Assistant Engineer Behala Sub Division PWD
Assistant Engineer Behala Sub Division PWD_Old Building Ground Floor_32 Belvedere Road Alipore Kolkata_700027
Inspection Survey and testing of various components of construction materials of the collapsed Warehouse site at P2 Transport Depot Road Kolkata 700 088
2026_WBPWD_5019778_1
WBPWD/AEBSD/NIET-02/2026-27
Open Tender
Miscellaneous Works
Item Rate
20 days
ALIPORE
Please refer Tender documents.
5 documents required · 5 mandatory
₹5,000
Yes
21 Aug 2026
21 Aug 2026
3 Sept 2026
21 Aug 2026
1 Sept 2026
26 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Test to be conducted of the building materials used in the structure to ascertain the quality of materials in respect to post collapsed Warehouse site at P2 Transport Depot Road.
The scope of work includes:-
1) Visual inspection for surface damages and damaged classification and recording field observation with GIS tagged photographs. Visual inspection shall cover following parts of all areas of thecollapsed building.
A) Structural Steel Parts (Beams, Columns, and Joints)
B) Concrete Structures (Foundations and Slabs)
C) Roof and Truss System
D) Structural Member Dimensions
- Column and Base Plate Specifications
-Beam and Joist Profiles
- Slab and Roof Deck Parameters
E) Structural Steel Framing & Connections
F) Various component of constructed materials collected from the site suct as
i) Bolt and washer, ii) Reinforcement bars for RCC slab, iii) Structural member of mild steel section, concrete samples
2) Conducting Rebound Hammer test on the concrete portions of the structure as per IS 13311(Part 2) :1992, as per requirement at site.
3) Experimental data and analysis of Steel Structural Specimens
A) Microhardness Analysis
B) Raman Spectrum Analysis
C) SEM Analysis
4) Mechanical Tensile testing of Structural steel Specimens.
5) Compressive Strength Testing of Concrete Samples tested at laboratory.
6) Load-carrying capacity and mechanical properties of reinforcement bars used in the RCC members.
7) Submission of comprehensive report in six copies and soft copy which consist of finding from visual inspection, test data, results, conclusions and final recommendations.
[Note 1# Adequete numbers of specimens are to be collected from the site to ascertain the quality of the construction materials used in the collapsed structure]
[Note 2# All tests to be done from the any Recognized Institute of State Government or Central Government] | 1 | Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.29 MB
Tendernotice_2.pdf
PDF • 1.43 MB
BOQ_5092847.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].