Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 LAccepted-AOC 87 KALUA PAUL PARA JOKA KOLKATA 700104 | KOLKATA | 24 PARAGANAS SOUTH | WEST BENGAL | 700104 | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹7.9 L+₹1.0 L (14.9%)Rejected-Finance | L2 | Rejected-Finance bidder is not L1 | |
| 3 | L3₹8.5 L+₹1.6 L (23.3%)Rejected-Finance | L3 | Rejected-Finance bidder is not L1 |
Tender Value
Refer Docs
EMD Value
₹19,794
Closing Date
5 Feb 2025, 2:00 pmClosed
Executive Engineer-I,CKHED,PWDte.
Central Kolkata Health Electrical Division, P.W.Dte. P-5, CIT Road, 2nd Floor, Moulali, Kolkata
Special repair and renovation of Electrical Installation Work at Beniapukur Main Hostel in Calcutta National Medical College.
2025_WBPWD_803742_1
WBPWD/EE-I/CKHED/eNIT104/24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
40 days
CNMC
Please refer Tender documents.
3 documents required · 3 mandatory
₹19,794
Central Kolkata Health Electrical Division
11 Apr 2025
20 Jan 2025
7 Feb 2025
20 Jan 2025
5 Feb 2025
27 Jan 2025
27 Jan 2025
Amount
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] Average run 08 meter.E-14/2c
Dismantling the existing old wiring,MS box, Electrical Panel installed in Pump Room fan &tube light from its position and good quality items will be refixing (fan & tubelight fittings etc) and damage materials will send to Godown of NMCH Subdivision.(In entire Main Hostel Campus )
Supply & delivery of Single LED tube light fittings. (Make :- Philips -TMC 502 1xT-LED 22W). incl S&F 1x 18/20 watts 4 ft LED tube lamp (Make:- Philips, Cat - Essential LEDTube 1200mm 20W865 T8 IND I / WIPRO / Lighting Technology.)
Supply & delivery of Double LED tube light fittings. (Make :- Philips -TMC 502 2xT-LED 22W). incl S&F 2x 18/20 watts 4 ft LED tube lamp (Make:- Philips, Cat - Essential LEDTube 1200mm 20W865 T8 IND I/ WIPRO / Lighting Technology.)
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length, as per GS.
S& D 48 " sweep 230 V,1-Ph ,AC Ceiling Fan inclu all access.The Capacitor of the fan must be P-2 type brust proof & must have safety wire directly linked from fan hook to stator of the fan.(Make-CG HS plus /Usha Striker Plus /Orient Energy Plus having similar specification) S & D 48" Sweep,230 V,1-ph ,AC ceiling fan incl all access.
Fixing only ceiling fan complete with blades , canopy as per G.S.
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections
Supply & Fixing heavy duty exhaust fan(Make-EPC) of following sizes incl. louver shutter after making hole in wall and mending good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection. a) 12" dia Exhaust fan.
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 175x100x65mm MS (16SWG) powder coated switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. E-6/22
Supplying & fixing 250 V 2 nos. 5 Pin 6 A flush type plug socket with 6 A Piano key type (Anchor make) switch on 175x100x65mm size (16SWG) powder coated MS box with bakelite top cover and earthing attachment incl. S&F sheet metal box [16 SWG] with 3mm thick bakelite top cover.
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint.I-2/16 a
Supply of 80 watt LED flood light luminarie(Make:Crompton . cat no.LFL-80-CDL/ 60) or equivalent model of Wipro with high pressure die cast aluminium housing, , toughened flat glass cover offering IP-66 ingress protection incl. (80 Watt) allocation : 3 Nos in backside of Main Hostel & Gas Bank & 2 Nos In PWD office in NMCH(WIPRO / Lighting Technology.)
Supply & Fixing of MS Angle size of 40X40 X5 with Suitable enamel paint with length of 4 ft ,one side of the angle grouted in wall or fixing with fasterners and another side of angle consist of 3 nos hole for fixing of above mention flood Light .Fixing of the MS Angle will be 18 ft above from ground Level .(For Student play ground ) (NUT BOLT Should be Stainless Steel type)
Supply & Fixing of L shaped MS Angle size of 40X40 X5 with Suitable enamel paint of length of 2 ft & 1.5 ft ,One side(i.e 1.5 ft lenght will grouted in wall) and another side (i.e 1.5 ft lenght will grouted in wall) of angle consist of 3 nos hole for fixing of above mention flood Light .Fixing of the MS Angle will be 10 ft above from ground Level .(for back side of Main Hostel ) (NUT BOLT Should be Stainless Steel type)
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required
(i) 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC (for out door light)
(ii) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC (for power plug)
(iii) 2x 84/0.3 (6 sqmm) & 1x 56/0.3 (4 sqmm) in 20mm dia
Supply & Laying of 2 core 10sqmm XLPE/A Al cable. cable on wall/ surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip)Wire, making holes etc. as necy. mending good damages and painting as directed by EIC.
S&F compression type cable gland complete with brass gland, brass ring & rubber ring for dust and moisture proof entry of 2 core 10sqmm XLPE/A Al cable as per GS.
Finishing the end of 2 core 10sqmm XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials as to GS
Supplying and fixing 250 V, 2+12 way SPN MCBDB(Similar to Legrand Cat no.-607712) with SS enclosure double-door(Metallic door with acrylic) with IP-43 protection with 40 Amp MCB(30 mA) as incomer and 12 nos SPMCBs ('C' Curve, 10kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.(Make-Legrand/L& T /Schneider )( For Canteen Area)
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level incl. excavation approx 1mtr3 of soft soil & restoring surface duly rammed By ISI-Medium GI pipe as directed by EIC.
Extra for connecting the equipments to Earth busbar including S & F GI 08 SWG (Hot Dip) wire of size as below on wall/floor with staples buried inside the wall/floor as required and making connection to equipments with bolt nuts washers cable lugs etc as required and mending good damages
Supplying and fixing 415 V Four Pole 160A TPN SFU with sheet steel enclosure on flat iron frame on wall with nuts bolts etc incl S 7 F 3 nos DIN type HRC fuse as per rating.(D-3,4a) [Make :- Schneider/ABB/Legrand/Siemens/L-K]
Supply & Laying of 1.1 KV Grade 95sqmm XLPE insulated and PVC sheathed aluminium conductor cable ( Armoured ) with 2 Nos 8 SWG G.I wire on wall with S/F MS shaddle incl. making connections as per direction of EIC.of following size as to GS.
Supplying and fixing compression type gland for 1.1 KV Grade 95sqmm XLPE cable complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below For 4 core [F4,7]
Rate should be quoted incl. of all taxes and cess.
Defect Liability period : 1 year
R L COMPANY (BID ID -6074803)
THE CITY ELECTRIC CO. (BID ID -6085598)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .