Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 LAccepted-AOC 4626 MALOYA CHANDIGARH | NA | NA | 160001 | ₹1.6 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹1.7 LRejected-Finance CHANDIGARH | ₹1.7 L | L2 | Rejected-Finance L2 |
| 3 | L3₹2.0 LRejected-Finance | ₹2.0 L | L3 | Rejected-Finance L3 |
| 4 | L4₹2.1 LRejected-Finance BLOCK B SECTOR 26 CHANDIGARH | ₹2.1 L | L4 | Rejected-Finance L4 |
Updated dates
Tender Value
₹2.7 L
EMD Value
₹5,370
Closing Date
20 Apr 2026, 12:00 pmClosed
Er. Gurpreet Singh Bains
Office of the Executive Engineer, Electrical Division No. 1, Sector-9,Chandigarh.
MTC. OF E.I. RB (RESIDENTIAL BUILDING) CHANDIGARH, (WIRING AND REWIRING, SWITCHGEAR IN VACANT HOUSE NO. 339) (TYPE-IX). AND OTHER HOUSE, SECTOR-22, CHANDIGARH.
2026_CHD_91670_1
E1/TN-11
Open Tender
Electrical Works
30 days
Chandigarh
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹5,370
4 May 2026
10 Apr 2026
20 Apr 2026
10 Apr 2026
20 Apr 2026
10 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
DSR Item No. 1.10
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. | - | - | - | - | |
Group B | 32 | Each | - | - | |
DSR Item No. 1.15
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required. | - | - | - | - | |
Group B. | 32 | Each | - | - | |
DSR Item No. 1.16
Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. | 4 | Each | - | - | |
DSR Item No. 1.17
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | - | - | - | - | |
3 x 1.5 sq. mm | 280 | PM | - | - | |
3 x 2.5 sq. mm | 150 | PM | - | - | |
6 x 6 sq. mm | 26 | PM | - | - | |
DSR Item No.1.21
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. | - | - | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.88 MB
BOQ_112161.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid