| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.6 LAccepted-AOC 110 5 BONOMALI NASKAR ROAD BEHALA PARNASHREE PARNASHREE KOLKATA WEST BENGAL 700060 | KOLKATA | WEST BENGAL | 700060 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹37.1 L+₹1.3 L (3.73%)Rejected-Finance 22A ASWINI DUTTA ROAD KOLKATA 700029 | KOLKATA | WEST BENGAL | 700029 | L2 | Rejected-Finance Being higher bid value | |
| 3 | L3₹37.7 L+₹2.0 L (5.60%)Rejected-Finance | L3 | Rejected-Finance Being higher bid value |
Tender Value
₹36.5 L
EMD Value
₹73,000
Closing Date
21 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ALIPORE KOLKATA
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
8012/B/E8
2021_MES_492285_2
GE/ALP (8012B) OF KOLKATA 2021-22
Open Tender
Civil Works
Item Rate
330 days
GE ALIPORE KOLKATA
Class D and C (vii)
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER ALIPORE
₹73,000
Yes
28 Mar 2022
22 Feb 2022
22 Mar 2022
22 Feb 2022
21 Mar 2022
7 Mar 2022
60 days
Amount
Comprehensive maintenance of water treatment plant for safe and efficient running at Main Pump House CH(EC) for a period of each calender months for the plant capacity of 20000 GPH (90 Cum/hr) and consisting of the following accessories of this plant :- (a) One oxidation chamber (b) Multigraded filter (c) Two number softner capacity 20000 GPH (90 Cum/hr) each (d) Two brine solution tank 1500 ltr Each & one no RCC Tank. (e) One no Chlorine dosing pumps Model NGQ 51 Make Declibac, HP - 1/3 Frictional, output 02 US GPD to 40 US GPD RPM-44, power 230 volt 50 HZ.
Comprehensive maintenance of water treatment plant for safe and efficient running at New MAP Pump House II line for a period of each calender month for the plant capacity of 10000 GPH and consisting of the following accessories for this plant :- (a) One oxidation chamber (b) Multigraded filter capacity (c) One number softner capacity (d) One brine solution tank.
Comprehensive maintenance of water treatment plant for safe and efficient running at MAP PHASE - II Pump House II line for a period of each calender month for the plant capacity of 8,000 GPH and consisting of the following accessories for this plant :- (a) One oxidation chamber (b) Multigraded filter capacity (c) One number softner capacity (d) One brine solution tank. (e) Silver ionisation plant, Make - Senco (Bharati Water), Model ERA - 50 capacity 50, 000 LPH incl with DOL starter & V-guard Voltage stabilizer
Comprehensive maintenance of water treatment plant for safe and efficient running at MAP PHASE - I Pump House II line for a period of each calender month for the plant capacity of 10,000 LPH and consisting of the following accessories for this plant :- (a) One oxidation chamber 10 000 LPH (b) Multigraded filter capacity 10, 000 LPH (c) One number softner capacity 10,000 LPH (d) One brine solution tank. Note :-for item No. 01 to 04 (i) Contractor shall be responsible for making salt solution and charging of salts. (ii) Hardness testing on daily basis & Iron testing in every day intervals (Testing kit will be paid under relevant item) and labratory test on every 15 days interval. (iii) Responsible for rectification of any leakage from inlet to out let connection with existing pipe line, including replacement of gasket, nut bolts or any tools required at site or blocking of softener including any other defects in plant .
Comprehensive maintenance of Reverse osmisis(RO) plant for safe and efficient running at New pump house II line for a period of each calender months including Sunday and holiday for the plant capacity of 6000 LPH, Make- Ion Exchange and consisting of the following accessories:- Raw water feed pump-01 No. Oxidation chamber-01 no Dual media filter-1 no Micron filter-01 no R.O.Houshing-02 nos UV System-01 no Antiscalant dozing tank-1 no Antiscalant dozing pump -1 no High pressure pump-01 No.
Comprehensive maintenance of Reverse osmisis(RO) plant for safe and efficient running installed at Technical building (on roof) , CH area for a period of each calender months including Sunday and holiday for the plant capacity of 2X5000 LPH, Make- Ion Exchange and consisting of the following accessories:- Raw water feed pump-02 Nos. Oxidation chamber-02 nos. Dual media filter-02 nos Micron filter-02 nos R.O.Houshing-02 nos Antiscalant dozing tank-02 nos Antiscalant dozing pump - 04 nos High pressure pump-02 Nos.
All as per item No.6 abpve but RO plant of cap 1000 LPH installed at MAP Ph-II Pump House , II Line area.
All as per item No.6 abpve but RO plant of cap 500 LPH installed at CMDC , CH area
Note-:For item No.05 to 08 (i) Contractor shall be responsible for making of antiscalant solution and charging of antiscalant. (ii)Responsible for rectification of any leakage from inlet to out let connection with existing pipe line, including replacement of membrane stainer, catridge, gravels, valve gasket, nut bolts or any tools required at site. (iii) Unit rate shall be deemed to be inclusive of taking down unserviceable defective parts/accessories and replacement with new one ,including fixing of spare parts, filters, membrane etc as and when required for smooth and efficient functioning of the plant. (iv) Any minor spare parts which has not been considering in "supply only", and is required for smooth functioning of plants (v) New spare parts requird for renewal shall be measured and paid for separetly as "Supply only" under relevant items here in after. (vi)one mehanic of ITI holder having minimumm 5 year experience should maintain the plant. The machanic will be responsible for checking the plants output not any instance reduces more than 20 % of its rated capacity,also will be responsible for checking of water hardness,TDS ,and chlorine content on daily basis. However if there is any negligence or not attending site and checking the plants and reporting to conceren JE regarding the daily performance of RO plants a penal recovery of Rs. 500 per day basis will be charged from contractor as penal recovery. Contractor will be responsible for checking of water quality on daily basis and will submit the water quality test report on fortnightly basis conductrd from govt accredited laboratory, in case of non submission a penal recovery of Rs. 2000 per plant per fortnightly basis will be recover.
Supply and fixing in repair gun Metal gate valve 15 mm dia after taking out old unserviceable one complete
Supply and fixing in repair MS short piece of dia 150mm to 40mm of size 0.22 Rm to 0.40 Rm with both end flenged for filteration pipe line as per sample and directed by engr in charge.
Supply and fixing in repair MS bend of dia 80 to 150 mm, 90 degree with one end flanged suitable for filteration pipe line as per sample and directed by engr in charge.
Supply and fixing in repair Butterfly valve 150 mm confirming to IS-13095 hand operated suitable for filteration, complete all as specified and as directed by engr-in charge.
Supply and fixing in repair, CI sluice valve 80 mm dia with SS spindle ISI marked, PN 1.6 with MS bolts, nuts & washers and a pair of gasket joints having suitable thickness suitable for filteration plant, complete all as specified and as directed by engr-in charge.
Supply and fixing in repair, MS Tee joint of dia 150mm / 100mm/80 mm of size 0.45 Rm / 0.33 Rm with both end flenged suitablefor filteration pipe line as per sample and directed by engr in charge.
Material and labour for Cutting 150 /100 /80 mm MS pipe line any length and fixing of flanged by means of welding all as directed by engr in charge.
Supply and fixing Feed rate control kit for chlorine dozing pump
Supply and fixing in repair ,Pump head service kit Part No KSKH07 for chlorine dozing pump
Supply and fixing in repair , Pump tube (26 -100 psi) Single head only , Part No MCCP207 for chlorine dozing pump complete all as specified and as directed by engr-in charge.
Supply and fixing in repair, Injection check Vavle 3/8" Part No MCINJ38 ,for chlorine dozing pump complete all as specified and as directed by engr-in charge.
Supply and fixing in repair ,Connecting Nut 3/8" with Adapter Part No MCADPTR ,for chlorine dozing pump complete all as specified and as directed by engr-in charge.
Supply and fixing in repair, Suction line strainer 3/8" (weight including ) Part No ST138 ,for chlorine dozing pump complete all as specified and as directed by engr-in charge.
Supply only multiport valve for R.O. Plant
Supply only 8 " RO End cap assemly for R.O. Plant of cap 6000 LPH
Supply only , 1" SS Ball valve for R.O. Plant
Supply only of chemical dozingig pump for R.O. Plant
Supply only , 4" Jumbo catridge for R.O. Plant
Supply only ,4" jumbo housing for R.O. Plant
Supply only , low pressure switch for R.O. Plant
Supply only , high pressure switch for R.O. Plant
Supply only, 25/40 mm SS Victoly coupling for R.O. Plant
Supply only , Rotameter for R.O. Plant
Supply only , electrical DOL for 7.5/10 HP starter for R.O. Plant
Supply only , 8" membren for New pump house R.O. Plant for plant capacity 6000 LPH
Supply only , 8" membren for Defi tech building R.O. Plant for plant capacity 5000 LPH
Supply only , 4" membren for R.O. Plant
Supply only , NGXL stainer for R.O. Plant
Supply only , 4" pressur gauge for for R.O. Plant
Supply only , 2.5" pressur gauge for for R.O. Plant
Supply only , NRV for Dozing pump NRV R.O. Plant
Supply & fixing in repair 50 mm dia UPVC pipe for RO plant with fittings complete like bend ,elbow at any angle,Tee, thread adapter, end cap thread adapter brass at any angle, reducer, coupler, open, blind flange etc complete required for plumbing on each meter length .
Supply & fixing in repair 40 mm dia UPVC pipe for RO plant with fittings complete like bend,elbow at any angle,Tee ,thread adapter, end cap thread adapter brass at any angle, reducer, coupler, open, blind flange etc complete required for plumbing on each meter length .
Supply & fixing in repair 25 mm dia CPVC pipe for RO plant with fittings complete like bend,elbow at any angle,Tee, thread adapter, end cap thread adapter brass at any angle, reducer, coupler, open, blind flange etc complete required for plumbing on each meter length .
Supply & fixing in repair 20 mm dia CPVC pipe for RO plant with fittings complete like bend, elbow at any angle,Tee, thread adapter, end cap thread adapter brass at any angle, reducer, coupler, open, blind flange etc complete required for plumbing on each meter length .
Supply only , socket/elbow / MTA dia 50/40mm for R.O. Plant
Supply only , socket/elbow / MTA dia 25/20mm for R.O. Plant
Supply only , union , 1.5" for R.O. Plant
Supply only , Teflon tape for for R.O. Plant
Supply only , solment pest for R.O. Plant
Supply only , CPVC Bal valve ,40 mm dia for R.O. Plant
M&L for two coats of bituminious paint suitable for drinking water after necessary preparation of internal surfaces of plants complete all as specified and directed by Engr-in-charge.
M&L for two coats of synthetic aluminium paint external surfaces over a coat of red oxide primer of plants/ pipes after preparationof surfaces complete all as specified and directed.
S&F as in repair for HDPE pushfit type umbrella type strainer for multigrade filter and water softner.
Supply and fixing in repair of cleaning, washing, screening and filling the media inside the multigrade filter pressure filter media/gravels of following sizes.
(a) 25 mm to 20 mm
(b) 20 mm to 16 mm
(c) 16 mm to 8 mm
(d) 8 mm to 3 mm
Supply, cleaning and filling the filter sand inside the pressure filter (type of sand 16/30 mesh) complete all as specified and directed. Source : Baraker river.
Supply & charging in repair inside the oxidation chamber of catalyst (MNO2 ), complete all as specified and as directed
Supply and fixing as in repair, CI diapharam valve 150 mm bore, complete all as specified and as directed Make : Hazra/ Parboti/Kirloskare or equivalent
Supply and fixing as in repair, CI diapharam valve 100 mm bore, complete all as specified and as directed .Make : Hazra/ Parboti/Kirloskare or equivalent
Supply and fixing as in repair, CI diapharam valve 80 mm bore,complete all as specified and as directed .Make : Hazra/ Parboti/Kirloskare or equivalent
Supply and fixing as in repair of water pressure guage 0 - 10 Kg/Sqcm cap dia 150 mm
Supply and fixing as in repair of water pressure guage 0 - 10 Kg/Sqcm cap dia 100/80 mm
Material and labour for water hardness testing chemicals re-agent solution A B C and glass vessel for water testing
Material and labour for Chlorine testing and glass vessel for water testing
Supply & pouring in repair resing inside bed of oxidation chamber. Make : ION Exchange (INDION 225 NA) or equivalent.
S&F in repair for Gun metal gate valve with iron wheel head, screwed down iron pipe of 25 mm bore. complete all as specified and as directed.
Supply & fixing in repair , rubber for ,CI diapharam valve 150/100 /80 mm bore Make : Hazra/ Parboti/Kirloskare or equivalent
Supply & fixing in repair ,of micron cartage 5 micron of RO filter cum purifier of cap 25 LPH
Supply & fixing in repair ,of carbon cartage 5 micron of RO filter cum purifier of cap 25 LPH. make - Livpure or equivalent
Supply & fixing in repair ,of adaptor 220- 24 volt DC for RO filter cum purifier of cap 25 LPH. make - Livpure or equivalent
Supply & fixing in repair ,of carbon block for RO filter cum purifier of cap 25 LPH. make - Livpure or equivalent
Supply & fixing in repair ,of pressure busting pump for RO filter cum purifier of cap 25 LPH. make - Livpure or equivalent
Supply & fixing in repair , membren of 75 GPD compact for RO filter cum purifier of cap 25 LPH. make - Livpure or equivalent
Supply & fixing in repair ,of low and high pressure switch for RO filter cum purifier of cap 25 LPH. make - Livpure or equivalent
Supply & fixing in repair ,of UV Lamp for RO filter cum purifier of cap 25 LPH. make - Livpure or equivalent
Supply & fixing in repair, of solenoid valve for for RO filter cum purifier of cap 25 LPH. make - Livpure or equivalent
Supply & fixing in repair, of 6 mm pipe for RO filter cum purifier of cap 25 LPH. make - Livpure or equivalent
M & L for Opening the top, bottom & side cover of the existing plants consisting of the iron removal plant of capacity 90000 LPH, including two softner plant, taking out the existing filler materials i.e. sand, gravels, resins, PVC strainer etc for cleaning, separation & stacking at site for re-use and re-filling the same as directed by Engr-in-charge.
M & L for Opening the top, bottom & side cover of the existing plants consisting of the iron removal plant of capacity 45000 LPH, including softner plant, taking out the existing filler materials i.e. sand, gravels, resins, PVC strainer etc for cleaning, separation & stacking at site for re-use and re-filling the same as directed by Engr-in-charge.
M & L for Opening the top, bottom & side cover of the existing plants consisting of the iron removal plant of capacity 10000 LPH ,including softner plant, taking out the existing filler materials i.e. sand, gravels, resins, PVC strainer etc for cleaning, separation & stacking at site for re-use and re-filling the same as directed by Engr-in-charge.
M & L for Opening the top, bottom & side cover of the existing plants consisting of the iron removal plant of capacity 36000 LPH ,including softner plant, taking out the existing filler materials i.e. sand, gravels, resins, PVC strainer etc for cleaning, separation & stacking at site for re-use and re-filling the same as directed by Engr-in-charge.
Labour only for Mixing and dosing calcium hypochlorite based granular chlorination chemicals (disinfectant for water treatment) complete all as specified and as directed at site by the Engr-in-charge. Note:- Calcium hypochlorite shall be issued for free for dosing under schedule 'B'. Transportation of chemical from MES Store to dosing point shall deemed to be included in quoted unit rate.
Supply and mixing common salt (Non iodised best quality locally available of 50 Kg bag complete all as specified and as directed at site by the Engr-in-charge. Note- Salt supplied by contractor and he will have to mixing in IRP plant , which are installed at New pump house, Main pump house, MAP Ph-II Pump house and MAP Ph-I pump house according to direction of Engr-in charge
Supply and dosing Antiscalant solution 5 mg/ltr for Reverse Osmosis plant to minimize/eliminates acid feed for scale control for improving system efficiency, inhibition for CaCo3, CaSO4, metal oxides & moderate scale, NSF certified, for RO plant of MAP Phase II, RO plant near New pump house, RO Plant of CMDC and RO plant of Defi Tech Bldg complete all as specified and as directed. Make : ion exchange Brand INDION 8111, Zeolite or equivalent.
Supply and mixing bleaching Powder as per IS-1065 (Latest Edition) complete all as specified and as directed at site by the Engr-in-charge.
EAST COAST STANDARD PRODUCTS
JAIN CONSTRUCTION AND ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .