30W monocrystallinn, Lithium battery 111/12.8V,15.4 AH with in built BMS, hogh brightness W-LED (140-160 1m/ watt) lamp, CRI 80, colour temperature 6500K, micro controller based charge controller cum +driver with automatic dimming function, dusk to down operation, LUX output 15-18( from 5-6mtr height) , working temperature (-) 10° c to (+) 55°c, weight 6-7 kg with adjustable MS clamp suitable for pole / wall mounting protection from short circuit, overload , reverse polarity and battery protections complete all as specified and as directed Make : Axxon / Orion / CG / Bajaj / Philips
Kusum Traders
m/s jogaram sujaram
M/S PRASHANT BENIWAL
m/s sai construction company,bijarar
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .