Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Ref. No.
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LQualified 18H 37 D 1K GTB NAGAR KARAMAT KI CHAUKI MARG KARELI ALLAHABAD UTTAR PRADESH 211016 | PRAYAGRAJ | UTTAR PRADESH | 211016 | L1 | Qualified MII | |
| 2 | L2₹21.8 L+₹90,650 (4.35%)Qualified FLAT 7 SRADHANJALI APARTMENT 393 3F 6 PRINCE ANWAR SHAH ROAD PODDAR NAGAR KOLKATA WEST BENGAL 700068 | KOLKATA | WEST BENGAL | 700068 | L2 | Qualified MII | |
| 3 | Disqualified 136 INDRA COLONY JHOTWARA ROAD BANI PARK JAIPUR RAJASTHAN 302016 | JAIPUR | RAJASTHAN | 302016 | - | Disqualified MII |
Tender Value
₹21.1 L
EMD Value
₹42,134
Closing Date
5 Aug 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SITC OF 10 KVA ONLINE UPS SYSTEM WITH 05 YEARS
3612435
GEM/2022/B/2372803
UPS System,Battery Bank,CABLING SYSTEM 1,CABLING SYSTEM 2,Supply and Installation of Battery open c
Unknown (Unspecified Location)
Total value wise evaluation
BOQ
8 documents required · 8 mandatory
3 yrs
₹7 L
₹84 L
50%
₹42,134
5 Aug 2022
22 Jul 2022
5 Aug 2022
75 days from bid end date (until 19 Oct 2022)
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | UPS System | Design, manufacture, assembly, supply, installation, testing, delivery and commissioning of 10 KVA UPS of Continuous rating, inbuilt SNMP for online monitoring, double conversion mode 3 ph input and 1 ph output UPS system with IGBT rectifier. The UPS Cabinet shall consist of a Breaker and breaker cabinet, rectifier / charger, a three-phase inverter, static transfer switch, logic, synchronizing equipment, protective devices, display module shall show clear graphical / text based overview of alarms, status data and instructional help, Front/ Back cable entry provision, Parallel kit with necessary BMS compatibility (Hardware and software items for third party integration) with MODBUS protocol-RS 485 and accessories as required for proper operation. NOTE The model shall be suitable for parallel redundant and including total 05 years onsite warranty | 3 | Nos | [email protected] | 365 |
| 2 | Battery Bank | Supply, installation, testing and commissioning of Battery banks of requisite quantity and 12V, 42 AH rating suitable for 10kVA (Continuous rating) online UPS system with one suitably rated DC circuit breaker with all necessary interconnecting links/wiring for each of above UPS units with autonomy to 30 minutes at the end of Battery life span at rated load. Battery shall be of the sealed maintenance free Valve Regulated Lead Acid (VRLA) stationary type 12V blocks, Battery Rack and base frame shall be designed to cater a point load to be conformed by vendor. Minimum VAH required - 10080 | 60 | Set | [email protected] | 365 |
| 3 | CABLING SYSTEM 1 | Supply and Laying of 1100V grade multistrand, copper conductor, Uni Nyvin, unarmoured flexible cable of requisite size for interconnection between battery, battery breakers and the respective 10KVA UPS Units including incomer cable of raw power to UPS. . The cable shall conform to IS-694. | 210 | Mtr | [email protected] | 365 |
| 4 | CABLING SYSTEM 2 | Supply,Fixing and commissioning of cable termination with Single compression cable gland, Ring type copper lugs and necessary steel bolts for interconnection between battery, battery breakers and Cable ties for the respective 10 KVA UPS Units as required for site All Complete Job . | 3 | Lot | [email protected] | 365 |
| 5 | Supply and Installation of Battery open cabinet or Rack | Supply and installation of Open Battery Rack suitable for the Battery bank for 10 kVA UPS system as per point 2 item including UPS mounting | 3 | Set | [email protected] | 365 |
| 6 | Charges for ITC | Charges for Installation and Commissioning of the whole system including the charges for providing proper training to the Electrician of the Site/Hospital | 3 | Lot | [email protected] | 365 |
| 7 | WIRING SYSTEM for UPS 1 | Supplying and fixing TP sheet steel enclosure on surface/ recess with 40/ 63 A FP MCB complete with connections, testing and commissioning etc. as required. | 3 | Nos | [email protected] | 365 |
| 8 | WIRING SYSTEM for UPS 2 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - 12 way, Double door | 3 | Nos | [email protected] | 365 |
| 9 | WIRING SYSTEM for UPS 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | 570 | Mtr | [email protected] | 365 |
| 10 | WIRING SYSTEM for UPS 4 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 480 | Mtr | [email protected] | 365 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_3612435.pdf
GEM_BID
scope-of-work-for-ups-system-at-esi-hospital-uluber_2022-07-22-12-53-04_9e63effc5cc52ac37ca1286da103ea9e.pdf
BOQ
boq_item_sample_file_2022-07-22-12-53-04_be4898e276113be133d4d9eab53ae68b.csv
BOQ
gtc.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .