Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.9 LAccepted-AOC PULGAON | L1 | Accepted-AOC Lowest bidder Amount After deducting schedule of credit | |
| 2 | L2₹44.6 L+₹3.6 L (8.84%)Rejected-AOC 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹50.8 L+₹9.8 L (24.0%)Rejected-AOC | L3 | Rejected-AOC Not Lowest | |
| 4 | L4₹52.6 L+₹11.7 L (28.5%)Rejected-AOC 011 NAGAREWADI 612 NAGAREWADI POST PADALI TALUKA SHIRUR KASAR DISTRICT BEED 413249 BEED MAHARASHTRA 413249 UDYAM MH 05 0079863 | BEED | MAHARASHTRA | 413249 | L4 | Rejected-AOC Not Lowest |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
26 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE NAGPUR
Commander Works Engineers Bldg No. P-9, Sitabuldi Fort, Nagpur-440 001 Pin-900419, C/o 56 APO
REPAIRS / REPLACEMENT OF LIGHTENING PROTECTION SYSTEM IN SUB DEPOT A, B, C, D, E AND F AT DEPOT AREA UNDER GE PULGAON
2023_MES_599359_1
86493/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE PULGAON
As per documents
7 documents required · 7 mandatory
₹500
GE PULGAON
₹1 L
30 Jun 2023
29 May 2023
27 Jun 2023
29 May 2023
26 Jun 2023
12 Jun 2023
Amount
Supply and fix in repair of air termination single pointed aluminium rod of 12 mm dia and 300mm long connecting to conductors including taking down existing damaged unserviceable rod complete all as specified and directed.
Supply and fix in repair of air termination single pointed copper rod of 12 mm dia and 300mm long connecting to conductors including taking down existing damaged unserviceable rod complete all as specified and directed.
Supply and fix in repair of copper strip 20mm x 3mm with saddles and fixing screw etc., for roof conductor and down conductor along the walls including taking down existing damaged unserviceable strip complete all as specified and directed.
Supply and fix in repair of aluminium strip 25mm x 3mm with saddles with support insulator of same size and fixing screw etc for roof conductor and down conductor along the walls including taking down existing damaged unserviceable strip complete all as specified and directed.
Dismantling and re-fixing the existing aluminium/copper strip of any size after repairing and straightning the same as required with GI saddles and in same size in supports insulators of same size at a distance of min 60 cm or as directed and fixing screws with proper drill machine etc for roof and down conductor complete all as specified and directed. Note:- (i) Insulator will be measured and paid in respective items as supply only. (ii) Arrangement for working at heighted buldings to be carried out by the contractor and rate for this is deemed to be included in the quoted rates.
Taking down existing bent air terminals aluminium/copper rod of any size and refixing the same properly after repairing and straightning with new flat iron 25mm x 5mm thick and 40cm long with new nut and bolts, clamps etc fixed / clamped to existing GI pipes/poles complete all as specified and directed.
Supply and fix in repair test point terminal block made out of gun metal or phosphorous bronze of size 75mm x 75mm x 25mm, drilled and screwed including 03 Nos 8mm dia 25mm long hexagonal head screws including taking down existing damaged unserviceable block complete all as specified and directed.
Supply and fix in repair PVC rectangular block of size 100 x 100mm and 50mm deep thickness not less than 3mm to accommodate test terminal block 75x75x25mm including taking down existing damaged unserviceable box complete all as specified and directed.
Supply and fix in repair GI earth continuity conductor 4mm dia fixed to wall on batten or recess or chases or drawn in conduit/ pipe or fix to pole or any other situation for loop earthing etc including taking down existing damaged unserviceable conductor complete all as specified and directed.
Restringing of existing copper ropes of size 8 SWG or 4mm dia 7 wire binding to shackle type insulators including fixing clamps with new nut & bolts to roof post complete all as specified and directed.
Supply and fix copper ropes of size 8 SWG or 4mm dia 7 wire binding to shackle type insulators including fixing clamps with new nut & bolts to roof post complete all as specified and directed.
Supply and fix in repair shackle type porcelain vitreous, white insulator for working pressure 1100 volts of 90mm dia and 75 mm height including galvanised mild steel strips of 30mm x 3mm size 12mm dia insulator, bolts, washers, nuts etc complete all as specified and directed.
Supply and fix in repair GI pipe 40mm bore light grade including bends, sockets etc for earth strip laid in ground/floor, fixed on wall with proper clamping complete all as specified and directed.
Material and labour for PCC 1:3:6 type C1 (using 20mm graded stone aggregate) for making block of size 400x 400x 200mm or any size as specified including necessary form work if any for fixing GI pipe /air termination rod complete all as specified and directed.
Testing of lightning conductor earth resistance by using earth tester in presence of depot user representative and MES representative and record the reading in user register & MES register respectively and duly countersigned by OC of users and AGE E/M complete all as specified and directed. Note:- (i) Testing of lightning conductor for subsequent half year ending. (ii) Contractor has to submit testing sheet of earthing of each sub depot duly signed by sub depot Cdr/ users rep with stamp. (iii) Ser. no of earth testers which is used by the contractor for conducting of testing of lightning conductor. Earth resistance should be submit before starting of testing at Depot area. (iv) Callibration test certificate for given ser. No should be submit by the contractor before starting of testing at Depot area. (v) Calibration test shall be measured and paid separately.
Material and labour for calibration test for Digital Earth tester having range 0-10 Ohm and 0-1000 Ohm and submit the test report to Engr-in-Charge complete all as specified and directed. Note :- (i) Calibration test will be carried out by the NABL approved lab. (ii) Calibration test shall be carried out twice in the contract period and rates for this are deemed to be included in unit rate quoted by the contractor. (iii) Calibration test for minimum two number Earth Tester used by the contractor are deemed to be included in unit rate quoted by the contractor.
Material and labour in repair for earthing complete with copper earth plate electrode of size 60cm x 60cm x 3.15mm buried directly in ground (earth pit not less than 2.25mtr below the normal ground level) with top edge of plate not less than 1.5m below the normal ground level connected to copper earth strip 20x3mm size as earth lead by means of copper , bolts, nuts, check nut and washers of galvanised iron or steel protected by GI pipe, medium grade, 32mm bore all as shown on electrical plate No 3 of SSR Part-I connected to earth test point electrode, PCC pit with RCC cover, funnel with wire mesh, watering pipe 20mm dia, medium grade etc and testing on completion complete all as specified and directed. Note:- (i) The unit rate shall also include for earth work in hard/dense soil, PCC (1:3:6) type C-1 chamber, RCC (1:2:4) type B1 cover 50mm thick reinforced with 8mm dia TMT bar @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe medium grade 32mm dia and wire mesh and adequate quantity of charcoal and salt complete. (ii) Rate of copper earthing strip and GI protection pipe up to 7.5m shall be included in unit quoted rate of this item.
Material and labour in repair for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground (earth pit not less than 2.25mtr below the normal ground level) with top edge of plate not less than 1.5m below the normal ground level connected to GI earth strip 20x3mm size as earth lead by means of bolts, nuts, check nut and washers of galvanised iron or steel protected by GI pipe, medium grade, 40mm bore all as shown on electrical plate No 3 of SSR Part-I connected to earth test point electrode, PCC pit with RCC cover, funnel with wire mesh, watering pipe 20mm dia, medium grade etc and testing on completion complete all as specified and directed. Note:- (i) The unit rate shall also include for earth work in hard/dense soil, PCC (1:3:6) type C1 chamber, RCC (1:2:4) type B1 cover 50mm thick reinforced with 8mm dia TMT bar @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe medium grade 32mm dia and wire mesh and adequate quantity of charcoal and salt complete. (ii) Rate of GI earthing strip and GI protection pipe up to 7.5m shall be included in unit quoted rate of this item.
Material and labour in repair for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground (earth pit not less than 2.25mtr below the normal ground level) with top edge of plate not less than 1.5m below the normal ground level connected to GI earth lead of 4mm dia wire by means of bolts, nuts, check nut and washers of galvanised iron or steel protected by GI pipe, medium grade, 15mm bore all as shown on electrical plate No 3 of SSR Part-I connected to earth test point electrode, PCC pit with RCC cover, funnel with wire mesh, watering pipe 20mm dia, medium grade etc and testing on completion complete all as specified and directed. Note:- (i) The unit rate shall also include for earth work in hard/dense soil, PCC (1:3:6) type C1 chamber, RCC (1:2:4) type B1 cover 50mm thick reinforced with 8mm dia TMT bar @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe medium grade 32mm dia and wire mesh and adequate quantity of charcoal and salt complete. (ii) Rate of GI earth wire and GI protection pipe up to 7.5m shall be included in unit quoted rate of this item.
Material and labour for earth pit outer size 450mm x 450mmx 450mm in height and inner size 300mm x 300mm x 300mm in height with PCC (1:2:4) type B-1 ( by using 20mm graded stone aggregate) and one number suitable size RCC (1:2:4) type B-1 cover 50mm thick reinforced with 8mm dia TMT bar @ 100 c/c both ways including excavation, returning filling etc., complete all as specified and directed. Note:- Unit rate shall also include for excavation / earthwork in hard /dense soil.
Supply and fix in repair galvanised iron strip 32mm x 6mm as earth continuity conductor, beyond earth test point or as ring conductor fixed to wall on GI saddles or buried in ground or drawn in pipe or any other situation including taking down existing damaged unserviceable strip complete all as specified and directed.
Supply only insulator (Epoxy) DMC connector for strip 25x3mm with brass nut, bolt and washer complete on a distance of 60cm complete all as specified and directed.
Supply only insulator (Epoxy) DMC connector for strip 32x6mm with brass nut, bolt and washer complete on a distance of 60cm complete all as specified and directed.
Supply and fix and testing elapp Brass copper lightning arrester 5/8' diameter and 1m in length with 5 spikes and base plate for building protection coverage 45 degrees from top point of the arrester complete all as specified and directed.
Material and labour for mild steel cross arms (not less than 40x40x6mm size) bracings support, clamps and back plates fabricated from structural steel sections, iron rod and channel including nuts, bolts, washers welding, bending cold or not, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
NOTE : SCHEDULE OF CREDIT (Amount on page No 39 shall be deducted offline from the total quoted amount to arrive at the net contract sum to be considered for acceptance [(-) Rs 8,06,790.00 /- ].
metro electrical services
M/s MM TRADERS
MAHARASHTRA ENTERPRISES
Bidder Name
MAHARASHTRA ENTERPRISES
metro electrical services
M/S Maa Durga Constructions,Pulgaon
M/s MM TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .