Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.6 LAccepted-AOC | L1 | Accepted-AOC REASONABLE | |
| 2 | L2₹10.6 L+₹92,480 (9.53%)Rejected-Finance | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹10.8 L+₹1.1 L (11.8%)Rejected-Finance | L3 | Rejected-Finance HIGH RATE |
Tender Value
₹9 L
Closing Date
30 Jun 2025, 6:00 pmClosed
Shri Tapan Das, AE (Civ)
AGE I AF SINGARSI
REPAIR REWINDING OF GEYSERS CEILING FANS EXHAUST FANS PEDESTAL FANS AT AF STN SINGARSI UNDER AGE I AF SINGARSI
2025_MES_711893_1
C/8761/E8
Open Tender
Civil Works
Item Rate
180 days
AGE I AF SINGARSI
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
AGE I AF SINGARSI
Yes
29 Jul 2025
2 Jun 2025
1 Jul 2025
2 Jun 2025
30 Jun 2025
15 Jun 2025
Amount
Taking down ceiling fan of 1200/1400mm sweep by unscrewing nut/bolts from its position and fixing the same to its original place after necessary cleaning, oiling, greasing, replacement of bush, bearing and marking MES number all as directed by Engr-in-charge. (Note : Bush, bearing , measured and paid separately as supply only rates and fixing charges for spare parts shall deemed to be included in this item.
M&L for Painting of ceiling fans, exhaust fans, pedestal fans, geysers complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc with the help of paint remover chemical with super glossy finish (grey/brown/white) and writing fan nos as directed by Engr-in-charge.
Dismantling complete exhaust fans 300/380/400/450mm sweeo, pedestal fans, ceiling fan of size 1200/1400 mm sweep down rod with its canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan, taking out starter, motor winding, ball bearing, gun metal bush etc. complete to carry out the following repairs :- (a) Removing of burnt out fan winding and re-winding of motor with suitable size of copper enamelled wire, varnishing, heating as per manufractures design and directed and re-assembling (b)New spare parts (i.e) rubber bush of shackle and condenser housing, gun metal bushes, ball bearing, twin twisted copper cable shall be measured and paid separately under relevant item,complete all as specified and as directed.
Supply and fixing rubber bush for shackle with bolt, nut and lock pin suitable for ceiling fan 1200/1400 mm sweep,complete all as specified and as directed.
Supply and fixing bearing number of 6201/6202/6203/6204 as required, Make : SKF/NBC or Eequivalent,complete all as specified and as directed.
Supply and fixing condenser 2/2.5 Mfd,complete all as specified and as directed.
Supply and fixing PVC holder for condenser housing,complete all as specified and as directed.
Supply and fixing twin core twisted copper flexible wire/cable of size 0.5 sqmm, single core,complete all as specified and as directed.
Supply and fixing only gun metal bush,complete all as specified and as directed.
Supply and fixing condenser 3.15/4 MFD (metal body) Make:Universal/Sarda or Equivalent,complete all as specified and as directed.
Supply and fixing louvers of exhaust fan 300/380 mm sizes made out of GI sheet of appropriate thickness .Fixing of exhaust fan louvers should be done with the help of anchor fastener nut bolts, Complete all as specified and as directed.
Supply and fix exhaust fan motor AC single Phase. 230V for size 300 mm sweep exhaust,complete all as specified and as directed.
Supply and fix exhaust fan motor AC single Phase. 230V for size 380 mm sweep , 150 watt exhaust,complete all as specified and as directed.
Supply and fix exhaust fan motor AC single Phase. 230V for size 450 mm sweep ,400 watts exhaust,complete all as specified and as directed.
Supply and fixing complete frame with side holding clamps with suitable nuts/bolts for exhaust fan 300/380 mm sweep as per existing make/size,complete all as specified and as directed.
Supply & fixing blade made of iron suitable for Exhaust fan 300/380 mm sweep,complete all as specified and as directed.
Taking down / dismantling of defective / rusted storage type hot water gyser of 50/25 ltr capacity from different locations by disconnecting inlet / outlet connections and taking out unserviceable parts by unscrewing bolts and nuts etc deiscaling / cleaning inner servicing and etc. Checking defects, re-assembling and re-installing the gyser in position, connection and testing complete,complete all as specified and as directed.
Supply & fix indication lamp (green / red) as required,complete all as specified and as directed.
Supply& fix thermostat of range 0-90 degree centigrade as required,complete all as specified and as directed.
Supply& fix heating element 2 KW (ISI Marked) cup type / thread type with the provision of thermal cut out as required. ,complete all as specified and as directed.
Supply& fix inner ss tank of cap 25 ltr,complete all as specified and as directed.
Supply& fix PCB universal type suitable for 25 / 35 Ltr Geyser,complete all as specified and as directed.
S&F for PVC flexible pipes 15mm dia (heavy duty) both end socketed 450mm long for cold water,complete all as specified and as directed.
S&F hot water pipe for gyser, connection with check nuts and washers,complete all as specified and as directed.
S&F in replacement of gun metal non return valve of 15mm dia ISI marked,complete all as specified and as directed.
S&F in replacement of stop cock brass of 15mm dia,complete all as specified and as directed.
S&F gun-metal, globe or gate valves 15mm dia, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and as directed.
S&F in replacement of GI tubing medium grade 15mm dia with all fittings and fixed to wall, ceiling or roof, complete all as specified and directed.
S&F in fastner with nuts and bolts complete to hang properly and bear the water filled geyser weight,complete all as specified and as directed.
Taking down carefully unserviceable copper / aluminium point wiring (light, fan, bell socket or power) including all fittings such as switches, socket, ceiling roses , regulators and fittings complete and making good the disturbed surfaces,complete all as specified and as directed.
M&L for point wiring for one light/fan/bell with single core PVC insulated and unsheathed stranded FRLS copper conductor cable 1100 volts grade size 1.5 Sqmm (nominal area) in and including PVC casing capping 25/20 mm width with one single core PVC insulated unsheathed 1.5 Sqmm (nominal area) stranded FRLS copper conductor as earth continuity wire and connected to earth dolly including PVC/wooden switch board on existing wall surface for one light/fan point /bell point controlled by one number one way switch & making good the disturbed surface to match with existing surface/wall, complete all as specified and as directed.
All as per Item No 31 here-in-before but for one 5 pin socket outlet 5 Amps on independent board with 1.5 Sqmm, complete all as specified and as directed.
All as per item No 31 here-in-before but for one 5 pin socket outlet 5 Amps on the same board with other switches complete all as specified and as directed.
All as per Item No 31 here-in-before but for one 5 pin socket outlet 15 Amps on independent board with 2.5 Sqmm copper cable FRLS & 1.5 Sqmm FRLS copper cable for earth continuity wire, complete all as specified and as directed.
S&F sub main wiring with 2 run of 2.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable FRLS working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including heavy duty rigid non-metallic PVC casing/caping (25mm dia) including size 2.5 sqmm (nominal cross sectional area) PVC insulated un-sheathed single core multi stranded copper conductor cable as earth continuity conductor connected to main switches/DB"S or common earth dully complete all as specified and directed after taking down old sub main wiring complete and making good the disturbed surface complete all as specified and as directed. ( NOTE :- Two runs of 2.5 Sqmm pvc wire, one run of 2.5 Sqmm pvc wire and one run of pvc casing caping/ PVC conduit will be measured as one unit,complete all as specified and as directed.
Supply and fixing sub main wiring with two run of single core 4 Sqmm PVC insulated unsheathed stranded cable (FRLS) copper conductor drawn through PVC casing caping with all fittings including 4.0 sq mm PVC insulated unsheathed single core copper conductor as earth wire and including PVC casing caping after taking out old un serviceablewring complete and including PVC casing caping,complete all as specified and as directed. Note : (i) Two run of single core cable 4 sq mm and one run earth wire 2.5 sq mm will be measured as one length.(Make: RR,KEI and Finolex for copper Cable and Prestoplast/Plaza for casing/conduit)
S&F for switch piano flush type 6 Amp single pole one way, complete all as specified and as directed.
S&F for socket flush type 6 Amp 5 Pin complete complete all as specified and as directed.
S&F for switch socket combination 5 Pin 6 Amp universal, complete all as specified and as directed.
S&F for switch socket combination 5 Pin, 6/15 Amp universal, complete all as specified and as directed.
S & F ceiling rose, 3 phase/PVC/Polycarbonate, isolated body, complete all as specified and as directed.
S & F call bell, ding dong AC 230 volts, single pole, complete all as specified and as directed.
S & F bell push, flush type, 5 amp, complete all as specified and ad directed.
S&F sheet metal enclosures for DB’s double door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 4 way with built in bus bar complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour,complete all as specified and as directed. (Make:Havells ,Hager,Schneider or Legrands).
S&F sheet metal enclosures for DB’s double door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 8 way with built in bus bar complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour,complete all as specified and as directed. (Make:Havells ,Hager,Schineder or Legrands).
M&L for MCB, SP, 240V,40 Amps and ' B ' series breaking capacity 10 KA ISI marked,complete all as specified and as directed.
M&L for MCB, SP, 240V, 6 to 32 Amps and ' C ' series breaking capacity 10 KA ISI marked , complete all as specified and as directed.
M&L for MCB, SPN, 240 V, 40 to 63A Amps, and ‘C’ series breaking capacity 10 KA complete ISI marked,complete all as specified and as directed.
Supply and fix ceiling fan regulator electronic Step type, solid state, 120W, 2 module, 240 volts, complete all as specified and as directed.
S&F metal clad box enclosure with socket plugtop and MCB SP 20 Amp flush of 240v mounting enclosure with 2 pin earth plug socket,complete all as specified and as directed.(Make - Havells Hager/legrand)
S&F in repair for wall mounted LED 4 feet 20 Watt fittings with high diffuser , driver holder extruded aluminium heat sink provided for energy efficient heat dissipation &integrated electronic incl all accessories and lamp ,internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed by Engr-in-charge. (Make :Crompton , Bajaj/Philips/Havells)
S&F in repair for wall mounted LED 2 feet 10 Watt fittings with high diffuser , driver holder extruded aluminium heat sink provided for energy efficient heat dissipation &integrated electronic incl all accessories and lamp ,internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size,complete all as specified and as directed by Engr-in-charge. (Make :Crompton , Bajaj/Philips/Havells)
M&L for earthing complete with galvanised steel earth plate electrode 600x600x 6mm thick burried in ground (earth pit not less than 2.25 m deep below ground level0with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip 25x4 mm as earthing lead by means of bolts, nuts, check nuts, and washers of GI or steel, GI strip protected by 40 mm bore medium grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade GI, wire mesh charcoal or coke common salt laid in altrnative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC(1:3:6) type C-1, 50 mm thick pre-cast RCC(1:2:4) type B-1 normally mix cover slab reinforced with in 8 mm dia TMT bar 10 cm C/C both ways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft/loose/hard soil and disposal of soil to a distance n.exc 50 m and necessry testing on completion all as shown in electrical plate No 3 MES schedule part-I, complete all as specified and as directed.
M/S New Builders Corporation (BID ID -3340712)
DANATION CONSTRUCTIONS (BID ID -3340328)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .