| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.9 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹40.7 L+₹3.7 L (10.1%)Rejected-AOC C O AKBAR FURNITURE HOUSE MALHAR MORH GARHI UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-AOC NOT ACCEPTED | |
| 3 | L3₹40.9 L+₹3.9 L (10.6%)Rejected-AOC | L3 | Rejected-AOC NOT ACCEPTED | |
| 4 | L4₹43.5 L+₹6.5 L (17.6%)Rejected-AOC WARD NO 11 HOUSE NO 305 JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-AOC NOT ACCEPTED | |
| 5 | L5₹44.6 L+₹7.6 L (20.7%)Rejected-AOC | L5 | Rejected-AOC NOT ACCEPTED |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
23 Nov 2019, 6:00 pmClosed
GE SOUTH UDHAMPUR
GE SOUTH UDHAMPUR C/0 56 APO
PROVN OF PARKING ROOF TREATMENT AND WATER PROOFING IN CERTAIN BLDGS PVC CUPBOARD AND ALLIED WKS IN BLDG NO P 19 TO P 21, ADDN/ALTN TO BLDG NO P 70 AT OFFICERS MESS OF HQ NORTHERN COMD AND CERTAIN REVENUE AND MINOR WORK UNDER GE SOUTH UDHAMPUR
2019_MES_286839_2
GE/S(U)-41/2019-20
Open Tender
Civil Works
Item Rate
240 days
NORTHERN COMD UDHAMPUR
REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH UDHAMPUR
₹97,000
Yes
5 Mar 2020
9 Nov 2019
25 Nov 2019
9 Nov 2019
23 Nov 2019
11 Nov 2019
9 Nov 2019 - 11 Nov 2019
Amount
Demolition of cement concrete of any description and in any position not otherewise specifically provided including removal of old treatment of any description complete all as specified and directed.
Roughening surfaces of old concrete floor by picking sweeping cleaning and washing down with water to remove dust etc including removal of old treatment of any description and applying one coat of neat cement slurry @ 3.00 kg/Sqm complete all as specified and directed by Engr-in-Charge.
PCC 1:2:4 type B-1 (using 12.5 mm graded aggregate) as in level course on roof surface 25 mm thick etc complete all as specified and directed.
Rendering 10 mm thick in cement mortar 1:3 mixed with integral water proofing compound as per manufacture's instructions as in roof and chajjas, finished the surface fair and even with out using extra cement complete all as specified and directed. Note : Supply of water proofing compound will be measured and paid separately.
PCC 1:2:4 type B-1 (using 20 mm graded aggregate) as in base of water tank on roof surface complete all as specified and directed.
Applying bituminous primer on roof surfaces @ 0.40 ltr/sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 kg/sqm and provide modified polymeric five layered APP (Atactic Polypropylene) Modified Polymeric Membrane with 100 micron high molecular high density polythylene film. Minimum weight of memebrane will be 3.5 kg/sqm and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) and over APP applying one coat of hot blown bitumen 85/25 @ 1.2 kg/sqm blinded with fine sand in dry condition @ 0.5 kg/sqm including two coats of bituminious alluminium paint complete all as specified and directed by Engr-in-Charge.
Supply only integral water proofing compound complete all as specified and directed.
Cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate ) in cills, seismic and other similar bands, plinth courses, copings, bed plates, bond stones, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete.
Taking down cement plaster and raking out joints, hacking for key, scrubbing down with water built in cement mortar any description complete all as specified and directed.
Rendering 15 mm thick on fair faces of brick work in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed.
Rendering 5 mm thick in cement mortar 1:3 on ceiling, chajja, roof projection etc finished fair and even without using extra cement complete all as specified and directed.
Preparation of new plastered or un-plastered surfaces and walls including cornices, pilasters etc and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
Preparation of new plastered or un- plastered surfaces and applying three coats of white wash on ceiling complete all as specified and directed.
Preparation of new plastered or un- plastered surfaces and applying three coats of white wash on walls complete all as specified and directed.
Disconnecting existing tanks of exceeding 250 but not exceeding 500 ltr capacity setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position with cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc. complete all as specified and directed.
Disconnecting existing tanks of exceeding 500 but not exceeding 1000 ltr capacity setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position with cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc. complete all as specified and directed.
Rotational moulded polyethylene water storage tanks 500 ltrs (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR part I inclding dismantaling of existing damaged water tanks complete all as specified and directed.
Rotational moulded polyethylene water storage tanks 1000 ltrs (cylindlerical verrtical with closed top) hoisted and fixed in position complete all as specified and directed in SSR part-I including dismantaling of existing damaged water tanks.
PTMT ball valves 20 mm dia high pressure with epoxy coated aluminium rod and high denscity plastic ball screwed for iron pipes and fixed to iron pipes complete all as specified and directed.
Gun metal globe or gate valves high pressure with polythene float and fly nut complete screwed for iron pipe or for unions of 20 mm bore and complete all as specified and directed.
Steel tubing galvanized, medium grade with all fittings, laid in floors or fixed to walls with all necessary GI fitting, 15 mm bore including taking down old pipe complete all as specified and directed.
Steel tubing galvanized, medium grade with all fittings, laid in floors or fixed to walls, 20 mm bore with all necessary GI fitting including taking down old pipe complete all as specified and directed.
Refixing old 15 mm steel tubing and connection in new or old position with all necessary GI fitting (wall, ceiling, floors etc) including taking down old pipe complete all as specified and directed.
Refixing old 20 mm dia and above steel tubing and connection in new or old position with all necessary GI fitting (wall, ceiling, floors etc) including taking down old pipe complete all as specified and directed.
Demolition and beaking up drain AC pipes/PVC pipe set in cement mortar 100 mm and below complete all as specified and directed.
110 mm PVC (SWR) pipes single socket in any length with rubber ring joints fixed to wall complete all as specified and directed.
110 mm PVC (SWR) bends any redius with access door complete all as specified and directed.
110 mm PVC (SWR) couplers for PVC pipe and similar work complete all as specified and directed.
75 mm PVC (SWR) pipes single socket in any length with rubber ring joints fixed to wall complete all as specified and directed.
75 mm PVC (SWR) bends any redius with access door complete all as specified and directed.
Cabinet/cupboard in required size at site made out 18 mm thick one side decorative lamination and other side balancing lamination sheet consisting of carcass 18 mm thick PVC sheet and provision of shutters made out of 18 mm thick one side decoartive laminated PVC sheet all required brackets 5.5 screws etc. The panels shall be fabricated using adhesive and screws where ever required. All the edbes shall be covered with 2 mm thick edge bonding tape or 90 degree edge bent finish as per make and specification directed by Engr-in-Charge or Colour as approved by GE.
PVC steel catcher of superior quality complete all as specified and directed by Engr-in-Charge.
100 mm long stainless steel alloy handles, decorative type approved and complete all as specified and directed by Engr-in-Charge.
Butt hinges, 75 mm size medium weight, cold rolled mild steel all as approved and complete all as specified and directed by Engr-in-Charge.
Rolled Mild steel sections as in frame work for framed work, hold fast, fixing of cupboard and similar work, main and cross beams hip and jack rafters, purlines fixed independently and similar work including welding and demolition of wall for fixing of hold fast as per requirement complete all as specified and directed by Engr-in-Charge.
PCC 1:2:4 type B-1 (using 20 mm graded aggregate) as in PCC filling in hold fast and similar work complete all as specified and directed.
Complete removal of existing treatment and applying two coats of oil bound distemper over a coat primers with two coat of wall care putty complete all as specified and directed by Engr-in-Charge.
Preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
20 mm dia mild steel powder coated tubular curtain rail with brackets and end bulb as per requriment complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete in ground floor and paving not exceeding 15 cm thickness below and above ground level complete all as specified and directed.
25 mm thick PCC 1:2:4 type B-1 (using 20 mm graded aggregate) as in level course on floor etc complete all as specified and directed.
15 mm thick screed bed in cement mortar 1:6 for laying floor finishes under floor complete all as specified and directed.
Vitrified ceramic tiles (Double charge), polished, area of each tile exceeding 0.42 sqm but not exceeding 1.00 sqm, 10 mm thick (square or rectangular) of superior quality as in floor surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match the dark shade/any shed of tiles complete all as specified and directed.
All as per ser item No 43 above but in vertical surfaces such as skirting/dado etc complete all as specified and directed.
Non skid coloured tiles 7 to 8 mm thick area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding but not backing complete all as specified and directed.
Rendering 10 mm thick on fair faces of brick work or concrete surface in cement mortar 1:4 on vertical surfaces/backing coat complete all as specified and directed.
Glazed ceramic coloured tiles of size 300 x 600 x 7 mm wall tiles set and jointed in neat cement and in white/coloured cement to match with the colour of tile etc complete all as specified and directed.
Providing and injecting Along the external wall below concrete or masonry apron using Antitermite Treatment chemical emulsion @ 2.25 litres per running metre including drilling and plugging holes etc. in apron complete all as specified and directed by Engr-in-Charge. Note : The treatment work shall be carried through authorised agency only, and certificate for the same for waranty shall have to be furnished before submitting payment.
Providing and injecting Antitermite Treatment of soil under existing floors using emulsion @ 1 litre per hole, 300 mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand to match the existing floors complete all as specified and directed by Engr-in-Charge. Note : The treatment work shall be carried through authorised agency only, and certificate for the same for waranty shall have to be furnished before submitting payment.
Providing and injecting Antitermite Treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6 mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing the same complete all as specified and directed by Engr-in-Charge. Note : The treatment work shall be carried through authorised agency only, and certificate for the same for warranty shall have to be furnished before submitting payment.
Rendering 10 mm thick in cement mortar 1:6 on fair faces of brick/concrete finished even and smooth without using extra cement complete all as specified and directed.
Preparation of new plaster surface of walls and applying two coat of oil bound distempers over one coat of primer and two coat of wall care putty complete all as specified and directed by Engr-in-Charge.
12 mm thick toughened glass partition and similar work with fixing of stain less steel clit/stain less steel clamp to wall and floor complete all as specified and directed by Engr-in-Charge.
Sand blasting to glass of approved design and pattern complete all as specified and directed by Engr-in-Charge. Note : Glass has to be paid and measured for seperately.
Surface excavation not exceeding 30 cm deep and ageraging 25 cm deep and getting out in hard and dense soil complete all as specified and directed.
Removing excavated soil form site to a distance exceeding 50 m and not exceeding 1.50 km out side defence land complete all as specified and directed.
100 mm thick PCC 1:4:8 type D-2 (using 40 mm graded aggregate) as in sub base of floor etc complete all as specified and directed.
Sand cushion 20 to 30 mm thick for laying and fixing interlocking tiles complete all as specified and directed.
Machine pressed precast concrete interlocking paver block (glossy finish)of approved shape and size confirming to IS 15658-2006 of 80 mm thickness with grey cement and pigment, M-40 Grade of approved colour and design complete all as specified and directed by Engr-in-Charge.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation etc or for shafts, wells, cesspits, manholes, pier holes and similar work and getting out in any type of soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and directed.
Cement concrete type D-2 1:4:8 (40 mm graded aggregate) in foundation filling and mass concrete complete all as specified and directed.
Brick work with sub class 'B' bricks straight or curved on plan exceeding 6 mtr mean radius built in cement mortar (1:4) as in drain, walls and similar work etc complete all as specified and directed.
Roof trusses (framed) trussed, purlins, crane gantries rails and fastenings and heavy brackets, post, framed for eves board and similar work framing (beam, tee, channel or flat sections) including distance pieces cleats including welding reavrign etc. complete all as spcified and directed.
Pre-painted galvatume aluminum zinc coating GI vased corrugated steel sheet 0.60 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws complete all as spcified and directed.
Pre-painted galvatume aluminum zinc coating GI vased Plain steel sheet 0.60 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws complete all as spcified and directed.
15 mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6 and finishing the surfaces even and smooth without using extra cement complete all as spcified and directed.
75 mm thick PCC 1:4:8, type D-2 (by using 40 mm graded stone aggregate) as in sub base floor complete all as spcified and directed.
Vitrified ceramic tiles, area of each tile not exceeding 0.36 sqm, 10 mm thick (square or rectangular) of superior quality as in floor surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed.
Demolition of Bricks or stone masonry built in cement mortar complete all as specified and directed.
Brick work with sub class 'B' brick, straight or curved on plan exceeding 6 m mean radius built in type cement mortar 1:6 complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Hand rails, half rounded or other steel section, posts and struts in fencing including cutting tops to shape as directed, water tank staging with guard cover, angle iron for purline and rafter work, including drilling holes, notching for wire including all necessary drilling, bolting or riveting etc and similar work complete all as specified and directed.
Preparation of new steel surfaces of any descripton not otherwise described over 10 cm width or girth and applying two coats of synthetic enamal paint over a coat of red oxide on steel surfaces complete all as specified and directed.
Dismantling of AC sheets (corrugated and semi corrugated etc) in roofing including ridge tiles complete all as specified and directed.
Pre-painted galvatume aluminum zinc coating GI vased corrugated steel sheet 0.60 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws complete all as specified and directed.
Precast cement concrete louvres and jallies 50 mm thick set in cement mortar 1:6 type B-0 1:2:4 (using 12.5 mm graded aggregate) etc sample as approved by GE including taking out old precast Jalli complete all as specified and directed by Engr-in-Charge.
Taking down carefully, copper/aluminum point wiring (light, fan, socket or power) complete fitting such as switch, sockets, ceiling rose, pendants socket any type, rectangular board terminal boxes etc and making good disturbed surfaces of walls floors and ceiling complete all as specified and directed.
Point wiring for one light/fan point controlled by one switch using 1.5 Sq mm FRLS copper conductor cables (multistanded) PVC insulated and unseathed in and including PVC concealed conduit (thickness not less than 1.5 mm and 20 mm dia), medium grade with Modular metal sunken boxes and PVC back plate for mounting modular type in adequate module of switches, sockets and regulators etc with front plate modular type including supplying and laying PVC insulated unsheathed 1100 volts coppper conductor cable 1.5 Sq mm as earth wire stranded and conected to earth dolly complete all as specified and directed.
All as per ser item No 80 but for two way switch one light point controlled by two way switches, with cables 1.5 sq. mm size earth wire complete all as specified and directed.
All as per ser item No 80 but for 3 pin 5 Amps socket outlet independent including copper PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly complete all as specified and directed.
All as per ser item No 80 but for 3 pin 5 Amps socket outlet on the same board including copper PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly complete all as specified and directed.
All as per ser item No 80 but for 3 Pin 15 Amps socket outlet independent with cable 4 Sq mm including copper PVC insulated PVC unsheathed 2.5 sq mm earth wire standard and connected to earth dolly complete all as specified and directed.
Module switch 6 Amps single pole one way (Modular Type) with outer strip complete all as specified and directed.
Module switch 16 Amps single pole one way (Modular Type) with outer strip complete all as specified and directed.
Socket 3 Pin 6 Amps flush type (Modular Type) with outer strip complete all as specified and directed.
Socket combined 2-in-1, 6 Pin 6 and 16 Amps flush type (Modular Type) with outer strip complete all as specified and directed.
Ceiling rose, surface bakelite 65 x 50 mm three terminals fixed on PVC Round Block complete all as specified and directed.
Electronic stwp type fan regulator 120 watt 230 volts 50 C/S deluxe type complete all as specified and directed.
Bell Push, 6 amp, 230 Volts, 1 Modular type complete all as specified and directed.
Call bell ding-dong 230 volts including taking down old one complete all as specified and directed.
Earthing complete with galvanised steel earth plate electode 600 mm x 600 mm x 6.00 mm thick burried directly in ground (earth pit not less than 2.25 meter deep below normal ground level connected to and including galvanised steel earth lead wire 4 mm dia by means of bolts, nuts, chock, nuts and washers of galvanised iron or steel including PCC Pit in 1:2:4 type B-I angle iron frame with RCC cover and handle, excavation and earth work in any type of soil medium grade GI watering pipe 20 mm bore with funnel and wire mash and light grade GI protection pipe 15mm bore upto main board complete all as shown in electrical plate No 3 of MES Sch 2009 (Part I) connected to main control board complete all as specified and directed and testing completion.
New E-Lite LED Curve, high lumen batten with efficacy of 100 lumens in 20 W complete all as specified and directed by Engineer-in-Charge. Make- Havells Cat Part No LHEXBXPNIN1W020 or equivalent to Polycab/HPL/Bajaj
Replacement New E-Lite LED Curve, high lumen batten with efficacy of 100 lumens in 5 W complete all as specified and directed. Make - Havells, Cat Part No LHEXBYPNIN1W005 or equivalent make in Syska/C&S
Taking down ceiling/Exhaust fan including disconnection of existing connection, dismanting of blades and Painting of fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. and rehanging the fan complete all as specified and directed.
Garnet Slim 40 Watt 2 x 2 LED Flat Panel light with diffused optics (590 x 590 mm) complete making all connection with suitable size flexible cable from ceiling rose to fitting including taking down old one fixed in repair complete all as specified and directions of Engr-in-Charge. Make - WIPRO Cat Part No D414065 or equivalent make in Syska/C&S
1 x 12 W LED Bulb wall light fixture made up of polycarbonate, suitable for 12 W LED bulb fixed in repair complete all as specified and directions of Engr-in-Charge. Make - Havells, Cat Part No LHFOFVE1TZ1W012 or equivalent make in Syska/C&S
Sheet metal enclosure single pole and neutral with a two pin earth plug and socket with one single pole MCB 20 AMP complete all as specified and directed.
Bed Side Lamp 10 W fixed in repair complete all as specified and directions of Engr-in- Charge. Make - Havells/Bajaj/ HPL/Philips
Point wiring for one light point/fan point controlled by one switch with 1.5 sqmm PVC insulated FRLS unsheathed copper conductor single core multi stranded flexible copper cable in and including not less than 2.00 mm thick 20 mm dia and over Non metallic Rigid PVC surface/ Concealed Conduit (ISI marked) with and all accessories 1.5 mm thick mild steel terminal boxes concealed on walls, painting the same inside and out side with one coat of black bitumen paint with 3mm thick hylam brand bakelite sheet cover for fixing of piano switches/sockets/regulator etc along with PVC insulated and unsheathed FRLS 1.00 sq mm multi stranded copper conductor cable (green color) as earth lead and connected to common earth and earthdolly, making good the disturbed surface to match with the existing specification complete all as specified and directed by Engr-in- Charge. Make - KEI or equivalent make in polycab/finolex
Switch piano flush button single pole one way 5 amps 240 volt complete all as specified and directed.
Ceiling rose surface bakelite 3 terminals complete all as specified and directed. Make in Havells/Anchor/Kolors.
Sheet metal enclosure MCB distribution board single pole and neutral 240 volts 4 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. Note - MCBs will be measured separately.
Replacement MCB Single Pole, 230 Volt, Raiting 6 to 32 Amps complete all as specified and directed. Make : Indoasian Cat Part No : 811015 or equivalent Havells/Legrand.
Replacement MCB Single Pole and Neutral, 230 Volt, Raiting 35 to 63 Amps complete all as specified and directed. Make : Indoasian Cat No : 811037 or equivalent Havells/Legrand.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 4 Sqmm in PVC concealed conduit 25 mm dia including PVC insulated copper conductor cable 2.5 Sq mm as earth lead complete all as specified and directed. Including taking down old sub main wire.
Modular switch 2 way 6A, 1 module with outer strip complete all as specified and directed.
M/S ASHOK KUMAR PACHIALA
khajuria builders
PARDEEP SHARMA
verinder kumar gupta
s l sharma and sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .