| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.8 LAccepted-AOC 9 EZRA STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | ₹40.8 L | L1 | Accepted-AOC Accept |
| 2 | L2₹48.3 L+₹7.5 L (18.4%)Rejected-Finance | ₹48.3 L+₹7.5 L (18.4%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹50.6 L+₹9.8 L (24.0%)Rejected-Finance | ₹50.6 L+₹9.8 L (24.0%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹51.0 L+₹10.2 L (25.0%)Rejected-Finance | ₹51.0 L+₹10.2 L (25.0%) | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹51.1 L+₹10.3 L (25.3%)Rejected-Finance 101 GROUND FLOOR RAJASTHALI ENCLAVE DUMARDAGA RANCHI JHARKHAND 834012 | RANCHI | JHARKHAND | 834012 | ₹51.1 L+₹10.3 L (25.3%) | L5 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | Prasur Electricals & Engineering Co. L1 | M/s Karbhagam Sales Agency L4 | Tropical Refrigeration L6 | OPS Associates L2 | M/S SHRI SHYAM BUILDERS L5 | excellent Enterprises L3 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, install, test and commissioning of 250 KVA/200 KW DG set diesel engine driven Generating set with alternator out put Voltage 415 Volts +/- 1% at set value of 415 V at a frequency 50HZ +/- 0.5%, suitable for prime duty with STD control panel outdoor type IP-54 consisting of AMF feature to be erected, (NTP for suitable for installing at Minniebay Port Blair, all mounted in acoustic enclosure and Control panel as per manufacturer's design and specification confirming to latest norms of CPCB complete with the following and connected accessories with necessary T&P complete :-
i) Inbuilt DG Fuel tank of minimum capacity for 12 Hrs operation on full load with fuel gauge etc complete all as per OEM recommendations
ii)Battery & Leads
iii)Silencer with pipe line & radiator as per OEM design & recommendations complete as per latest CPCB norms
iv)AVM Pads
v)First Fill of Lube
vii)Acoustic Enclosure
viii)Standard Control Panel( AMF) outdoor type with connected switchgear/relays/meters complete IP-54. | 1 | Each Job | 33,74,000 ₹33,74,000 Lowest | 40,99,900 ₹40,99,900 | 41,52,000 ₹41,52,000 | 40,94,500 ₹40,94,500 | 41,00,000 ₹41,00,000 | 40,80,000 ₹40,80,000 |
| 1.01(ix) Suitable size cement concrete foundation platform of canopy base with height as required at site to mount the generator as per manufacturer's instructions/ recommendations. The cost of foundation bed including earth work etc shall deemed to be included in the quoted rate. (x) Connecting cables, from existing panels and connecting cables , cables glands, cable lugs to new panel complete with all necessary accessories. (xi) Install on the foundation, provn & install connecting fuel pipe lines, cables etc. (xii) Test and commissioning complete including POL and resistive load bank required for testing. (xiii) The cost of control cables from engine Control panel to AMF panel, transportation, installation, testing & commissioning etc shall be deemed to be included in the cost quoted. (xv) The quoted rate shall deemed to be inclusive of earth work for foundation, Cement concrete foundation as per OEM design, dismantling of brickwall/PCC/tiles and making good the disturbed surfaces including repairs/replacement of brickwall/tiles/pcc & provision of steel wire mesh for providing proper exhaust/breathing system to DG set, Cabling etc incl necessary T&P for transportation and installation complete. | |||||||||
| 1.02(xiv) The details specifications appended below :- (I) ENGINE (a) General: Suitable four stroke compressed ignition, radiator water cooled,Turbocharged aspiration, continuous duty with 10% overload capacity for 1 hour in 12 hours continuous running, with 40 to 50°C intake air temperature, latest CPCB Euro emission engine ,turbocharged four stroke engine developing minimum 306 BHP @ 1500 RPM under NTP conditions, coupled to alternator mounted on Channel Iron base frame with in built fuel tank of minimum capacity suitable for 12 Hrs operation complete .The prime mover provided should be as per IS specifications. (b) Air intake system : Should comprise of dry type intake air filter mounted on engine, one in number vacuum indicator mounted on intake piping. (c ) Exhaust System: Should comprise of one exhaust manifold, dry type, mounted on engine, one exhaust hospital type silencer which should be positioned in such a way that the exhaust gas is not sucked by the fan on the radiator/heat exchanger, thereby affecting the cooling system. The silencer should cater to the noise level tolerance prescribed in the relevant IS/BS. The silencer should be provided with flaps with a provision so that it will open only when the generator is running. The complete exhaust system shall be properly supported so that entire lot of the exhaust system shall not fall on the DG Set. | |||||||||
| 1.03(d) Fuel System: Should comprise of disposal type element fuel filter, pressure type fuel pump mounted on engine, non return check valve in fuel supply and drain lines, wire braided hose between filter and pump, fuel system with suitable capacity electronic governor and engine mounted actuator. The fuel tank must have proper locking arrangement with level indicator and to be fixed seperately / externally. (e) Cooling System: Should comprise of radiator and connected pipeline complete, hospital type silencer and tested for 50°C ambient temperature with 7 PSI pressure cap mounted on base rail. The thermostat installed in the engine coolant outlet, fresh water pump mounted on engine, fan and fan hub mounted on engine. A reservoir of 50% of radiator capacity to replenish coolant by gravity (as and when required) is also to be provided. (f) Lubricating System: Should comprise of lubricating oil sump mounted on engine, gear driven lub oil pump mounted on engine, lubricating oil cooler-fresh water cooled integral with engine cool out circuit mounted on engine, oil filter lubricating with cap and lubricating oil dip stick for oil level check mounted on engine. The system should be capable of feeding lube oil to the main end & large end bearings, cam shaft, valve rocker gear and all moving parts. (g) Starting System: Should comprise of suitable voltage DC electrical starter mounted on engine, with suitable maintenance free battery of capacity 12 V DC - 02 Nos with suitable AH to be mounted in trays (having rubber insulation) on the main frame. It should have the provision to charge the battery from external sources during static condition and while running of the generator. | |||||||||
| 1.04(h) AC Generator : The generator shall be horizontal and foot mounted,250 KVA, 415 Volts, 3 phase, 4 wire, 0.8 PF, 50 HZ, self excited, self regulated, brushless AC generator, suitable for voltage regulation + 1% , an ambient temperature of 40 to 50° C as per OEM design with IP-23 enclosure class H insulation and temperature rise limited to class H as per following technical details:- (i) Type, Brush less AC Generators and space heater as per OEM design (ii) Output rating 250 KVA (iii) Output Voltage: 415 ± 1% under all loading conditions and with maximum voltage Dip at full load 0.8 PF shall be < 19% as per OEM design. (iv) Output frequency 50Hz ±0.5% up to 0.8 lagging. (v) No of Phases: 3 phase with 01 Neutral (4 wire) (vi) Mounting : Horizontal foot mounted. (vii) Enclosure : Minimum IP-23 / Drip proof and screen protected. (viii) Electronic Automatic voltage regulator with response time < 75 m sec and + range of voltage adjustment. (ix) Class of insulation-'H' (x) Short circuit withstand 3 times rated current for 3 secs and overload withstand capacity for continuous duty with 10% overload capacity for 1 hour in 12 hours continuous running & 150% overload for 30 sec running (xi) Overspeed capacity 1800 RPM for 2 min. (xii) The maximum unbalanced load across phases shall be less than or equal to 25%. | |||||||||
| 1.05NOTE : Following shall be deemed to be included in cost quoted :- (i) Standard Control panel with AMF feature outdoor type with IP-54 for 250 KVA DG set as per OEM design. (ii) Suitable size cement concrete foundation platform of canopy base with height as required at site to mount the generator as per manufacturer's instructions/ recommendations. The cost of foundation bed incl earth work and dismantling existing CC and foundation etc is deemed to be included in the quoted rate. (iii) Connecting cables, from existing panels and connecting cables , cables glands, cable lugs to new panel complete with all necessary accessories. (iv) Install on the foundation, connecting fuel lines, cable etc. (v) Test and commissioning complete. (vi) The cost of control cables from engine Control panel to AMF panel, transportation, installation, testing & commissioning etc shall be deemed to be included in the cost quoted. (j) BASE FRAME: Shall be stand by and fabricated with CRCA sheet metal which shall be suitable to mount the engine, alternator and radiator, channel width of base frame shall be adequate to accommodate anti-vibration pads. | |||||||||
| 1.06(k) ENGINE CONTROL PANEL: Control panel shall be powder coated , weather proof type with PCC3.3 controller or suitable equivalent controller as per OEM design, mounted inside the acoustic,consist of the following. 1.suitable rated switchgear as per OEM design 2. Engine control unit (ECU),3. Current Trasformer set 4. Indicating Lamps 5. Set running & load on set Shall be indoor type manufactured with 14/16 guage CRCA sheet and is powder coated for weather-proof and long lasting finish consisting of alarm, indication and safety ( Over speed,High coolant temperature, low oil pressure, water in fuel, engine common fault low fuel level, low coolant level, emergency stop on enclosure, under frequency, over frequency, under voltage over voltage, over current, over load kw, battery under voltage), microprocessor power command controller, Aluminium busbars with suitable capacity with incoming/outgoing terminals, indicating lamps for 'Load ON' and 'Set Running', instrument fuses duly wired and ferruled , Volt meter, ammeter with selector switches, Frequency meter, energy meter, CTs and 3 Phase indicating lamps, timers etc all as per latest engineering practices.etc. complete all as specified and directed. | |||||||||
| 1.07(l) Standard Control panel with AMF feature for 250 KVA DG set as per OEM design to be errected inside sub-station, Standard Control panel with auto mains failure (AMF) feature complete , floor mounted type, vertical, factory made outdoor type, double door , canopy, fabricated out of CRCA sheet with angle iron base frame, floor mounted, dust and vermine proof, suitable for voltage 415 V Three Phase 4 wire, 50 HZ AC supply, weather proof, with IP-54 protection, with separate hinge door for each compartment & locking arrangement, with back door openable (Screwed), legs grouted in PCC complete including painting with two coats of epoxy powder paint over a coat of primer after under going a rigorous metal treatment process involving alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with aluminium busbar (TPN) of suitable rating, suitable double compression copper cable glands and including provn of the following :- | |||||||||
| 1.08(i) Protection relays as per OEM design/approved make. (ii) Minimum switchgears of capacity 400 A , 4P 36 KA of qty/capacity and suitable rated neutral contractor if required as per OEM design. (iii) Suitable rated resin cast CTs. (iv) Suitable rated inbuilt AVR. (v) In built SMPS based automatic battery charger. (vii) Digital Multifunction meters suitable for RS 485 communication with LAN port hub. Make: Schneider/L&T/ABB/Legrand or OEM approved make. (xi) Suitable capacity copper control cables, necessary indications, hooters, auxilliary contactors, TNC & LVM interlocking etc. (b) BACK-UP PROTECTION :- HRC Fuse for short circuit protection. (c) MICRO PROCESSOR BASED AMF MODULE :- (i) Functions:- (aa) Supply failure timer (ab) Restoration timer (ac) 3 in pulse automatic engine start/stop logic & engine fails to start lockout (ad) Generator voltage ,current & frequency monitoring (ae) Battery Voltage sensing & monitoring (ii) Selector switches & Push buttons (aa) Manual/auto/test selector switch (ab) Engine START/STOP (iii) Metering : Remote monitoring system with GPRS/GSM modem with SIM card and 2 year data charges complete for monitoring all DG set parameters such as Hrs run, fuel level, Engine oil pressure etc complete as per OEM design. (iv) Annuciation (LED Type): (Faults) | |||||||||
| 1.09(aa) Engine fails to start (ab) Low lub oil pressure (ac) High water temperature (ad) Generator over load (ae) Battery Voltage (af) Low fuel level (v) Additional features:- (aa) Continuous reading digital voltmer/Ammeter/freqauency meter (ab) Multifunction meters (ac) Electronic (with counter display)KWH Meter. (vi) Relay consisting of following features. (aa) 3 Phase mains supply voltage sensing (ab) Earth fault (ac) Earth leakage (ad) LED Indications (ae) Engine ON, Load on DG (af) Mains On, Load on Mains (ag) overload (vii) Push buttons (AMF Module by pass mode):- (aa) Engine START/STOP (ab) Geneator contactor CLOSE/TRIP (ac)Mains contractor CLOSE/TRIP (ad) Fault ACCEPT/RESET (viii) Engine Meters:- (aa) Lub oil pressure (ab) Water Temparature (ix) Battery Charger:- SMPS Based automatic float cum boost battery charger with following :- (aa) DC Voltmeter & Ammeter (ab) Selector switch for auto/manual & float/Boost. (x) Bypass switch of suitable rating or bypass system as per OEM design | |||||||||
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
16 Jun 2026, 6:00 pmClosed
GE, Minniebay, Sri Vijaya Puram
GE, Minniebay, Junglighat (PO), Sri Vijaya Puram -744103
8735-PROVN OF DG SET OF CAPACITY 250 KVA AND CONNECTED WORKS FOR NEW NCS AND SETTING UP OF MINI CONFERENCE HALL OF NAI (DOLLYGUNJ) UNDER GE MINNIE BAY, SRI VIJAYA PURAM
2026_MES_763228_2
8735/E8
Open Tender
Civil Works
Item Rate
180 days
GE, Minniebay, Sri Vijaya Puram
Please refer Tender documents.
13 documents required · 13 mandatory
₹500
Yes
GE, Minniebay
₹94,000
Yes
20 Aug 2026
26 May 2026
18 Jun 2026
26 May 2026
16 Jun 2026
2 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, install, test and commissioning of 250 KVA/200 KW DG set diesel engine driven Generating set with alternator out put Voltage 415 Volts +/- 1% at set value of 415 V at a frequency 50HZ +/- 0.5%, suitable for prime duty with STD control panel outdoor type IP-54 consisting of AMF feature to be erected, (NTP for suitable for installing at Minniebay Port Blair, all mounted in acoustic enclosure and Control panel as per manufacturer's design and specification confirming to latest norms of CPCB complete with the following and connected accessories with necessary T&P complete :-
i) Inbuilt DG Fuel tank of minimum capacity for 12 Hrs operation on full load with fuel gauge etc complete all as per OEM recommendations
ii)Battery & Leads
iii)Silencer with pipe line & radiator as per OEM design & recommendations complete as per latest CPCB norms
iv)AVM Pads
v)First Fill of Lube
vii)Acoustic Enclosure
viii)Standard Control Panel( AMF) outdoor type with connected switchgear/relays/meters complete IP-54. | 1 | Each Job | 41,35,000 | ₹41,35,000 |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
8735TENDER.pdf
Tender Documents • 0.90 MB
BOQ_859802.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .