| 1 | L1₹47.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹50.0 L+₹2.2 L (4.54%)Rejected-Finance AT 381 341 SARITA APARTMENT P O KHARAGPUR KHARIDA MAIN ROAD MIDNAPORE WEST WEST BENGAL 721301 | MEDINIPUR WEST | WEST BENGAL | 721301 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹52.2 L+₹4.4 L (9.18%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹53.5 L+₹5.7 L (11.8%)Rejected-Finance | L4 | Rejected-Finance Not being L1 |
Tender Value
₹43.6 L
EMD Value
₹87,200
Closing Date
26 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF KALAIKUNDA
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore St West Bengal Pin 721303
PROVSION OF AC SOCKETS AND ALLIED WORKS IN SMQ (PHASE-I) AT AIR FORCE STATION KALAKIUNDA UNDER GE (AF) KALAIKUNDA
2022_MES_566042_1
C/8813/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF STN KALAIKUNDA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF KALAIKUNDA
₹87,200
Yes
21 Jan 2023
29 Nov 2022
27 Dec 2022
29 Nov 2022
26 Dec 2022
14 Dec 2022
Amount
M & L for concealed point wiring with and including single core PVC insulated, unsheathed flexible conductor (FRLSH) cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor (FRLSH) cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: (i) The chases in the wall shall be cut with elect cutter and rates of the same will deemed to be included in quoated rates (ii) The disturbed surfaces of wall shall be made good with cement plaster 1:4 including matching the surfaces with as per existing finishes and to the entire satisfaction of Engineer in Charge):- (iii)Wiring to be done as per approved colour code in IE rule. (a) One fan point/Exhaust fan point controlled by one switch 5 Amps
Materials and Labour for concealed type point wiring with 4.00 Sq. mm (nominal area) (FRLSH) as per IS 694: 2010, ISI marked PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, drawn in and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switch socket outlet etc and including 4.00 Sq. mm (nominal area) (FRLSH) PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one 3 Pin 15 Amps socket out let independent, complete all as specified and directed.(Note: (i) The chases in the wall shall be cut with elect cutter and rates of the same will deemed to be included in quoated rates (ii) The disturbed surfaces of wall shall be made good with cement plaster 1:4 including matching the surfaces with as per existing finishes and to the entire satisfaction of Engineer in Charge):- (iii)Wiring to be done as per approved colour code in IE rule.
Supply & fixing Modular metel flush box 3 module complete all as specified and directed.
Supply & fixing Modular metel flush box 2 module complete all as specified and directed.
Supply & fixing Modular white cover plate with frame 3 module complete all as specified and directed.
Supply & fixing Modular white cover plate with frame 2 module complete all as specified and directed.
Supply & fixing Modular switch 1 way 6A, 1 module complete all as specified and directed.
Supply & fixing modular switch socket combination 16 Amp, 6 pin, 3 module complete all as specified and as directed.
S&F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.
Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. Note - Two runs of 4 sqmm cable, one run of 4 sqmm cable and one run of conduit will be measured and paid as one unit length. (Note: Cost of cutting chase and making good shall be deemed to inclusive quoated rates .)
Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. Note - Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of conduit will be measured and paid as one unit length. (Note: Cost of cutting chase and making good shall be deemed to inclusive quoated rates .)
S & F single pole and neutral enclosure with two pin and earth, plug and socket , suitable for single phase 240 V,complete with one single pole MCB of capacity 20 amps having `C` charactristic, breaking cap 10 KA, including industial plug top, complete all as specified and as directed. Make : Legrand cat part No. 607841 or equivelent in Schinder/ L&T.
Material and Labour sheet metal enclosure for double door DBs using MCB 4 way with 200 Amp rated busbar complete all as directed and specified.
S&F double door MCB Distribution board of sheet metal enclosure, triple pole and neutral, 4 way with 200 Amps rated bus bar, 415 volt, IP42 protection grade and fixed with MS hold fast and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.[Cat No. 5076 70 of Make Legrand or equivalent Model of Make L&T/ Seimens]
S&F circuit breakers (MCB), four pole with three protected pole (TPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage 415 V three phase, rated frequency 50 Hz, Rated current 63 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 40 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
Supply,installation,testing and commissioning 3 phase and neutral , 415 volts Feeder Pillar box outdoor type, CPRI approved, factory made free standing , floor mounting ,dust and vermin proof, cubical type LT panel fabricated from 3.0 mm thick CRCA sheet with angle iron frame of 50 x 50 x 6 mm , double door , front and back openable type, double door system, hinged opening , rubber lining,locking arrangement,with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade , protection class IP-66 fully compartmentalize design over all dimension (0.6x0.60x0.50) meter including canopy type roof 15 cm extended in all side with locking arrangement and gasket arrangement with one Nos pad lock of 7 lever and three Nos keys and back side fixed with nuts & guskets, including provision of one set of bus bar of 600 Amps (4 Nos. aluminum strip of size 60mmx10mm of 60 cm long) fixed on porcelain insulator and provision of cable gland for cable entry and aluminium lugs, nut bolts etc for cable connection andcable connection with proper lugs ,PCC foundation and pedestal for fixing LT Panel with PCC 1:5:10 , 15 cm thick in foundation , brick (Fly ash) / PCC block work in CM 1:6 , rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting bolts etc for panel all as specified with and including supply and fixing the following accessories as specified . (The platform shall be of 450mm height above ground level):- (i) Incoming/Outgoing MCCB 4 Pole, 415 volt, 400 Amp rating, with adjustable overload setting and , short circuit setting, Ics-100 % Icu , service breaking capacity 36 KA --- 01 Nos with suitable size aluminium connection busbers covered with PVC sleeves for incoming & out going sides of MCCB's inside the feeder piller box, all as directed as per site requirement. (ii) Aluminium strip should be in RYB-B colour code with heat shrinkable PVC sleeves and hole in busbar strip as directed.
Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and n.exe 1.5 mtr depth including getting out all as specified and directed. Note : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final.
Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any kind of soil all as specified and directed.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point all as specified and directed.
M&L providing sand cushioning with a layer of clean, dry, fine sand for protection of electric cable laid in trenches/ducts, punned down to desired thickness complete all as specified and directed. (Note: For payment purposes only punned down thickness of sand shall be measured )
Supply & Fixing burnt clay fly ash bricks old size designation 75 (kg/cm2) in trenches on cable as cable protection across the length of the cable (width wise) complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3½ core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 120 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3½ core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 35 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Horizontal boring of holes by mechanical means, at under road/ pavement / hard standing etc.,not exceeding 15 Metres in length, in any type of soil, with and including 80 mm bore medium grade , galvanised steel tubing,and making good distrubed surfaces as per existing specification complete all as specified and directed.
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised iron strip 32 x 6 mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed.
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron wire of size 4 mm dia as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @150 c/c both ways, one lifting handle made of 10mm dia TMT bar embedded in cover slab and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternate layer of 15cm thick complete all as specified and directed.
Supply and Fix, Heavy Duty Exhaust Fan, 300 mm sweep, 1400 RPM, Single Phase, 230 V, 50 Hz, all as per Model “Turbo Force” of Make ‘Havells’ or equivalent Model of Make Cromptron Greaves/USHA’ and connecting up including provision of PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 0.50 Sq mm, 3 core, 1100 Volts grade, from ceiling rose/ connector to fan with and louvers, complete all as specified as directed.
Supplying, installing, testing & commissioning, storage water heater (geyser), 25 litres capacity, standing loss less than 0.562 Kwh per day for 45⁰C difference of temperature as per IS 2082 (five-star rated as per BEE), reheating time less than 60 minutes, mixing factor less than 20%, shock proof high density PUF insulation body material, glass lined inner tank material having warranty 7 years on tank material, 4 years on heating element and 2 years on other spares parts comprising following fittings (a) glass coated incoloy element (b) capillary type thermostat (c) digital display unit (d) thermal cutout (e) multifunction valve (f) earth leakage circuit breaker (g) magnesium anode rod cathodic protection (h) flexible cable of suitable length with 3-pin plug of 16A capacity (i) drain plug (j) fusible plug fitted on the crown of water heater with operating temperature between 100⁰C to 110⁰C including fixing by grouting and fastener complete all as specified and as directed.Make JAQUAR/USHA/AO-SMITH or Equivalent make
S & F stainless steel braided flexible connection pipe for hot and cold water supply for geyser, 15 mm bore, 600 mm length, 12 bar working pressure complete all as specified and as directed.
Supply and Fix, bib tap, cast copper alloy, fancy type, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule,15 mm bore and fixed, complete all as specified and directed.
Supplying & fixing to walls and ceiling 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
S & F 15 mm nominal size, nonrising spindle type fancy angle stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
Cutting openings, through brick walls built in cement mortar or cement lime mortar, for exhaust fan and other openings or enlarging existing openings, superficial area exceeding 0.16 Sqm but not exceeding 0.25 Sqm, making good distrubed portion, grouting of suitable bolts with nuts & washers for fixing exhaust fan,rendering 15 mm thick plaster in CM (1:4) around jambs of opening, complete all as specified and directed.
S&F single phase direct connection type KWH meter , temper proof, plastic body with LCD display, 230/240V, 5-30 Amp, accuracy class I, 50 Hz, Conf to IS 13779, IP 54, with (parameters to show Date, time, current reading, KW, PF) in existing position by providing Polycarbonate box cover, including making complete connection made up from Main DB to meter by 6 sqmm single core copper conductor complete all as specified and as directed. Make - L&T, Model- WM101BC5DDHBOX or equivalent make as catered in PS.
Lotas Engineers
NAVYUG CONSTRUCTION
M/S. CONCO CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .