Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.5 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹17.1 L+₹1.1 L (7.12%)Rejected-Finance MATHOSHREE PLOT NO 55 SR NO 787 A BEHIND ASHWANI HOSPITAL GOVIND NAGAR NASIK 422 009 | NASIK | NASHIK | MAHARASHTRA | 422009 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹17.5 L+₹1.6 L (9.76%)Rejected-Finance PLOT NO 106 MIDC SATPUR SATPUR MIDC AREA SATPUR NASHIK MAHARASHTRA 422007 UDYAM MH 23 0018515 | NASHIK | MAHARASHTRA | 422007 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹19.7 L+₹3.8 L (23.7%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹19.8 L+₹3.9 L (24.6%)Rejected-Finance CHATAI SHEEP WARD NO 07 NEW MARKET ROAD AHIWARA DURG CHHATTISGARH 490036 | DURG | CHHATTISGARH | 490036 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹39,900
Closing Date
6 Apr 2021, 6:00 pmClosed
CWE DEOLALI
HQ CWE DEOLALI, ONSLOW ROAD, DEOLALI (MH)
AS PER TENDER DOCUMENTS
2021_MES_431475_1
83571/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
NASIK
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE NASIK ROAD CAMP
₹39,900
Yes
2 Jun 2021
18 Mar 2021
8 Apr 2021
18 Mar 2021
6 Apr 2021
1 Apr 2021
19 Mar 2021 - 24 Mar 2021
Amount
Dismantling carefully the existing U/S LT/HT Overhead line ACSR conductor of any size from its position by necessary disconnecting of conductor and removing complete all as directed by Engr-in-Charge.
Supply and stringing ACSR conductor for over head line securing on pole complete including binding wire ,jointing sleeves aluminium tap and PG clamp etc of any size all as specified and as directed.
Stringing only old dismantled ACSR conductor for over head line securing on pole complete including binding wire , etc of any size all as specified and as directed.
S & F 1100 Volts grade 4 line composite phase separators, moulded & bolted type as per IS 1445 - 1997 make max well or Denson including taking down old u/s separator.
S & F 1100 Volts grade 5 line composite phase separators, moulded & bolted type as per IS 1445 - 1997 make max well or Denson including taking down old u/s separator
Dismantling of U/S insulator of any size and type complete from its position and removing all as directed by Engr-in-Charge.
Re-fixing of old LT pin insulator obtained from item No 6 above.
Re-fixing of old LT shakel insulator obtained from item No. 6 above
S & F pin type insulator 100mm height and 65mm dia for 1100 Volts grade, porcelain White, Brown or Green including one GI spindle, two GI washer, one GI nut all as specified and directed by Engr-in-charge.
S & F LT shackle type insulator 90mm dia 75mm height, including GI strip of Size 31 x 3 mm washers, 12mm dia, Insulators nuts, bolts suitable for 1100 volts grade.
Taking down old jumper connection of 4 pole structure from line/AB/DO & re-fixing complete with new conductor , including line tap, lugs, & PVC alkadin/pipe sleeve all as specified and directed by engr-in-Charge. ( ACSR conductor will be measured & paid separately )
Taking down old jumper connection of 2 pole structure from line/AB/DO & re-fixing complete with new conductor , including line tap, lugs, & PVC alkadin/pipe sleeve all as specified and directed by engr-in-Charge. ( ACSR conductor will be measure & paid separately )
Taking down old jumper connection of disc cut point from line and re-fixing complete with new conductor , including line tap, lugs, & PVC alkadin/pipe sleeve all as specified and directed by engr-in-Charge. ( ACSR conductor will be measure & paid separately )
Taking down of faulty LT underground cable of size upto 3.5 x 25 sqmm from trenches/pole/wall etc for detecting fault including repair and jointing at site including relaying at the same location complete : Note : Excavation/Earth work and cable jointing & jointing kit shall be measured and paid for separately under relevant item of schedule .
Taking down of faulty LT underground cable of size above 3.5 x 25 sqmm upto 150 sqmm from trenches/pole/wall etc for detecting fault including repair and jointing at site including relaying at the same location complete : Note : Excavation/Earth work and cable jointing & jointing kit shall be measured and paid for separately under relevant item of schedule .
Supply and joint cable jointing kit straight through joint epoxy type of size 10 sqmm 4 core to 16 sqmm 4 core all as specified and directed. Make : Denson, Raycom
Supply and joint cable jointing kit straight through joint epoxy type of size 25 sqmm 3.5 core to 50 sqmm 3.5 core all as specified and directed. Make : Denson, Raycom
Supply and joint cable jointing kit straight through joint epoxy type of size 70/95 sqmm 3.5 all as specified and directed. Make : Denson, Raycom
Supply and joint cable jointing kit straight through joint epoxy type of size 120 sqmm 3.5 to 150 sqmm 3.5 core all as specified and directed. Make : Denson, Raycom
Dismantling of U/S stay assembly carefully including stay wire necessary excavation and earth work in any type of soil, demolition of PCC of any type and removing from site all as directed.
Stay assembly complete with accessories and stay rod 16mm dia and 180 cm long, including ms galvanized stay plate 300 mm x300 mmx6mm and galvanized thimble complete all as specified and shown in electrical plate No 1 Note-(loop type insulator, stays clamps, excavation and earth work and concrete measured separately)
All as per Item No 21 but stay Rod 20 mm dia
Dismantling of U/S existing cross arms by means made from channels, angles, U/S CI clamps, nuts, bolts etc. from OH line and removing complete.
S & F Cross arms ,bracings,supports,clamps and back plate fabricated from structural steel sections including nuts ,bolts, in any shape or size as indicated or directed and inclusive of two coat of aluminium paint over a coat of red oxide .
S & F Switch air break gang operated triple pole mechanically operated mounted on insulator and steel frame out door type suitable for vertical installation single brake provided with locking arrangement, consisting of mild steel channel ,HT post type insulator ,copper alloy high pressure assembly ,operating rod of GI pipe medium grade confirming to IS-1818 of 1972 ,suitable for 11000 volt ,400 Amps incl dismantling of old one all as specified.Make:- Jaipuriya Bros
Dismantling of existing U/S HT/ LT pole of any size & type from its position carefully and removing from the site and necessary excavation and earth work in any soil/strata, demoltion of concrete, disconnection of conductor fom pole etc. complete all as directed.
Supply, install errect in trench vertical position steel tubular swaged poles complete with mils steel base plate 6mm thick of size 450mm x 450mm finial taper plug pole cap, bolts, nut and screwed, pole made out of ERW MS tubing confirming to IS 2713 Part II of 9 mtr long 410 SP-31 including drilling of holes of required size and nos for fixing of cross arms bracing support/ taking out of cables etc, and painting with one coat of red oxide primer and two coat of aluminium paint for exposed surface and two coat of black bituminious paint for the portion embeded in concerete complete all as specified and as directed by Engineer -in-charge.
Supply, install erect in trench vertical position steel tubular swaged poles complete with MS base plate of 6mm thick of size 450mm x 450mm finial taper plug pole cap, bolts, nut and screwed, pole made out of ERW MS tubing confirming to IS 2713 Part II of 11 mtr long 410 SP-55 including drilling of holes of required size and nos for fixing of cross arms bracing support/ taking out of cables etc, and painting with one coat of red oxide primer and two coat of aluminium paint for exposed surface and two coat of black bituminious paint for the portion embeded in concerete complete all as specified and as directed by Engineer -in-charge. (Note:- earthwork and PCC will be measured and paid separatly.
Taking down unservisable U/G cable,service wire from trenches, wall, floor etc upto 50 sqmm
Taking down unservisable U/G cable from trenches, wall, floor etc above 35 upto 95 sqmm
Supply , laying and testing XLPE insulated screened PVC bedded galvanised steel strip armoured electric power cable (Heavy duty ) with aluminium conductor 11000 volts grade lay in trenches , ducts , along pole, along transformer cross sectional area 3 core 95 sqmm complete all as specified and directed.
EXCAVATION BY TENCHLESS TECH - Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia. Suitable for 0.4 mpa working pressure.
M&L for cable jointing kit for 11 KV ( Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 3 core 95 sqmm all as specified and directed by Engr-in-Charge
M&L for cable jointing kit for 11 KV ( Earthed) grade cable for outdoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 3 core 95 sqmm all as specified and directed by Engr-in-Charge
M&L for cable jointing kit for 11 KV ( Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 3 core 95 sqmm all as specified and directed by Engr-in-Charge
S& F XLPE insulated armoured and pvc sheated heavy duty electric cable size of following sizes aluminium conductor 1100 volt grade as per IS 7098 (Part-1) 1988 with latest amendment laid in tranches passing through pipes /ducts including testing complete
(i) 2 core 10 sqmm
(ii) 4 core 16 sqmm
(iii) 3.5 core 50 sqmm
(iv) 3.5 core 95 sqmm
(v) 3.5 core 150 sqmm
Excavation in trenches for laying of cables ,poles and stay in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.50 mtr deep and getting out.
Material and labour for high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches of size 50 mm suitable for cable protection of size 50 sqmm complete all as specified and directed.
Material and labour for high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches of size 90 mm suitable for cable protection of size upto 95 sqmm to 150 sqmm HT/LT cable complete all as specified and directed.
Returning & filling in, including spreading and leveling, watering and well ramming in layers n.exc. 25cm all as specified and directed by Engr-in-Charge.
Removing excavated soil n.exc 50 mtr and depositing where directed at a level n. exe 1.5mtr above the starting point all as specified and directed.
Plain cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate for coaping of pole as specified by Engr-in-charge.
Plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation of poles etc all as specified.
M&L Earthing with 600X600X6 mm thick , galvanised steel earth plate electrode buried vertically in ground (Earth pit not less than 2.25 meter deep below normal ground level ) with top edge of plate vertically at a depth ,not less than 1.5 m below ground level connected to and including GI strip of size 32X6 mm by means of bolts,nuts,check nuts, And washer of galvanised steel, Gi shrip to be provide upto the extent of 7.5 m GI strip to be duly connected to metalic bodies of HT/LT equipment with provision of mixture of charcoal dust & common salt packed all ground the earth plate upto MS funnel with wire mesh provided inside concrete earth pit for watering arrangement,complete all as shown on electrical plate no.3 of SSR Part I (2009) and testing on completion.
M&L Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth wire 4.00mm dia by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt ,Earthing lead 4.00mm dia up to 7.5m, 20mm dia medium grade GI watering pipe ,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work complete all as shown in electrical plate No-5 of SSR-1991 (part-I)
S&F in repairs LED 45W street light fitting, pressure die cast aluminium housing, heat resistant toughened glass, IP 66 protection, better optics for unoform distribution, aesthetically designed road luminaire with excellent thermal management, surge protection device 5KV upto rated power 150W complete all as specifide and directed.(Make Crompton, Cat part No LSTP-450CDL-M or equivalnt in Havells/Philips
Material and labour for painting /Repairing with welding including change of hinges of LT pannel board/ LT feeder piller box, indoor/out door type any size/capacity with smoke gray colour synthetic enamel paint one coat over the existing paint after cleaning and removing the dust and durt and cleaning with sand paper complete including writting letters 100 mm height with white synthetic enamelled paint complete with PCC work all as specified and directed at site.
Supply & fix PVC insulated 2 core 1.5 sqmm multistranded aluminium conductor on pole for security light from junction box to street light fititng including making necessaey hole on surface of pole for insertion of 3 core pvc cable inside the pole upto street light fitting as specified & directed. etc complete all as specified and directed.
DURGAI ELECTRICALS
KOYNA ENGINEERS PVT LTD
P C DAVE AND SONS
M/S SANTOSH CONSTRUCTION CO
M/s Anil Builders
SHRI SULAI ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .