Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.2 LAccepted-AOC SHIVAJI NAGAR GALI NO 1 DHANGU ROAD MODEL TOWN PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹25.9 L+₹2.7 L (11.5%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹28.5 L+₹5.3 L (22.8%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹28.6 L+₹5.3 L (22.9%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹29.0 L+₹5.7 L (24.6%)Rejected-Finance 99 MODEL TOWN PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
21 Aug 2019, 6:00 pmClosed
GE South Pathankot
GE South Pathankot
Certain repairs to cooling towers, ahus, chiller/condenser units, window/split ACs, desert coolers and other allied works at Dhangu, Bhadoria, Damtal, Nangal, Mirthal, Kandrori and Kaunterpur complex areas under GE (South) Pathankot.
2019_MES_267824_1
GES/PKT/T-14/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Damtal, Nangal, Mirthal, Kandrori Kaunterpu
Refer tender documents and NIT
9 documents required · 9 mandatory
₹500
GE South Pathankot
₹60,000
Yes
11 Mar 2020
17 Jul 2019
22 Aug 2019
17 Jul 2019
21 Aug 2019
1 Aug 2019
17 Jul 2019 - 23 Jul 2019
Amount
Material and labour for carrying out servicing/overhauling , repairs and maintenance of Cooling tower of 34 TR DX type central AC plant by dismanlting /taking down the CT fan motor of flange mounted extended type shaft upto 2 HP, 3 phase, 415 volts, 50 Hz, along with fan assembly, and including cleaning & removal of scales, inspection, cleaning and replacement of PVC fills, PVC eliminator, FRP louvers, motor cover, splash cups etc complete including renewal of all corroded bolts & nuts, terminal block, and re-assembling, fixing in position, fixing of fan blade, and alignment of the fan blade for the suitable air throw of the cooling tower,painting with two coats of synthetic enamel paint over a coat of anticorrosive paint after preparation of surfaces, testing & commissioning the cooling tower motor all as specified and as directed by the Engineer-in-Charge.
(a) The spares such as PVC fills, Fan assembly, CT fan motor, elimintaor, louvers, motor cover, branch pipe, splash cups etc deemed to be included in the quoted rate. (b) The rates inclusive for all T&P, chemicals required for cleaning, FRP compound, nut bolts etc complete for keeping the Cooling tower in operational condition.
Material and labour for carrying out servicing/overhauling , repairs and maintenance of Cooling tower of 48 TR Water cooled chiller type central AC plant by dismanlting /taking down the CT fan motor of flange mounted extended type shaft upto 2 HP, 3 phase, 415 volts, 50 Hz, along with fan assembly, and including cleaning & removal of scales, inspection, cleaning and replacement of PVC fills, PVC eliminator, FRP louvers, motor cover, splash cups etc complete including renewal of all corroded bolts & nuts, terminal block, and re-assembling, fixing in position, fixing of fan blade, and alignment of the fan blade for the suitable air throw of the cooling tower,painting with two coats of synthetic enamel paint over a coat of anticorrosive paint after preparation of surfaces, testing & commissioning the cooling tower motor all as specified and as directed by the Engineer-in-Charge.
(a) The spares such as PVC fills, Fan assembly, CT fan motor, elimintaor, louvers, motor cover, branch pipe, splash cups etc deemed to be included in the quoted rate. (b) The rates inclusive for all T&P, chemicals required for cleaning, FRP compound, nut bolts etc complete for keeping the Cooling tower in operational condition.
Supply only spares for carryi34 TR DX type central AC plant Cooling tower of 34 TR DX type central AC plant and Cooling tower of 48 TR Water cooled chiller type central AC plant under relevant items:-
PVC FILLS 600X300X150 MM
CT fan assembly cast aluminium alloy 1200 mm
CT fan electric motor of capacity 2 HP/1.5 KW , inimum 910 RPM , insulation class F, IP55. Make: Oswal/ Kirloskar/CG/ABB
PVC elimintaor 600x600 mm size
FRP Louvers 5 feet long
FRP motor cover
PVC branch pipes 63 mm dia & 30 inches long
Splash Cups
M/L for repairing and servicing the reciprocating sem-hermetic compressor of 30 TR capacity of Make: Carrier Model 06E729910 of Carrier Air cooled package Ac plant Model : 30 GTC 30, by opening the head covers, side inspection covers, crank case, valves assembly, both suction and discharge, check the wear and tear of the parts, cleaning the complete compressor with CTC/Petrol, flushing the capacity control loading and unloading circuit, reassembly the compressor by renewal of the defective spare parts and leak testing, charging R-22 gas and testing and commissioning the compressor including replacement of gasket set, ‘O’ ring set, suction and discharge ring plates, piston rings and star washers. Note: Motor rewinding of compressor, Gas, Spares & compressor oil will be measured and paid separately under relevant schedule items.
Supply only the folllowing spares of reciprocating sem-hermetic compressor of 30 TR capacity of Air cooled scroll chiller package AC plant of capacity of Make: Carrier Model : 30 GTC 30 for repair/ replacement under item no.04above
(a) Piston complete with pin and ring set, gudgeon pin and circlip lock complete
(b) small end bearing of connecting rod complete
(c) big end bearing and connected rod complete
(d) main bearing (front and rear) complete
(e) suction and discharge reeds including tension springs complete
(f) oil pump
(g) 'O' ring set
(h) compressor gasket set
(i) cylinder liner with suction valve
(j) crank shaft of compressor
Material and labour for dismantling and rewinding of Compressor motor of central AC Plant for OT of capacity 30 HP,cutting and removing existing burnt/short circuited winding wire complete, cleaning of core grooves and surfaces, re-winding the motor with superior quality enamelled copper winding wire duly ISI marked of suitable gauge for same Nos of coils and turns including insulation material such as sleeves, lathorised fiber glass, cotton/PVC tape, varnish etc reassembling the motor and refixing the same with chiller unit of capacity 30TR and testing the same for the minimum period of 08 Hours complete all as specified and directed
Supply only the folllowing spares of DX type AC plant of capacity 34 TR (2x17 TR running & 1x17 TR Stand by) of Make: Voltas for repair/ replacement under item no.02
HP Switch/sensor
LP Swicth/sensor
Expansion valve of capacity 8.75 TR scroll compressor
Drier suitable for 8.75 TR scroll compressor
Controller with all connected wiring/ safety protections suitable for 8.75 TR scroll compressor unit
Scroll compressor of capacity 8.75 TR Make: Voltas Model No. SZ110S4C Make: Danfoss/Copeland/Voltas.
Supply and charging refrigerant gas R 407A/ R 410A for gas charging for DX type AC plant complet onene time for topping up or making full qty as per the pressure requirement of plant and testing for any leakage and rectifying the same as directed by Engineer in Charge and testing on full load condition for 8 Hrs period. Make: Mafron/ Freon/ Floron
Supply and charging refrigerant R-22 complete one time for topping up or making full qty as per the pressure requirement of plant and testing for any leakage and rectifying the same as directed by Engineer in Charge and testing on full load condition for 8 Hrs period. Make: Mafron/ Freon/ Floron
Supply only compressor oil for carrying out repairs under relevant items above Make: SERVO/ Sheetal N-68 /Sandon/Equivalent
Supply & Fixing of 100mm Dial Suction Pressure gauge suitable for R-22 Gas service with suitable adapter. Make: H-Guru/ Fiebig/Warfee
Supply & Fixing of 100mm Dial Discharge Pressure gauge suitable for R-22 Gas service with suitable adapter. Make: H-Guru/ Fiebig/Warfee
Supply & Fixing of 100mm Dial Oil Pressure gauge with suitable adapter.Make: H-Guru/ Fiebig/Warfee
Supply & Fixing of capacity control solenoid valve of 3 way connection and suitable to operate in 230V 50Hz AC for SMC series ACCEL make compressor
M&L for servicing the Air handling units 6000 CFM capacity (DX type central AC plant ), with and including dismantling units, sheet metal parts, blowing out the dust, chemical cleaning by spraying the organic based scale removing agent (Vaniklin) at the appropriate ratio till removal of complete dust & scale deposits in the fin area of evaporator coil, flushing through for proper air flow across the coil, cleaning of expansion valve; greasing of blower motor, checking of electrical connection, cleaning of air filters,greasing of blower motor,replacement of un serviceable bearings, water drain lines, renewal of rusted sheet metal screws, applying synthetic enamel paint over a coat of primer on the rusted portion and testing & commissioning the unit all as specified and as directed by Engineer-in-Charge.Note : M/L for new DX coil & pre-filters will be measured and paid separately.
S&F in repair double skin ceiling suspended TFA unit of capacity 6000 CFM capacity (for DX type central AC plant ), along with pre-filter section of 90% down to 10 microns, 3 phase motor with forward curved blower , angle iron supports , DOL starter panel of 5HP capacity, copper cable 4 Sqmm 4 core with conduit pipe, Manual GI duct dampers, canvas connection etc complete including applying synthetic enamel paint over a coat of primer on the rusted portion and testing & commissioning the unit all as specified and as directed by Engineer-in-Charge.Note : M/L for new DX coil will be measured and paid separately.
Supply ,installation, testing & commissioning of DX coil with two (02) circuits suitable for 6000 CFM AHU of DX type central AC plant of capcity 3x17 TR ( with two Nos compressor of 8.75 TR each) of Make: Voltas including dismantling old one and necessary addiitons/ alternations complete all as directed and specified.
M&L for servicing the Air handling units 6000 CFM capacity (Air cooled reciprocating liquid chiller AC plant ), with and including dismantling units, sheet metal parts, blowing out the dust, chemical cleaning by spraying the organic based scale removing agent (Vaniklin) at the appropriate ratio till removal of complete dust & scale deposits in the fin area of evaporator coil, flushing through for proper air flow across the coil, cleaning of expansion valve; greasing of blower motor, checking of electrical connection, cleaning of air filters,greasing of blower motor,replacement of un serviceable bearings, water drain lines, renewal of rusted sheet metal screws, applying synthetic enamel paint over a coat of primer on the rusted portion and testing & commissioning the unit all as specified and as directed by Engineer-in-Charge. Note : The quoated rate inclusive of replacement of PVC filters of capacity upto 10 micron complete all as specified and directed.
M&L for servicing the Air handling units 7500 CFM capacity (Air cooled reciprocating liquid chiller AC plant ), with and including dismantling units, sheet metal parts, blowing out the dust, chemical cleaning by spraying the organic based scale removing agent (Vaniklin) at the appropriate ratio till removal of complete dust & scale deposits in the fin area of evaporator coil, flushing through for proper air flow across the coil, cleaning of expansion valve; greasing of blower motor, checking of electrical connection, cleaning of air filters,greasing of blower motor,replacement of un serviceable bearings, water drain lines, renewal of rusted sheet metal screws, applying synthetic enamel paint over a coat of primer on the rusted portion and testing & commissioning the unit all as specified and as directed by Engineer-in-Charge. Note : The quoated rate inclusive of replacement of PVC filters of capacity upto 10 micron complete all as specified and directed.
M&L for servicing the Air handling units approx 7000 CFM capacity (2ASD central AC plant ), with and including dismantling units, sheet metal parts, blowing out the dust, chemical cleaning by spraying the organic based scale removing agent (Vaniklin) at the appropriate ratio till removal of complete dust & scale deposits in the fin area of evaporator coil, flushing through for proper air flow across the coil, cleaning of expansion valve; greasing of blower motor, checking of electrical connection, cleaning of air filters,greasing of blower motor,replacement of un serviceable bearings, water drain lines, renewal of rusted sheet metal screws, applying synthetic enamel paint over a coat of primer on the rusted portion and testing & commissioning the unit all as specified and as directed by Engineer-in-Charge. Note : The quoated rate inclusive of replacement of PVC filters of capacity upto 10 micron complete all as specified and directed.
Material and labour for strip Opening of existing unsv chiller unit for the following repair/replacement at AC Plants–
Material and labour for servicing/cleaning of chiller unit including aluminium fins with dilute chemical solution under high pressure of flow and with the help of nylon brush 3-4 times followed by the cleaning and washing with water (water point shall be given at AC Plant) so that chemical solution is completely cleaned out from the system. Replacement of nut, bolt and washers of suitable size whichever are existing UNSV, assembling the dismantled parts carefully, sealing all joints with ruptum brazing as required and complete all as specified and directed by Engineer-In-Charge.
Replacement of existing oil seal assembly and key of the shaft and testing for any leakage of coolant and testing the same and rectifying the defects noticed as per directed.
Dismantling both the condensing fans for 30TR capacity with proper tools and testing the same and rectifying the defects noticed and reassembling the same by supplying replacement of existing UNSV key, bearings,Shaft and fan blades fixing arrangements of suitable size as required and proper greasing of the same wherever necessary. Make:Carrier/Equivalent
Descaling of chiller water pipe line of 24/30 TR chiller plant by draining chilled water from equipments and pipes. Recirculating water inside the pipes with descaling liquid solution(Carbon Tetra Chloride Solution) and flushing out 3-4 times. Recirculating fresh water inside the pipes and flushing out five to six times so that descaling liquid is completely cleaned out along with Scales from the pipe line complete all as specified and directed.
M&L for dismantling the defective induction motor of any make, any duty or any class of insulation from the bed, duly coupled with pump/ compressor, transporting to workshop, removing burnt out winding from stator/ rotor, rewinding with suitable gauge of super enamelled copper wire of approved make and replacing drive end and non drive end bearings, insulation materials, varnishing, heating, re-assembling, testing and commissioning of the following capacities including replacing base frame bolts & nuts complete all as directed:
Notes: (i) Motor removed for re-winding shall be overhauled completely and quoted rate is inclusive for the same.
a) 3 HP up to 5 HP
M&L for taking down mono block type water pumps of 03 to 05 HP by disconnecting the power supply cables, water lines both inlet & outlet, providing dummy flanges with gasket and overhauling pump sets, renewal of the worn out gland packages/ seal pack, bearings, bushes and gasket packing, greasing cleaning & removal of the scale in impeller, assembling the pump sets fixing in position, inter connecting the suction & discharges, connecting up the cable, testing and commission the following capacity pumps. All as specified as directed by Engineer-in-Charge.
M&L for taking down the defective fan motor of flange mounted extended type shaft upto 3 HP, 3 phase, 415 volts, 50 Hz, along with fan assembly, and dismantling the motor complete cleaning with CTC, including rewinding the motor with appropriate gauge copper wire, necessary paper, tape, terminal etc., insulation shall be of class ‘F’ and degree of protection shall be IP-55, the work includes renewal of all corroded bolts & nuts, terminal block, and assembling, fixing in position, fixing of fan blade, and alignment of the fan blade for the suitable air throw of the cooling tower, testing & commissioning the cooling tower motor. all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repairs 3 pole power contactor of 32 to 40 A rated operational current carrying capacity(AC3 duty), with coil operating voltage 230 V/ 415 V AC 50 HZ of Make: Schneider / L&T,C&S ,GE ,BCH.
Supply and fixing in repairs overload relay with operating range 32 to 40 A of f Make: Schneider/L&T/C&S/GE/BCH.
Supply , assembly and erection of GI sheet with TDF flange rectangular/square duct made out of 'L' shaped hollow profile, duly factory boxed, incl all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc complete of size 24 Gauge of any heights including dismantling old defective one.
Removing the wornout duct insulation carefully , cleaning/preparation of surfaces and M&L for duct insulation (40 MM THICK) with resin bonded fibre glass wool roll of density 24 kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation as specified and including the following:-a) M&L for cleaning the duct surface (to be insulated ) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) M&L for applying rubber based adhesive CPRX compound. (c) M&L for sealing of all longitudinal joints and circular overlaps with and including Aluminium foil tape 50 mm wide, to make the insulation leakproof. (d) M & L for securing the insulation with and including mechanically fastened nylon/ steel straps of size 12 mm/50 mm at maximum intervals of 1.2 mtr.
Supply and lay M S Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of sizes as shown including dismantling old unserviceable pipes.
M & L for Insulation of M S Pipe with PUF slab 30 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet complete of 50 mm size including dismanlting old worn out cladding.
M & L for Insulation of M S Pipe with PUF slab 40 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet complete of sizes as shownincluding dismanlting old worn out cladding.
S&F in repair butterfly valves of following sizes as per IS 13095 , PN 1.0 rated including connected accessories such as rubber gasket, nut bolts etc complete all as directed. Make: Leader/Zoloto/L&T
M & L for de-scaling the condenser of capacity 8.75 TR ( of DX AC plant) by using Sulphuric acid agent with continuous circulation pump and finally neutralizing with fresh water by opening both end covers of shell and tube condensers, cleaning with nylon brushes, re-fixing the end covers with new rubber gaskets, greasing the nuts/ bolts and testing and commissioning all as directed by Engineer-in-Charge.
M & L for de-scaling the condenser of capacity 24 TR ( of Chilled water type central AC plant) by using Sulphuric acid agent with continuous circulation pump and finally neutralizing with fresh water by opening both end covers of shell and tube condensers, cleaning with nylon brushes, re-fixing the end covers with new rubber gaskets, greasing the nuts/ bolts and testing and commissioning all as directed by Engineer-in-Charge.
Material & Labour for taking down the defective split/Window unit of the following capacity, shifting to work shop, taking out the defective unserviceable hermetically sealed compressor from the unit, replacing the compressor with new compressor of the same capacity, fixing to the unit inter connecting the refrigerating lines, flushing out the cooling coil & condenser, removal the coil & carbon thoroughly, cleaning with CTC, leak testing, pressure testing with Nitrogen gas, dehyderating, Vaccumissing, charging of Refrigerant gas, testing at work shop. Shifting to the location reinstalling the same in its Original position connecting up all etestion electrical, connection and Testing & Commissioning. All as specified as directed by Engineer-in-Charge.
1.5 TR Capacity
2 TR Capacity
Note : Rate quoted is deemed to be inclusive of cutting, welding, brazing, sealing the refrigerant tubing, replacement of strainer, CTC, Nitrogen gas, Refrigerant gas, required to and from Transportion and Handling. M/L for spares will be measured and paid separately Make of AC unit shall be, carrier / Voltas / LG / Blue Star, Videocon, Usha
Material and Labour for complete repair to out door unit of Split type AC Unit, including taking down all the components tinkering the rusted portion, renewal of complete rusted sheet metal parts, with the same thickness M.S. sheet as per the existing size & shape including cutting, bending welding, drilling etc., including renewal of all nut & bolts sheet metal screws, mounting legs, rubber bushes, and cleaning & prepare the surface thoroughly, applying two coat of synthetic enamel paint over a coat of red oxide primer fixing of all components, brazing the refrigeration piping and shifting to its original position and connecting up all electrical connections and testing all as specified as directed by Engineer-in-Charge.
1.5 TR Capacity
2 TR Capacity
Note : Rate quoted is deemed to be inclusive of cutting, welding, brazing, sealing the refrigerant tubing, replacement of strainer, CTC, Nitrogen gas, Refrigerant gas, required to and from Transportion and Handling. M/L for spares will be measured and paid separately Make of AC unit shall be, carrier / Voltas / LG / Blue Star/ Videocon/ Usha
Material and Labour for taking down the damage condenser fan blade of 1.5TR split/Window type AC’s of any make and supply & fixing suitable new fan blade and testing & commissioning the unit.
All as per Item above But 2 TR Split AC
Material and Labour for taking down the damaged blower unit of any make split/Window AC and supply and fixing of new blower unit of suitable type and testing & commissioning the unit.
Material and Labour for complete scraping out the crusting painting of the complete body of out door unit metallic surface, cleaning the surface thoroughly, apply putty / metal paste, prepare the surface, apply 2 coat of synthetic enamel paint over a coat of red oxide primer for 1.5 / 2TR capacity split type AC’s.
Material and Labour for cleaning flushing the refrigeration system thoroughly with CTC, and Nitrogen gas, leak testing and locating the leaks, rectifying the leaks, by brazing the joints, replacing the damaged copper pipes, silver rod/ copper. Pressure testing, dehydrating, vaccumissing, gas charging testing & commissioning the system the work includes required strainer, N2 gas, Refrigeration gas and transportions Handling the unit. All as specified as directed by Engineer-in-Charge.
1.5 TR Capacity
2 TR Capacity
Material and Labour for taking down the unserviceable temperature sensor probes and supply & fixing new sensor probe suitable for any type, make split/Window type AC’s and testing & commissioning.
Material and Labour for taking down the defective unserviceable printed circuit Board and S/F of new printed circuit board for any make split/window type AC unit.
Material and Labour for taking down the defective unserviceable sealed fan motor & S&F new fan motor of the same capacity & size to suit the split/window AC unit of any make and capacity of 1.5 / 2 TR all as per existing at site
Material and Labour for taking down the damaged air filter set and S/F of new air filter set for split/window type AC’s of 1.5 / 2TR capacity.
Material and Labour for taking down the defective unserviceable starting/running capacitors 80/100 MFD 230V / 50Hz and supply and Fixing the new starting capacitor of the same capacity to split / window type AC’s and testing.
Material and Labour for taking down the defective unserviceable starting relay and supply and fixing new rely suitable for 1.5/2TR Window / Split type AC’s and Testing.
Material and Labour for taking down the defective unserviceable Thermostatic switch and S/F new thermostatic suitable for window type AC’s and Testing.
Material and Labour for taking down the damaged drain pipe and S/F of new insulated drain pipe suitable for split type AC’s.
Material and Labour for taking down the defective capillary tube set and supply & Fixing new suitable capillary set for split type AC’s.
Material and Labour for taking down the rusted out door unit stand and supply & fixing the stand with required anchor fastner and nut & bolts and rubber bushes for 1.5 / 2 TR Split unit.
Material and Labour for taking down the burned out door unit fan motor and rewinding, overhauling renewal of worn out shaft & bushes, and fixing to the unit, of 1.5 / 2 TR Split units.
Material and Labour for taking down the defective remote control unit and S/F of new remote control unit for split/window type AC of 1.5 / 2 TR of any make and testing.
Material and Labour for taking down the defective definite purpose magnetic contactor of the split/window AC’s of any make, and supply & fixing of new contactor of 240 VAC. 30 Amps 50 Hz, and coil volt of 208/240V 50/60Hz and Testing.
Material and Labour for taking down the defective unserviceable sealed motor of indoor unit of any make split unit of 1.5/2 TR capacity and S/F new fan motor suitable for Split type AC’s.
Material and Labour for taking down the defective starting capacitor of split / window type AC’s and supply & fixing the new starting capacitor of 80/100 MFD 230V, 275SV-50Hz and Testing for 1.5/2TR AC Unit.
Material and Labour for taking down the burned wiring kit and supply & fixing and testing of new wiring kit suitable for 1.5/2TR split and window type Ac unit.
Material and Labour for taking down by disconnecting water connections and shifting elective water cooler to work shop, taking down the defective sealed compressor and replacing with new compressor, the work includes flushing the complete system condenser, cooling coil with Nitrogen, removal all carbon, oil & dirt, brazing & inter connecting the refrigeration lines, de-hydrating, purging with refrigerant, vaccumissing and charging of R22/R134A/R407/R410 Refrigerant and testing & commissioning and shifting to original location and connecting up the electrical & water connection for the following capacity water coolers complete all as specified as directed by Engineer-in-Charge.
40/60/80 Ltrs. capacity water cooler
120/150 Ltrs. capacity water cooler
Material and Labour for complete tinkering the corroded sheet metal parts, side panel, door, with existing gauge M.S. Sheet and renewal of the bottom base plate, mounting lets, fan motor base plate, and condenser should cover etc., with existing size gauge G.I. sheet, with required Angle Iron, Nut & Bolts all as per the existing size and shape including cutting, bending, welding and completing fixing all other components, complete scraping with old paint, prepare the surface, painting 2 coat of enamel paint over a coat of primer and complete cleaning the water tank and shifting to the location and testing any capacity of water coolers. All as specified as directed by Engineer-in-Charge.
Material and Labour for charging the water cooler of the following capacitor including taking down, transporting to workshop flushing out the cooling coil, condenser, brazing the refrigerant lines, replacing of liquid line copper strainer, leak testing, purging with refrigerant, vaccumissing and charging of R22/R 134a gas, testing & commissioning and shifting to the location and connecting up the electrical & water connection. All as specified as directed by Engineer-in-Charge.
a) 40/60/80 Ltrs. capacity water cooler
b)120/150 Ltrs. capacity water cooler
Material and Labour for painting the water cooler including scraping out the old paint prepare the surface, painting 2 coat of enamel paint over a coat of primer, the work including necessary putty, metal paste etc., and disconnecting from the position and refixing after painting for any capacity of the water coolers.
Material and Labour for to the water cooler tank and cooling coil by dismantling the water cooler and carried out the lead soldering to cooling coil to the tank outer surface where ever the detached portion and rectify the leaks portion and re-assembly the water cooler of any capacity.
Material and Labour for taking down the damaged thermal insulation of the water cooler, and renew the thermal insulation as per the existing thickness and assembling the body with necessary sheet metal screws etc., for any capacity water coolers.
Material and Labour for taking down the defective starting relay and S/F of new starting relay for any capacity water cooler.
Material and Labour for taking down the defective overload relay and S/F of new over load relay suitable for any capacity water cooler.
Material and Labour for taking down the defective Running capacitor and Supply & Fixing new running capacitor 20/10 MFD, 440 VAC 50/60 Hz suitable water cooler.
Material and Labour for taking down the defective starting capacitor and Supply & Fixing new starting capacitor 60/80 MFD, 230V, 270SU-50 Hz for water cooler upto 120 Ltrs. Capacity.
Material and Labour for taking down the defective Running capacitor and Supply & Fixing new running capacitor of 25/36 MFD, 440 VAC, 50/60 Hz suitable for 150 Ltrs. Capacity water cooler.
Material and Labour for taking down the defective thermostatic switch and Supply and Fixing of new thermostatic switch for water coolers.
Supply and Fixing of Left/Punch cook for water cooler of any capacity.
Supply and Fixing float valve for water cooler of any capacity
Material and Labour for taking down the damaged drain connections and drain pipe and S/F of new drain connection & pipe with necessary clamps, Nipple, coupling etc., for any capacity water cooler.
Material and Labour for taking down the defective unserviceable sealed fan motor and S/F new fan motor with suitable capacitor for water cooler upto 40/80, 60/120 ltrs. Capacity.
Material and Labour for taking down the damaged condenser fan blade and supply and fixing of new fan blade suitable for 40/60/80 water coolers.
Material and Labour for taking down the corroded air cooler condenser and supply and fixing of new air cooled condenser with necessary brackets and fixing arrangements including welding brazing etc., for water cooling 40/60/80 Ltrs. Capacity.
Material and Labour for taking down the complete corroded sheet metal body of our door unit of split unit and supply and fixing of new out door unit suitable 1.5 TR split unit the work includes dismantling the components and reassembly and fixing to the existing location and testing for any make of split unit.
All per item No 127 above But 2 TR Split AC
Material and Labour for taking down the corroded air cooled condenser and supply and fixing of new air cooled condenser suitable for 1.5 TR Split Ac
All per item No 129 above But 2 TR Split AC
M & L sub-main wiring with 4.0 Sq.mm (nominal area) PVC unsheathed multi strandard copper conductor PVC insulated 1100 volt grade single core cable drawn through and including rigid PVC conduit medium grade minimum 20mm size and its accessories complete along with 4.0 Sqmm cable but in green colour as continuous earthing wire and connecting to common earth dolly completely concealed ,surface,in walls/ceiling/roofs all as directed and specified including dismantling old one Note : Three runs of PVC copper cable and one run of PVC conduit will be measured as one Rm.
Material and Labour for complete carryout the servicing to Split/Window type AC’s including taking down from the position, dismantling the sheet metal parts, blowing out the dust, carryout the chemical cleaning to chocked cooling coil & condenser coil, by spray the dilated chemical cleaning agent, till remove complete chocking, flushing across the coils, cleaning all the sheet metal parts, filter, grill and fixing all the dismantled parts with sheet metal screws, lubricating the fan motor bush / bearing, checking all the electrical connections, renew any burned legs / clip and fixing back to position and testing.(Note: Gas Charging if required will be measured and paid seperately).
Supply and charging refrigerant R-22 complete one time for topping up or making full qty including plugging the leakage complete and as directed.
Supply and charging the refrigerator gas R-134A including replacement of Compressor oil complete all as specified and as directed.
Supply and charging compressor oil suitable for AC's, water cooler ,Refrigerator and deep freezer complete including testing etc, complete all as specified and as directed.
M&L in replacement of existing motor fan blade for walking cooler of capacity 5 TR including testing complete all as specified and directed.(As per sample)
M&L in replacement of existing UNSV MNX-9 contactors. Make : L&T / Havells
M&L in replacement of existing UNSV MNX-18 contactors. Make : L&T / Havells
S&F in replacement of existing UNSV over load relay (3 Amp to 16 Amp) for walk-in-cooler. Make : L&T / Havells
S&F in replacement of existing UNSV plug Top 3 pin 5 Amp Make Plaza/Anchor/GM
S&F in replacement of existing UNSV plug Top 3 pin 15 Amp Make Plaza/Anchor/GM
S&F in replacement of existing UNSV condenser fan blade metallic suitable for walk-in-cooler 5 TR Cap, (As per sample)
Replacement of unsv Compressor complete suitable for Walk in cooler of capacity 5TR with all fastening arrangements including required amount of gas charging with proper suction and discharge pressures. Make: Copeland/Danfoss or equivalent make approved by GE.
M&L for overhauling/rewinding of fan motor of walking cooler with super enamed copper conductor incl varnish etc complete all as specified and as directed.
Removing the old paint of the body of refrigerator of any capacity and making the body dent proof and preparing the surface and Painting the refrigerator with 2 coats of synthetic enameled paint of superior quality to match with existing paint with spray painting complete all as specified and directed.
S&F in replacement of existing UNSV sealed Compressor unit for Refrigerator of capacity 165 to 195 Ltrs including Gas charging. Make: Copeland/Danfoss/Voltas/Blue star/LG.
S&F in replacement of existing UNSV sealed Compressor unit for Refrigerator of capacity 285 to 320 Ltrs including Gas charging. Make: Copeland/Danfoss/Voltas/Blue star/LG.
S&F in replacement of existing UNSV sealed Compressor unit for Deep freezer of capacity 320 Ltrs including Gas charging. Make: Copeland/Danfoss/Voltas/Blue star/LG.
S&F in replacement of existing UNSV sealed Compressor unit for Deep freezer of capacity 400 Ltrs including Gas charging. Make: Copeland/Danfoss/Voltas/Blue star/LG.
S&F in replacement of existing UNSV cooling Thermostat switch suitable for refrigerator/deep freezer of any capacity.
M & L for replacement of old unsv fan motor with fan motor suitable for deep freezer of any capacity including all accessories complete all as specified and as directed.
M & L for old unsv wiring for desert cooler including all accessories all complete diected by Engr-in-Charge.
M&L for Replacement of existing UNSV blower motor & fixing the new blower motor suitable for desert cooler single way shaft 240 Volts 50 c/s complete all as specified.
M&L for Replacement of existing UNSV circulation pump suitable for desert cooler 240 volts 50 c/s single phase Complete all as specified and directed.
S&F in replacement of existing UNSV Khaskhas pad honey bee type (set of 3) for Desert Cooler of any capacity ( Set of three).
Removing the old paint from the body of desert cooler making the body dust proof and preparing the surface and painting the desert cooler with 2 coats of synthetic enamel paint of superior quality over a coat of Red Oxide primer all as specified.
Removing the old rusted base tub of desert cooler and fabrication of base tray and top cover made of PGI sheet of 22 gauge and fixing in position using necessary nuts, bolts and washers all as specified and directed.
S&F in replacement of existing UNSV galvanized iron top cover 0f 22 gauge per and providing new one of existing size, gauge and shape ,nuts and bolts suitable for 3000/4000 cfm capacity Desert Cooler complete all as specified and directed by Engr-in-Charge.
S&F in replacement of existing UNSV galvanized iron side pillar of 22gauge as per and providing new one of existing size and shape ,nuts and bolts suitable for 3000/4000 cfm capacity Desert Cooler complete all as specified and directed by Engr-in-Charge
S&F in replacement of existing UNSV galvanized iron side shutter of 22 gauge as per and providing new one of existing size and shape ,nuts and bolts suitable for 3000/4000 cfm capacity Desert Cooler complete all as specified and directed by Engr-in-Charge.
Note for Srl item No.1 to 161 : The work involves of various areas of AGE E/M (S) Pathankot. The Contractor shall depute manpower on daily basis separately for each area for attending and rectifying the jobs in time. If any breakdowns/complaints/defects simultaneously occured in any areas shall be attended simultaneously by deputing additional manpower/T&P for rectification of defects.The rate quoted deemed to be included for the same. Recovery for non attending of any type rectification/complaint/breakdowns shall be made at the rate of Rs 2500 per day irrespective nature of complaint/defect.
Sch of Credit = 98410.00
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
M/S J N TRADERS
M/S MS ENTERPRISES
INDERJIT SINGH
satpal and brothers
M/S BALWINDER SINGH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .