Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹26.3 L+₹2.4 L (9.95%)Rejected-Finance | L2 | Rejected-Finance Not Being Lowest Bidder | |
| 3 | L3₹29.5 L+₹5.6 L (23.2%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹76,000
Closing Date
12 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/MAINTENANCE STAND BY POWER SUPPLY ASSETS IN THE AREA OF AGE E/M EXT (ELECT) UNDER GE E/M LUCKNOW
2021_MES_423255_2
GE/EM/LKO/EXT(ELECT)/T-88 OF 2020-2021
Open Tender
Miscellaneous Works
Item Rate
180 days
Lucknow
Class D or above category b (i)
8 documents required · 8 mandatory
₹500
Yes
GE E/M Lucknow
₹76,000
Yes
28 Jul 2021
22 Mar 2021
14 Apr 2021
22 Mar 2021
12 Apr 2021
31 Mar 2021
60 days
Amount
Supply, installation, testing and commissioning out door type LT Feeder Piller/LT panel made out of 3.15 mm thick MS sheet duly powder coated and MS angle section 40x40x5 mm on PCC 1:2:4 type B-1 platform , frame factory fabricated with front and back openable double door system lockable/openable by Keys completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz comprising of the following :- (a) Incomming (i) MCCB 4P 630 Amps 50 KA with thermal magnatic-thermal release b) Digital volt meter (0-500)- 01 No c) Digital Ammeter with CT (0-600)-01 No d) Slector switch with togal switch -03 Nos (e) Copper Busbar suitable capacity-04 Nos (b) Outgoing (i) Change over switch 630 Amp 4 pole-01 Nos (ii) MCCB 4P 200 Amps 35 KA thermal magnatic and thermal release-01 No (iii) MCCB 4P 400 Amps 35 KA with thermal magnatic and thermal release-02 No (iv) MCCB 4P 100 Amp 25 KA with thermal & magnatic release-01 (v) Cable tray as per existing type/Model (vi) Busbar chambere as per exiting type/model f) Provn of blank compartment for future uses, 415 volts, FP - 01 No g) LED indicator lamp RYB - 01 Set of three
Repairing to Dynamo/alternator assembly of 12 Volts/24 Volts from the DG sets replacing the spare parts such as carbon brushes, springs, spring holders, brushes, bearings or any other part required for full functioning, etc and fixing the same complete all as specified and directed by Engineer-in-Charge.
Rewinding of armature of Dynamo/alternators dismantling the old coil, cleaning thoroughly and wound with new super enameled copper cord of existing size and gauge, varnishing, drying etc, and fixed with dynamo/alternator properly testing and commissioning complete all as specified and directed by Engineer-in-Charge.
Oil pressure gauge of existing size and model for any make/model/ capacity of DG sets including taking down old one etc , complete all as specified and directed by Engineer-in-Charge.
AVR unit /CVR –II for 320/250/200 DG Set & testing including taking down old one etc , complete all as specified and directed by Engineer-in-Charge. Make : Kirloskar/Cummins or any other equivalent make approved by GE
AVR unit /CVR –II for 125KVA/110KVA/100KVA DG Set and testing including taking down old one etc , complete all as specified and directed by Engineer-in-Charge. Make : Kirloskar/Cummins or any other equivalent make approved by GE
AVR unit /CVR –II for 82.5KVA/63KVA/62.5KVA DG Set and testing including taking down old one , complete all as specified and directed by Engineer-in-Charge. Make : Kirloskar/Cummins or any other equivalent make approved by GE
Battery terminal made of brass superior quality including taking down old one etc , complete all as specified and directed by Engineer-in-Charge.
PVC heavy duty transparent pipe of size 10 mm dia for Diesel tank indicator with suitable clamps fixed on any type of tank including taking down old one etc , complete all as specified and directed by Engineer-in-Charge.
Controller for electronic control panel for DG Set upto 125 kva in repairs complete all as specified and directed by Engineer-in-Charge.
DG set canopy by replacing of door hinges and locking arrangement in repairs complete all as specified and directed by Engineer-in-Charge.
PVC pipe of size 25 mm dia heavy duty for fol distibution complete all as specified and directed by Engineer-in-Charge.
Empty Barrel heavy duty made of steel of 220 ltr capacity for collection of a FOL complete all as specified and directed by Engineer-in-Charge.
Supply and spread river sand including removing of old diesel wetted sand from FOL store complete all as specified and directed by Engineer-in-Charge.
Cleaning by desludging of fuel tank of DG Set by including out going and over flowing pipe and replacement of fuel indicator pipe including make locking arrangement of tank ,painting of tank complete all as specified and directed by Engineer-in-Charge.
Rotating rectifier assembly for 320/250/200 KVA DG set of any make and model, complete all as specified and directed by Engineer-in-Charge.
Rotating rectifier assembly upto 125/110/100 KVA DG set of any make and model , complete all as specified and directed by Engineer-in-Charge.
Rotating rectifier assembly upto 82.5/63/62.5 KVA DG set of any make and model , complete all as specified and directed by Engineer-in-Charge.
Rectifier diode for 250/200 KVA DG sets as per exising make/model/ size including taking down old one etc , complete all as specified and directed by Engineer-in-Charge
Rectifier diode for 125/110/100 KVA DG sets as per exising make/ model /size including taking down old one etc , complete all as specified and directed by Engineer-in-Charge
Rectifier diode for DG sets upto 82.5 KVA capacity as per exising make/size/ model including takding down old one etc , complete all as specified and directed by Engineer-in-Charge
Voltmeter square/ round upto 500 Volts of existing size including taking down old one, complete all as specified and directed by Engineer-in-Charge
Ammeter 0-300A as per existing size/make/model including taking down old one etc , complete all as specified and directed by Engineer-in-Charge
Indicator lamp assembly 230/110 Volts as per existing make/model/size etc , complete all as specified and directed by Engineer-in-Charge
Battery leads 95 Sqmm copper cable 1.5 Mtr long including brass terminals of suitable size socket with nut, bolts etc , complete all as specified and directed by Engineer-in-Charge.
Supply only coolant concentrate Pert No SK 802 OIC, complete all as specified and directed by Engineer-in-Charge. Make :- Valvoline or any other equivalent make approved by GE
Electronic control timer type ET-100 of suitable capacity as required at site including taking down old one , complete all as specified and directed by Engineer-in-Charge. Make:- L&T or equivalent make as approved by GE
Engine starter relay of suitable capacity as required at site including taking down old one , complete all as specified and directed by Engineer-in-Charge. Make:- L&T or equivalent make as approved by GE
Under voltage relay including taking down old one including taking down old one. complete all as specified and directed by Engineer-in-Charge. Make:-PIC / EC / Wader or equivalent make as approved by GE
Pin relay 8/11 including taking down old one, complete all as specified and directed by Engineer-in-Charge. Make:- PLA or equivalent make as approved by GE
Auto Mains Failure (AMF) relay as per existing model and make of AMF panels of DG sets of any capacity including taking down old one , complete all as specified and directed by Engineer-in-Charge.
Recharging of old serviceable battery 12 Volts, 180 AH rating including cleaning complete and filling with acids and distile water as required and testing , complete all as specified and directed by Engineer-in-Charge.
Recharging of old serviceable battery 12 Volts, 150 AH rating including cleaning complete and filling with acids and distile water as required and testing , complete all as specified and directed by Engineer-in-Charge.
Rrecharging of old serviceable battery 12 Volts, 88 AH rating including cleaning complete and filling with acids and distile water as required and testing , complete all as specified and directed by Engineer-in-Charge.
Crocodile clip for battery chargers of required size all as specified and directed including taking down old one , complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in replacement, testing off load changeover switch 63 Amps TPN with sheet metal enclosure ,side handle operated, 50 Hz, fixed to walls/ panels with suitable size clamps, nuts, bolts and washers including making connections and testing of following capacities, complete all as specified and directed by Engineer-in-Charge
All as per Item No 37 above but 100 Amps
All as per Item No 37 above but 200 Amps
Supply & Fixing in repairs "ON LOAD" type Change over switch 630 Amps TPN front handle operated, on existing LT/AMF Panels, suitable for three phase, 415V, 50 Hz AC supply of following ratings, complete all as specified and directed by Engineer-in-Charge.
All as per Item No 40 above but 315 Amps
All as per Item No 40 above but 250 Amps
All as per Item No 40 above but 200 Amps
All as per Item No 40 above but 100 Amps
All as per Item No 40 above but 63 Amps
Supply only distill water for batteries, complete all as specified and directed by Engineer-in-Charge.
Battery charger heavy duty type with voltmeter and ammeter, with copper wound transformer, suitable for charging 12 Volts 180 AH battery, complete all as specified and directed by Engineer-in-Charge.
Battery charger heavy duty type with volteter and ammeter, with copper wound transformer, suitable for charging 02 Nos 12 Volts 180 AH battery , complete all as specified and directed by Engineer-in-Charge.
Power contactor 4NO assembly of capacity 150 AMPS, 3 /4 Pole, AC 415 Volts, 50 Hz for AMF panel boards including taking down old one, complete all as specified and directed by Engineer-in-Charge.
Power contactor 4NO assembly of capacity 200 AMPS, 3 Pole, AC 415 Volts, 50 Hz for AMF panel boards including taking down old one, complete all as specified and directed by Engineer-in-Charge.
Power contactor 4NO assembly of capacity 400 AMPS, 3 Pole, AC 415 Volts, 50 Hz for AMF panel boards including taking down old one, complete all as specified and directed by Engineer-in-Charge.
Supply, laying, jointing, testing, XLPE insulated PVC sheathed stranded aluminium conductor, heavy duty, conforming to IS 1554 Part I / ISI marked, including suitabe size cable glands & lugs, cables to be laid in trenches, fixed along the poles /or through GI pipe laid under floors road etc complete of sizw 300 sqmm 3.5 core incl taking down old one, complete all as specified and directed by Engineer-in-Charge.
All as per Item No 52 above but 240 Sqmm 3.5 Core
All as per Item No 52 above but 95 Sqmm 3.5 Core
All as per Item No 52 above but 70 Sqmm 3.5 Core
MCCB 4 Pole of capacity 125 Amps, 50 Hz, 415V with rupturing capacity of 16 KA with fixed thermal magnetic settings including spreader terminals complete incl taking down old one etc, complete all as specified and directed by Engineer-in-Charge.
MCCB 4 Pole of capacity 160 Amps, 50 Hz, 415V with rupturing capacity of 25 KA with fixed thermal magnetic settings including spreader terminals incl taking down old one etc, complete all as specified and directed by Engineer-in-Charge.
MCCB 3 Pole of capacity 200 Amps, 50 Hz, 415V with rupturing capacity of 35 KA with fixed thermal magnetic settings including spreader terminal including taking down old one, complete all as specified and directed by Engineer-in-Charge.
MCCB 3 Pole of capacity 250 Amps, 50 Hz, 415V with rupturing capacity of 35 KA with fixed thermal magnetic settings including spreader terminals including taking down ole etc, complete all as specified and directed by Engineer-in-Charge.
MCCB 3 Pole of capacity 400 Amps, 50 Hz, 415V with rupturing capacity of 50 KA with fixed thermal magnetic settings including spreader terminals incl taking down old one etc, complete all as specified and directed by Engineer-in-Charge.
DG set fuel UPVC pipe 15 mm bore by replacing including elbow, tee , socket etc in repairs, complete all as specified and directed by Engineer-in-Charge.
Self Starter 24 Volt, DC for DG Set of capacity upto 320 KVA including testing , complete all as specified and directed by Engineer-in-Charge . Make of DG Set Kirloskar/Cummins as per existing size and make.
Servicing/ maintenance of DG Set from authorised representative or service engineer from the manufacturer of DG set of capacity 320 KVA such as injector & valve tappet setting, checking of vibration damper, checking turbo charger, oil leakage, tightening mounting screws & nuts, replacment of filters & oil, checking inlet & exhaust manifold capscrews, checking of fan hub & water pump, removing the existing engine oil, clean the oil sump and refilling with directed quantity of new oil & coolant top up, cleaning of radiator inside with solution i.e restore plus and outside thoroughly with solution(caustic soda with water) including trial and testing etc, complete all as specified and directed by Engineer-in-Charge. NOTES :- (i) Labour for assembling of old/serviceable and new parts to make the DG set in serviceable condition shall be included under this item. (ii)Spare/parts renewed shall be measured and paid separately under appropriate items here in after as supply only labour for fixing shall be included in quoted rate of this item and nothing extra shall be admissible on this account.
Supply only Element for lubrication oil filter for 62.5/63/82.5 KVA DG sets
Supply only Element of paper bypass filter for 62.5/63/82.5 KVA DG sets
Supply only Element for fuel filter for 62.5/63/82.5 KVA DG Sets
Supply only Element for air cleaner inner for 62.5/63/82.5 KVA DG Sets
Supply only Element for air cleaner outer for 62.5/63/82.5 KVA DG Sets
Supply only Filter screen for 62.5/63/82.5 KVA DG Sets
Excavation in trenches, n. exc 1.5 m wide and n. exc 1.5m depth and getting out in for foundation of pole,stay,laying of cable and pipe in any type of soil etc , complete all as specified and directed by Engineer-in-Charge.
All as per item No 70 above but depth exceeding 1.5 and not exceeding 3 metres
Returing, filling in incl spreading, levelling, watering and well ramming in layers n exc 25cm thick after laying of the cables,jointing & testing , complete all as specified and directed by Engineer-in-Charge.
Removing excavated material to a distance n.exc 50 m & depositing where directed at a level n. exc 1.50 m above the starting point , complete all as specified and directed by Engineer-in-Charge.
CI funnel made as specified in SSR Part -I electrical plate No 3 fixed with fixed with GI pipe of watering by welding or threading etc in repairs, complete all as specified and directed by Engineer-in-Charge.
Galvanised steel tubing 20 mm bore light grade with all fittings in earthing for watering the earth including taking down of old steel tubing, complete all as specified and directed by Engineer-in-Charge.
Galvanised iron strip as earth continuity conductor or main earthing lead fixed to walls or burried in ground of size 32x6 mm, complete all as specified and directed by Engineer-in-Charge.
GI plate of size 60cmx60cmx6mm suitable for earthing & fixed with 3 Nos GI nut bolt and washer incl making hold for nut & bolt including taking down old one etc, complete all as specified and directed by Engineer-in-Charge.
Pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover, reinforced with 6mm dia bars 3 Nos both way with 12mm dia round bar handle, earth pit cover as per existing size including necessary formwork, complete all as specified and directed by Engineer-in-Charge.
Earth pit chamber PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover, reinforced with 6mm dia bars 3 Nos both way with 12mm dia round bar handle as specified in SSR 2009 Part I Electrical Plate No 3 incl taking down old one and deposited brocken pit cover as directed place etc, complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I, complete all as specified and directed by Engineer-in-Charge. and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Cleaning and day to day maintenance of DG Set installation by using cotton waste -10 kg, yellow cloth 1x1 meter size-05 nos, two rin soap of 300 gm and two broom stick -04 for cleaning DG Set installation, complete all as specified and directed by Engineer-in-Charge.
Thermal over load relay suitable for MN 30-50 relay range incl taking down old one etc, complete all as specified and directed by Engineer-in-Charge.
Spreader terminal suitable of 3 pole change over switch any capacity incl taking down old one etc, complete all as specified and directed by Engineer-in-Charge.
Rotor handle direct/extended as per site requirement incl taking down old etc, complete all as specified and directed by Engineer-in-Charge.
Auxilary contact suitable MCCB incl taking down old one etc, complete all as specified and directed by Engineer-in-Charge.
Auxilary contact + trip alram contact suitable MCCB incl taking down old one etc, complete all as specified and directed by Engineer-in-Charge.
Shunt release suitable for 415 AC suitable for MCCB incl taking down old one etc, complete all as specified and directed by Engineer-in-Charge.
VAF meter as per existing make,model & capcity etc, complete all as specified and directed by Engineer-in-Charge.
Push button as per existing make,model & capaicty etc, complete all as specified and directed by Engineer-in-Charge.
Cotton waste/cotton cloth for maintenance of DG set, complete all as specified and directed by Engineer-in-Charge.
Radiator hoses of any size and any capacity including jublee clips, clamps, nuts etc complete properly fixed and connected and testing incl as directed by Eng-in-charge and taking down old one etc, complete all as specified and directed by Engineer-in-Charge.
Dismantling and taking out the FIP (PT Pump Assy) for repairing by replacing the worn out gasket, filter, suction valve, discharge valve and fixing the same after calibration and testing of capacity 200 KVA / 250 KVA/320KVA DG set, complete all as specified and directed by Engineer-in-Charge. Note : Repairing & Calibration shall be carried out by authorised dealers only.
As per item No 93 above but for DG set of capacity 125KVA/110KVA/100KVA
As per item No 93 above but for DG set of capacity 82.5KVA/63KVA/62.5KVA
As per item No 93 above but for DG set of capacity 40KVA/30KVA/25KVA /20KVA/ 15KVA
Overhauling /calibration of injector assembly for any make /model/ capacity of DG sets including renewal of worn out parts such as copper gasket, injecter nozzle and testing including taking down old one , complete all as specified and directed by Engineer-in-Charge. Note :- Repairing/Calibration shall be carried out by authorised dealer only.
Dismantling and taking out the water body pump assembly complete from the DG set upto capacity 62.5 KVA at site and transporting to the work shop for repair and refixed the same after repair & testing , complete all as specified and directed by Engineer-in-Charge after replacement of the following parts:-. (a) Over hauling of water body pump complete - 01 Job, (b) Supply and fix water body kit complete- 01 Set, (c) water body bearing - 02 Nos, (d) water body Hose- 01 Set,
Dismantling and taking out the water body pump assembly complete from the DG set upto capacity 82.5 KVA to 125 at site and transporting to the work shop for repair and refixed the same after repair & testing, complete all as specified and directed by Engineer-in-Charge after replacement of the following parts:-. (a) Over hauling of water body pump complete - 01 Job, (b) Supply and fix water body kit complete- 01 Set, (c) water body bearing - 02 Nos, (d) water body Hose- 01 Set,
Dismantling and taking out the water body pump assembly complete from the DG set upto capacity 200 to 320 KVA at site and transporting to the work shop for repair and refixed the same after repair & testing , complete all as specified and directed by Engineer-in-Charge after replacement of the following parts:-. (a) Over hauling of water body pump complete - 01 Job, (b) Supply and fix water body kit complete- 01 Set, (c) water body bearing - 02 Nos, (d) water body Hose- 01 Set, NOTES for item No. 34 to 37 :- (i)Transportation charges from installation to contractor works shop and back after repair are included in the rates quoted against this item and nothing extra shall be admisible on this account. (ii) Labour for assembling of old/serviceable and new parts to make the pump in serviceable condition shall be included under appropriate item here in after. (iii) Spare/parts renewed shall be measured and paid separately under appropriate items here in after.
Draining out old engine/lubrication oil from chamber of the DG sets, cleaning of chamber thoroughly and filling new engine/lubrication oil of grade 15W40 , complete all as specified and directed by Engineer-in-Charge.
Taking down radiator from Gen set of capacity 200/250/320 KVA after disconnecting the water connecting pipe and descaling, cleaning properly with high pressure wash to remove greasy substances from water tubes, tank and outer fins and re-fixing the same after servicing complete and replacement of coolant solution and hose radiator with clips , complete all as specified and directed by Engineer-in-Charge.
Taking down radiator from Gen set of capacity 100/110/125 KVA after disconnecting the water connecting pipe, descaling, cleaning properly with high pressure wash to remove greasy substances from water tubes, tank and outer fins and re-fixing the same after servicing complete and replacement of coolant solution and hose radiator with clips , complete all as specified and directed by Engineer-in-Charge.
Taking down radiator from Gen set of capacity 62.5/63/82.5 KVA after disconnecting the water connecting pipe, descaling, cleaning properly with high pressure wash to remove greasy substances from water tubes, tank and outer fins and re-fixing the same after servicing complete and replacement of coolant solution and hose radiator with clips , complete all as specified and directed by Engineer-in-Charge.
Taking down radiator from Gen set of capacity 30/40 KVA after disconnecting the water connecting pipe, descaling, cleaning properly with high pressure wash to remove greasy substances from water tubes, tank and outer fins and re-fixing the same after servicing complete and replacement of coolant solution and hose radiator with clips , complete all as specified and directed by Engineer-in-Charge.
Taking down radiator from Gen set of capacity 15/20/25 KVA after disconnecting the water connecting pipe, descaling, cleaning properly with high pressure wash to remove greasy substances from water tubes, tank and outer fins and re-fixing the same after servicing complete and replacement of coolant solution and hose radiator with clips , complete all as specified and directed by Engineer-in-Charge.
Oil pressure gauge of existing size and model for any make/model/ capacity of DG sets including taking down old one etc , complete all as specified and directed by Engineer-in-Charge.
Dismantling and taking out of defective water pump assembly from the the DG sets and supply and fix new water pump assembly for the DG sets of capacity 125KVA/110KVA/100KVA including testing , complete all as specified and directed by Engineer-in-Charge.
Dismantling and taking out of defective water pump assembly from the the DG sets and supply and fix in repairs new water pump assembly for the DG sets of capacity 82.5KVA/63KVA/62.5KVA including testing , complete all as specified and directed by Engineer-in-Charge.
Dismantling and taking out the self starter assembly of any capacity (12V/24V) foRunning Metre the DG set and Material and labour for re-fixing the same after repair works including replacing the spare parts such as carbon brushes, springs, spring holder bushes, bearings, or any other spare part not mentioned herein but essentially required for proper functioning of the starter assembly , complete all as specified and directed by Engineer-in-Charge.
Dismantling and taking out armetreature of self starter for rewinding and taking out unserviceable old coil , cleaning thoroughly and rewinding the starter with super enameled copper conductor of existing size and gauge including varnishing drying and re-fixing the same including testing and commissioning , complete all as specified and directed by Engineer-in-Charge.
Repair to radiator of 320/250/200 KVA DG set by soldering of copper pipes rectifying leaks, cleaning and PVC hose fitting complete and fixing back after repair, complete all as specified and directed by Engineer-in-Charge.
Repair to radiator of 125/110/100 KVA DG set by soldering of copper pipes rectifying leaks, cleaning and PVC hose fitting complete and fixing back after repair, complete all as specified and directed by Engineer-in-Charge.
Repairs to radiator of 82.5/63/62.5 KVA DG set by soldering of copper pipes rectifying leaks, cleaning and PVC hose fitting complete and fixing back after repair , complete all as specified and directed by Engineer-in-Charge.
Fuel feed pump for DG set of capacities upto 250 KVA all as specified including taking down old one including testing , complete all as specified and directed by Engineer-in-Charge.
Material and labour for servicing/repair of AMF panel of DG set upto 250 KVA capacity for smooth functioning of the same with renewal / repairs of AMF panel wiring, control timer, engine starting relay, contact point relay, AMF relay, HRC fuse of existing rating etc complete for DG sets installed at various pokets , complete all as specified and directed by Engineer-in-Charge. Note:- 1. The rates quoted by the contractor shall deemed to included the cost of spares/relays or any other part not mentioned herein but essentially required to make the AMF Panel completely functional and no extra payments shall be made for the same.
Lead acid battery 12 volts, 180 AH suitable for DG set including initial charging including connection & testing and taking down old one etc , complete all as specified and directed by Engineer-in-Charge. Make : Model No. FXPO-MHD1800 Exide New express /Amron or equivalent of other makes specified in Annexure of make .
Lead acid battery, 12 volts, 150 AH suitable for DG set including initial charging including connection & testing including taking down old one etc , complete all as specified and directed by Engineer-in-Charge. Make : Model No. FXPO-MHD1500 Exide New express/Amron or equivalent of other makes specified in Annexure of make .
Lead acid battery, 12 volts, 110 AH with lead acid suitable for DG set including initial charging including connction and testing including taking down old one , complete all as specified and directed by Engineer-in-Charge. Make : Model No. FXPO-MHD1100 Exide New express/Amron or equivalent of other makes specified in Annexure of make .
Prime power system
DEV INFRATECH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .