Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹24.1 L+₹2.1 L (9.44%)Rejected-Finance | L2 | Rejected-Finance Not being lowest tender | |
| 3 | L3₹25.0 L+₹3.0 L (13.8%)Rejected-Finance | L3 | Rejected-Finance Not being lowest tender | |
| 4 | L4₹25.9 L+₹3.9 L (17.8%)Rejected-Finance | L4 | Rejected-Finance Not being lowest tender |
Tender Value
₹20.7 L
EMD Value
₹41,400
Closing Date
13 Oct 2020, 6:00 pmClosed
GE AF TA GWALIOR
GE AF TA GWALIOR
REPAIR/MAINT OF INTERNAL ELECTRIC FITTING AND FIXTURE OF EAST WING OF RUNWAY IN TECH AREA AT AF STN GWALIOR
2020_MES_377794_1
8900/1264/GWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF TA GWALIOR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF TA GWALIOR
₹41,400
Yes
21 Nov 2020
15 Sept 2020
17 Oct 2020
15 Sept 2020
13 Oct 2020
29 Sept 2020
Amount
Taking down carefully existing unserviceable aluminum/copper point wiring of any description & in any position with and including existing wooden battens/conduits fixed on surface or concealed and all fittings including sunken/surface boxes & terminal boxes of any description, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings, lamp holders etc including sunken boxes / junction boxes and making good the disturbed surface of walls, floors, ceiling etc. to match with the existing surfaces complete all as specified and directed.
M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits),with multi stranded copper conductor 1.5 sq mm nominal cross sectional area, single core, pvc insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No in and including medium grade, PVC Concealed conduit of dia not less than 20mm and conduit accessories concealed in wall, ISI marked with valid CML No (IS-9537-1983 for conduits and IS: 3419:1976 for conduit accessories), with mild steel/pressed steel sunken boxes (with earth duly) duly painted with two coats of anticorrosive paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3mm thick hylam laminated sheet cover for fixing of switches, sockets etc including PVC insulated multi stranded copper conductor 1.5 sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dully complete all as specified and directed at site for the following : NOTE :- (i) Quoted rate shall be deemed to include the cost of cutting chases in walls / pillars /column etc. of any description for concealing the conduit to required depth & making good the disturbed surface in CM 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at ceiling shall be in surface PVC conduit/ casing & caping of suitable size fixed on ceiling surface with using PVC rawl plugs. (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'. (iii) The quoted rates shall be deemed to be inclusive for provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable brass screws and cup washers
One light/ Fan point controlled by one way switch.
One 5 Amps switch socket combination on independent board.
One 5 Amps socket on same board with other switches.
Description all as per Srl item No 2 above but, point wiring for one six pin switch socket outlet combination, 15 Amps & 5 Amp (independent) with using 2.5 Sqmm (nominal area) stranded copper conductor and 2.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly Complete all as specified and directed.
M&L for point wiring with stranded copper conductor 1.5. Sqmm 1100 Volts grade FRLS PVC insulated and unsheathed including ISI marked PVC casing capping of required sizes as indicated including all accessories, copper conductor cable 1.5 Sqmm insulated and unsheathed PVC cables as earth wire, trminal boxes closed recossed type. PVC Plastic board all as required as specified and directed for the following :- (Make : Havells/Finolex/Polycab) NOTES : (i) The quoted rates shall be deemed to be inclusive for provision of covering existing sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable brass screws and cup washers. (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A' (iii) Quoted rate shall be deemed to include the cost of making good the disturbed surface in CM 1:4 including finishing the surface to match with the existing surface.
One light/ Fan point controlled by one way switch.
One 5 Amps switch socket combination on independent board.
One 5 Amps socket on same board with other switches.
Description as per Srl item No 5 above but, point wiring for one six pin switch socket outlet combination, 15 Amps & 5Amp (independent) with using 2.5 Sqmm (nominal area) stranded copper conductor complete all as specified and directed.
Supplying & fixing for switch socket outlet combination, five pin, 5 Amps, flush type, 230 volts AC circuit complete all as specified and directed. Make: Anchor/Cona/Havells
Supplying & fixing for socket outlet, five pin 2-1, 5 Amps, flush type, 230 volts AC circuit complete all as specified and directed. Make: Anchor/Cona/Havells
Supplying & fixing for switch socket outlet combination, multipurpose, three pin, 15 Amps & three pin 5 Amps controlled by one switch , flush type, 230 volts AC circuit complete all as specified and directed. Make: Anchor/Cona/Havells
Supplying & fixing for ceiling rose surface bakelite 63.5 x 20 mm, three terminals, complete all as specified and directed. Make: Anchor/Cona/Havels
Supplying & fixing for switch flush type, 5/6 Amps, single pole, one way, 230 volts AC circuit complete all as specified and directed. Make: Anchor/Cona/Havels
S&F in repairs lamp holder insulated body with back plate for battern fittings complete all as specified and directed by Engr-in-charge..
M&L for sub main wiring in repair using two single core PVC insulated, unsheathed FRLS stranded copper conductor cable of size 4 Sqmm 1100 Volts grade drawn in and including surface PVC conduit of dia not less than 20mm/ casing caping with standard accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor all as specified and directed. NOTE: Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
Description as per item No 12 above but cable of size 6 Sqmm with one run of PVC(green colour) insulated , unsheathed, FRLS, stranded copper conductor of size 6 Sqmm as earth continuity conductor all as specified and directed. Note : Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit
M&L for sub main wiring in repair using two single core PVC insulated, unsheathed, FRLS, stranded copper conductor cable of size 6 Sqmm of voltage rating upto and including 1100 Volts drawn in existing conduit along-with one run of PVC (Green colour) insulated , unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor all as specified and directed. Note:- Two run of single core PVC cable with one run of earth conductor shall be measured as one unit
M&L for sub main wiring in repair using two single core PVC insulated, unsheathed FRLS stranded copper conductor cable of size 4 Sqmm of voltage rating upto and including 1100 Volts drawn in existing conduit of dia not less than 20mm with standard accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor all as specified and directed. Note:- Two run of single core PVC cable with one run of earth conductor shall be measured as one unit.
M&L for sub main wiring in repair using four single core PVC insulated, unsheathed FRLS stranded copper conductor cable of size 10 Sqmm of voltage rating upto and including 1100 Volts drawn in recessed PVC conduit of dia not less than 32mm with standard accessories, along-with two run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 10 Sqmm as earth continuity conductor all as specified and directed. NOTE:- Four run of single core PVC cable with two run of earth conductor and conduit shall be measured as one unit.
M&L for sub main wiring in repair using four single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm of voltage rating upto and including 1100 Volts drawn in recessed PVC conduit of dia not less than 32mm with standard accessories, along-with two run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor all as specified and directed. NOTE:- Four run of single core PVC cable with two run of earth conductor and conduit shall be measured as one unit.
Supplying & fixing in repair Stout plus LED is a complete range of industrial LED batten to replace traditional T8 batten.The range is perfact for lighting large areas such as corridor ,warehouses & genral purpose spaces 40watt including all accessories, pre-wired and connecting the same to ceiling rose with & including three core PVC insulated and sheathed copper conductor 1.5 sqmm cable with all accessories and fixing arrangement for fixing the light fitting to walls / roof surface complete all as specified and directed. Make :- Havells Cat No STOUTPLUS1200BS40WLED857SPCWH/BAJAJ /Wipro/CGand eqivalant in other.
Supplying, fixing in repair & testing decorative recess mounting 36 watt LED full out put luminaries suitable for Armstrong ceiling, white powder coated sheet steel housing with paralite P5 square parabolic louver block in metallic perforated frame for low glare, aluminium reflector and accessories,connecting the same to electric source with and including copper conductor 23/0.0076 flexible twisted twin core cable , including all accessories and fixing arrangements for fixing the light fitting to false ceiling complete all as specified and directed. Make :Bajaj cat part No BZRSQL 36W GZ1 NW "SKYLUX' Racess mounted 2x2 LED or equvlent Philips/CG
Supplying, fixing in repair & testing Decorative recessed mounting 15W LED full output Luminaires suitable for Armstrong ceiling, white powder coated pressure die-cast aluminium heat sink & PC diffuser in white powder coated finish with integrated driver, and accessories, connecting the same to electric source with and including copper conductor 23/0.0076 flexible twisted twin core cable , including all accessories and fixing arrangements for fixing the light fitting to false ceiling complete all as specified and directed. Make :Bajaj Cat No:-INTEGRANEODLR15WLED830S of Havells or equivalent in Philips/Oshram
Supply, fixing, connecting & testing sheet metal enclosures double door, single pole and neutral, 4 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating including disconnecting and taking down of old unserviceable distribution board with all fitting and fixture complete all as specified and directed. Make :-Legrand/Havels/L&T
Description same all as per Item No 21 above but, MCB DB suitable for single pole & neutral, 8 way complete all as specified and directed. Make :-Legrand /L&T/Havells
Supply, fixing, connecting & testing of sheet metal enclosures double door, triple pole and neutral, 4 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating including disconnecting and taking down of old unserviceable distribution board with all fitting and fixture complete all as specified and directed. Make :-Legrand/Havells/L&T
Supply and fixing factory made epoxy powder coated distribution board VTP & N 4 ways (TPN MCCB DB) with metal door (IP-54 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one TPN-MCCB 125 Amps as incomer and 12 SP MCBs or 4 TP MCBs (or any combination of SP/TP MCBs ) outgoings including disconnecting and taking down of old unserviceable distribution board with all fitting and fixture complete all as specified and directed. Make :- Legrand/Havells/L&T
Supply and fixing factory made epoxy powder coated distribution board VTP & N 8 ways (TPN MCCB DB) with metal door (IP-54 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one TP-MCCB 125 Amps as incomer and 12 SP MCBs or 4 TP MCBs (or any combination of SP/TP MCBs ) outgoings including disconnecting and taking down of old unserviceable distribution board with all fitting and fixture complete all as specified and directed. Make :- Legrand/Havels/L&T
S&F MCB TPN, 63 Amps four pole (`C’ series) having bracking capacity 10 KA complete all as specified and directed. Make :- Legrand/Havels/L&T
S&F MCB SPN, 32 Amps (`C’ series) having bracking capacity 10 KA complete all as specified and directed. Make :- Legrand/Havels/L&T
S&F MCB single pole, 6 to 32 Amps (`C’ series) having bracking capacity10 KA complete all as specified and directed. Make :- Legrand/Havels/L&T
S&F fan regulator electronic, step type, suitable for ceiling fans of any capacity, pre-wired 230 volts AC 50Hz supply 100Watt complete all as specified and directed. Make: Anchor/Cona/Havels
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed by Engineer-in-Charge. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
Supplying & fixing earth continuity conductor or main earthing lead fixed to walls or to poles or any other indicated situation for loop earthing with using 4mm dia GI earth wire complete all as specified and directed
Disconnecting , taking down & removing carefully the existing ceiling fan, exhaust fans, wall bracket fans and air circulating fans etc , of any description, any sweep and from any position / locations (i.e.Technical Area's OTM Accn / hangers),sealing cable end, for repairs / servicing / overhauling / painting / numbering etc and hanging / fixing the repaired fans in position after , dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing , fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades,connecting to existing electric sources and testing at site to the entire satisfaction of Engineer-in-Charge complete all as specified and directed. Note: - (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item. (ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding. (iii) The rates for above items are deemed to include for transportation of fans to & from workshop if required and approved by the Engineer-in-charge for necessary repairs. (iv) Remetaling of motor shaft, polishing and grinding and making to standard size to matching with GM Bush shall be measured and paid for separately under appropriate item of Sch ‘A’ (v) Writing of fan No. and painting of fans shall be measured and paid for separately under appropriate item of Sch ‘A’ (vi) Repair cost shall not be BER in any case. (vii) Inventory shall be prepared for defective parts/items and shall be signed by Engineer-in-charge and Contractor.
M&L rewinding of same with super enamelled copper wire of suitable existing size/gauge including insulating material and varnishing including testing to the satisfaction and all as directed by Engineer -in- Charge for the following type of fans :-
Ceiling fan 1200 / 1400 mm sweep any make.
Exhaust fan 300 mm / 225 mm sweep any make.
Exhaust fan 375 / 450 mm sweep any make.
Wall/Cabin fan 450 mm sweep any make.
Pedestal fan 400 mm sweep any make.
Air circulating fan of 610 mm sweep any make.
Flame proof Exhaust fan 300/400 mm sweep any make.
Supply only the following spare for replacement in fan complete all as specified and directed.
Bush for the ceiling fan of any make and sweep.
Ball bearing for ceiling fan/wall fan/pedestal fan/exhaust fan & Cabin fan Make : NBC/SKF
Rubber reel.
Split pin
Condenser 2.5 MFD Make : Siemens/EPCOS/Usha
-do- but 3.15 MFD
-do- but 4 MFD
Canopy for ceiling fan (set of 02) as per sample. Make : Khaitan/Crompton/Bajaj/Usha
Regulator resistor type suitable for wall fan Make : Khaitan/Crompton/Usha.
-do- but for pedestal fan
MS clips (set of two) as per sample of ceiling fan
M&L for servicing of in position /of taking down i.e.requried ceiling fan/exhaust fan/cabin fan (any make any size) from any building and opening the same cleaning each part, oiling and greasing including replacement of worn out parts i.e nut, bolt, screw, split pin, rubber real complete and re-fixing in the same position after repair to the entire satisfaction and as directed by Engineer -in- Charge.
M&L for painting of ceiling fan including fan blade of any make of any size with one coat of synthetic enamelled paint after scraping old paint and preparing surface for painting including one coat of red oxide primer and rewriting existing MES number with black paint complete to the entire satisfaction and as directed by Engineer -in- Charge.
-Ditto- all as per item No 5 above but exhaust fan/Air circulator fan.
Supply and fixing down rod for ceiling fan made of GI pipe 15mm dia medium grade of length 0.3 to 01 meter or as required including threading, cutting slotting drilling including nut, bolt clip washer and rubber real.
S&F wall /pedestal fan blade of any sweep/any size as per sample all as directed by Engineer-in-charge.
S&F Exhaust fan blade of any sweep/any size as per sample all as directed by Engineer-in-charge.
S&F Exhaust fan clamp (leg) as per sample (set of 3/4) including rubber packing and clamp for bolt all as directed by Engineer-in-Charge.
Taking down UNSV Geysers of any size and make from wall by disconnecting and sealing water line and electrical connection for annual painting/maintenance/servicing/overhauling/dismantling of various parts for repair/replacement/painting including carryout brazing to inner tank etc, re-assembling after repair and replacement of worn parts
S & F GM non-return valve, 15 mm bore. ISI mark.
S & F lead cum brass alloy pipe for inlet & outlet connection 15 mm bore 450 long including check/end nuts and washer to prevent water leakage all as specified and directed.
S & F PVC pipe steel thread armoured for inlet and outlet connection, 15 mm bore 450 long all as specified and directed.
S & F vent pipe connection of 15 mm bore, light grade, GI Pipe of required length including necessary fittings complete all as specified and directed.
S & F heating element of any type, ISI marked (2.0 KW) for 50 ltrs capacity geyser all as specified and directed.
S & F heating element of any type, ISI marked (1.5 KW) for 25 Ltrs capacity Geyser all as specified and directed.
S & F thermostat for 50/35/25 ltrs capacity Geyser of any type and make as per sample ISI marked all as specified and directed.
S & F pressure release valve 15 mm dia suitable for 50/35/25 ltrs Geysers of any make. ISI marked all as specified and directed.
S & F syphone assembly complete with packing ring and nuts and bolts suitable for 50 ltrs capacity of Geysers of any make including testing against leakage all as specified and directed.
S & F syphone assembly complete with packing ring and nuts and bolts suitable for 25 ltrs capacity of Geysers of any make including testing against leakage all as specified and directed.
S & F PVC insulated copper conductor cable multi stranded 3 core 4 Sqmm flexible all as specified and directed.
S & F fusible plug made of brass having lead alloy fuse suitable for 50/35/25 ltrs capacity Geyser of any make all as specified and directed.
S & F Inner copper tank for having 50 ltrs capacity Geyser of any make all as specified and directed.
S & F Inner copper tank for having 25 ltrs capacity Geyser of any make all as specified and directed.
S & F outer tank for having 50 ltrs capacity Geyser of any make all as specified and directed.
S & F outer tank for having 25 ltrs capacity Geyser of any make all as specified and directed.
SWAMI CONSTRUCTION
M/S Rakesh Verma
Om Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .