| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.5 LAccepted-Finance GC ROAD ABDUL LATIF ROAD PO TITAGARH KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | ₹31.5 L | L1 | Accepted-Finance Being a lowest bidder and reasonable |
| 2 | L2₹34.1 L+₹2.6 L (8.39%)Rejected-Finance 44B CIRCULAR GARDEN REACH ROAD KOLKATA 700 023 | KOLKATA | WEST BENGAL | 700023 | ₹34.1 L+₹2.6 L (8.39%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹34.3 L+₹2.8 L (8.78%)Rejected-Finance 22 2 BAKRAHAT ROAD THAKURPUKUR KOLKATA 700063 | KOLKATA | KOLKATA | WEST BENGAL | 700063 | ₹34.3 L+₹2.8 L (8.78%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹34.3 L+₹2.8 L (9.04%)Rejected-Finance 3 IBRAHIM ROAD KHIDDERPORE KOLKATA 700023 | KOLKATA | WEST BENGAL | 700023 | ₹34.3 L+₹2.8 L (9.04%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹37.1 L+₹5.6 L (17.9%)Rejected-Finance 10 1 GROUND FLOOR WEST GHOSH PARA JAGATDAL JAGATDAL JAGATDAL NORTH 24 PARGANAS WEST BENGAL 743125 | 24 PARAGANAS NORTH | WEST BENGAL | 743125 | ₹37.1 L+₹5.6 L (17.9%) | L5 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | INDIA ELECTRICAL EQUIPMENTS L2 | KWALITY CONSTRUCTION L1 | RADHA ENTERPRISE L5 | ELECTRO FREEZE L3 | EASTERN REFRIGERATION AND ELECTRICAL CO L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down for servicing of split type AC 1.5TR Capacity including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner Or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., changing electrical connections if required and keeping the AC unit in satisfactory working condition after necessary servicing and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge. | 35 | Each JOB | 160 ₹5,600 | 140 ₹4,900 Lowest | 162 ₹5,670 | 160 ₹5,600 | 158 ₹5,530 |
| 2.00 | Taking down for servicing of split type AC 2.0TR Capacity including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., changing electrical connections and keeping the AC unit in satisfactory working condition after necessary servicing and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge. | 25 | Each JOB | 400 ₹10,000 | 385 ₹9,625 Lowest | 395 ₹9,875 | 400 ₹10,000 | 395 ₹9,875 |
| 3.00 | Taking down for servicing of Window type AC 1.5TR Capacity including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing electrical connections and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge. | 5 | Each JOB | 175 ₹875 | 150 ₹750 Lowest | 180 ₹900 | 175 ₹875 | 170 ₹850 |
| 4.00 | Taking down for servicing of Window type AC 2.0 TR Capacity including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing electrical connections and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge. | 5 | Each JOB | 200 ₹1,000 | 180 ₹900 Lowest | 215 ₹1,075 | 210 ₹1,050 | 195 ₹975 |
| 5.00 | Supply and fix in repairs starting relay for 1.5 TR compressor all as specified and directed. | 35 | Each | 330 ₹11,550 | 325 ₹11,375 Lowest | 335 ₹11,725 | 330 ₹11,550 | 325 ₹11,375 Lowest |
| 6.00 | Supply and fix in repairs starting relay for 2 TR compressor all as specified and directed. | 35 | Each | 400 ₹14,000 | 405 ₹14,175 | 420 ₹14,700 | 415 ₹14,525 | 395 ₹13,825 Lowest |
| 7.00 | Supply and fix in repairs over load protector for 1.5 TR compressor all as specified and directed. | 23 | Each | 390 ₹8,970 | 385 ₹8,855 Lowest | 415 ₹9,545 | 410 ₹9,430 | 398 ₹9,154 |
| 8.00 | Supply and fix in repairs over load protector for 2TR compressor all as specified and directed. | 15 | Each | 435 ₹6,525 | 425 ₹6,375 Lowest | 445 ₹6,675 | 450 ₹6,750 | 440 ₹6,600 |
| 9.00 | Supply and fix in repairs Thermostate switch for 1.5 TR split/window type AC all as specified and directed. | 20 | Each | 375 ₹7,500 | 370 ₹7,400 Lowest | 390 ₹7,800 | 385 ₹7,700 | 380 ₹7,600 |
| 10.00 | Supply and fix in repairs Thermostate switch for 2 TR split/Window type AC all as specified and directed. | 20 | Each | 385 ₹7,700 | 380 ₹7,600 Lowest | 396 ₹7,920 | 395 ₹7,900 | 390 ₹7,800 |
Tender Value
₹29.5 L
EMD Value
₹59,000
Closing Date
19 Jun 2026, 6:00 pmClosed
Garrison Engineer (FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
REPAIR/MAINT OF SPLIT/VERTICAL/WINDOW AIR CONDITIONERS, REFRIGERATORS, WATER COOLERS ALONGHWITH ANCILLARY ITEMS OF DIFFERENT OTM ACCNS INSIDE VIJAY DURG UNDER GE(FW) KOLKATA
2026_MES_768563_1
8598/E8
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
270 days
Garrison Engineer (FW) Kolkata
AS PER NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer (FW) Kolkata
₹59,000
Yes
10 Sept 2026
29 May 2026
20 Jun 2026
29 May 2026
19 Jun 2026
12 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down for servicing of split type AC 1.5TR Capacity including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner Or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., changing electrical connections if required and keeping the AC unit in satisfactory working condition after necessary servicing and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge. | 35 | Each JOB | - | - |
| 2 | Taking down for servicing of split type AC 2.0TR Capacity including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., changing electrical connections and keeping the AC unit in satisfactory working condition after necessary servicing and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge. | 25 | Each JOB | - | - |
| 3 | Taking down for servicing of Window type AC 1.5TR Capacity including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing electrical connections and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge. | 5 | Each JOB | - | - |
| 4 | Taking down for servicing of Window type AC 2.0 TR Capacity including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing electrical connections and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge. | 5 | Each JOB | - | - |
| 5 | Supply and fix in repairs starting relay for 1.5 TR compressor all as specified and directed. | 35 | Each | - | - |
| 6 | Supply and fix in repairs starting relay for 2 TR compressor all as specified and directed. | 35 | Each | - | - |
| 7 | Supply and fix in repairs over load protector for 1.5 TR compressor all as specified and directed. | 23 | Each | - | - |
| 8 | Supply and fix in repairs over load protector for 2TR compressor all as specified and directed. | 15 | Each | - | - |
| 9 | Supply and fix in repairs Thermostate switch for 1.5 TR split/window type AC all as specified and directed. | 20 | Each | - | - |
| 10 | Supply and fix in repairs Thermostate switch for 2 TR split/Window type AC all as specified and directed. | 20 | Each | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.46 MB
pdfjoiner8598.pdf
Tender Documents • 1.00 MB
BOQ_860687.xls
BOQ • 2.07 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .