Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.2 LAccepted-AOC 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L1 | Accepted-AOC L1 | |
| 2 | L2₹22.8 L+₹2.1 L (10.0%)Rejected-Finance NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹23.8 L+₹3.1 L (14.8%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹24.3 L+₹3.5 L (16.9%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹26.6 L+₹5.9 L (28.3%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
15 Sept 2020, 6:00 pmClosed
GE UTILITIES
GE UTILITIES UDHAMPUR PO GARHI PIN 182121 UDHAMPUR
Special Repair to External Electric Network and connected wks at CP Colony and PB Enclave and Upgradation of Transformer at HQ EW Bde under GE Utilities Udhampur
2020_MES_369373_1
GE/U-56/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE UTILITIES UDHAMPUR
₹56,000
Yes
26 Oct 2020
14 Aug 2020
17 Sept 2020
14 Aug 2020
15 Sept 2020
1 Sept 2020
Amount
Taking out the existing unserviceable rusted LT panel board alongwith busbar, MCCBs etc of any size/capacity including disconnection, breaking PCC foundation etc.and disposed off as specified and directed by Engr-in-Charge.
Supply, installation, testing and commissioning of outdoor type,weather proof, cubicle LT Panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 bocks of size 15x15x20 cm, front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof, IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments: -
Supply, installation, testing and commissioning of outdoor type,weather proof, cubicle LT Panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 bocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :-
Supply, installation, testing and commissioning of outdoor type,weather proof, cubicle LT Panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 bocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :-
Supply, installation, testing and commissioning of outdoor type,weather proof, cubicle LT Panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 bocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :-
(a) Aluminium bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 600 amps for Phases neutral - 01 set (b) Panel indicating lamp neon/LED type (Red ,Yellow & Blue) with lamp holders - 03 Nos (c) Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job Incoming :- (a) MCCB 4 pole , Ics=100%Icu- 35/36 KA, 415 Volts, 400 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 No. Outgoing :- (a) MCCB 4 pole , Ics=100%Icu- 35/36 KA, 415 Volts, 320 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 No. (b) MCCB 4 pole , Ics=100%Icu- 25/26 KA, 415 Volts, 100 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 No. (c) PCC 1:2:4 type B-1 for grouting 4 legs of feeder pillar box. Note: - Various feeder shall be indicated by 50 mm high letter in white synethetic enamel paint.
Supply, installation, testing and commissioning of outdoor type,weather proof, cubicle LT Panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 bocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete, suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :-
(a) Aluminium bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 600 amps for Phases and neutral - 01 set (b) Panel indicating lamp neon/LED type (Red ,Yellow & Blue) with lamp holders - 03 Nos (c) Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job Incoming :- (a) MCCB 4 pole , Ics=100%Icu- 35/36 KA, 415 Volts, 400 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 No. Outgoing :- (a) MCCB 4 pole , Ics=100%Icu- 25/26 KA, 415 Volts, 100 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -04 Nos. (b) PCC 1:2:4 type B-1 for grouting 4 legs of feeder pillar box. Note: - Various feeder shall be indicated by 50 mm high letter in white synethetic enamel paint.
Supply, installation, testing and commissioning of outdoor type,weather proof, cubicle LT Panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 bocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete, suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :-
(a) Aluminium bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 600 amps for Phases and neutral - 01 set (b) Panel indicating lamp neon/LED type (Red ,Yellow & Blue) with lamp holders - 03 Nos (c) Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job Incoming :- (a) MCCB 4 pole ,Ics=100%Icu- 35/36 KA, 415 Volts, 400 Amps ,with thermal adjustable and fixed magnetic setting with extended terminals -01 Nos. Outgoing :- (a) MCCB 4 pole ,Ics=100%Icu- 35/36 KA, 415 Volts, 200 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 No. (c) MCCB 4 pole ,Ics=100%Icu- 25/26 KA, 415 Volts, 100 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -03 Nos. (b) PCC 1:2:4 type B-1 for grouting 4 legs of feeder pillar box. Note: - Various feeder shall be indicated by 50 mm high letter in white synethetic enamel paint.
Supply, installation, testing and commissioning of outdoor type,weather proof, cubicle LT Panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 bocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :-
(a) Aluminium bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 300 amps for Phases neutral - 01 set (b) Panel indicating lamp neon/LED type (Red ,Yellow & Blue) with lamp holders - 03 Nos (c) Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job Incoming :- (a) MCCB 4 pole , Ics=100%Icu- 35/36 KA, 415 Volts, 200 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 Nos. Outgoing :- (a) MCCB 4 pole , Ics=100%Icu- 25/26 KA, 415 Volts, 100 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 Nos. (b) MCCB 4 pole , Ics=100%Icu- 18 KA, 415 Volts, 63 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 Nos. (c) PCC 1:2:4 type B-1 for grouting 4 legs of feeder pillar box. Note: - Various feeder shall be indicated by 50 mm high letter in white synethetic enamel paint.
Supply, installation, testing and commissioning of outdoor type,weather proof, cubicle LT Panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 bocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :-
Supply, installation, testing and commissioning of wall mounted support type, weather proof, LT Panel board made out of 3.15 mm thick CRCA steel sheet front side openable, double door openable , lockable / openable by keys from front side having hromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. The panel should have clit/hanging arrangement on the wall. The panel shall be suitable to accomodate the following equiptments :-
(a) Alluminium Bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 300 amps for Phases neutral - 01 set (b) Panel indicating lamp neon/LED type (Red ,Yellow & Blue) with lamp holders - 03 Nos (c) Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job INCOMING: - MCCB 4 pole , Ics=100%Icu- 25/26 KA, 415 Volts, 200 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 No. OUTGOING: - MCB SPN 63 A - 16 Nos
Supply, installation, testing and commissioning of outdoor type,weather proof, cubicle LT Panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 bocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :-
(a) Aluminium bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 600 amps for Phases and neutral - 01 set (b) Panel indicating lamp neon/LED type (Red ,Yellow & Blue) with lamp holders - 03 Nos (c) Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job Incoming :- (a) MCCB 4 pole , Ics=100%Icu- 35/36 KA, 415 Volts, 400 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 Nos. Outgoing :- (a) MCCB 4 pole , Ics=100%Icu- 35/36 KA, 415 Volts, 250 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 Nos. (b) MCCB 4 pole , Ics=100%Icu- 35/36 KA, 415 Volts, 200 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 Nos. (c) PCC 1:2:4 type B-1 for grouting 4 legs of feeder pillar box. Note: - Various feeder shall be indicated by 50 mm high letter in white synethetic enamel paint.
Taking out the existing unserviceable rusted junction box board alongwith busbar, etc of any size/capacity including disconnection, breaking PCC foundation etc.and disposed off complete all as specified and directed by Engr-in-charge.
M&L for factory made sheet metal encloser (LT panel) made out of 3.15 mm thick CRCA sheet powder coated weather proof out door type with 60cm long legs 4 Nos made out of 40 x 40 x 6 mm equal angle size of encloser not less than 120 x 75 x 45 cm depth with front and rear openable double door with locking arrangement including 4 strip aluminium bus bar of lengh 75 cm of 400 amps capacity, mounted on insulators including and connection in the new chamber with bolts and nuts, including thimbles of suitable sizes, neccessary earth work and PCC foundation for grouting of four legs complete all as specified and directed by Engr-in-charge.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 32 x 6mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common salt including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40x40x5mm frame, GI medium grade watering pipe 40 mm bore and funnel with wire mesh light grade protection pipe 20 mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by Engr-in-Charge. Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.
Taking out unsrviceable LT UG cable of any size 150 sqmm complete all as specified and directed by Engr-in-charge.
Description all as per serial item No 15.00 here-in-before but size of 120 Sqmm 3.5 Core.
Description all as per serial item No 15.00 here-in-before but size of 95 Sqmm 3.5 Core.
Description all as per serial item No 15.00 here-in-before but size of 50 Sqmm 3.5 Core.
Description all as per serial item No 15.00 here-in-before but size of 25 Sqmm 3.5 Core.
Supplying, laying, jointing and testing LT underground cable of size 150 sqmm 3.5 core, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable, laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts complete all as specified and directed by Engr-in-charge.
Description all as per serial item No 16.00 here-in-before but size of 95 Sqmm 3.5 Core.
Description all as per serial item No 16.00 here-in-before but size of 50 Sqmm 3.5 Core.
Description all as per serial item No 16.00 here-in-before but size of 25 Sqmm 3.5 Core.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes foundations of poles/stays/pipes etc .not exc 10 Sqm area on plan and getting out in soft/loose soil complete all as specified and directed by Engr-in-charge.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engr-in-charge.
Removing of excavated soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-charge.
M&L for sand cushioning to UG cable laid in trenches with clean dry river sand 8 cm below & 15 cm above the cable & punned down to 18 cm thickness complete all as specified and directed by Engr-in-Charge. Note: - For payment purpose 18 cm thickness shall measured.
M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed by Engr-in-charge.
Supply and laying GI tubing 50mm dia light grade laid in trenches/floor/fixing on pole / wall / in tarmac including necessary fittings etc complete all as specified and directed by Engr-in-charge.
S&F straight through joint kit, heat shrinkable type suitable for 25 to 35 Sqmm LT underground cable complete all as specified and directed by Engr-in-charge.
S&F straight through joint kit, heat shrinkable type suitable for 50 Sqmm LT underground cable complete all as specified and directed by Engr-in-charge.
S&F straight through joint kit, heat shrinkable type suitable for 70 Sqmm LT underground cable complete all as specified and directed by Engr-in-charge.
S&F straight through joint kit, heat shrinkable type suitable for 95 Sqmm LT underground cable complete all as specified and directed by Engr-in-charge.
S&F straight through joint kit, heat shrinkable type suitable for 120 to 150 Sqmm LT underground cable complete all as specified and directed by Engr-in-charge.
Supply,Installation,commisioning and Testing of 200 KVA capacity Transformer step down 11KV/0.433KV, copper wound,Outdoor type AC supply, 3 Phase, 4wire, 50 HZ, Oil immersed naturally cooled delta connected on Primary (HV side) and star connected as secondary (LV side) having equal tapping up to +/- 7.5% in the step of 2.5% with off load tap changer,vector group Dyn-11 and first filling of fresh Tr. oil, with standard fittings/accessories such as breather, drain valve, Conservator tank, HV Cable box, LV Cable box including inbuilt protection and first fill of transformer oil (of die electric strength not less than 50 KV) upto required level in conservator tank with cover boxes, dial type thermometer, roller, stop taps, breather with silica gel, conservator etc complete all as specified in (Level – II) IS : 1180 (Part – I) / 2014. The Transformer oil shall be confirming to IS-335.
1. The Transformer oil shall be fresh and approved certificate from manufacturer shall be obtained by contractor and furnished to GE. 2. The copper shall be 99.97% purity and approved certificate from manufacturer shall be obtained by contractor and furnished to GE. 3. Pre-commissioning, inspection of transformer shall be carried out by the rep pf Accepting Officer. T&P for the inspection shall be arranged by the contractor. The cost of the same is deemed to be included in the quoted rate.
M&L for construction of Plinth for Transformer 1.5 M height X 2.5 M width X 2.5 M length incl. Morum filling and PCC at top 10 cm thick (1:2:4) and PCC foundation with 1:4:8 (80 cm width X 2.7M length in square foundation 25 cm height) all as per drawing provide by the department including plastering to exposed walls and white wash,providing M S Channel on top of size 75X40X8 mm of 1.5 M in length for rolling to transformer,including chain link fencing of wire mesh 150X100 size made out of GI wire of height 1.5 M fixed with the help of MS strip 25X6 mm on and including MS angle iron 75X45X6mm thick 12 nos post by the means of drilling holes at the distance of 30 cm and fixed with the help of suitable nut,bolt and washer.the length of MS angle iron not less than 2.25 M, top of post bend to the shape of 60 degree including 3 nos. cuts for inserting barbed wire including 03 run of barbed wire and including provision of gate of size 1.5MX0.9M made out of MS angle iron 50X50X6mm and MS bar 12 mm dia for meshing the gate and locking arrangement including PCC foundation 1:2:4 type B-1 for posts complete all as specified and directed by Engr-in-charge.
S&F Indoor type unbalanced Servo Controlled Voltage stabilizer,copper wound, for automatic operation, three phase, oil cooled, As per BIS 9815 : Part 1 & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 1%, AC 3 Phase,50 Hz, Response time Less than 10 mili second, Breakdown strength 2500 Ac for 2 minute,Insulation Resistance (IR) More than 100 Mega ohms at 500 V DC,Ambient Temperature : 0-55ºC,Duty Cycle : Continuous,Metering: Digital Meter VA,Efficiency 98% or more,with High low voltage cutoff,Over Voltage/under voltage Protection,Over load and short circuit Protection,Phase failure,Bypass arrangement system of capacity 100 KVA with first fill of Transformer oil (IS335: 1993 reaffirmed 2005) Make: Vinitec/Sinetrack/AE/Volina/ITE Gurgaon
Suplply and laying XLPE insulated armoured cable of size 120 Sqmm 3.5 Core (heavy duty) electric cable with aluminium stranded conductor 1100 volts grade of following size incl jointing and testing complete in trenches/duct/pipe/ drawn across road/path/drain along the floor/wall etc complete all as specified and directed by Engr-in-charge including taking out old u/s cables.
Supply, installation, testing and commissioning of outdoor type,weather proof, cubicle LT Panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 bocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :-
(a) Aluminium bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 450 amps for Phases neutral - 01 set (b) Panel indicating lamp neon/LED type (Red ,Yellow & Blue) with lamp holders - 03 Nos (c) Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job Incoming :- (a) MCCB 4 pole , Ics=100%Icu- 35/36 KA, 415 Volts, 300 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 Nos. (b) On Load Change Over Switch, Front Operated, 4 pole,320 amps,440 Volts,50 Hz,-01 N0.
Outgoing :- (a) MCCB 4 pole , Ics=100%Icu- 25/26 KA, 415 Volts, 200 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 Nos. (b) MCCB 4 pole , Ics=100%Icu- 25/26 KA, 415 Volts, 100 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 No. (c) PCC 1:2:4 type B-1 for grouting 4 legs of feeder pillar box. Note: - Various feeder shall be indicated by 50 mm high letter in white synethetic enamel paint.
FANGALIA TRADERS
proach associates
PREM NATH KHAJURIA AND SONS
kailu construction co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .