Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.6 LAccepted-Finance 7A BENTINCK STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | ₹26.6 L | L1 | Accepted-Finance Lowst bidder |
| 2 | L2₹27.1 LRejected-Finance 14 BEPIN BEHARI GANGUALY STREET KOLKATA 700 012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | ₹27.1 L | L2 | Rejected-Finance High rate offered |
| 3 | L3₹27.2 LRejected-Finance BASUDEBPUR BELKHALI HOWRAH PIN 711 322 | HOWRAH | HOWRAH | WEST BENGAL | 711322 | ₹27.2 L | L3 | Rejected-Finance High rate offered |
| 4 | Rejected-Technical 12 1 FERRIGHAT ROAD P O BHATPARA DIST NORTH 24 PGS WEST BENGAL PIN 743123 | BHATPARA | NORTH 24 PARGANAS | WEST BENGAL | 743123 | - | - | Rejected-Technical technically reject |
| Sl No | Description | Qty | Unit | PERFECT IMAGE SOLUTIONS L1 | ASSOCIATED ELECTRICAL CONST CO. 1963 PVT.LTD L2 | Computer Gallery L3 |
|---|---|---|---|---|---|---|
| 1.01Day to day preventive & corrective maintenance of the entire Fire Detection system installed at different buildings within the premises of NRSMC & Hospital and it's Annex Hospitals by engaging 1 no. skilled and 2 nos. Semi-skilled person in morning & evening shift, 1 no. skilled and 1 nos. Semi-skilled person in night shift having adequate knowledge & skill in fire detection system and Graphic Software Integration as per terms & condition. Skilled person (3x12=36 person) Semi skilled person (5x12=60 person) | ||||||
| 1.02 | Skilled Persons(3 nos operator/day/month x12 months=36 person) | 36 | Permonth/per shift/operator | 21,400 ₹7,70,400 | 21,500 ₹7,74,000 | 21,600 ₹7,77,600 |
| 1.03 | Semi-skilled Persons(5 nos operator/day/month x12 months=60 person) | 60 | Permonth/per shift/operator | 19,450 ₹11,67,000 | 19,800 ₹11,88,000 | 19,800 ₹11,88,000 |
| 2.00Replacement cost for following supply & installation of spare parts (Consumable spares & Emergency spares) as and when required for annual preventive and corrective maintenance of Fire Detection System. | ||||||
| 2.01 | Supply, Installation, Testing & Commissioning analog Addressable Intelligent multi sensor detector (VDS/UL/FM/ULC aproved) with inbuilt optical smok sensors as well as additional heat detector sensor with decentralise intelligence, soft addressable photo thermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per recommended standard (Make: Esser) | 120 | Nos | 2,380 ₹2,85,600 | 2,450 ₹2,94,000 | 2,500 ₹3,00,000 |
| 2.02 | Supply, Installation, Testing & Commissioning Addressable Heat Detector (Fixed temperature cum rate of rise) ( VDS / UL / FM / ULC approved ) with twist lockable removal base, built - in fault isolator, drift compensation feature etc including connections as per specifications complete as reqd and having IP as per recommended standard (Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost). (Make: Esser) | 8 | Nos | 2,200 ₹17,600 | 2,275 ₹18,200 | 2,300 ₹18,400 |
| 2.03 | Supply, Installation, Testing & Commissioning Addressable Loop Powered Hooter (sound output of minimum 90 db ) cum strobe (strength of light 10 cd)complete with inbuilt isolator & IP65 base and ( VDS / UL / FM / ULC approved) approved. (Make: Esser) | 10 | Nos | 8,900 ₹89,000 | 9,100 ₹91,000 | 9,350 ₹93,500 |
| 2.04 | Supply, Installation, Testing & Commissioning of Addressable Operating front w. SZI 64, GB, as per NFPA style 7 wiring complete as required. (Make: Esser) | 2 | Nos | 45,300 ₹90,600 | 45,700 ₹91,400 | 45,300 ₹90,600 |
| 2.05 | Supply, Installation, Testing & CommissioningAddressable Manual Call Point (VDS / UL / FM / ULC approved) soft addressable type within built fault isolator as per NFPA style 7 wiring complete as required. (Make: Esser) | 15 | Nos | 3,400 ₹51,000 | 3,500 ₹52,500 | 3,700 ₹55,500 |
| 2.06 | Supplying, installation, testing and commissioning of LED type Response Indicator (VDS / UL / FM / ULC approved) having 2 Nos. red coloured LED lamps including connections etc. (Make: Esser) | 15 | Nos | 100 ₹1,500 | 105 ₹1,575 | 100 ₹1,500 |
Tender Value
Refer Docs
EMD Value
₹53,238
Closing Date
16 Dec 2025, 3:00 pmClosed
EE II CKHED
P12 CIT Road 1st floor Kol 14
Annual comprehensive maintenance of Fire Detection and Alarm System installed at different building in the campus of at NRS Medical College and Hospital, Kolkata 700014
2025_WBPWD_954545_1
WBPWD/EE-II/ CKHED/ENIT-69/25-26
Open Tender
ELECTRICAL WORKS ORG
365 days
NRS MCH
As per NIT
4 documents required · 4 mandatory
₹53,238
central kolkata health electrical division
8 Jan 2026
20 Nov 2025
19 Dec 2025
20 Nov 2025
16 Dec 2025
26 Nov 2025
25 Nov 2025
Amount
Day to day preventive & corrective maintenance of the entire Fire Detection system installed at different buildings within the premises of NRSMC & Hospital and it's Annex Hospitals by engaging 1 no. skilled and 2 nos. Semi-skilled person in morning & evening shift, 1 no. skilled and 1 nos. Semi-skilled person in night shift having adequate knowledge & skill in fire detection system and Graphic Software Integration as per terms & condition. Skilled person (3x12=36 person) Semi skilled person (5x12=60 person)
Skilled Persons(3 nos operator/day/month x12 months=36 person)
Semi-skilled Persons(5 nos operator/day/month x12 months=60 person)
Replacement cost for following supply & installation of spare parts (Consumable spares & Emergency spares) as and when required for annual preventive and corrective maintenance of Fire Detection System.
Supply, Installation, Testing & Commissioning analog Addressable Intelligent multi sensor detector (VDS/UL/FM/ULC aproved) with inbuilt optical smok sensors as well as additional heat detector sensor with decentralise intelligence, soft addressable photo thermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per recommended standard (Make: Esser)
Supply, Installation, Testing & Commissioning Addressable Heat Detector (Fixed temperature cum rate of rise) ( VDS / UL / FM / ULC approved ) with twist lockable removal base, built - in fault isolator, drift compensation feature etc including connections as per specifications complete as reqd and having IP as per recommended standard (Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost). (Make: Esser)
Supply, Installation, Testing & Commissioning Addressable Loop Powered Hooter (sound output of minimum 90 db ) cum strobe (strength of light 10 cd)complete with inbuilt isolator & IP65 base and ( VDS / UL / FM / ULC approved) approved. (Make: Esser)
Supply, Installation, Testing & Commissioning of Addressable Operating front w. SZI 64, GB, as per NFPA style 7 wiring complete as required. (Make: Esser)
Supply, Installation, Testing & CommissioningAddressable Manual Call Point (VDS / UL / FM / ULC approved) soft addressable type within built fault isolator as per NFPA style 7 wiring complete as required. (Make: Esser)
Supplying, installation, testing and commissioning of LED type Response Indicator (VDS / UL / FM / ULC approved) having 2 Nos. red coloured LED lamps including connections etc. (Make: Esser)
Supply, Installation, Testing & Commissioning of LED type relay Modules (VDS / UL / FM / ULC approved)
S&F of MCP Glass in place of damaged one.
12Volt,12AH SMF, Make - Exide/Amaron
Supply & Laying of 2 core 1.5 sq.mm FRLS shiethed copper cable (for loop)(make: Finolex/RR Kable/Polycab/glo star) with PVC conduit ( Make - Precesion)
Supply & Laying of 2 core 2.0 sq.mm FRLS shiethed Armoured copper cable for Graphic Software Integration amoung CB Bldg.,Baker Bldg and OPD Bldg.(make: Finolex/RR Kable/Polycab)
Rate should be quoted incl. of all taxes and cess.
Defect Liability period : 1 year
ASSOCIATED ELECTRICAL CONST CO. 1963 PVT.LTD (BID ID -7591319)
Computer Gallery (BID ID -7622629)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.43 MB
terms_and_condition.pdf
Additional Documents • 0.12 MB
revised2911.pdf
Tender Documents • 0.50 MB
BOQ_2288079.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid