| 1 | L1₹43.8 LAccepted-AOC 121004 | L1 | Accepted-AOC Being a lowest bidder and reasonable. | |
| 2 | L2₹45.9 L+₹1.7 L (3.79%)Rejected-Finance 165 UTTAR KASTODANGA ROAD KOLKATA 700 061 | KOLKATA | KOLKATA | WEST BENGAL | 700061 | L2 | Rejected-Finance Other than lowest. | |
| 3 | L3₹46.4 L+₹2.2 L (4.92%)Rejected-Finance P 45 KHIRODE VIDYA BINOD AVENUE KOLKATA 700003 | KOLKATA | WEST BENGAL | 700003 | L3 | Rejected-Finance Other than lowest. | |
| 4 | L4₹47.4 L+₹3.2 L (7.21%)Rejected-Finance | L4 | Rejected-Finance Other than lowest. | |
| 5 | L5₹48.2 L+₹4.0 L (9.06%)Rejected-Finance 197 PATHAK PARA ROAD KOLKATA 700060 | KOLKATA | KOLKATA | WEST BENGAL | 700060 | L5 | Rejected-Finance Other than lowest. |
Tender Value
₹39.5 L
EMD Value
₹79,000
Closing Date
1 Nov 2024, 6:00 pmClosed
GE (FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
COMPREHENSIVE REPAIR AND MAINT OF HRDC, 236 ENGR DET, COMD JCOS MESS, ECSR JCOS MESS, DHOBI GHAT AND HRI OUTSIDE FORT WILLIAM UNDER GE (FW) KOLKATA
2024_MES_678109_1
8307/E8
Open Tender
Civil Works
Item Rate
270 days
GE (FW) Kolkata
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (FW) Kolkata
₹79,000
Yes
16 Dec 2024
4 Oct 2024
2 Nov 2024
4 Oct 2024
1 Nov 2024
17 Oct 2024
Amount
(B/R PORTION) S&F in repair Chromium plated brass Pillar tap fixed to wash hand basin, etc. complete all as specified and as directed.(Make :- Prayag)
S&F in repair 15mm CP bib taps, cast copper alloy fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.(Make :- Prayag)
S&F in repair Chromium plated brass two way Bib cock with wall flange fixed to 15 mm bore of Iron pipe complete all as specified and directed. Make : Ess Ess 203 G or equivalent (Make :- Prayag)
S&F in repair brass chromium plated shower rose 125mm size and 9" long with or without swivel joints any size, including fixing to steel pipe complete all as specified and directed by Engineer-in-Charge.(Make :- Prayag)
S&F in repair brass CP 15 mm mixer for mixing hot & cold water screwed down for iron pipes etc complete all as specified and directed by Engineer-in-Charge.(Make :- Prayag)
S&F in repair Stop valve / angle valve cast copper alloy chromium plated 15mm dia, screwed down, high pressure with capstan handle, screwed both ends for iron pipes or for unions and fixed with long shank and cup (concealed type) complete all as specified and directed by Engineer-in-Charge..(Make :- Prayag)
S&F in repair Stop valve/angle valve cast copper alloy chromium plated 15mm dia, screwed down, high pressure with capstan handle, screwed both ends for iron pipes or for unions and fixed fancy type chromium plated complete all as specified and directed by Engineer-in-Charge..(Make :- Prayag)
S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed by Engineer-in-Charge..(Make :- Prayag)
S&F in repair brass CP tubular Towel rail 600mm long and 20mm dia with chromium plated brass screws and wooden/plastic cleats complete all as directed.(Make :- Prayag)
Repair to CP brass item of Bib tap, Stop cock, Pillar tap, angular cock, shower rose, hand shower, health faucet etc of 15mm size including replacement of washer/spindle if required in day to day maintenance.
S&F in repair Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC connection 450mm long fixed with 15mm GI pipe complete all as specified and directed (Make: Prayag ).
All as per Ser Item No 13 but 600mm long.
S&F in repair Plastic seat cover in white or any colour of EWC with flat bottom incl hanging device complete all as specified and directed
S&F in repair 32 mm bore CP bottle trap of PTMT having minimum water seal of 25mm .(Minimum weight 32mm-260gms/40mm-270 gms) connected to pipe complete all as specified and directed
S&F in repair PVC flushing cistern 9 to10ltrs capacity fixed with GI pipe incl all fittings with PVC down pipe complete all as directed (Make: Cera/ Commander)
Repair only to flushing cistern incl cleaning and replacement of washer and syphonage of suitable size if required complete all as specified and directed.
Taking up or down steel water tubing 15 mm bore incl connection , cleaning etc
.All as per Ser Item No 19 but 20 mm bore
All as per Ser Item No 19 but 25mm bore.
S&F tubes 15mm bore medium grade galvanised with all fittings and fixed complete to wall and ceiling or laid in floors.
.All as per Ser Item No 22 but 20mm bore.
All as per Ser Item No 22 but 25mm bore.
Refixing old steel tubing 15mm bore and connection in new or old position(wall, ceiling, floor etc.).
.All as per Ser Item No 25 but 20mm bore.
All as per Ser Item No 25 but 25mm bore.
S&F in repair of 500 ltrs capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position including suitable float valve fixed with GI pipe complete all as specified and directed.
S&F in repair of 1000 ltrs capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position including suitable float valve fixed with GI pipe complete all as specified and directed.
S&F in repair of 2000 ltrs capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position including suitable float valve fixed with GI pipe complete all as specified and directed.
Disconnecting of existing tanks 500 ltr capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) etc, compete all as directed.
Disconnecting of existing tanks 100 ltr capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) etc, compete all as directed.
Dismantling of floor hearth, wall tiling incl cement mortar bedding( but not backing) removing of serviceable tiles to store and rubbish off the premises complete all as specified.
M&L for 40mm thick PCC 1:2:4 type B-1(using 20mm graded stone aggregate) as in sub base of floor complete all as specified and directed.
M&L joint free coloured tiles 7-8mm thick area of each tiles exc 0.11 sqm but n.exc0.18sqm (400X400X7-8mm),as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick screed bedding in CM 1:6.
M&L coloured glazed ceramic tiles in vertical surfaces 450X300X7-8mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 10mm thick backing coat in CM 1:4 complete all as specified and directed.
Repair/refixing of WHB with new brackets fixed on wall complete all as directed.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key and scrubbing down with water complete All as specified and as directed.
M&L 15mm thick cement plaster on brick or concrete walls finishing fair and even in CM 1:4 complete all as directed.
M&L 10 mm thick cement plaster on brick or concrete surfaces without using extra cement finishing fair and even in CM 1:6 including necessary scaffolding complete all as directed.
M&L for rendering 5mm thick on fair faces of brick work or concrete ceiling surfaces in CM 1:3 finished rendering is to be finished even and smooth without using extra cement complete all as specified and directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
ditto all as per item above but one coat etc complete all as spd and as directed.
M&L Preparing new Plaster Surfaces of Wall and applying two Coats of oil bound distemper complete all as specified and as directed.
M&L Preparing new plaster surfaces of ceiling and applying two Coats of oil bound distemper complete all as specified and as directed.
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete with plastic water closet seat cover white closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinges device including connecting to flush pipe.
S&F in repair Wash basins, Vitreous China (flat back or angle back type) of size 630 x 450mm, including cutting for and pinning in ends of brackets or erecting stand, brackets but exclusive of waste pipe etc complete all as spd and as directed.
S&F in repair 40mm dia PVC pipe with bend complete fixed on walls, ceilings and floors incl GI/PVC clamps, bends sockets etc incl taking down U/S old PVC pipes complete all as specified and directed( Make: Supreme)
M&L for small repair of hinges for door and window, adjustable for sliding door bolts, tower bolts, repair of handles, mortice locks etc for similar type of works complete all as directed by Engr-in-charge (rate incl welding where ever reqd.
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) area exc 1.5 Sqm and n.exc.4.00 Sqm each wooden all as directed.
Taking down shutters of any description exc 1.00 sqm but n.exc 2.00 Sqm each all as directed.
S&F for 2nd class HW, plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, moulded or chamfered, put together with glue, pinned at joints complete all as directed.
S&F 30mm thick 2nd class hard wood glazed & skeleton shutters, open rebated and prepared to received glass, gauge etc.(without sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc, size of members of shutters as specified in SSR Part-I section 8, clause 8.20(a) complete all as directed.
S&F Factory made 30mm thick with 2nd class hard wood, rail and style factory made plain framed panelled shutter with lock, rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail & style as per IS:1003(Part-I) kiln seasoned and chemically pressure treated.
Taking down PVC door shutter with PVC chowkats including all fittings area exc 1.00 Sqm but n.exc 2.00 Sqm all as directed.
S&F Factory made solid PVC door frame (chowkhat) of size 50mmx47mm made out of 5mm plain colour wood grain PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with printed sheet reinforced with MS square tube, S&F in opening as per specification & drg as per manufacturer instructions. Make : Kumar Arch Tech Pvt Ltd or equivalent
s& f Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded prelim PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing
S&F 100mm butt hinges stainless steel medium weight
All as per Ser Item No 58 but 75mm.
S&F aluminium handle, cast type anodised 125mm size all as directed.
All as per Ser Item No 60 but 150mm.
S&F 150mm aluminium anodised barrel tower bolts of extruded section.
All as per Ser Item No 62 but 200mm long all as directed.
S&F 300mm aluminium, anodised sliding door bolt with hasp, staple(bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy all as directed complete all as directed.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aparture 1.40mm and fixed with stainless steel wire staples complete all as directed.
All as per Ser Item No 65 but fixed in repair.
Hacking out old broken glass (any thickness and size or quality) from metal frames glazed with putty or fixed with beads .
S&F 3 mm thick ordinary quality sheet glass/frosted glass and glazing with oil putty in square n.exc. 0.5 Sqm in each pane complete all as directed.
All as per Ser Item No 68 but fixed in repair.
Taking down steel window/ventilators of any size including grill/guard bars and removing to store complete all as directed.
S&F powder coated anodised aluminium doors frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified.
S&F aluminium anodised powder coated for doors, windows, ventilators and partition with one or more rebate (Minimum thickness of powder coating 50 micron) and Three track with 1.80 mm thick channel section and shutter frame thickness 1.65 mm without sash bars, Aluminium section weighing 0.55 kg/mtr including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. Complete all as specified and directed. Note:- 1.Size of window shall be as per site requirement. 2. Glass & wire cloth shall be measured separately.
S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineering-charge.
S&F 4mm thick ordinary quality sheet glass/frosted glass and glazing with oil putty in square n.exc. 0.5 Sqm in each pane complete all as directed.
Preparing new steel surface of any description, over 10 cm in width or girth, not otherwise described and painting with two coats of synthetic enameled paint over a coat of red oxide primer.
Preparing new surface of wood or wood based material of any description and in any position not otherwise described n.exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as directed.
S&F 20mm dia fancy type Harrison rails (Curtain rod) mild steel, chromium plated including fixing brackets, stops, rollers et fixed on wall sample as approved by GE complete all as directed.
M&L in repair 18/19mm thick pre-laminated particle board as in cup board shutter double leaf one side decorative of sheds and other side balancing white lamination. All edges properly sealed with 5mm thick 2nd class hard beading fixed with water resistant adhesive except rebate side which shall be of 25mm thick as in repair complete all as directed.
S&F in repair drawer knobs 40 mm dia of brass polished fixed with nut screw and washer all as directed.
M&L in repair for 300mm MS ordinary helical springs including roller and roller plate complete all as directed.
M&L in repair19 to 20 mm thick black/coloured granite machine cut laid over 10mm thick screed bed in cm 1:4 and jointed with grey or coloured cement to match with admixture of pigment to match the shade of granite including cutting polishing all as specified and as directed.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth
Providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth
M&L Preparing old decorated Plaster Surfaces of Wall washing, rubbing down and stopping of distempered and painted surfaces of wall as and applying one Coat of oil bound distemper complete all as specified and as directed.
M&L Preparing old decorated plaster surfaces of ceiling and applying One Coat of oil bound distemper complete all as specified and as directed.
M&L Preparing old Wooden Surfaces of any description not otherwise described over 10 Cm width or girth and applying One Coat of Synthetic Enamel Paint (First quality), complete all as specified and as directed.
M&L Preparing old Painted Steel Surfaces over 10 Cm width or girth not otherwise described and applying One Coat of Synthetic Enamel Paint (First quality), complete all as specified and as directed.
Taking down plants and vegetation from walls upto roof level by means of cutting Holes in Brick Walls, built in Cement Mortar of 150mm depth making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required n exc 150 sq.cm in superficial area, complete all as specified and as directed.
M&L for cleaning of inaccessible areas of roof including parapet walls upto 0.50 metre height, removal of vegetation growth, including uprooting, if required and repair to broken/chipped off plastered surfaces with cement mortar 1:4, mixed with water proofing compound @ 3% by weight of cement, finished fair and even including necessary ladder/scaffolding complete all as specified and directed. (NOTE: Water Proofing Compound shall be measured and paid separately)
M&L for cleaning of outer surfaces of down take pipes, any type, treating minor leakages at joints, clearing of vegetation, scraping of algae growth with wire brush, chipping of damaged plaster at the joints (area not exc 0.50 sqm) and making good with cement mortar 1:4 duly mixed with water proofing compound @ 3% by weight of cement and applying one coat of tartaric acid on dry finished plaster surface including necessary ladder/scaffolding complete all as specified and directed.
M&L for anti termite treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area all as specified and directed.
M&L for anti termite treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface area all as specified and directed.
M&L for anti termite treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall all as specified and directed.
M& L for water proof film coating (elastic and breathable),in two layers (as per manufacturers instructions) ,for patch repair of damp and repaired wall over old or new plastered surfaces of walls including preparation of surfaces complete all as specified and directed.( Make:- Dr Fixit, Sureseal or equivalent product in other makes of chemical/ paint Specified in tender).
M& L for providing and applying shall urethane BTD,UV resistant, high performance, water based, cold applied, single component elastomeric in-situ liquid membrane for waterproofing conforming to ASTMC836a and ASTM D 6083 on top of concrete roof in two coats @9. kg/10 sqm for 500 microns DFT. one coat of self priming of elastomeric water proofing liquid (dry, film thicknesration shall be carried out s of complete application/system as per direction of engr-in-charge. the operation shall be carried out after scrapping and properly cleaning the surface remove loose particles with wire brushes, complete in all respect as per the direction of engineer in charge.
Mel for painting of exposed brick surface including surface preparation by hand operated or power operated tools i.e scrappers, wire brushes, sand papers, pumice stone etc. Painting should be done in two coats of thickness of 100 microns each by anti corrosive bituminous black paint tank mastic 100 or similar conforming to IS:9862 as approved by Engr-in-charge @2.50 ltr/10 sqm with interval of 8 hrs between two coats. The rate as inclusive of all contractors own labour, materials, tools and plants, leads, lifts, transportation, taxes, octroi etc complete as per approved drawing and as directed by the Engr-in-charge.
S & F for extra for addition of polymerised acrylic polymer with 47% solid content shalicrete 47 of STP or similar make as approved by engr-in-charge in cement plaster/mortar in weight ratio of 50:5 for cement and polymerised acrylic polymer used in cement mortar as per directions of Engr-in-Charge.
M& l application &finishing with UV resistant elastomeric anti-carbonation exterior acrylic wpt coating with 2 coats of shalicryl ( R) 215 of M/S STP ltd or similar as approved by Engr-in-charge @3.08 ltr/10 sqm at all locations & levels, prepared and applied as per manufacturers specifications including preparation of surface by filling of pin holes with cement putty, honey combing, grinding of edges (if required any) etc. complete. grinding of excess loose materials in grooves of segment joint and filling of putty in these grooves to make the entire span length monolithic. The coating should be applied over a primed coat of shall prime (R ) WB of M/S STP ltd or similar as approved by engr-in-charge@ 1.25 ltr/10 sqm diluted in the ratio of 1:0.5 to achieve even shade and colour, all complete as per manufacturers specifications as per direction s of Engr-in-charge. The rate is inclusive of all contractors own labour.
Dismantling of 100mm dia cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches/walls including all fittings and necessary scaffolding upto any height of bldg, all as specified and as directed.
S&F for 100 mm dia Cast iron sand cast soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors etc complete all as specified and directed.
S & F 100 mm bore Cast iron (sand cast) soil, waste and vent pipes in any length with or without ears with cement joints, fixed to walls etc complete including necessary scaffolding upto any height Building all as specified and directed.
S&F for repair 100mm PVC/ CI Bore of pipe for Stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof including necessary scaffolding upto any height building all as specified and directed.
S & F for CI bend 100 mm bore with oval access door.etc complete including necessary scaffolding upto any height all as specified and directed
S & F for bend / Tee 100 mm bore etc complete including necessary scaffoliding up to any height of building all as specified and directed.
S & F for CI branch piece single (equal or unequal) for 100 mm bore pipe etc complete including necessary scoffolding to any height of building all as specified and directed.
S&F for 100 mm bore Cast iron cowls including necessary scaffoliding up to any height of building all as specified and directed.
S & F in repair 100 mm bore cast iron rain water socket pipes with cement joints without ears etc fixed to wall complete including necessary scoffolding to any height of building all as specified and directed.
S & F in repair 100 mm bore CI rain water bends or elbow square etc complete including necessary scaffolding to any height of building all as spd and as directed
Taking down 100/75mm PVC (SWR) Soil /RWP pipe including all fittings such as bends, shoe etc., complete taking out from foul places including necessary scaffolding upto any height, complete all as specified and as directed.
S & F in 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls etc complete including necessary scaffolding to any height of building all as specified and directed. Make : supreme
S & F 110 mm bore PVC bends etc complete including necessary scaffolding to any height of building all as specified and directed.
S&F 110 PVC (SWR) brance piece, single (Single Y) equal or unequal including necessary scoffolding to any height of building all as specified and directed.
S&F110 PVC (SWR) Junction single (Single T) equal or unequal including necessary scoffolding to any height of building all as specified and directed.
S & F in 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls etc complete including necessary scaffolding to any height of building all as specified and directed. Make : supreme
S & F 75 mm bore PVC bends etc complete including necessary scaffolding to any height of building all as specified and directed.
S&F 75 PVC (SWR) brance piece, single (Single Y) equal or unequal including necessary scoffolding to any height of building all as specified and directed.
S&F75 PVC (SWR) Junction single (Single T) equal or unequal including necessary scoffolding to any height of building all as specified and directed.
(E/M PORTION) Taking down carefully old unsv copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, sunken type box etc. and removing materials to store for keeping in safe custody for reuse at site or for taking credit and making good to disturbed surfaces of walls, floors etc with its original specification complete all as specified and directed by Engr-in-Charge.
Material and labour for point wiring for the followings with 1.5 Sqmm single core, PVC FRLSH insulated unsheathed, multistranded copper conductor drawn through and including PVC casing and capping/ Conduit including necessary accessories like bends, tees, PVC square and elbow etc fixed on wall/ceiling with 1.5 Sqmm PVC FRLSH insulated unsheathed multi stranded copper conductor cable as earth continuity (green in colour) connected to common earth dolly including sunken type pressed steel terminal boxes of suitable sizes with plastic laminated white/coloured top sheet cover 3 mm thick including making good all disturbed surfaces to match the existing complete all as specified and directed as below :-
(a) One light/fan point controlled by one, one way switch.
(b) One bell point controlled by one push button switch.
(c) One 3 Pin 5 Amps socket out let point on independent board.
(d) One 3 Pin 5 Amps socket out let point on same board alongwith other suitable switches.
All as per item above here-in-before but using 2.5 sqmm PVC FRLSH insulated copper conductor wire for connecting 15A socket on independent board complete all as specified/directed.
Supply and fixing of switch piano flush type 240 Volts 5 Amps, SP, one way complete all as specified/directed.
Supply and fixing of bell push piano flush type one way 240 Volts 5 Amps all as specified/directed.
Supply and fixing of switch socket outlet combination 3 Pin,5 Amps, 240 volts flush type (non shuttered) complete all as specified/ directed.
Supply & fixing of socket outlet 2 in 1,3 pin 5 Amps 240 Volts flush type (non shuttered) complete all as specified / directed.
Supply and fixing of switch socket out let combination multipurpose 3 pin, 15/16 Amps and (with 3 pin 5 Amps outlet also) flush type (non shuttered) complete all as specified/directed.
Supply and fixing of bell electric, 240 Volts, single pole complete all as specified and directed.
Supply & fixing of ceiling fan regulator electronic, Deluxe, rotary, step type, 120/280 volts as specified/directed.
Supply and fixing of Bulb holder angular PVC/Polycarbonate suitable for batten fittings complete all as specified/directed.
Supply and fixing of ceiling rose surface PVC/Polycarbonate, 65x50 mm two to three terminals complete all as specified/directed.
Supply and fixing LED lights fitting 1x 20 W, 220V, AC decorative box with aluminum housing type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. Make Surya
Supply and fixing LED lights fitting 1x 10 W, 220V, AC decorative box with aluminum housing type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. Make Surya
S & F in Replacement for fittings with twin core PVC insulated and overall PVC sheathed cable with stranded aluminium conductor 1100 volts grade of size 4 sqmm including taking down old unserviceable wiring complete all as specified and directed.
Supply and fixing in repair of switch piano flush type 240 Volts 5 Amps, SP, one way, fix in repair including taking down old unsv complete all as specified/directed.
Supply and fixing in repair of bell push piano flush type one way 240 Volts 5 Amps, fix in repair including taking down old unsv complete all as specified/directed.
Supply and fixing in repair of switch socket outlet combination 3 Pin,5 Amps, 240 volts flush type (non shuttered) ,fix in repair including taking down old unsv complete all as specified/ directed.
Supply & fixing in repair of socket outlet 2 in 1,3 pin 5 Amps 240 Volts flush type (non shuttered),fix in repair including taking down old unsv complete all as specified / directed.
Supply and fixing in repair of switch socket out let combination multipurpose 3 pin, 15/16 Amps and (with 3 pin 5 Amps outlet also) flush type (non shuttered), fix in repair including taking down old unsv complete all as specified/directed.
Supply & fixing in repair of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet including taking down old unsv complete all as specified and directed.
Supply and fixing in repair of bell electric, 240 Volts, single pole, fix in repair including taking down old unsv complete all as specified and directed.
Supply and fixing in repair of Bulb holder angular PVC/Polycarbonate suitable for batten fittings, fix in repair including taking down old unsv complete all as specified/directed.
S&F Fan step regulator, 120W - 2 module
S&F Fan capacitors 2.5 mfd complete
Supply and fixing in repair of MCB SPN DB 8 way double door,IP-43 protection, isolated neutral bar, insulated busbar assembly, mechanical impact strength of IK08 complete incl taking down old unsv all as specified and directed by Engr-in-charge.
Supply and fixing in repair of MCB SPN DB 4 way double door,IP-43 protection, isolated neutral bar, insulated busbar assembly, mechanical impact strength of IK08 incl taking down old unsv complete all as specified and directed by Engr-in-charge. Make : L&T/Legrand
Supply & fixing in repair of MCB TPN 63 Amps 'B' Series 10 KA 415 volts incl taking down old unsv complete all as specified/directed.
Supply & fixing in repair of MCB SPN 40 Amps 'B' Series 10 KA 240 volts incl taking down old unsv complete all as specified/directed.
Supply & fixing in repair of MCB SP 6-32 Amps 'B' Series 10 KA, 240 volts incl taking down old unsv complete all as specified/directed.
Supply and fixing in repair of single Pole & Neutral enclosure with 2 pin and earth plug & socket for incorporating with single pole 20 Amp SP MCB all as complete including taking down old unsv one and directed by the Engineer-in-charge.
Supply and fixing in repair of AC short circuit protection motor starter 25 Amps capacity, 230 Volt with MCB DP 25 Amps, plug top & socket complete 6 M including taking down old unsv complete all as specified and directed. Make Havells
Supply and fixing in repair LED lights fitting 1x 20 W, 220V, AC decorative box with aluminum housing type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. Make Havells Cat No LUMILINE + BS20WLED840SPCSS or equivalent
Supply and fixing in repair LED lights fitting 2X2 light fittings of 36 W, integrated with PIR sensor for autonomous operation 220V, AC with aluminum housing type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. Make Havells Cat No VENUSNEOHE2X2R36WLED830PIRSENSOR or equivalent
Supply and fixing in repair LED lights fitting 1x 10 W, 220V, AC decorative box with aluminum housing type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. Make Havells Cat No LUMILINE + BS10WLED840SPCSS or equivalent
S&F in repair LED bulb of 09 W complete. Make bajaj/Magic or equivalent
Supply and fixed in repair PVC terminal Rectangular boxes of suitable size with 3 mm thick PVC /plastic laminated sheet, top cover suitable sizes of brass screws and washers etc. for mounting switches, sockets, regulators etc of size 100mmx100mmx50mm deep depends on the no of switch and socket complete all as specified and directed.
Material & labour for Sub main wiring with two runs of single core 4 Sqmm (Nominal Area) FRLSH PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 volts grade drawn through and including PVC casing capping of adequate size fixed on surface of wall/ceiling with all necessary fittings and accessories and 1 run of FRLSH PVC insulated and unsheathed insulated single core cable with multi slandered copper conductor of size 4 Sqmm as earth wire (green in colour) run through casing capping and connected common earth dolly including taking out the old sub main wiring for connection to DBs/dolly shall be deemed to be included in this item and shall be measured as one run complete all as specified and directed.
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
MS AP CONSTRUTION AND CO (BID ID -3151267)
UNIVERSAL TRADING CENTRE (BID ID -3151183)
JOY-EN-JOY (BID ID -3150534)
JAGATMATA ENTERPRISE (BID ID -3149859)
DEB AND COMPANY (BID ID -3149948)
MS JYOTI INDUSTRIES (BID ID -3150375)
MS HORIZEN (BID ID -3150255)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .