| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L4₹4.6 Cr−₹35.9 L (7.18%)Accepted-AOC HOUSE NO 953 SECTOR 23 HUDA BHIWANI TEHSIL AND DISTRICT BHIWANI | BHIWANI | BHIWANI | HARYANA | ₹4.6 Cr−₹35.9 L (7.18%) | L4 | Accepted-AOC Awarded |
| 2 | L1₹5.0 CrRejected-AOC NEAR SHIV MANDIR VILLAGE RAJPURA KHARKARI TEHSIL AND DISTRICT BHIWANI 127031 | BHIWANI | HARYANA | 127031 | ₹5.0 Cr | L1 | Rejected-AOC Refunded |
| 3 | L2₹4.9 Cr−₹6.8 L (1.37%)Rejected-AOC | ₹4.9 Cr−₹6.8 L (1.37%) | L2 | Rejected-AOC Refunded |
| 4 | L3₹4.9 Cr−₹6.3 L (1.25%)Rejected-AOC MITTAL FARM LOHARU ROAD CHARKHI DADRI 127306 | CHARKI DADRI | HARYANA | 127306 | ₹4.9 Cr−₹6.3 L (1.25%) | L3 | Rejected-AOC Refunded |
| 5 | L5₹6.1 Cr+₹1.1 Cr (21.0%)Rejected-AOC NEAR GAURAV ICE FACTORY LOHARU ROAD CHARKHI DADRI 127306 | CHARKI DADRI | HARYANA | 127306 | ₹6.1 Cr+₹1.1 Cr (21.0%) | L5 | Rejected-AOC Refunded |
Tender Value
₹5.2 Cr
EMD Value
₹10.4 L
Closing Date
8 Jul 2022, 5:00 pmClosed
Executive Engineer, PHE Division No.3, Narnaul
Executive Engineer, PHE Division No.3, Narnaul
Construction of balance work of brick lining SandS tank, Road paths, boundary wall, white washing of structures, laying the the 200 mm to 600 mm id DI rising main lines, providing and fixing of sluice valves gate, electric panel board, cable etc comp
2022_HRY_225940_1
EIC Panchkula memo No. 51054 dt. 09-06-2022
Open Tender
Civil Works
Works
540 days
Ateli
Please refer tender documents
4 documents required · 4 mandatory
₹20,000
₹10.4 L
Yes
15 Sept 2022
16 Jun 2022
9 Jul 2022
16 Jun 2022
8 Jul 2022
16 Jun 2022
Amount
Supply, erection, testing IS marked copper wire for various motors with underground system in PVC and flexible pipes copper wire 3 core complete in all respective with accessories like thimble etc. (1.2 ) 70 mm 2 3 core
Supply & erection of LT cable 1100 volts alluminium conductior armored cable ISI marked including thimbles & lugs 1 m. below ground level covered with sand and bricks with all labour and material including digging & refilling of trenches as per existing condition required to complete the job in all respect to the entire satisfaction of Engineer-in-charge of the work. 240 sq. mm 31/2core
Supply & Fixing of Mechanical Joints PN 1.6 alongwith ruber gaskit & galvanized nuts / bolts complete in all respect. (3.1) 200 mm i/d
Supply erection testing of reputed make LED light 100 wats with fittings and accessories complete in all repects.
Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) cast Iron, class B (IS 1536) (5.1) 350 mm i/d
Supply, erection, testing & commissioning of wall mounted electrical L.T. Panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of suitable size deep having follwing items For Clear Water Pumping Sets of 150 BHP. = 3 No. a) Main switch suitable amp. 3 No. (L&T Siemens, ABB) b) CT 100/3 = 3Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Soft starter for 1700LMPx 40 Mtr. = 3 No (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each)
Supply, fixing, jointing & commissioning of suitable size mannual operated CI sluice gate including pen stock, operating wheal, all labor, jointing material & acessories which are required complete in all respect to the entire satisfaction of Engineer-in-charge & specifications mentioned in DNIT. Suitable size for 900 X 600 mm opening
H.T. Metering Panel. Supply, erection, testing & commissioning of HT metering panel 11 KV consisting of One No. Electric Trivector meter 3 phase 4 wire 0.5 class of accuracy on KW hour point basis complete with HT CTs of 20/5 Amp 15 VA burden and class of 0.5 accuracy and HT PT 11000 V 15 VA burden and class of 0.5 including metering cubical complete in all respect as per site requirement complete in all respect as per approved DNIT. For Water works at Bhalki
AUTOMETIC POWER PACTOR CONTROL PANEL. Supply, erection, testing & commissioning of Autometic Power Factor control panel at 90KVAR capacitor complete as per specification mentioned in the as per approved NIT complete in all respect as per approved NIT.
Supply, erection, testing and commissioning in HT epoxy type cable boxes for 35mm HT/11 KV XLPE 3 core galvanized steel strip armoured cable including material/ Required for complete erection of the same such as thimble lugs. Solder compound etc. complete in all respect as described in schedule No. II as per approved NIT. (10.1) For Outdoor Installation
(10.2) For Indoor Installation
Supplying and fixing of HT cable 11000 Volts ISI marked 35.00 sqmm 3.0 core HT metering panel to GO switch & GO switch to Transformer. Water Works Bhalki for HT panel complete in all respect as per approved DNIT.
Bidder Name
Amount
Ravinder Sharma Contractor(GSTN-06APJPR8270D1ZO)
Narender Singh Contractor(GSTN-06AXBPS0272N1Z8)
RAM PHAL SINGH CONT(GSTN-NA)
MAHA LAXMI CONSTRUCTION COMPANY(GSTN-NA)
ANAND KUMAR CONT(GSTN-NA)
M/S Jai Hanuman Builder(GSTN-NA)
VIKASH BADESRA CONT(GSTN-NA)
Rakesh Yadav Contractor(GSTN-NA)
RAM PHAL SINGH CONT
ANAND KUMAR CONT
MAHA LAXMI CONSTRUCTION COMPANY
VIKASH BADESRA CONT
Narender Singh Contractor
Rakesh Yadav Contractor
M/S Jai Hanuman Builder
ANAND KUMAR CONT
RAM PHAL SINGH CONT
Ravinder Sharma Contractor
M/S Jai Hanuman Builder
Rakesh Yadav Contractor
VIKASH BADESRA CONT
Narender Singh Contractor
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .