Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC | ₹1.4 Cr | L1 | Accepted-AOC Being Lowest and found reasonable |
| 2 | L2₹1.4 Cr+₹4.2 L (3.06%)Rejected-Finance | ₹1.4 Cr+₹4.2 L (3.06%) | L2 | Rejected-Finance Not Being Lowest |
| 3 | L3₹1.4 Cr+₹5.1 L (3.73%)Rejected-Finance | ₹1.4 Cr+₹5.1 L (3.73%) | L3 | Rejected-Finance Not Being Lowest |
| 4 | L4₹1.5 Cr+₹10.1 L (7.32%)Rejected-Finance | ₹1.5 Cr+₹10.1 L (7.32%) | L4 | Rejected-Finance Not Being Lowest |
| 5 | L5₹1.5 Cr+₹11.2 L (8.17%)Rejected-Finance | ₹1.5 Cr+₹11.2 L (8.17%) | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹1.6 Cr
EMD Value
₹2.3 L
Closing Date
11 May 2024, 6:00 pmClosed
CHIEF ENGR BHOPAL ZONE
HQ CHIEF ENGR BHOPAL ZONE, MES SI LINE BHOPAL 462001
PROVN OF SUMP OF CAPACITY 80000 GALLONS PUMP HOUSE AND ALLIED SERVICES AT ADMIN AREA ITARSI
2024_MES_646124_1
CA NO. CEBZ / ITA / TOKEN / 11 OF 2023-24
Open Tender
Civil Works - Others
Lump-sum
365 days
Itarsi
Please refer tender documents
4 documents required · 4 mandatory
₹1,000
GE BHOPAL
₹2.3 L
BHOPAL
31 May 2024
12 Mar 2024
13 May 2024
12 Mar 2024
11 May 2024
27 Apr 2024
22 Mar 2024
Amount
Note:-Please refer schedule 'A' notes before quoting the tender.
GENERAL SUMMARY
Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule ‘A’ Part- I (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part- II (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part- III (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part- IV (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for EXTERNAL ELETRIC SUPPLY WORKS as listed in Schedule ‘A’ Part- V (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for ROAD / PATH / CULVERT WORKS as listed in Schedule ‘A’ Part- VI (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’ Part- VII (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for COMPOUND WALL, FENCING & GATE WORK as listed in Schedule ‘A’ Part-VIII (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for UG SUMP 80000 GALLON as listed in Schedule ‘A’ Part- IX (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for EXCAVATION, EARTH WORK AND SITE DEVELOPMENT WORKS as listed in Schedule ‘A’ Part-X (Ref prepriced schedule attached seperately)
SCH 'A' Pt - XI (MISCELLANEOUS ITEMS) (Contains Ser item No 4.00 to Ser item No 8.06)
INTERNAL ELETRIFICATION WORKS NOTE:- For items of internal Electrifications notes given at the beginning of Sch ‘A’ Part-III (internal Electrification) shall also be applicable.
Material and Labour for Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with 1.5sq mm nominal cross sectional area PVC insulated unsheathed multi-stranded FRLSH copper conductor 1100 volts grade, drawn in and including medium grade, rigid PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), and including modular metal flush boxes with modular frame plate and white cover for housing switch, sockets, regulators, etc including 1.5 Sq mm nominal cross sectional area PVC insulated unsheathed multi-stranded FRLSH copper conductor cable as earth continuity conductor to common earth dolly complete all as specified and directed for the following:- NOTE:- The quoted unit rate is deemed to be inclusive of cost of metal flush boxes, modular white cover plates, modular frame plates, etc.
One light point controlled by one 5/6 amps one way modular switch.
One ceiling /exhaust fan point controlled by one modular switch and regulator.
One Socket outlet, three/five pin, 5 Amp, controlled by one 5/6 amps one way modular switch or modular switch/socket combination 5 amps, 5 pin on the same board with other switches, sockets, fan regulators, etc.
Material and Labour for Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with 2.5 sq mm nominal cross sectional area PVC insulated unsheathed multi-stranded FRLSH copper conductor 1100 volts grade, drawn in and including 20mm dia medium grade, rigid PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), and including provisions of modular metal flush boxes with modular frame plate and white cover for housing switch, sockets, regulators, etc including 2.5 Sq mm nominal cross sectional area PVC insulated unsheathed multi-stranded FRLSH copper conductor cable as earth continuity conductor to common earth dolly for one 3/5 pin 15/16 Amps socket outlet point on independent board complete all as specified and directed for the following:- NOTE:- The quoted unit rate is deemed to be inclusive of cost of metal flush boxes, modular white cover plates, modular frame plates, etc.
S&F LED lamp 9W, 230V AC, 50Hz single phase with & including two pin bakelite batten holder B-22 type pvc / polycrbonate type with back plate with all fitting fixing accessories on wall complete all as specified and directed.
S & F LED Security light fitting 36 Watt, system lumen efficacy of LED not less than 120 lumen/W, PF> 0.95, THD < 10%, colour temprature 6000 to 6500K, CRI > 70, system lumen not less then 4320 Lm, made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens with toughed glass having bottom separate driver compartment with IP 66 Protection and Impact resistant of IK 07 etc and all accessories previewed complete including mounting bracket of 40 mm inner dia light grade of required length and shape incl bending, forging or welding etc and suitable bolts and nuts with washers, including connecting with PVC insulated multi stranded copper flexible cable of size 0.5 sqmm three core from ceiling rose to fitting complete all as specified and directed by Engr-in-Charge.
EXTERNAL WATER SUPPLY WORKS NOTE:- For items of EXTERNAL WATER SUPPLY notes given at the beginning of Sch ‘A’ Part-IV ( EXTERNAL WATER SUPPLY ) shall also be applicable.
M & L DI pipes Spigot & Scokets including special class K-9 size 100 mm bore , in any length, laid in trenches including all accessories and push on type tyton joint etc complete all as specified and directed.
Supply and fixing of CI 100mm bore Non Return Valves ISI Marked flanged class 1.0 PN with by-pass arrangement and necessary bolts and nuts of suitable size with and including rubber gasket for flanged joints and testing complete all as specifiec & directed
Supply and fixing of Cast Iron Foot Valve of size 100 mm dia, conforming to IS-4038, complete all as specified and directed.
Supply, installation, testing and commissioning of minimum 3-star rated pumping set, centrifugal, multistage pump electric driven not less than 70 Mtr head and 900LPM discharge driven by continuous duty AC induction motor, 2900 RPM, 3 Phase, 415 Volts, 50 Hz, 20 WHP with mounting base and vibration pads and suitable foundation as per manufactures design including connections of pump with suction and delivery end including base plate, coupling, coupling guard and foundation nuts & bolts with CI mounting frame with vibration pads all as specified and directed by Engr-in-Charge.
Supply, fix and commisioing of Chemical Dosing pump plunger type capacity 30 ltr /hr against 15 Kg Back pressure with its all accessories like injection, check valve , Y Strainer, PRV, suction/discharge tubing etc sutiable for chlorine and liquid dosing alongwith 100 Ltr FRP Solution preparation cum settling tank with lid, port hole, inlet/outlet/drain connection, sludge collection facility, level gauge etc and fitted with speed reducing motor and SS-316 agitator (FRP Coated for extra protection) including taking down of exisring dosing pump all as specifed and directed by the Engineer-in-Charge.
Supply and fixing of CI Sluice valves 100mm ISI Marked Flanged class 1.0 PN with necessary bolts and nuts of suitable size with and including rubber gasket for flanged joints & testing complete all as specified and directed.
Supply and fixing of CI Sluice valves 80mm ISI Marked Flanged class 1.0 PN with necessary bolts and nuts of suitable size with and including rubber gasket for flanged joints & testing complete all as specified and directed.
Material and Labour Construction of brick masonary valve pit chamber of internal size 900mm x 900mm x 900mm , 100mm thick PCC 1:4:8 type D2 usinng ( 40mm graded stone aggregate ) lean concrete in foundation , providing old size well burnt clay brick masonary wall of 230mm thick built in Cement Mortar 1:6 , rendering in cement mortar 1:6 finished even and smooth using extra cement internally and 20mm thick in Cement Mortar 1:4 finished fair and even , supply and fix 3.15 mm thick MS sheet steel cover fixed on 50mm x 50mm x 6mm thick angle iron frame , embeded in PCC coping with PCC 1:2:4 type-B1 using 20mm graded stone aggregates , with locking arrangement and 1 No. 50mm size 4 levers lock with key in duplicate Standard size and MS hold fast and handle made out of 25mm x 6mm flat iron and applying two coats of synthetic enamel paint of approved shade over a coat of primer (Red Oxide zinc chromate primer ) to all exposed surface including earth work i.e. excavation, returing filling and removal of any type of soil complete all as specified and as directed and all as shown on drawings No.CEBZ/TD/43/2011 sheet 1/1 Note:- The rate of earth work i.e. excavation, returing filling and removal of any type of soil is included in this item and nothing shall be paid extra on this account.
EXTERNAL ELETRIC SUPPLY WORKS NOTE:- For items of EXTERNAL ELECTRIC SUPPLY notes given at the beginning of Sch ‘A’ Part-V ( EXTERNAL ELETRIC SUPPLY ) shall also be applicable.
Supply, installation, test and commissioning copper wound, step down transformer outdoor type complete with standard fittings, HT, 33 KV, 3 phase, LT, 433 V, 3 Phase, 4 wire with off load tappings on primary side to vary secondary voltage + 7.5% with tapings at every 2.5% rating of capacity 63 KVA. The transformer shall be complete with all standard fitting and accessories, gauges first fill of transformer oil upto appropriate level etc., all as per IS 1180 (Part - I) 2014, energy efficeient level - 2 and all jointing materials connected with elect system earthing etc. complete including platform as per manufacturer design all as specified and directed comprising following accessories:
Contd/- serial item no. 6.01 (a) One cable box HV side consisting of 3 Nos porcelain terminal points including nuts, bolts and washers with two Nos cable gland suitable for 3 core 95 Sqmm HT UG cable. (b) Suitable cable box LV side for mounting two LV cable consisting of 4 Nos porcelain with brass bushing rods, complete with nuts and washers with two nos cable gland suitable for LT UG cable providing with bimettalic lugs. (c) Oil conservator with filler type drain valve and oil level gauge. (d) Dehydrating breather with fast fill of dehydrating agent. (e) Explosion vent. (f) Thermometer pocket on tank cover including thermometer. (g) Rating plate and terminal marking plate. (h) The earthing terminal two Nos to tank to faciliate fixing of earth strip (i) Oil level gauge and Oil drain filter valve. (j) Lifting lugs (k) Oil filling hole with cap/plug with connection plate complete. (l) Air relief valve plug (m) Tap changer (n) Detachable rollers - 04 Nos (o) Four Nos wheels with locking arrangement. (p) Under base channel (q) Additional neutral terminal (r) Cooling fins. (s) OTI with MRP.
Supply, install, testing and commissioning of Automatic Power Factor Correction (APFC) Panel complete with power capacitor bank for power factor improvement, three phase, 440V and 50 HZ system, MD XL type super heavy duty suitable for non liner load upto 25% including conttolling switch fuse TP housed in sheet metal enclosure of size 3.15mm thick CRCA sheet with locking arrangement duly powder coated including copper busbar of requisite capacity, digital KVAR, indicator, volt meter, ammeter, contactor, suitable relays, fuse unit, bush button etc alongwith auto and manual control switch with MCCB of suitable capacity as incommer all as specified of capacity 40 KVAR comprising of the followings:-
S&F in Disc type insulator porcelain vitreous 145mm height and 255 mm dia ball and socket type brown white or green single disc assembly for tension with tension clamps for condutors working pressure 33000 volts all as specified and directed.
S&F Pin type vitreous porcelain white brown or green insulator including one galvanised mild steel spindle two galvanised iron washer and one galvanised iron nut, 150mm height 150mm dia for 33000 volts grade all as specified and directed.
S&F LED Street light filtting 35/36 Watt, system lumen efficacy of LED not less than 120 lumen/watt, THD < 10%, colour temperature 6000 to 6500 K, CRI>70 with PF not less than 0.95, made up of pressure die cast aluminum housing with high efficiency LED as lighting source and lens with toughned glass having bottom sperate driver compartment with IP 66 Protection and Impact resistant of IK 07, etc and all accessories prewired complete with & including mounting bracket of 40 mm bore light grade GI pipe of required length and shape including bending, forging or welding, suitable bolts and nuts with washers complete all as specified and directed.
Supply and fix of pole mounted junction box three phase with in side dimensions not less than 250 x 200 x 105 mm with porcelain connector 2 Nos, colour coaded aluminium bus bar 04 Nos of rating 63 amps each mounted on non cracking epoxy insulators, MCB SP 6 Amps, 250 volts, 'C' curve - 01 Nos. Mounted in including provisioning of mounting arrangements with clamps, nut, bolts, and washer etc for fixing to pole, drilling with proper hole for incoming and outgoing cables connection of suitable size with bus bar complete all as specified and directed. complete all as specified and directed. Note : The rate quoted inculdes cost of MS Clamps, bolts, nuts and washers
Supply, install, testing and commissioning of LT power distribution panel board with CRCA sheet and CPRI approved, outdoor cubicle type, 415 Volts, 50 Hz, free floor mounted front and back openable, made out of 3.15 mm thick cold rolled MS sheet of suitable size to accommodate the following items, vermin proof, dust proof, supported on and including ISMC 75 X 40mm powder coated steel frame and totally powder coated with epoxy siemen grey colour from inside and outside with locking arrangement and fixing arrangement i.e nuts, bolts, washers, clamps etc, with naturally air cooled bus bar 4 strip suitable for 200 Amps with detachable gland plate for incoming and outgoing cable including termination of cable ends both incoming and outgoing with sufficient working space inside including installing, testing and commissioning complete all as specified and as directed consisting of following :-
Supply and fixing cable PVC insulated and PVC sheathed size 1.5 Sqmm three core stranded aluminium conductor from pole junction box to fitting complete all as specified and directed .
Supply, laying, testing and commisioning in replacement of HT underground cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire aromoured electric power cables (heavy duty) with aluminium stranded condutor served with an inner sheathing of PVC tape armoured with galvanized steel strip and overall PVC sheathed 33000 volts grade (earthed) of cross sectional area of size 95 sq mm 3 core complete all as specified and directted by the Engineer-in-Charge.
Supply and fix cable jointing kit for 33 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 Sqmm all as specified and directed by the Engineer-in-Charge.
M&L for earthing complete with galvanized steel earth plate electrode size 600 x 600 x 6 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized steel and GI pipe medium grade 20 mm dia bore for watering funnel with wire mesh, 15 mm dia GI pipe light grade for earthing electrode protection, CI cover with frame, PCC chamber pit with PCC (1:3:6 ) type C- 1, 40 mm thick precast RCC M-25 (Design Mix) cover reinforce with 8 mm dia TMT bars @ 10 cm c/c both ways and lifting handle, excavation and earth work all as shown in electrical plate No 3 of SSR Part-I (2009) connected to earthing test (Contd..)
Contd/- serial item no. 6.15 (Description continue from last item) point all as specified or indicated including testing on completion.Note:- (i). Excavation, returning filling and removing of surplus soil is deemed to be included in the unit rate. (ii) Cost of PCC pit, RCC Pit cover with funnel & wire mesh, water pipe, test point is demmed to be included in the unit rate in addition to Item No.1(a) to 1(e) of premeable (Notes) under sub-heading earthing, specified in SSR Part-II. (iii) The unit rate also includes the cost of GI earth lead and GI pipe for protection of earth strip up to 7.5 metre (any variation in length shall be adjusted through deviation order). NOTE - out of 05 earthing, 01 no. earthing is to be provided for Internal Electrification.
M&L for earthing complete with galvanized steel earth plate electrode size 600 x 600 x 6 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized iron strip 32X6 mm earth lead by means of bolts, nuts, check nuts and washers of galvanized steel and GI pipe medium grade 20 mm dia bore for watering funnel with wire mesh. CI cover with frame, 40 mm dia GI pipe light grade for earthing electrode protection, PCC chamber pit with PCC (1:3:6 ) type C- 1, 40 mm thick precast RCC M-25 (Design Mix) cover reinforce with 8 mm dia TMT bars @ 10 cm c/c both ways and lifting handle, excavation and earth work all as shown in electrical plate No 3 of SSR Part-I (2009) connected to earthing test point all as specified or indicated including testing on completion. Note:- (i). Excavation, returning filling and removing of surplus soil is deemed to be included in the unit rate. (ii) Cost of PCC pit, RCC Pit cover with funnel & wire mesh, water pipe, test point is demmed to be included in the unit rate in addition to Item No.1(a) to 1(e) of premeable (Notes) under sub-heading earthing, specified in SSR Part-II. No.1(a) to 1(e) of premeable (Notes) under sub-heading earthing, specified in SSR Part-II. (cont...)
Contd/- serial item no. 6.17 (iii) The unit rate also includes the cost of GI earth lead and GI pipe for protection of earth strip up to 7.5 metre (any variation in length shall be adjusted through deviation order).
Supply, installation, commisioning and testing of Diesel Engine driven generating set 62.5 KVA, 50 KW, 415 Volts, 3 phase 4 wire, engine complete with integral acoustic enclosures as per latest Indian Standards of central pollution control board and as alternator with relay,Control panel, sound proof canopy and PCC foundation of required size for DG set as per manufacturer's instructions complete including the following :- A. ENGINE :- (i) 3 Cylinder, In-line 4 stroke. (ii) Turbocharged and intercooled cooling system (iii) Stainless steel exhaust flexible coupling and exhaust pipe (iv) Radiator water cooled (v) Coolant inhabitor (vi) Plate type lubricant oil cooler (vii) Spin-on filters coolant, fuel & lubricant oil. (viii) Dry type heavy duty replaceable paper element air cleaner with restriction indicator. (ix) Electronic governor (x) Electric starting system (xi) Battery charging alternator. (xii) 12 volts 88 AH/suitable as company design maintanence free battery with multi standared copper cable for connecting wire and terminal complete (xiii) First fill lub oil. (contd...)
Contd/- serial item no. 6.19 B. ALTERNATOR :- (i) 4 P rotating field , 415V , 50 HZ . Brushless type (ii) Voltage regulation plus/minus/+1 percent. (iii) IP- 23 protection with Class 'H' insulation (iv) Flex disc type cupling (v) Automatic voltage regulator. (vi) Noise level 75 dBA @ /meter (vii) Telephone interference factor .50 (viii) Total harmonic factor better than 2% (ix) Supplying power to variable electrical load for unlimited hours. Prime power (PRP) is in accordance with ISO 8523. 10% overload capacity for 1 hours every 12 hours of operation and will be suitable tropical conditions. C. FUEL TANK :- (i) Fuel tank suitable capacity for 12 Hrs on full load with provision for supply and return lines, level indicator, drain valve, cleaning cover, vent pipe & locking devices shall be provided. (ii) Fuel pipe line from fuel tank to FIP of suitable size. (iii) The fuel tank has to be mounted / located in side the cubicle. D. ACOUSTIC ENCLOSURE :- (i) Designed to meet stringent MOEF/CPCB-IV+ norms 75 dBA @ 1 meter. (ii) Air inlet louvers to be designed to operate at rated load even at 50 degree centigrade air inlet temp. Four point lifting for easy handling. (iii) Cubical to be powder coated for long lasting service life and super finish with UV resistent powder coating, it has to with stand extreme environment. Has to be use stain steel hardware. (iv) Insulation material conforming to IS 8183 speces for better sound. (v) Genset control unit with integrated E-governor helps in reading all genset inputs and controls the genset GCU help in monitoring of following parameters, Controls the engine speed,3 ph genset, low fuel level, support manual control (MCP) functions for 3 phase genset, Measres Genset, Measures Genset Voltages and currents, Measures electrical parameters like frequency, Power factor, Generato, KVA, KW, KVAr, Monitor critical engine safety parameters, Starts/Stops the genset, Have counters for genset start/stop, run hours, KWH, power factor. Contd.....
S & F gang operated air break switch as per IEC 62271-103 amended upto date, rocking/ tilting type with DO fuse assembly , suitable for both horizontal and vertical mounting, three pole mounted on polymer HT insulator 6 nos , outdoor type, nominal system voltage 36 kV, rated frequency 50 Hz, continuous current rating 200 Amps, rated short time withstand current for three seconds 20 kA, rated peak withstand current for three seconds 50 kA, rated lightning impulse withstand voltage (i) to earth and between poles 170 kV (Peak) (ii) across the isolating distance 195 kV (Peak), power frequency withstand voltage between (i) earth & poles 70 kV (rms) (ii) across the isolating distance 80 kV (rms), minimum isolating distance in open position 520 mm, phase to phase clearance 1220 mm, minimum cross sectional area of fixed contact 300 sqmm, minimum cross sectional area of moving contact 250 sqmm, copper connector having minimum cross sectional area of 250 sqmm, maximum current density of 1.6 Amps/ sqmm for all current carrying parts, single number of brake per phase, medium grade galvanised iron pipe of 32 mm nominal bore and 5 to 6 metre length in single piece for operating pipe, pad-locking in both ‘on’ and ‘off’ position with indicators, electroplated nonferrous parts, hot dip galvanised ferrous parts, 3 Nos polymer post insulator per phase as per IEC 61109 amended upto date having rated voltage 36 kV, minimum creepage distance 900 mm, impulse withstand voltage 170 kV, wet power frequency withstand voltage 75 kV, dry wet power frequency withstand voltage 75 kV incl electrical connections, jumpering by ACSR conductor and connectors complete all as specified and as directed.
SEWAGE DISPOSAL WORKS NOTE:- For items of SEWAGE DISPOSAL notes given at the beginning of Sch ‘A’ Part-VII ( SEWAGE DISPOSAL ) shall also be applicable.
Material and Labour for construction of Septic tank 10 users including earth work in any type of soil i.e. excavation, returing filling and removal of any type of soil complete all as specified and as directed all as per Dwg No. CEBZ/TD/29/2022 Note:- The rate of earth work i.e. excavation, returing filling and removal of any type of soil is included in this item and nothing shall be paid extra on this account.
Supply & Fixing of HDPE double wall corrugated sewage pipe 150mm dia. Internal bore SN-8 ISI Marked as per IS16908 Part II 2013 laid in trenches joined and tested as per manufactures instruction complete all as specified & directed.
UG Sump 80000 Gallons NOTE:- For items of UG Sump 80000 Gallons notes given at the beginning of Sch ‘A’ Part-IX ( UG Sump 80000 Gallons ) shall also be applicable.
Supply and fixing for Water Gauge Meter fixed outside of UG Sump complete all as specified and directed .
M&L for applying two coats on nilocate EP-400 solvent free epoxy resin @0.100 Ltrs/Sgm for each coat to achieve a minimum total dry film thickness of 200 microns for potable water retaining structure, first coat must be firmly applied and well scrubbed into the surfaces to form uniform coating with wet film, thickness not less than 100 micron and the first coat should be allowed to be become tack free, then applying second coat using the solvent (epoxy), all Concrete surface must be smooth, sound and free from debris, loose or flaky materials, concrete surfaces must be fully cured and free from any traces of shuttering, release oil and curing compound etc. complete all as specified and directed. Note: Complete treatment willbe done as per Manufacturer instructions.
M&L for PVC water bar or water stops 150 mm wide for concrete structure construction of hydraulic structure to safe guard from water seepage through joints complete all as specified and directed. Complete all as specified and directed. Note: All care should be taken while fixing and installing the water bars and during the concrete pouring as per manufacturer instructions.
M & L , TMT HCR/CRS all as per IS 1786 bars 10mm dia and over, as in reinforcement cut to length , bent to shape requd including cranking , bending spirally for hoopig for columns, hooking end and binding with and incl. mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M & L , TMT HCR/CRS all as per IS 1786 bars 6mm to 8mm dia, as in reinforcement cut to length , bent to shape requd including cranking , bending spirally for hoopig for columns, hooking end and binding with and incl. mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M & L , TMT HCR/CRS all as per IS 1786 bars 5mm and above dia upto 10mm, as in stirrups, spacers and binder reinforcement cut to length , bent to shape required including cranking , bending spirally for hoopig for columns, hooking end and binding with and incl. mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M/s Prayag Construction
Vee kay construction
SHIV SHANKAR MISHRA
M/s Shrangi Rishi Construction
JYOTI ENTERPRISES
M/S AJAY JAIN
M/S UnitedConstruction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .