Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.6 CrAccepted-AOC BARPETA | BARPETA | ASSAM | 781301 | ₹10.6 Cr | L1 | Accepted-AOC Work Order Issued |
Tender Value
₹9.2 Cr
EMD Value
₹18.5 L
Closing Date
29 Oct 2019, 2:00 pmClosed
CE, PWD (Bldg), Assam, Chandmari, Ghy-3
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
Renovation, Construction and Up-gradation of Sports Complex Venues in connection with Khelo India Youth Games, 2020 at Guwahati, Assam Sarusajai Sports Complex
2019_PWBNH_14491_1
Khelo India Gr-I (RT)
Open Tender
Civil Works - Building
Item Rate
60 days
Guwahati
Please refer Tender documents.
6 documents required · 6 mandatory
₹12,500
Assam State Road Board Maintenance (Road) Fund
₹18.5 L
Yes
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
21 Sept 2020
23 Oct 2019
29 Oct 2019
23 Oct 2019
29 Oct 2019
23 Oct 2019
25 Oct 2019
Amount
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Upto a depth of 2.00 m below the existing G.L. In ordinary soil
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (d) With stone dust obtained by truck carriage including loading and unloading to the site of work.
Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royelty, sales tax, land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified. (a) Within Guwahati city only
Supplying and filling sand gravel in foundation trenches of column footings over slushy soil including local carriage of materials within 8 km pumping out of water, ramming etc. complete for strengthening the bearing capacity of the soil as directed and specified including payment of Forest Royalty and Sales Tax and other duties and taxes as may be necessary.
Extra lead per km truck carriage for sand gravel beyond the initial lead of 8 km.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement: 3 sand :6 coarse aggregate by volume
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (i)Using mixture machine (A)In sub - structure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser b) M20 grade concrete or Prop. 1:1.5:3
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (i)Using mixture machine (B) In super structure from plinth level up to 1st floor level. ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing.level. N) Without using admixture, plasticiser b) M20 grade concrete or Prop. 1:1.5:3
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (a) Using 38mm thick plank
Sides of tie beams, grade beams etc. at or below ground level. (a) Using 38mm thick plank
Columns, Pillars, Posts & Strut. (a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face. (i) Using 38mm thick plank
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. For depth not exceeding 1.0M. (i) Using 38mm thick plank
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. Floors etc. upto 200mm in thickness. (i) Using 38mm thick plank
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a).Brick on flat soling.
Filling sunken floor with broken jhama brick bats and sand including compacting and supplying of materials complete as specified and directed for all levels.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-structure upto plinth level including dewatering if necessary. (b) In proportion 1:4.
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall. (a) In cement mortar in proportion 1:4. (1 cement:4 sand)
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (b) 20 mm thick
Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department). i) Of size 300mmx450mm and above
Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department). iii) Of size300mmx600mm and above
Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. VITRIFIED iii)Executive range-2 (Sizes 600 mm x600mm and above) i) Nitco made e). PVT- Hi Polish- PGVT
Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. VITRIFIED i)Normal range (Sizes 300 mm x 300mm and above) Somany made- Durastone (Unpolished heavy duty Vitrified Tiles) a). Premium
Providing,fitting and fixing Loop pile carpet from Uniproducts (India) Ltd.of thickness not less than 4mm with maximum 7mm pile height with pile fibre of 100% BCF polypropelene of width 3.66m laid on existing concrete floor with approved transparent polythene and foam sheet to make the floor surface even and sound free complete as directed and specified. vii) Galaxy Brand
Providing,fitting and fixing wooden flooring from Uniproducts (India) Ltd.of thickness 14mm made of pure wood(Engineered Wood) of different types with a top layer of 3mm thick hard wood and Under layer of 2mm thickness made of polythene and foamsheet laid on existing concrete floor complete as directed and specified Engineered Wood (New) from Uniproducts(India) Ltd. i) Walnut Brand
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. B) On fair side b) In cement mortar 1:4
20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. A) On rough side (backing coat 15 mm and finishing coat 5mm thick) b) In cement mortar 1:4
Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/F Suspended Ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 457mm c/c, 9.5mm/ 12.5mm tapered edge Gypboard (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed. (For light fittings, providing opening for doors, window, ventilators etc, cut out made with frame of perimeter channel supported suitably to be measured and paid separately where necessary). 12.5mm thick
Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) wall lining which includes 12.5mm thick Louvertone/ Sundance/ Cratone/ Fulltone (slit) Gypboard ceiling panels of size 595mmx595mm (conforming to IS:2095-1982) screw fixed to the Ceiling section of size 0.55mm thick having a knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm made of G.I. Steel placed at 298mm c/c in perimeter channels of size 0.55mm thick having one flange of 20mm and flane of 30mm and a web of 27mm made of G.I. Steel fixed to the floor & ceiling with nylon sleeves & wood screws at 600mm c/c. Finally the boards are to be jointed and finished so as to have a Flush look which includes filling and finishing with jointing Compound, joint paper tape, two coat drywall top coat suitable for Gypboard complete as specified and directed at all levels (Glass wool to be measured and paid separately) (For light finishing, skirting providing opening for doors, windows, ventilators etc. cut out made with the frame of perimeter channel supported suitably to be measured and paid suitably when necessary). (A)M/F wall lining with Design Type Semi Perforated (Sundance) Gypboard 12.5mm thick (NRC value=0.20 with 50mm glass wool mat backing).
Providing Pre Painted Galvalume Sheet Roofing (PPGL) at all levels including fitting and fixing self drilling, self tapping screws complete (Roof trusses, purlins etc. to be measured and paid separately.) TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement. (iii) 0.50 mm thick
Providing Pre Painted Galvalume Sheet (PPGL) accessories ( Ridges / Valley / Gutter / Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete. TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement (iii) 0.50 mm thick
Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. (a) With sal wood
Providing barge board of size 200mm x 20mm with 1st class local Hollock/ Bonsum timber including fitting and fixing with necessary wood screws etc. complete.
Providing, fitting and fixing factory made Santro Flush door shutters having core & cross bands fabricated from seasoned 1st class timber, 25mm core battens, 2.5mm to 3.5mm uniformly thick cross bands, styles & rails made from hardwood timber of width not less than 50mm, fixed to the door frames (chowkath) with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately.) 35mm thick
Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. 2 Track sliding window. (i)6mm clear glass
(a) Removing white or colour wash by steel wire brushing and/ or scraping, sand papering and preparing the wall surface smooth including necessary repairs to scratches complete.
b) Extra over item no (a) above for scraping on ceiling and on sloping roof.
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) (i) Thickness = 1.5 mm thick
Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Extra over item no 13.4.1 above for every subsequent coat of wall painting with acrylic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). (a).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. With ready mixed paint , wood primer (white).
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. (i).Surfaces over 100mm in width or girth. b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Extra over item no13.6.5and 13.6..6 for every subsequent coat of paint. (i).Surfaces over 100mm in width or girth. b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i).Surfaces over 100mm in width or girth. b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i).Surfaces over 100mm in width or girth. a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Extra over item no.13.7.4 and 13.7.5 for every subsequent coat of paint. (i).Surfaces over 100mm in width or girth. b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Extra over item no.13.7.4 and 13.7.5 for every subsequent coat of paint. (i).Surfaces over 100mm in width or girth. a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Finishing old/ new wall with water proofing weather coat smooth anti-fungal exterior painting of Apex brand of Asian Paints and of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
Supplying, fitting, fixing Stainless Steel fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary c.p. brass screws etc. complete.( bright natural matt & satin finished ) a) Sliding door bolts. i) 300mm x 16mm
b) Tower bolts ii) 250mm x 10mm
c) Door Handle iii) 150mm
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) v) pin cylinder Mortise Lock Oliver/Matiz/Victoria -Godrej make
Providing,fitting and fixing Door closer of various type UL listed and fire rated good quality depending on the door specification.Types like single speed,Double Speed,Heavy Duty etc are available and as directed & specified by the department. c) Heavy Duty Door Closer( size 180 mm x 65mm x 64mm)
Providing,fitting and fixing Floor Spring of various weight & type UL listed and fire rated good quality depending on the door specification.Types like single speed,Double Speed,Heavy Duty etc are available and as directed & specified by the department. B) Godrej a) Fire rated floor spring B 803( size 307mm x 109mm x 40mm)- 80 kg door/ B 804( size 307mm x 109mm x 40mm)-100 kg door (Godrej make)
Supplying, fitting and fixing MAC blinds horizontal and vertical complete as specified and directed by the department at all levels. (A) Vertical blinds (a) Regular ii) 89 mm
Providing and fixing clear sheet glass beded in putty and fixed with/without wooden bidding including necessary cutting and glass to be required sized(payment for wooden bead shall be made separately) (2). Area of glass panes exceeding 0.15m2 but not exceeding 0.52m2. (c). 5.00mm thick.
Supplying, fitting and fixing chain link fencing of 10 S.W.G, G.I. Wire 50mm x50mm mesh fitted to M.S angle iron post at 2000mm apart of specification detailed below including supplying, fitting and fixing hooks, eye bolts with nuts, staples and bolts including three horizontal lines of G.I wire 10 S.W.G at top,middle and bottom and with one vertical line to each fencing post for keeping the fencing tight and erect complete, including one coat of primer painting to M.S angle iron post in P.C.C base etc. with following. a) Corner and end posts with M.S angle of size 50mmx50mmx 5mm and length not less than 1800mm only duly slotted and bottom torqued with two numbers as stay posts. b) Intermediate post with M.S angle of size 40mmx40mmx5mm and length not less than 1800mm only duly slotted and bottom torqued and splayed. c).Stay post with M.S angle of size 35 mmx35mmx5mm and length not less than 1800mm duly slotted and bottom torqued and splayed. All M.S angle iron posts are to be fitted to P.C.C base embedded not less than 600mm (P.C.C. work shall be measured and paid separately).
Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from 40mm x 40mm x 6mm M.S. angle and with M.S. flat of 40mm x 6mm size as per approved design.Necessary locking arrangement for temporary closing the gate and 2nos.( minimum) strong iron hinges of M.S bars and flat of same sizes on each leaf to be embedded in C.C brick pillers as necessary including a red oxide painting to all iron works as directed and specified.(Separate payment will be made for posts).
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL (ii)Super Ductile (SD) TMT reinforcement bars
Providing, fitting, hoisting and fixing of roof trusses fabricated using any one or conmbination of following sections of (i) Square (ii) Rectangular Hollow section of specification SHS/RHS and including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. b) Using other ISI marked approved brand tube
Providing and fixing Stainless Steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i.e. fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in-charge. (For payment, only weight of Stainless Steel member is to be considered. No extra payment for fixing accessories such as nuts, bolts, fasteners etc. will be considered)
Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
Providing drain with cement concrete (1:3:6) 10cm thick sides 10cm thick bed over brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. ii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
Preparing the RCC surface in roof slab, chajjas, terraces, sunken slabs, septic tank, OH tank, raft slab, walls etc. by thoroughly cleaning with wire brush etc. followed by power washing for making the surface absolutely free from any foreign particles like dust, oil, grease etc. and allowing surface to dry complete as directed at all levels.
Supplying, mixing, laying and applying the following waterproofing systems over Raft slabs, Roof slabs, Terraces etc. including curing complete as specified and directed by the Department at all levels.: (i) 1mm thick single coat of Master Crete M-81 of Choksey Chemicals /Dr. Sealkit Sealcrete (Asian Chemicals)/RHEOMIX 131of BASF mixed with cement in the ratio 1:2 as a prime coat. (ii) 3mm thick Polymer modified mortar - Cement sand mortar (in prop 1:3) mixed with Master Crete M-81/Dr. Sealkit Sealcrete (Asian Chemicals)/RHEOMIX 131of BASF @ 15% by weight of cement. (iii) 1mm thick coat of Master Crete M-81 /Dr. Sealkit Sealcrete (Asian Chemicals)/RHEOMIX 131of BASF mixed with cement in the ratio 1:2 as final coat. (A) Using Master Crete M-81 of Choksey Chemicals /Dr. Sealkit Sealcrete (Asian Chemicals)
Providing treatment of expansion joints by the following process as specified and directed by the department. (a) Preparation of groove by nosing the groove in required sizes with Polymer modified mortar - Cement sand mortar (in prop 1:3) mixed with Master Crete M-81 of Choksey Chemicals /Dr. Sealkit Sealcrete (Asian Chemicals) /Rheomix 115 of BASF@ 15% by weight of cement over a bonding coat of Master Crete M-81/Rheomix 131 of BASF mixed with cement in the ratio 1:2 as specified & directed by the Department complete after proper surface preparation including cleaning/ chipping removing all sorts of loose particles and foreign materials and cleaning surface thoroughly (surface preparation including thorough cleaning of surface to be measured and paid separately).
(b) Providing and applying two coat of Techseal RDL 942 Primer in both surface of the expansion joint followed by applying Tech seal 940 Polysulphide sealant on vertical joint surface after proper fixing of the necessary backup materials as specified and directed by the Department complete.
(d) (Upto 40 mm: ) Providing and applying two coat of Masterflex Primer in both surface of the expansion joint followed by applying of one component Polyurathene based joint sealant MASTERFLEX 472/474 of BASF India Ltd, which is having specific gravity of 1.30gm/cm³, elongation at break will be > 600% and recoverability will be > 80% joint surface after proper fixing of the necessary backup materials as specified and directed by the Department complete.
Dismantling wood work in frames, trusses, purlins and rafters including stacking the materials as directed by the department for all levels.
Dismantling all types of corrugated/ trapezoidal sheet roofing including ridges, hips, valleys and gutters etc. and stacking the materials as directed by the department for all levels
Demolishing mosaic floor of various thickness, both mosiac tiles and cast-in-situ type including CC base course and removal of debris as directed for all levels.
Surface dressing of ground including removing vegitation and/ or undulation of ground not exceeding 150mm deep and disposal of rubbish outside the periphery and lift up to 1800mm in all kinds of soil.
Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Diluting and injecting aqueous emulsion for post constructional anti - termite treatment (necessary tools and accessories to be supplied by the contractors). (c) Treatment of soil under existing floors using aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or equivalent) and water @ 0.50 litre per hole, 300mm apart including drilling 12mm diameter holes and plugging with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floor. (Cement mortar to be measured and paid separately). (Minimum depth of hole should be 300mm). i) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
(e)Treatment at points of contact of wood work by aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or equivalent) and water @ 0.50 litre/hole by drilling 6mm dia holes at downward angle of 45 degree at 150mm centre to centre and sealing the same. i) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Supply, Installation, Fixing of DRY CHEMICAL POWDER Fire Extinguisher confirming to IS: 2171 with ISI mark and CO2 cartridge will be confirming to IS: 4947 with ISI mark, Powder will be confirming to IS: 4308 with ISI Mark (5 KG) BRAND : FIRESTOP / FIREND / FIRE SHIELD
Supply, Installation, Fixing of ABC Stored Pressure Fire Extinguisher with built – In pressure Gauge to know the Ready ness of the Extinguisher Squeeze Grip Handle As per IS:13849 with ISI mark (05 kg capacity) BRAND : FIRESTOP / FIREND / FIRE SHIELD
Refilling & Servicing of DCP Type 05 Kg Capacity Fire Extinguisher with ISI Mark refill etc. complete
Refilling & Servicing of CO2 Type Fire Extinguisher with ISI Mark refill etc. complete (b) 4.5 Kg
Refilling & Servicing of Water CO2 Type 09 Ltrs Capacity Fire Extinguisher with ISI Mark refill etc. complete
Providing and laying of inter locking concrete block pavement (ICBP) with cement concrete paver blocks as per IS 15658-2006 of thickness 80mm and 28 days compressive strength not less than 40 N/m over a layer of bedding sand of compacted thickness 30mm, laid either in stretcher/ running/ herringbone pattern of bonds as directed by the engineer and in proper level and grade and compacted with appropriate equipment such as plat vibrator along with spreading of a thin layer of joint filling sand to fill up the gaps between blocks including construction of edge restraint wherever required complete as per drawings and Technical specification clause 1504 of MORD.
Supplying, fitting and fixing SoundSmooth Ebony (NSS Ebony) with glass wool of Anutone Acoustics Ltd. Including all fixtures and fittings. b) 20 MM
Providing fitting and fixing Vitreous china Dual Flush / Floor Mounted Coupled / Extended water closet (European type W.C pan 400mm high) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) iii) Jaquar make (ii) Opal (Cat. No. OPS-WHT-0310) (inclusive of seat cover and fittings)
Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. (C) Jaquar Make (a) White (i) Compact (Cat.No.URS-WHT-0702)
Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) Counter Top Basin (C) Jaquar Make (ii) Cat. No. CNS-WHT-WB03 (590 x 430 x 200)
Providing fitting and fixing Decorative Mirror complete as directed and specified. (A) Parryware Make (a) Size 800mm x 600mm
Providing fitting and fixing Glass Shelf complete as directed and specified. Glass shelf with C.P. guard rail (iii) Jaquar make (a) Continental 550 mm long (Cat. No.ACN-1171N)
Providing, fitting and fixing CP soap tray / soap dish complete as directed and specified. (i) Jaquar Make (a) Continental (Cat.No.ACN-1331N)
Providing, fitting and fixing Liquid soap dispenser and liquid soap container complete as directed and specified. (i) Jaquar Make (b) Continental (Cat.No.ACN-1137N) (with mettalic bottle)
Providing, fitting and fixing CP towel rail complete as directed and specified. (a) Jaquar make (ii) Continental 600mm (Cat.No. ACN-1111N)
Providing, fitting and fixing Chrome Plated towel rack complete as directed and specified. (a) Jaquar make (i) Continental 600mm long with hanger (Cat.No. ACN-1181N)
Providing, fitting and fixing Chrome Plated towel ring complete as directed and specified. (a) Jaquar make (i) Continental towel ring square (Cat.No. ACN-1121)
Providing, fitting and fixing Chrome Plated robe hook complete as directed and specified. (a) Jaquar make (i) Continental (Cat.No. ACN-1191N)
Providing, fitting and fixing Chrome Plated TOILET PAPER holder complete as directed and specified. (a) Jaquar make (ii) Continental toilet paper holder with flap (Cat.No. ACN-1153N)
Providing, fitting and fixing Chrome Plated waste coupling complete as directed and specified. (a) Jaquar Make (i) 32mm (HT/FT) (Cat.No.ALD-705 / 709)
Providing, fitting and fixing Chrome Plated bottle trap complete as directed and specified. (a) Jaquar make (i) Bottle trap (with internal partition) 32mm size with 250mm long wall connection pipe (Cat.No. ALD-769)
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. In exposed surfaces or in trenches. 110mm dia.
Supplying fiting and fixing 87.5 degree PVC bend of (Supreme/Prince) or ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surface or in trenches. - 110mm dia.
Supplying fiting and fixing PVC Plain single tee of (Supreme/Prince) or ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surface or in trenches. 110mm dia.
Providing fitting and fixing 450mm dia. 90mm thick C.I. Man hole cover and frame of 58 Kg. weight complete as directed and specified.
Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table.
Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed.
Supplying fitting and fixing Ajoy Flowguard CPVC (Chlorinated Polyvinyl Chloride) pipes having thermal stability for hot and cold water supply including all CPVC plain and bruss threaded fitting including clamps at 1.00 m spacing including joining of pipes and fitting with one step CPVC solvent cement and testing of joints complete at all levels as directed and specified. (Note: Ball valve and union will be charged extra and does not comes under Accessories) (i) In internal wall - exposed on wall (c) 25 mm OD
(ii) Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to damages (b) 20 mm OD
Supplying fiting and fixing C.P. bib cock 15mm dia of approved brand directed and specified.(G.I. & C.P. pipes will be measured seperatly) Jaquare make (iii)2-Way bib cock
Supplying fiting and fixing C.P. chrome plated (C.P.) stop- cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P. pipes will be measured seperatly) Jaquar (a) Continental / Clarion (ii) 15mm dia( Angular stop cock with long thread )
Supplying fitting and fixing push bib cock 15mm dia complete as directed and specified as follows. (pipes will be measured and paid separately). c) Agmeco make
Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. Jaguar make (b)Long neck with areator
Supplying fitting and fixing Chrome Plated (C.P.) shower 15mm dia. Of approved brand as directed and specified. (Pipes will be measured and paid separately) Jaquar make (iv) Overhead shower (ABS chrome plated) with rubit cleaning system
Supplying, fitting and fixing Chrome Plated (C.P.) divertor of approved brand complete as directed. Jaquar make a)Continental/ Clarion - 4-way divertor for concealed fitting with built in non return valves with divertor handle Cat No.421
Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. c) 25 mm dia.
Providing and fixing Wall panelling at interior partition walls, columns, chowkaths etc. for decorative face, pelmet up to ceiling level from floor level with 12 mm thick Solid plywood board (Green/ Century/ Archid or equivalent) on one side of the wall and finishing with 1mm thick Laminate (Green/ Century/ Archid or equivalent) of approved shade and make as per design fixed with necessary adhesive complete as specified and directed by the Daprtment.
Providing and fitting High Back Wooden Executive Chair with Imported Leather cushioned at Hon'ble Chief Minister Gallery Stand at Indira Gandhi Athletic Stadium, Sarusajai Sports Complex, Sarusajai, Guwahati in all respect as per direction of the department.
Cleaning and painting (Spray painting) with enamel paint of existing bucket seat at West Stand with seat frame over a coat of red oxide primer including reparing of seat in all respect as directed and specified by the department.
Providing and fixing Maple Wood Flooring on floors at Field of Play(FOP) after removing the existing damaged wood flooring at Karmabir Nabin Chandra Bordoloi Indoor Stadium(K.N.C.B.) at Sarusajai Sports Complex of approved shade and make as per design fixed with necessary nails, screws etc. complete as specified and directed by the Daprtment.
Applying matte-polish on previously polish wood and wood based surfaces (Maple wood flooring) with to give an matte finsih surface including cleaning the surface of all dirt,dust, sand papered smooth at Karmabir Nabin Chandra Bordoloi Indoor Stadium(K.N.C.B.) at Sarusajai Sports Complex.
Cleaning and painting (Spray painting) with Artists paint at existing FIFA U-17 World Cup Mascot (KHELEO) with pedestal at Main entrance of the Sarusajai Sports Complex in all respect as directed and specified by the Department.
Cleaning and painting (Spray painting) with Artists paint at existing 33rd National Games Mascot (Rongmon) with pedestal at Main entrance of the Sarusajai Sports Complex in all respect as directed and specified by the Department.
Providing and fixing PVC Moulded erogonomically designed bucket seats with Powder coatd MS structure below for spectator seating. With size 450 (h) x405 9w). Swagath/ Neelkamal/ Equvalent.
Providing & Fixing Dressing Unit (600mm Depth) made up of 19mm Solid Ply for Structure & 12mm Ply at Back with 1mm thk Laminate at Inside & Outside along with Drawer & Ply Shelve at inside the Unit in complete with necessary Hardware as per design or Architect / EIC - Size of Unit: (600mmX600mmX2050mm Height)
Providing & Making Massage Bed made up of 19mm Solid Ply, 12mm Ply along with 1mm thk. Laminate finished at outer surfaces including 75mm thk Mattress with HD Foam with Leatherite finished in complete with necessary Hardware as per design or Architect / EIC
Providing & Supplying E-Locker as specified for site or Architect / EIC - Size of Each Locker (420mm X 370mm X 200mm Height)
Providing & Supplying Three seater Visitor chair with seat and back padding for added comfort and warmth. Edges are not upholstered to prevent fabric damage from trolley bumping, Aluminium powder coated for back and seat, legs will be HIGH POLISHE Aluminium complete in all respect as specified and directed by the department. Monarch make
Providing & Making Service Table made up of 19mm Solid Ply for Top & Vertical Support along with 1mm thk. Laminate finished at outer surfaces & Top should be finished with Granite Slab in complete with necessary Hardware as per design or Architect / EIC Size:6000(L)X 750 (H) X1500 (D).
Supplying and laying of Wooven Outdoor Mid Green Bowling Surface of 1500 g/m2 Bowls underlay which weighs 1050 g/m2 of size 38m (L) x 38m (W) with 0.6m extra on width for fitting after uplifting the existing bowling surface and preparing the base surface for installation including necessary machine stitched complete in all respect for Lawn Bowl Court at Sarusajai Sports Complex, Sarusajai as directed and specified by the department. Product Make: GREENGAUGE SURFACES or any other Equivalent Standard.
Providing and fitting 3 Seater Visitor Chair with arms (Godrej Make) for Player's Dressing Room at Lawn Bowl Court, Sarusajai Sports Complex, Guwahati in all respect as per direction of the department. MODEL:Air 3 Seater with 2 arms Make: Godrej.
Providing and fitting 2 Seater Sofa with arms (Godrej Make) for VIP Lounge at Lawn Bowl Court, Sarusajai Sports Complex, Guwahati in all respect as per direction of the department. MODEL:Pisa 2 Seater Sofa Make: Godrej.
Providing and fitting 1 Seater Sofa with arms (Godrej Make) for VIP Lounge at Lawn Bowl Court, Sarusajai Sports Complex, Guwahati in all respect as per direction of the department. MODEL:Pisa 1 Seater Sofa Make: Godrej.
Providing and fitting Centre Table with Glass Finish (Godrej Make) for VIP Lounge at Lawn Bowl Court, Sarusajai Sports Complex, Guwahati in all respect as per direction of the department. MODEL:Pisa Centre Table Make: Godrej.
Providing and fitting Side Table with Glass Finish (Godrej Make) for VIP Lounge at Lawn Bowl Court, Sarusajai Sports Complex, Guwahati in all respect as per direction of the department. MODEL:Pisa Side Table Make: Godrej.
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including providing and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. marked) with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete. Extra Long point up to 20.00 metre. Length.
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof (IP-43) double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. (ABB, Schneider MG, legrand, Hager, Crabtree xpro make) 8 way TPN (4+24) double door
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. "C Series (Schneider MG, legrand, Hager, Crabtree xpro make)" 1 6 to 32A
Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series (Schneider MG, legrand, Hager, Crabtree xpro make) 63A
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts ( Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in existing surface conduit wiring system including connection as required. With 2 x 1.5 sq. mm. copper conductor cable
With 3 x 1.5 sq. mm. copper conductor cable .
With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. copper conductor cable
With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. copper conductor cable
With 4x 6 sq. mm. + earth continuity with 2x4 sq. mm. copper conductor cable
With 4 x 16 sq. mm. + earth continuity with 2x4 sq. mm. copper conductor cable
Wiring to a 5 pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. marked) with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere. Long point up to 10.00 metre. Length.
Supplying with fitting and fixing of Single Phase Modular Motor Starter switch MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department. Overload Relay Range 16 - 25 Amps in 3 Module
Supplying including installation of socket outlet 6/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.
Supplying including installation of socket outlet 6/10/13 Amps INTERNATIONAL SOCKET , MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.
(CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.
(CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.
Supplying with fitting and fixing panel mounting open execution 25KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 25 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens, Indo Asian make) 100A
Supplying including fitting and fixing of the following Ballast for TL/TL-TD lamps (HF control gear) complete as directed and specified by the deptt. (Philips/Havells/Bajaj make) EBE (Sli 136 TLD 240 for 1 x 36 W/40 W)
Supplying including fitting and fixing of the following Fluorescent tube/T 5 lamps complete as directed and specified by the deptt. (Philips/Havells/Bajaj make) TL 20 W/54-765-ISL/25/IND
TL 40 W/54-765-ISL/25/IND
TURTLE 36 W COLOUR 86/84/82
Supplying including fitting and fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt. as required complete and as directed by the Department. Heavy Duty 600 mm sweep 900 RPM Single phase
Supplying with fitting and fixing of 120 watt electronic modular STEP speed control 2 - module type MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department. 120 watt electronic modular step speed control 2 - module type WHI
Supplying including fitting and fixing of following Moulded PVC boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface system complete as per direction of department. 1-3 module Surface Moulded PVC boxes
8 module surface Moulded PVC boxes
12 module horizontal surface Moulded PVC boxes
Supplying including fitting and fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department. 3 module
8 module
12 module
Supplying including fitting and fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt. as required complete and as directed by the Department [ without regulator]. Premium model 1200 mm Sweep (ORIENT PSPO make) / Premium model 1050 / 1200 mm Sweep SS-390 Deco (Havells make)
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Grade Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make or equivalent) . 3 & 1/2 Core A2XFY 50.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
Supplying, fitting and fixing of Single Phase Fan Motor of 1.00 Ton to 2.00 Ton capacity Split type Air Conditioner Machine
Gas Charging of Split type A.C. with F-22 fresh refrigerant 2.00 Ton Capacity
5.00 Ton Capacity
11.00 Ton Capacity
Supplying with fitting and fixing rebuilt Rotary compressor in exchange of existing burnt out compressor complete with overhauling the Machine, Gas charging with fresh refrigerant and testing etc complete 2.00 Ton Capacity
Supplying with fitting and fixing of Running capacitor in exchange of the existing for the Split type A.C.
Supplying with fitting and fixing PCB in exchange of existing burnout PCB of the following A.C. machine 2.00 Ton Capacity
Copper pipe including cable fitting ( 1/4, 1/2, 5/8)
Dismantling & shifting of existing A.C. Machine 2.00 Ton Capacity
Supplying fitting and fixing of transformer bushing
Heat curing and tanking of transformer
Oil filter and filling after dehydration of transformer
Supplying fitting and fixing of transformer new gasket set complete
Cleaning, painting, varnishing oftransformer tank both inside and outside
Testing of transformer
Supplying and fixing of 11 KV 400 A Gang operated switch with all accessories complete as required and as directed by the department.
Supplying and fixing of 11 KV 150 A D.O. fuse set complete as required and as directed by the department
Supplying and fixing of 11 KV 5 KA Lighting arrestor (Poly) set complete as required and as directed by the department.
Transformer oil refilling
Supply and laying of following numbers and size of armoured cable in same trench, PVC/XLPE insulated and PVC sheathed 1.1 KV Grade Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, unarmoured/Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make or equivalent) . 4x630.00 Sq. mm. 1 Core armoured U.G. cable
One time Servicing of 1X500 KVA DG set at Sarusajai Sports Complex, Guwahati (Providing Servicing , Testing & changing of Lube Oil, Coolant, Lube Oil Filter etc from the Caterpiller Authorised Service Personnel only . including one service personnel during the event)
One time Servicing of 1X600 KVA DG set at Sarusajai Sports Complex, Guwahati (Providing Servicing , Testing & changing of Lube Oil, Coolant, Lube Oil Filter etc from Caterpiller / Jackson Only Authorised Service Personnel only. including one service personnel during the event)
Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hager, Crabtree xpro make)" 6 to 32A
Supplying with fitting and fixing TPN 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hager, Crabtree xpro make) 63A
Supplying of Metal Halide Lamp 2000watt 12.2 A Double Ended OSRAM HQI -TS-2000W/D/S HF as directed by the Deptt.
Fitting Fixing of Metal Halide Lamp 2000watt 12.2 A Double Ended OSRAM HQI -TS-2000W/D/S HF as directed by the Deptt.
Supplying of Metal Halide Ballast 2060watt 12.2 A GE DHZV944DY-V as directed by the Deptt.
"Fitting Fixing of Metal Halide MH Ballast 2060watt 12.2 A GE DHZV944DY-V as directed by the Deptt."
Supplying of 65 Mfd 440 Vac 105 degree Aluminium Can Lighting Capacitor as directed by the Deptt.
"Fitting Fixing of 65 Mfd 440 Vac 105 degree Aluminium Can Lighting Capacitor as directed by the Deptt."
Supplying of 1000 W-2060 W SIP Igniter for MH Lamp as directed by the Deptt.
Fitting Fixing of 1000 W-2060 W SIP Igniter as directed by the Deptt.
Supplying of 2060 W Medium Beam Flood Light Luminaire (Housing only) VL / AFL / NI / DE-2000W-M (without Lamp Ballast, Igniter) as directed by the Deptt.
Fitting Fixing of 2000/2060 W Medium Beam Flood Light Luminaire VL / AFL / NI / DE-2000W-M as directed by the Deptt.
Operation of High Mast at Indira Gandhi Atletics Stadium, Sarusajai, Guwahati during the Khelo India Youth Games 2020 complete event with competent personnel (Mast Supervisor-1No, Electrician (Spl Climber)-3, Electrician-2 for smooth operation as directed . (Considering 15 days)
Providing new Lift for High mast (amount Reserved as detail of this item not yet received from the manufacturer)
Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hager, Crabtree xpro make)" 6 to 32A
Supplying with fitting and fixing TPN 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hager, Crabtree xpro make) 63A
Supplying of Metal Halide Lamp 2000watt 12.2 A Double Ended OSRAM HQI -TS-2000W/D/S HF as directed by the Deptt.
Fitting Fixing of Metal Halide Lamp 2000watt 12.2 A Double Ended OSRAM HQI -TS-2000W/D/S HF as directed by the Deptt.
Supplying of Metal Halide Ballast 2060watt 12.2 A GE DHZV944DY-V as directed by the Deptt.
"Fitting Fixing of Metal Halide MH Ballast 2060watt 12.2 A GE DHZV944DY-V as directed by the Deptt."
Supplying of 65 Mfd 440 Vac 105 degree Aluminium Can Lighting Capacitor as directed by the Deptt.
"Fitting Fixing of 65 Mfd 440 Vac 105 degree Aluminium Can Lighting Capacitor as directed by the Deptt."
Supplying of 1000 W-2060 W SIP Igniter for MH Lamp as directed by the Deptt.
Fitting Fixing of 1000 W-2060 W SIP Igniter as directed by the Deptt.
Operation of High Mast at Practice Ground, Sarusajai, Guwahati during the Khelo India Youth Games 2020 complete event with competent personnel (Mast Supervisor-1No, Electrician (Spl Climber)-1, Electrician-2, Jugali -4 Nos for smooth operation as directed . (Considering 13 days)
Hire charge of D G set [125kva-1no]
Fuel Diesel (As per Market)
Supplying including fitting & fixing of Exide Battery FE-02-EP65-12 including Terminal in proper place at the for 20 kVA UPS at UPS Room, at Sarusajai Sports Complex as per direction of the department.
Servicing and Replacement of parts of UPS 20KVA APC ONINE UPS.S/N B215520 00056MODEL: SURT20KUXI -IN main IGAS Sarusajai
Servicing and Replacement of parts of UPS 20KVA ETONONINE UPS.S/N 131107-72430013/MODEL:E Series DX 20KVA -IN main IGAS Sarusajai
Servicing and Replacement of parts of UPS 20KVA ETONONINE UPS.S/N 140523-58120009/MODEL:E Series DX 20KVA -IN main IGAS Sarusajai
Supply, Installation, Testing & Commissioning of Fire Alarm hooter with audible range of 25 metre 80 bb output complete. make : (AGNI / System Sensor or equivalent as approved by the Deptt.)
Supply, Installation, Testing & Commissioning of ionization type Smoke Detect with mounting base. make : (Apollo/Notifier/System Censor or equivalent as approved by the Deptt.)
Supply, Installation, Testing & Commissioning of Manual Call box made of M/s. Aluminium dia cast with epoxy coated paint with hammer & chain. make : (AGNI / System Sensor or equivalent as approved by the Deptt.)
Supply, Installation, Testing & Commissioning of Response indicator fitted on suitable type box with cover .
Supply & fixing of 2X1.5sq. mm. PVC insulated copper Armoured Cable on surface/ recess/ above false ceiling etc. as required. (ISI marked) )
Supply, Installation, Testing, commissioning of Loop card for Addressable Panels make- (MORLEY/FIRELITE/Apollo or equivalent as approved by the Deptt.)
Crown (or equivalent as approved by the Deptt.) Supplying installation, testing, programming and commissioning of Audio equipment, Dual Channel Power Amplifier, 550W@ 2ohm. 350w @ 4ohm, 215W @ 8 ohm per channel
JBL (or equivalent as approved by the Deptt.) Supplying installation, testing, programming and commissioning of Audio equipment,8" Open‐Back Ceiling Speaker. 70V/100V taps at 6W, 3W, 1.5W (plus 0.75W at 70V), very high 97 dB sense, 50 Hz to 16 kHz, for non‐plenum applications, 1.4 kg
Refilling & Servicing of DCP Type 05 Kg Capacity Fire Extinguisher with ISI Mark refill etc. complete
Refilling & Servicing of DCP Type 10 Kg Capacity Fire Extinguisher with ISI Mark refill etc. complete
Refilling & Servicing of Water CO2 Type 09 Ltrs Capacity Fire Extinguisher with ISI Mark refill etc. complete
Refilling & Servicing of Mechanical Foam AFFF Type 09 Ltrs Capacity Fire Extinguisher with ISI Mark refill etc. complete
Refilling & Servicing of ABC Type 05 Kg Capacity Fire Extinguisher with ISI Mark refill etc. complete
Refilling & Servicing of CO2 Type Fire Extinguisher with ISI Mark refill etc. complete (c) 6.5 Kg
Supply, Installation, Fixing of DRY CHEMICAL POWDER Fire Extinguisher confirming to IS: 2171 with ISI Mark, and CO2 Cylinder will be confirming to IS: 4947 with ISI Mark, Powder will be confirming to IS: 2878 with ISI Mark (Extinguisher will be TROLLEY MOUNTED)(25 KG) BRAND : FIRESTOP / FIREND / FIRE SHIELD"
Supply, Installation, Fixing of DRY CHEMICAL POWDER Fire Extinguisher confirming to IS: 2171 with ISI mark and CO2 cartridge will be confirming to IS: 4947 with ISI mark, Powder will be confirming to IS: 4308 with ISI Mark (Extinguisher will be TROLLEY MOUNTED).(50 KG) BRAND : FIRESTOP / FIREND / FIRE SHIELD"
Operation of the PA System & attending emmergency Fire alarm calls at IGAS during the event of Khelo India 2020 (Supervisor-1No, Technician-6,with necessary Cell Phones for smooth operation as directed and specified by the department. .
Supplying & laying of 50x6 mm size G.I. strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of G.I. nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
Supply, fitting & fixing of Lighting Finial Arrestor made of 25 mm dia 300 mm long solid Copper tube having 85 mm dia. single prong at top and 3 mm thick base plate at bottom complete with fitting & fixing with Brass nuts & bolts on roof, RCC slab, top of column etc. as specified and directed by the deptt. "
Supply, fitting & fixing 20 mmx3 mm Copper strips drawn on vertically or horizontally on building wall/parapet wall in surface system complete with supply of Brass Nuts & Bolts, Screws etc including riveting, soldering and making connection as approved by the Deptt. with earth electrode copper strips and Lightning Arrestor etc. as specified and directed by the deptt. "
Supply with installation & commissioning of readymade maintenance free CPRI approved chemical earthing system with 50 mm dia. 3.00 Metres length corrosion free Single pipe technology- Copper CHEMRODE ELECTRODE complete with RESLOW Grounding Minerals 25 K and Advance Earth Pit cover PV including excavation of earth pit and construction of brick earth chamber including plastering both inner & outer surface of brick wall as specified and directed by the deptt.
Supply, installation & commissioning of Advanced Lightning protection system by using High pulse Voltage ESE Lightning conductor with Optimized Pulse Rod (ABB or equivalent make) as specified and directed by the deptt (as per NFC 17 - 102 STANDARD & IEC Std 60 - 111989)
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Grade Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make or equivalent) . 400.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
400.00 Sq.mm 3&1/2 Core U.G. cable in 125mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.)
SUPPLYING FITTING AND FIXING OF (DOWELLS/ COMET make) DOUBLE compression BRASS GLANDS WITH NICKEL - PLATED WEATHERPROOF (CBW) Size: 8 - 10, 3/4 "
Operation of the Electrical Panel Board, Switching ON / OFF Air conditioner System & attending emmergency calls at IGAS during the event of Khelo India 2020 (Supervisor-1No, Electrician -7, Jugali-7 nos, UPS Service personnel-1with necessary Cell Phones for smooth operation as directed and specified by the department. .
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Grade Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make or equivalent) . 95.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
Supplying with fitting and fixing MCCB incomer and MCB outgoing sheet steel, phosphatised, powder painted double door (IP-43) surface mounting vertical TPN MCB DB incorporated with bas-bar up to 250 A , Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 12 way TPN (4+36) double door
Supplying with fitting and fixing panel mounting open execution 35/36KA 415V 50Hz 3P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 35/36 KA 415V 50 Hz 3P MCCB (ABB(S6) , Schneider, legrand, Siemens, L&T D-shine make) " 160A
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Grade Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make or equivalent) . 4 Core A2XWY A2XFY 25.00 Sq. mm.4 Core armoured U.G. cable
4 Core A2XWY A2XFY 16.00 Sq. mm.4 Core armoured U.G. cable
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series (Schneider MG, legrand, Hager, Crabtree xpro make)" 6 to 32A
Supplying testing and commissioning of Power Contactor in the existing control panel as specified and directed by the department( D Model 3 Pole 63A, AC, Schneider make)
Supplying testing and commissioning of Timer in the existing control panel as specified and directed by the department ( MINS, Schneider make)
Supplying including installation, connection cable, as approved by the Deptt. with 2x2.5 sqmm copper FR CABLE, testing and commissioning of the following street light on existing pole/ Structure including lamp, driver, ballast as required complete as directed and specified by the deptt. Philips lighting luminaire 36w GreenLine Model BRP409 LED CW 036 MR FG S1 PSU GR /BRP409 LED CW 035 NR FG S1 PSU GR or equivalent as approved by the Deptt.
Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series (Schneider MG, legrand, Hager, Crabtree xpro make) 40A
Supplying and installation and commissioning of vermin and dust proof totally enclosed double door cubical type compartmental floor mounting panel board of size 1.20 m ×1.00 m ×0.50 m made of 16 SWG (1.66mm) thick CR sheet and 35 mm × 35 mm × 6 mm size angle and 35 mm ×6 mm flat iron having 4 nos legs at the bottom and G.I. Sheet reefing on the top complete painting with 2 coats of red oxide metal primer and 2 coats of enameled paint. The panel board is to be erected in 1:3:6 RCC pole foundation including excavation of trench and brick soling etc. complete neatly internal wiring done as specified and directed by the department comprising of the following electrical items. 1. 40 Amp 4 pole 415 Volt 50 Hz MCCB as incomer - 1 no 2. 32 Amp 2 pole open execution with HBC fuse SDFU unit as outgoing - 3 nos. /32 A DP MCB 3 Nos/ 32A DP RCBO 3 NOS. 3. 25 mm × 5 mm size 4 strip copper Bus-Bar- 1 set 4. 40 Amp 4 pole ON-OFF poser contactor - 1 No. 5. Surface mounting timer switch - 1 No. 6. 63 Amp bakelite HBC fuse kit-kat - 3 Nos
Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Supplying & laying of 6 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
Supplying including installation with required bracket, connection cable, as approved by the Deptt. with 2x2.5 sqmm copper FR CABLE, testing and commissioning of the following street light/ FLOOD LIGHT on existing pole/ Structure including lamp, driver, ballast as required complete as directed and specified by the deptt. Philips Flood lighting luminaire 107W with high power LED and unique flood optics to ensure uniform distribution Model BVP410 LED 107 CW HE NB FG S3 XT or equivalent as approved by the Deptt.
Temporary Electrical works:- Hire charge of 1x40 w patty type tube light fittings with tube including Wiring with 1.5 sq mm p v c insulated aluminium conductor cable in open system as directed by the Deptt (Installation charge)
Hire charge of 1000 w halogen light fittings with bulb including Wiring with 2x6 sq mm p v c insulated aluminium conductor cable in open system as directed by the Deptt (Installation charge)
Hire charge of 250 w metal halide flood/street light fittings with bulb including Wiring with 2x4 sq mm p v c insulated aluminium conductor cable in open system as directed by the Deptt (Installation charge)
Hire charge of main /sub main line with the p v c insulated aluminium conductor cable in open system complete with drawing cable as directed by the Deptt (Installation charge) a. 2x2.5 sq mm
b. 2x4 sq mm
c. 2x6 sq mm
d. 2x10 sq mm
e. 4x10 sq mm
Hire charge of underground armoured cable including drawing of cable as directed by the Deptt (Installation charge) a. 16 sq mm p v c insulated aluminium conductor cable 4core
b. 25 sq mm p v c insulated aluminium conductor cable 3.5 core
c. 35 sq mm p v c insulated aluminium conductor cable 3.5 core
Hire charge of SPN switch fuse unit which should be fitted on wooden /M/ S frame of the following capacity as directed by the Deptt (Recurring charge) (Installation charge). 16 Amp capacity
.32 Amp capacity
Hire charge of TPN switch fuse unit which should be fitted on wooden /M/ S frame of the following capacity as directed by the Deptt (Recurring charge). a. 32 Amp capacity
b. 63 Amp capacity
c. 100 Amp capacity
Hire charge of distribution box which should be fitted on wooden /M/ S frame of the following capacity as directed by the Deptt (Installation charge) a. 2 way capacity
b. 4 way capacity
Hire charge of 4 pole bus bar chamber which should be fitted on wooden /M/ S frame of the following capacity as directed by the Deptt (Installation charge) a. 100 Amp capacity , 4 pole
Hire charge of MCB DB which should be fitted on wooden /M/ S frame of the following capacity as directed by the Deptt (Installation charge) a. 4 WAY SP MCB DB
b. 8 WAY SP MCB DB
c. 4 WAY TP MCB DB
Hire charge of Change over Switch which should be fitted on wooden /M. S frame of the following capacity as directed by the Deptt (Installation charge) b. 200 amps TPN
c. 100 amps TPN
Hire charge of 1x40 w patty type tube light fittings with tube including Wiring with 1.5 sq mm p v c insulated aluminium conductor cable in open system as directed by the Deptt (Recurring charge)
Hire charge of 1000 w halogen light fittings with bulb including Wiring with 2x6 sq mm p v c insulated aluminium conductor cable in open system as directed by the Deptt (Recurring charge)
Hire charge of 250 w metal halide flood/street light fittings with bulb including Wiring with 2x4 sq mm p v c insulated aluminium conductor cable in open system as directed by the Deptt (Recurring charge)
Hire charge of main /sub main line with the p v c insulated aluminium conductor cable in open system complete with drawing cable as directed by the Deptt (Recurring charge) a. 2x2.5 sq mm
b. 2x4 sq mm
c. 2x6 sq mm
d. 2x10 sq mm
e. 4x10 sq mm
Hire charge of underground armoured cable including drawing of cable as directed by the Deptt (Recurring charge) 16 sq mm p v c insulated aluminium conductor cable 4core
25 sq mm p v c insulated aluminium conductor cable 3.5 core
35 sq mm p v c insulated aluminium conductor cable 3.5 core
Hire charge of SPN switch fuse unit which should be fitted on wooden /M/ S frame of the following capacity as directed by the Deptt (Recurring charge). a. 16 Amp capacity
b. 32 Amp capacity
Hire charge of TPN switch fuse unit which should be fitted on wooden /M/ S frame of the following capacity as directed by the Deptt (Recurring charge). a. 32 Amp capacity
b. 63 Amp capacity
c. 100 Amp capacity
Hire charge of distribution box which should be fitted on wooden /M/ S frame of the following capacity as directed by the Deptt (Recurring charge) a. 2 way capacity
b. 4 way capacity
Hire charge of 4 pole bus bar chamber which should be fitted on wooden /M/ S frame of the following capacity as directed by the Deptt (Recurring charge). a. 100 Amp capacity , 4 pole
Hire charge of MCB DB which should be fitted on wooden /M/ S frame of the following capacity as directed by the Deptt (Recurring charge). a. 4 WAY SP MCB DB
b. 8 WAY SP MCB DB
c. 4 WAY TP MCB DB
Hire charge of MCCB enclosure which should be fitted on wooden /M/ S frame of the following capacity as directed by the Deptt (Recurring charge). b. 200 amps TPN MCCB
c. 100 amps TPN MCCB
Hire charge of earth station complete with G I pipe ,6 S W G I cable, salt, charcoal etc. as reqd as directed (Recurring charge).
Hire charge of tuni light set
Hire charge of D G set [125 kva-3nos 63 kva-1no]
20 KVA On-Line UPS System (Orion or equivalent make as approved by the Deptt.) with PWM-IGBT technology 360V AC Input (300V – 470V) 3 Ph input- 1 Ph output with Isolation Transformer 18KW output with 0.8 PF, 60 min backup using SMF battery"
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 16 sq. mm. + earth continuity with 1x 10 sq. mm. cable in 32 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Supplying with fitting and fixing MCCB incomer and MCB outgoing sheet steel, phosphatised, powder painted single door surface mounting vertical TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar up to 125A and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. (ABB, Schneider MG, legrand, Hager, Crabtree xpro make) 4 way TPN (4+12) single door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted Single door surface mounting MCCB enclosure of the following rating MCCB fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. Schneider neo break, C&S, Havells, INDOASIAN, Standard, HPL, V-Guard or equivalent make as approved by the Deptt.) for 125A 3P/4P MCCB
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door (IP-43) surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. (ABB, Schneider MG, legrand, Hager, Crabtree xpro make) 8 way SPN double door
Supplying including fitting and fixing of following Moulded PVC boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface system complete as per direction of department. 8 module surface Moulded PVC boxes
Supplying including fitting and fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE as per direction of department. 8 module
Supplying with fitting and fixing of 6/10 amp one way modular clip in switch with LED , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying, installation, testing and commissioning of the following indoor Decorative recessed typed mirror optics down lighter luminaries complete with all accessories such as ballast, starter etc. In the false ceiling type Armstrong /Gypsum or similar ceiling mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department DNI 9IB LED 12 S 6500 PSU WH/ 4000 PSU WH/ 3000 PSU WH
Supplying installation testing and commissioning of 1/3" Super HAD Colour CCD, 540 TV LINES, 0.3LUX, 3mm Fixed Lens, Auto Iris, Compact, light weight, DC12V (SAMSUNG or equivalent HONEYWELL/PANASONIC make)
Supplying installation testing and commissioning of - 16ch CIF Real Time DVR, H.264, 400 (PAL) fps recording rate , Up to 16ch audio inputs and 1ch audio outputs, Max 5 internal HDD (HDD x 5) , DVD-RW, Built-in web viewer (SAMSUNG or equivalent HONEYWELL/PANASONIC make)
Supplying installation testing and commissioning of - 27x PTZ Dome Camera , 1/4" Super HAD CCD, 600 TVL (Colour) / 700 TVL (B/W), 3.5 ~ 94.5 mm, digital 16x, True Day & Night (ICR), Min Illumination : 0.2 Lux @ F1.6 (Colour), 0.02 Lux (B/W), IP 66 (SAMSUNG or equivalent HONEYWELL/PANASONIC make)
Supplying installation testing and commissioning of IP 66 Housing, External Dimensions 184 x 127 x 460 mm, Internal Dimensions 100 x 80 x 383 mm, Input Voltage 24 VAC, Operating Temp : - 35 deg C ~ + 50 deg C. Used for Box Cameras (SAMSUNG or equivalent HONEYWELL/PANASONIC make)
Supplying installation testing and commissioning of Outdoor PTZ Housing, Operating Temp : - 50 deg C ~ 50 deg C, IP 66, Input Voltage : 24 V AC, Applicable Model : SCP3430 / SCP2430 / SCP3370 / SCP2370 / SCP2330 / SCP2270 / SCP3250 / SCP2250 / SNP5200 / SNP3371 / SNP3302 (SAMSUNG or equivalent HONEYWELL/PANASONIC make)
Supplying installation testing and commissioning of PTZ Control Keyboard, OSD Menu, 3D Joystick Control, 16 x 2 Character LCD (SAMSUNG or equivalent HONEYWELL/PANASONIC make)
Supplying installation of BNC connection per Pair
Supplying installation testing and commissioning of Hard Disk For DVR 2 TB (SEAGATE / WD make)
Supplying installation testing and commissioning of Power Supply SMPS Based 12V For 16 Camera (PROTEK make)
Supplying, including Installation , Testing , Commissioning & Programming of 32 " LCD Display as per Technical specification Screen Size : 32" (80 cm) diagonal ; Viewing Angle 178 degree , Contrast (Dynamic) 2,000,000:1 ; Resolution Full-HD 1,920 x 1,080 (16:9) ; Moving Picture Resolution 800 lines ; 100 Hz Motion Picture Pro ; PC Input Mini D-sub 15-pin
Supplying installation testing and commissioning of UPS 1 KVA for Back Up (ball / ELNOVA / APC make)
Supplying installation testing of UTP CAT6 without PVC conduit
Supply and fixing of 25 mm dia 1.50mm to 2.00mm average wall thickness heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) on surface system including painting etc as required:
Supply and fixing 32 mm mm dia 2.00mm average wall thickness heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) on surface system including painting etc as required:
Gotham (or equivalent as approved by the Deptt.) Supplying installation, testing, programming and commissioning of Audio equipment, High flexible Speaker cable for power amplifiers up to 4000 watts , Jacket - PVC, ø 0.37 in, black ,Conductor resistance = < 1.42 Ohm /1000 ft , Conductor - Stranded bare copper cables, 25x38 AWG (24AW
Supplying including fitting and fixing of lamp holder for 150W/ 250W/ 400W high intensity discharge lamps complete as directed and specified by the deptt. (Philips/Havells/Bajaj)
Supplying including fitting and fixing of the following 240V condenser for HPSV/ MH high intensity discharge lamps complete as directed and specified by the deptt. (Philips/Havells/Bajaj) 42 mfd for 400 W
Supplying including fitting and fixing of the following HID/Son/Son T plus/MHN-TD/MH lamps complete as directed and specified by the deptt. (Philips/Havells/Bajaj make) MH 400 W
Supplying including fitting and fixing of the following Ballast for high intensity discharge lamps complete as directed and specified by the deptt. (Philips/Havells/Bajaj make) BSN 400 X 261 for SON/HPI/ T Plus 400 W
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 2 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 3 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. "With 4x 6 sq. mm. + earth continuity with 2x4 sq. mm. cable in 32 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. "
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Supplying including installation of socket outlet 10/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting and fixing of 6/10 amp one way modular clip in switch with LED , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including fitting and fixing of TV SOCKET, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting and fixing of RJ-11 Telephone jack , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including fitting and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department. 1-2 module type Metal
Supplying including fitting and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department. 3 module type Metal
Supplying including fitting and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department. 6-8 module type Metal
Supplying including fitting and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department. 12-16 module type Metal
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof (IP-43) double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. (ABB, Schneider MG, legrand, Hager, Crabtree xpro make) 6 way TPN (4+18) double door
Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hager, Crabtree xpro make) 6 to 32
Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hager, Crabtree xpro make) 63A
Supplying with fitting and fixing of electric storage water heater [Geyser] of VENUS/RAMSON/RACOLD/V Guard/ HAIER/ Havells or equivalent make including necessary connection etc. as required complete and as directed by the Department. 25 Litre Capacity
Supplying including fitting and fixing of following star rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable, as approved and as directed by the Department [ without regulator]. (ORIENT PSPO make / Usha make/ CROMPTON make/ Havells/ ATC/ V GAURD make)Energy efficient 5-star 1200 mm sweep Fusion 5 star (Havells or equivalent make)
Supplying including fitting and fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt. as required complete and as directed by the Department.Domestic Power Flow 225 mm sweep (ORIENT make)
Supplying including installation of the Octagonal poles shall be designed to withstand the maximum wind speed of 169 km/hr. The top loading i.e. area and weight of fixtures are to be considered to calculate maximum deflection of the poles and the same shall meet the requirement of BS:5649 Part VI 1982. The pole shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding of the pole shaft. The welding of the pole shaft shall be done by Submerged Welding process. All octagonal pole shafts shall be provided with the rigid flange plate of suitable thickness with provision for fixing 4 foundation bolts. The base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside. The welding shall be done as per process approved by Third Party Inspection agency. (BAJAJ/ PHILIPS/ VALMONT/ PARUTHI ENGR/Nezone make) "Pole Type BOP or equivalent-9030 Height 9m The materials of the pole as follows : Conforming to grade S355JO, Base Plate :- Fe 410 Conforming to IS 226/ IS 2062, Foundation Bolts:- 6.8 Gr. As per IS 1367, Pole Sections:- The Octagonal Poles shall be in single piece with single longitudinal welding join, Galvanization :- The poles shall be hot dip galvanized as per IS 2629 / IS 2633 / IS 4759 standards with average coating thickness of 65 micron. The galvanizing shall be done in single dipping. Door opening:- The Octagonal poles shall have door of approximate 500 mm length at the elevation of 500 mm from the base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connection as approved by the Depts.. The door shall be flush with the exterior surface and shall have suitable locking arrangement. The pole shall be adequately strengthened at the location of the door compensate for the loss in section. There shall also be suitable arrangement for the purpose of earthing, Smart pack Junction box with 6 MCB & Terminals for mounting inside base compartment of Pole. Top Dia. :-70, Bottom Dia.:- 155 , Sheet Thickness :- 3mm , Base Plate Dimensions :- (L x B x T) 260 x 260 x 16, Foundation Bolt Size :- (no. x dia.) 4 x 24 Dia, Pitch Circle Dia.:- PC 250 Bolt Length:- 750, Projected Bolt Length :-125 Anchor plate thickness :- 4 mm , Pole Foundation :- The octagonal poles shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. Foundation:- The foundation shall be done with ( Earth work 2.04 cubic Meters.RCC 1:1.5 : 3 proportion 0.65 cubic metres. Steel 22.43 Kg). Shuttering 4.32 square metres. = 22.43 Kg)."
Supplying, installation, testing and Commission of the following indoor Decorative Recess mounted LED down lighter luminaries of model no-LESP01R009XC / LESP01R009XN /LESP01R009XW / L00957R000 / L00940R000 / L00930R000 /LD90-111 - XXX-65-XX complete with all accessories such as ballast, starter etc. In the false ceiling type Armstrong /Gypsum or similar ceiling mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department ( Jaquar / LT / Wipro make).
Supplying, installation, testing and Commission of the following indoor Decorative Recess mounted LED down lighter luminaries of model no-DN 393 B LED 12 S-6500 PSU WH / D01257R000 / D01240R000 / D01230R000 / CRDL11R017HP57 complete with all accessories such as ballast, starter etc. In the false ceiling type Armstrong /Gypsum or similar ceiling mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department ( Jaquar / LT / Wipro make).
Supplying,installation,testing and commissioning of the following integral flood lighting luminaires conforming to IP 65 / IP 66 suitable for vertical and horizontal mounting applications pressure die cast powder coated aluminium alloy housing with corrosion resistance powder coating using nano Technology transparent injection moulded poly carbonate UV stabilized diffuser having high impact strength to withstand min IK09 with high power LED and unique flood optics to ensure uniform light distribution and maintenance free system ideal for area lighting, high mast lighting, sports lighting and billboard. The luminaires should be equiped with external surge protection device to withstand 10 KV / 5KV including connection with 2.5 sqmm 3 core PVC insulated round copper conductor as required and as directed by the department. BVP 410 LED 250 CW HE NB FG S4 XTFCL
Supplying fitting & fixing of LED Kubik Batten tube light fitting 300mm length as required and as directed by the department ( Jaquar or eqvt. make). kubik Series Batten tube fitting 20W
Supply, Erection,Testing and Commissioning of AHRI certified Aircooled Screw Chiller having semi hermetically sealed twin screw type horizontal compressor using R134A refrigerant. The rotors shall be machined to close tolerance for high efficiency and low energy consumption. The compressor shall have automatic capacity control from 25% to 100% making suitable for varying load applications. The control center shall be provided with an advanced microprocessor based control panel. This shall be a part of the factory assembled chiller which shall be installed in separate weather proof panel and shall be unit mounted. The panel shall have a soft touch keypad which can be used for setting / altering the unit set points / control commands. The chiller shal be AHRI certified.The evaporator shall in accordance with ASME certified and (U) stamped. Capacity not less than 178 TR (Daikin/ Carrier/ LG Electronics /Bluestar/ Voltas Make )
Chilled Water Pump Servicing and repairing of end suction back pull out pump split casing pump and TEFC induction motor including supply of spares capacity 95.4CMH
400sq mm 3 Core armoured 11 KV H.T. U.G. cable laid through 150mm dia hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.)
Supply, installation & testing of Copper Plate earth station with 600 mmx600 mmx6 mm heavy duty copper earth plate with necessary 40 mm dia. G.I. medium duty watering pipe with G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm C.I. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Extra for using salt 5 Kg and Charcoal 96 Kg in G.I./Copper plate Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deptt .
Supplying & laying of 25x4 mm size Copper strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of Brass nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
Misclenious woks for site preparation including dismantling the Old Chiller unit and shifting to the storage as required within the Sarusajai Sports Complex, Sarusajai.
Modification of AHU unit
Repairing / Modification of Ducting work
Comprehensive & Preventive Annual Maintenance contract with operational Staff for the First year Necessary Training for operation is to be provided to the operating staffs of Sports Authority of Assam as designated by the Authority.
Comprehensive & Preventive Annual Maintenance contract with operational Staff for the Second year
Comprehensive & Preventive Annual Maintenance contract with operational Staff for the Third year.
Comprehensive & Preventive Annual Maintenance contract with operational Staff for the Fourth year.
Comprehensive & Preventive Annual Maintenance contract with operational Staff for the Fifth year.
Repairing of Heat Pump Unit of capacity 108 kW ( Astra Pool Make) and cooling capacity 72 kW. Scope of work : (i)Repairing / Replacement Compressor Units (ii) Repairing & Replacement of Control Circuit Units for each of the Compressor Unit. (iii) Repairing of Electrical Switchgear attached to the Compressor unit including all accessories (iv) Remodelling as per technical requirement along with plumbing / civil works as necessary (v) Testing & Re-commissioning of the Plant (vi) Comprehensive & Preventive Maintenance contract with operational Staff for 2 (two) years from the Re-Commissioning of the plant with man power as well as running the plant during any event. Necessary Training for operation is to be provided to the operating staffs of Sports Authority of Assam as designated by the Authority.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .