Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance B 46 INDUSTRIAL AREA SECTOR 59 NOIDA UP 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance 143 MALL ROAD MALL APPTT NEW DELHI DELHI 110009 | NORTH WEST DELHI | DELHI | 110009 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance 1014 105 KINGSTON TOWER OPPOSITE OLD VIVA COLLEGE ABOVE DOMINOS PALGHAR MAHARASHTRA 401303 | PALGHAR | PALGHAR | MAHARASHTRA | 401303 | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Not Admitted-Fee/PreQual/Technical/Finance 31 2 ADAKAMARANAHALLI MAKALI POST VILLAGE DASANAPURA HOBLI BANGALORE URBAN BANGALORE RURAL KARNATAKA 562123 | BENGALURU RURAL | KARNATAKA | 562123 | Not Admitted-Fee/PreQual/Technical/Finance Fee not submitted |
| 5 | Not Admitted-Fee/PreQual/Technical/Finance 14 1ST FLOOR TILAK NAGAR INDUSTRIAL AREA BEHIND SUBHASH NAGAR METRO STATION NEW DELHI 110018 | NEW DELHI | NEW DELHI | DELHI | 110018 | Not Admitted-Fee/PreQual/Technical/Finance Fee not submitted |
Tender Value
₹2.2 Cr
Closing Date
27 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer PHE-I
135 main building JDA Indira Gandhi Circle Jaipur
Supply installation and maintenance of Online Continuous Effluent Monitoring System OCEMS i.e. pH BOD COD TSS and Flow along with data transfer to CPCB and RSPCB server for running 8 STPs under PHE I/II Zone and 1 no in Housing I/II zone Phase-I for
2021_JDAJP_249492_1
EE PHE-I_06_2021-22
Open Tender
Civil Works
Item Rate
180 days
Various locations
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Secretary, JDA
Yes
28 Dec 2021
6 Dec 2021
28 Dec 2021
6 Dec 2021
27 Dec 2021
6 Dec 2021
120 days
Amount
For Outlet parameters online monitering including data transfer charges to CPCB & RSPCB with 1 year DLP/warranty
MIQ/TC 2020 3G-C6: Local Display Unit. Multi-parameter measuring converter, for connecting to 20 IQ sensors. Scope of supply: MIQ/TC 2020 3G Terminal/Controller, MIQ/C6 with 6 analog outputs (0/4-20 mA), MIQ/PS wide-range power
CarboVis®705 IQ TS: (BOD, COD, TS S PROBE) Optical COD, BOD, TSS, probe (60 mm) with spectral processing of the UV- VIS range, for measurement in the inlet/effluent/ BNR part of municipal wastewater treatment plants with integrated ultrasonic cleaning. Supplied with multifunctional slide and Shock-Absorption-Rings. Measuring Range: BOD: (0-500 mg/l) COD: (0-800 mg/l) TSS: (0-900 mg/l)
SensoLyt® 700 IQ/SET: (Ph Probe.) Robust digital pH/O RP sensor (SensoLyt® 700 IQ) including pHelectrode (SensoLyt®SEA) and 7 m (23 ft) sensor adapter cable (SA CIQ-7,0) (pH Sensor with 7-meter Integratedcable) Temperature is integrated by default Measuring Range: PH: 0-14
SACIQ-7,0: Sensor adapter cable for all IQ sensors, with IP 68 waterproof connection to the IQ Sensor Net system. Cable length 7 meters
Wireless Modem with GSM Facility
Rittal Panel for controller IP 65 Grade
Flowmeter Electromagnetic Size: 6” Pipeline
UPS + Power Cables
Fabrication Material + Labour + Others Expensive
Installation Charges
Description of Work / Item(s)
Amount
Annual Maintenance Contract after warranty of 1st year
2nd Year AMC AMC for Water Quality Monitor (BOD, COD, TSS, PH & Flow meter) for outlet 1- Four service visit in year which will be scheduled 2- Calibration two times in a year 3- Data transfer to CPCB & SPCB 4- Consumable.
3rd Year AMC AMC for Water Quality Monitor (BOD, COD, TSS, PH & Flow meter) for outlet 1- Four service visit in year which will be scheduled 2- Calibration two times in a year 3- Data transfer to CPCB & SPCB 4- Consumables
4th Year AMC AMC for Water Quality Monitor (BOD, COD, TSS, PH & Flow meter) for outlet 1- Four service visit in year which will be scheduled 2- Calibration two times in a year 3- Data transfer to CPCB & SPCB 4- Consumables
5th Year AMC AMC for Water Quality Monitor (BOD, COD, TSS, PH & Flow meter) for outlet 1- Four service visit in year which will be scheduled 2- Calibration two times in a year 3- Data transfer to CPCB & SPCB 4- Consumables
Anodyne Water Engineering Co Pvt Ltd
AAXIS NANO TECHNOLOGIES PVT LTD.
Anodyne Water Engineering Co Pvt Ltd
AAXIS NANO TECHNOLOGIES PVT LTD.
stage.html
html • 0.03 MB
finance_445047.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .